Durability of Membrane Electrode Assemblies (MEAs) in PEM Fuel Cells Operated on Pure Hydrogen and Oxygen

Proton exchange membrane (PEM) fuel cells are energy sources that have the potential to replace alkaline fuel cells for space programs. Broad power ranges, high peak-to-nominal power capabilities, low maintenance costs, and the promise of increased life are the major advantages of PEM technology in comparison to alkaline technology. The probability of PEM fuel cells replacing alkaline fuel cells for space applications will increase if the promise of increased life is verified by achieving a minimum of 10,000 hours of operating life. Durability plays an important role in the process of evaluation and selection of MEAs for Teledyne s Phase I contract with the NASA Glenn Research Center entitled Proton Exchange Membrane Fuel cell (PEMFC) Power Plant Technology Development for 2nd Generation Reusable Launch Vehicles (RLVs). For this contract, MEAs that are typically used for H2/air operation were selected as potential candidates for H2/O2 PEM fuel cells because their catalysts have properties suitable for O2 operation. They were purchased from several well-established MEA manufacturers who are world leaders in the manufacturing of diverse products and have committed extensive resources in an attempt to develop and fully commercialize MEA technology. A total of twelve MEAs used in H2/air operation were initially identified from these manufacturers. Based on the manufacturers specifications, nine of these were selected for evaluation. Since 10,000 hours is almost equivalent to 14 months, it was not possible to perform continuous testing with each MEA selected during Phase I of the contract. Because of the lack of time, a screening test on each MEA was performed for 400 hours under accelerated test conditions. The major criterion for an MEA pass or fail of the screening test was the gas crossover rate. If the gas crossover rate was higher than the membrane intrinsic permeability after 400 hours of testing, it was considered that the MEA had failed the test. Three types of MEAs out of the nine total membranes failed the test. The evaluation results showed that fuel cell operating conditions (current, pressure, stoichiometric flow rates) were the parameters that influenced the durability of MEAs. In addition, the durability test results indicated that the type of membrane was also an important parameter for MEA durability. At accelerated test conditions, the MEAs with casted membranes failed during the 400 hour test. However, the MEAs prepared from the casted membrane with support as well as extruded membranes, both passed the 400h durability test at accelