Search NASA⌕ Search

SEARCH · Search NASA

Results for “focal plane array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Carrier Plus: A sensor payload for Living With a Star Space Environment Testbed (LWS/SET)

The Defense Threat Reduction Agency (DTR4) and National Aeronautics and Space Administration (NASA) Goddard Space Flight Center are collaborating to develop the Carrier Plus sensor experiment platform as a capability of the Space Environments Testbed (SET). The Space Environment Testbed (SET) provides flight opportunities for technology experiments as part of NASA's Living With a Star (LWS) program. The Carrier Plus will provide new capability to characterize sensor technologies such as state-of-the-art visible focal plane arrays (FPAs) in a natural space radiation environment. The technical objectives include on-orbit validation of recently developed FPA technologies and performance prediction methodologies, as well as characterization of the FPA radiation response to total ionizing dose damage, displacement damage and transients. It is expected that the sensor experiment will carry 4-6 FPAs and associated radiation correlative environment monitors (CEMs) for a 2006-2007 launch. Sensor technology candidates may include n- and p-charge coupled devices (CCDs), active pixel sensors (APS), and hybrid CMOS arrays. The presentation will describe the Carrier Plus goals and objectives, as well as provide details about the architecture and design. More information on the LWS program can be found at http://lws.gsfc.nasa.gov/. Business announcements for LWS/SET and program briefings are posted at http://lws-set.gsfc.nasa.gov

Marshall, Cheryl J.↗

Chemical and physical gradients along the OMC-1 ridge

We present a survey of the distribution of 20 chemical and isotopic molecular species along the central ridge of the Orion molecular cloud from 6' north to 6' south of BN-KL observed with the QUARRY focal plane array on the FCRAO 14 m telescope, which provides an angular resolution of approximately 50" in the 3 mm wavelength region. We use standard tools of multivariate analysis for a systematic investigation of the similarities and differences among the maps of integrated intensities of the 32 lines observed. The maps fall in three broad classes: first, those strongly peaked toward BN-KL; second, those having rather flat distributions along the ridge; and third, those with a clear north-south gradient or contrast. We identify six positions or regions where we calculate relative abundances. Line velocities and line widths indicate that the optically thin lines generally trace the same volume of dense gas, except in the molecular bar, where C18O, C34S, H13CO+, CN, C2H, SO, and C3H2 have velocities characteristic of the bar itself, whereas the emission from other detected species is dominated by the background cloud. The strongest abundance variations in our data are the well-known enhancements seen in HCN, CH3OH, HC3N, and SO toward BN-KL and, less strongly, toward the Orion-South outflow 1'.3S. The principal result of this study is that along the extended quiescent ridge the chemical abundances, within factors of 3-4, exhibit an impressive degree of uniformity. The northern part of the ridge has a chemistry closest to that found in quiescent dense clouds. While temperature and density are similar around the northern radical-ion peak near 3'.5N and in the southern core near 4'.2S, some abundances, in particular, those of the ions HCO+ and N2H+, are significantly lower toward 4'.2S. The areas near 4.'2S and the molecular bar itself around (1'.7E, 2'.4S) stand out with peculiar and similar properties probably caused by stronger UV fields penetrating deeper into the clumpy molecular gas. This leads to higher electron abundances and thereby reduced abundances of the ions, as well as a lack of complex molecules.

NASA Discipline Exobiology↗

X-Ray Fluorescence Solvent Detection at the Substrate-Adhesive Interface

With environmental regulations limiting the use of volatile organic compounds, low-vapor pressure solvents have replaced traditional degreasing solvents for bond substrate preparation. When used to clean and prepare porous bond substrates such as phenolic composites, low vapor pressure solvents can penetrate deep into substrate pore networks and remain there for extended periods. Trapped solvents can interact with applied adhesives either prior to or during cure, potentially compromising bond properties. Currently, methods for characterizing solvent time-depth profiles in bond substrates are limited to bulk gravimetric or sectioning techniques. While sectioning techniques such as microtome allow construction of solvent depth profiles, their depth resolution and reliability are limited by substrate type. Sectioning techniques are particularly limited near the adhesive-substrate interface where depth resolution is further limited by adhesive-substrate hardness and, in the case of a partially cured adhesive, mechanical properties differences. Additionally, sectioning techniques cannot provide information about lateral solvent diffusion. Cross-section component mapping is an alternative method for measuring solvent migration in porous substrates that eliminates the issues associated with sectioning techniques. With cross-section mapping, the solvent-wiped substrate is sectioned perpendicular rather than parallel to the wiped surface, and the sectioned surface is analyzed for the solvent or solvent components of interest using a two-dimensional mapping or imaging technique. Solvent mapping can be performed using either direct or indirect methods. With a direct method, one or more solvent components are mapped using red or Raman spectroscopy together with a moveable sample stage and/or focal plane array detector. With an indirect method, an elemental "tag" not present in the substrate is added to the solvent before the substrate is wiped. Following cross sectioning, the tag element can then be mapped by its characteristic x-ray emission using either x-ray fluorescence, or electron-beam energy-and wavelength-dispersive x-ray spectrometry. The direct mapping techniques avoid issues of different diffusion or migration rates of solvents and elemental tags, while the indirect techniques avoid spectral resolution issues in cases where solvents and substrates have adjacent or overlapping peaks. In this study, cross-section component indirect mapping is being evaluated as a method for measuring migration of d-limonene based solvents in glass-cloth phenolic composite (GCP) prior to and during subsequent bonding and epoxy adhesive cure.

Wurth, Laura↗

Temperature-dependent optical properties of Cd(1-x),Zn(x),Te substitute material

In this study, we report cryogenic optical properties of Cd(l-x), Zn(x), Te wafers that are used as substrate seed layers in the manufacturing of HgCdTe focal-plane array detectors. These studies are motivated by the fact that the substrate optical properties influence the overall detector performance. The studies consist of measuring the substrate frequency dependent transmittance T(W) and reflectance R(W) above and below the optical band-gap in the UV/Visible and infrared frequency ranges, and with temperature variation of the sample from 5 to 300 K. Determination of the optical absorption from these measurements show that the optical absorption energy gap near 1.6 eV shows a substantial increase as the temperature is reduced from 300 to 5 K. Furthermore, we observe the presence of infrared-active optical phonons whose peak frequency shifts as the temperature of the sample is varied over the measured temperature range. The theoretical frequency dependent optical conductivity, with allowance for redistribution of spectral weight among the interband transition charge carriers, will be discussed.

Quijada, Manuel A.↗

Delta-doped imagers for UV and EUV applications

In this paper we will discuss performance of delta-doped CCDs in UV and EUV, our in-house thinning capability, bonding approaches for producing flat focal plane arrays, and in-house capabilities of directly applied antireflection coatings.

UV EUV delta-doped imagers↗

(abstract) Applications of Long-wavelength 256x256 GaAs/Al&subx;Ga&sub1-x;As Quantum Well Infrared Photodetector Hand-held Camera

A 9 (micro)m 256x256 hand-held quantum well infrared photodetector (QWIP) camera has been demonstrated. Excellent imagery, with a noise equivalent differential temperature (NE(gamma)) of 26 mK has been achieved. In this presentation, we discuss the development of this very sensitive long wavelength infrared (LWIR) camera based on a GaAs/AlGaAs QWIP focal plane array, its performance in quantum efficience, NA(gamma), minimum resolvable temperature (MRTD), uniformity, operability, and its applications.

GaAs infrared photodetector quantum well QUIP nois↗

15 cut-off 128x128 Quantum Well Infrared Photodetectors (QWIPS) Camera

We discuss the development and the performance of a very long wavelength (13.5 - 15 128x128 AlGaAs/GaAs multiquantum well infrared imaging system. Highly uniform, high-yield QWIP focal plane array was hybridized to a CMOS multiplexer operating in a direct injection mode. For efficient light coupling an integral random scattering reflector (Random Grating) was incorporated. Due to the high uniformity, excellent imagery, low noise as well as a noise equivalent temperature difference (NE T) of less than 30 mK were obtained when operating around 45 K. Therefore, high image contrast signal to noise ratio has been achieved.

128x128 Photodetectors↗

A Combined Laser-Communication and Imager for Microspacecraft (ACLAIM)

ACLAIM is a multi-function instrument consisting of a laser communication terminal and an imaging camera that share a common telescope. A single APS- (Active Pixel Sensor) based focal-plane-array is used to perform both the acquisition and tracking (for laser communication) and science imaging functions.

Laser Communication Optical Communication Science ↗

Recent Improvements to the Airborne Visible/Infrared Imaging Spectrometer (AVRIS)

Several improvements have been made to the Airborne Visible/Infrared Imaging Spectrometer (AVRIS) since 1994--new focal plane arrays, a new analog and digital chain and an onboard calibration lamp controlled by radiance feedback. These changes increased the signal-to- noise ratio by 2 to 3 times, eliminated noise spikes and the need for spectral sampling, and greatly reduced dark-current noise.

AVRIS improvements spectrometer↗

Distributed Antenna-Coupled Transition Edge Sensors

We describe progress toward realizing a new architecture for focal plane arrays for the Submillimeter and Far- Infrared (FIR) bands. This architecture is based on a detector design utilizing distributed hot{electron transition edge sensors (TES) coupled to slot antenna elements. Arrays utilizing this type of detector can be considerably easier to manufacture than membrane-isolated TES arrays, because the need for micro-machining is eliminated. We present background and rationale for this new array architecture and details of a new antenna design for an imaging polarimeter, which yields greater bandwidth than past designs. In addition, we describe a cryogenic facility for testing these arrays.

bolometer↗

GIFTS SM EDU Data Processing and Algorithms

The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiances using a Fourier transform spectrometer (FTS). The GIFTS instrument employs three Focal Plane Arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the processing algorithms involved in the calibration stage. The calibration procedures can be subdivided into three stages. In the pre-calibration stage, a phase correction algorithm is applied to the decimated and filtered complex interferogram. The resulting imaginary part of the spectrum contains only the noise component of the uncorrected spectrum. Additional random noise reduction can be accomplished by applying a spectral smoothing routine to the phase-corrected blackbody reference spectra. In the radiometric calibration stage, we first compute the spectral responsivity based on the previous results, from which, the calibrated ambient blackbody (ABB), hot blackbody (HBB), and scene spectra can be obtained. During the post-processing stage, we estimate the noise equivalent spectral radiance (NESR) from the calibrated ABB and HBB spectra. We then implement a correction scheme that compensates for the effect of fore-optics offsets. Finally, for off-axis pixels, the FPA off-axis effects correction is performed. To estimate the performance of the entire FPA, we developed an efficient method of generating pixel performance assessments. In addition, a random pixel selection scheme is designed based on the pixel performance evaluation.

Tian, Jialin↗

Temperature Evolution in Excitonic Absorptions of Cd(0.96)Zn(0.04) Materials

We report cryogenic optical properties of Cd(0.96)Zn(0.04)Te wafers that are used as substrate seed layers in HgCdTe focal-plane array detectors. These studies are motivated by the fact that the substrate optical properties influence the overall detector performance. The studies consist of measuring the sample frequency dependent transmittance (T) and reflectance (R) above and below the optical band-gap in the UV/Visible and infrared frequency ranges, and with temperature variation of the sample from 5 to 300 K. These measurements show that the optical gap near 1.49 eV at 300 K increases to 1.62 eV at 5 K. Finally, we observe sharp absorption peaks near this gap energy at low temperatures. The close proximity of these peaks to the optical transition threshold suggests that they originate from the creation of bound electron-hole pairs or excitons. The decay of these excitonic absorptions may contribute to a photoluminescence and transient background response of these back-illuminated HgCdTe CCD detectors.

Quijada, Manuel A.↗

GIFTS SM EDU Level 1B Algorithms

The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) SensorModule (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiances using a Fourier transform spectrometer (FTS). The GIFTS instrument employs three focal plane arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the GIFTS SM EDU Level 1B algorithms involved in the calibration. The GIFTS Level 1B calibration procedures can be subdivided into four blocks. In the first block, the measured raw interferograms are first corrected for the detector nonlinearity distortion, followed by the complex filtering and decimation procedure. In the second block, a phase correction algorithm is applied to the filtered and decimated complex interferograms. The resulting imaginary part of the spectrum contains only the noise component of the uncorrected spectrum. Additional random noise reduction can be accomplished by applying a spectral smoothing routine to the phase-corrected spectrum. The phase correction and spectral smoothing operations are performed on a set of interferogram scans for both ambient and hot blackbody references. To continue with the calibration, we compute the spectral responsivity based on the previous results, from which, the calibrated ambient blackbody (ABB), hot blackbody (HBB), and scene spectra can be obtained. We now can estimate the noise equivalent spectral radiance (NESR) from the calibrated ABB and HBB spectra. The correction schemes that compensate for the fore-optics offsets and off-axis effects are also implemented. In the third block, we developed an efficient method of generating pixel performance assessments. In addition, a random pixel selection scheme is designed based on the pixel performance evaluation. Finally, in the fourth block, the single pixel algorithms are applied to the entire FPA.

Tian, Jialin↗

Digital Signal Processing Techniques for the GIFTS SM EDU

The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiance using a Fourier transform spectrometer (FTS). The GIFTS instrument employs three Focal Plane Arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes several digital signal processing (DSP) techniques involved in the development of the calibration model. In the first stage, the measured raw interferograms must undergo a series of processing steps that include filtering, decimation, and detector nonlinearity correction. The digital filtering is achieved by employing a linear-phase even-length FIR complex filter that is designed based on the optimum equiripple criteria. Next, the detector nonlinearity effect is compensated for using a set of pre-determined detector response characteristics. In the next stage, a phase correction algorithm is applied to the decimated interferograms. This is accomplished by first estimating the phase function from the spectral phase response of the windowed interferogram, and then correcting the entire interferogram based on the estimated phase function. In the calibration stage, we first compute the spectral responsivity based on the previous results and the ideal Planck blackbody spectra at the given temperatures, from which, the calibrated ambient blackbody (ABB), hot blackbody (HBB), and scene spectra can be obtained. In the post-calibration stage, we estimate the Noise Equivalent Spectral Radiance (NESR) from the calibrated ABB and HBB spectra. The NESR is generally considered as a measure of the instrument noise performance, and can be estimated as the standard deviation of calibrated radiance spectra from multiple scans. To obtain an estimate of the FPA performance, we developed an efficient method of generating pixel performance assessments. In addition, a random pixel selection scheme is developed based on the pixel performance evaluation. This would allow us to perform the calibration procedures on a random pixel population that is a good statistical representation of the entire FPA. The design and implementation of each individual component will be discussed in details.

Tian, Jialin↗

Radiation Test Results for a MEMS Microshutter Operating at 60 K

The James Webb Space Telescope (JWST), the successor to the Hubble Space Telescope, is due to be launched in 2013 with the goal of searching the very distant Universe for stars that formed shortly after the Big Bang. Because this occurred so far back in time, the available light is strongly red-shifted, requiring the use of detectors sensitive to the infrared portion of the electromagnetic spectrum. HgCdTe infrared focal plane arrays, cooled to below 30 K to minimize noise, will be used to detect the faint signals. One of the instruments on JWST is the Near Infrared Spectrometer (NIRSPEC) designed to measure the infrared spectra of up to 100 separate galaxies simultaneously. A key component in NIRSPEC is a Micro-Electromechanical System (MEMS), a two-dimensional micro-shutter array (MSA) developed by NASA/GSFC. The MSA is inserted in front of the detector to allow only the light from the galaxies of interest to reach the detector and to block the light from all other sources. The MSA will have to operate at 30 K to minimize the amount of thermal radiation emitted by the optical components from reaching the detector array. It will also have to operate in the space radiation environment that is dominated by the MSA will be exposed to a large total ionizing dose of approximately 200 krad(Si). Following exposure to ionizing radiation, a variety of MEMS have exhibited performance degradation. MEMS contain moving parts that are either controlled or sensed by changes in electric fields. Radiation degradation can be expected for those devices where there is an electric field applied across an insulating layer that is part of the sensing or controlling structure. Ionizing radiation will liberate charge (electrons and holes) in the insulating layers, some of which may be trapped within the insulating layer. Trapped charge will partially cancel the externally applied electric field and lead to changes in the operation of the MEMS. This appears to be a general principle for MEMS. Knowledge of the above principle has raised the concern at NASA that the MSA might also exhibit degraded performance because, i) each shutter flap is a multilayer structure consisting of metallic and insulating layers and ii) the movement of the shutter flaps is partially controlled by the application of an electric field between the shutter flap and the substrate (vertical support grid). The whole mission would be compromised if radiation exposure were to prevent the shutters from opening and closing properly. energetic ionizing particles. Because it is located A unique feature of the MSA is that, as outside the spacecraft and has very little shielding, previously mentioned, it will have to operate at temperatures near 30 K. To date, there are no published reports on how very low temperatures (- 30K) affect the response of MEMS devices to total ionizing dose. Experiments on SiO2 structures at low temperatures (80 K) indicate that the electrons generated by the ionizing radiation are mobile and will move rapidly under the application of an external electric field. Holes, on the other hand, that would normally move in the opposite direction through the SiO2 via a "thermal hopping" process, are effectively immobile at low electric fields as they are trapped close to their generation sites. However, for sufficiently large electric fields (greater than 3 MV/cm) holes are able to move through the SiO2. The larger the field, the more rapidly the holes move. The separation of the electrons and holes leads to a reduced electric field within the insulating layer. To overcome this reduction in electric field, a greater external voltage will have to be applied that alters the normal operation of the device. This report presents the results of radiation testing of the MSA at 60 K. The temperature was higher than the targeted temperature because of a faulty electrical interconnect on the test board. Specifically, our goal was to determine whether the MSA would function propey after a TID of 200 krad(Si).

Rapchun, David A.↗

Active pixel sensor having intra-pixel charge transfer with analog-to-digital converter

An imaging device formed as a monolithic complementary metal oxide semiconductor Integrated circuit in an industry standard complementary metal oxide semiconductor process, the integrated circuit including a focal plane array of pixel cells, each one of the cells including a photogate overlying the substrate for accumulating photo-generated charge in an underlying portion of the substrate, a readout circuit including at least an output field effect transistor formed in the substrate, and a charge coupled device section formed on the substrate adjacent the photogate having a sensing node connected to the output transistor and at least one charge coupled device stage for transferring charge from the underlying portion of the substrate to the sensing node and an analog-to-digital converter formed in the substrate connected to the output of the readout circuit.

Fossum, Eric R.↗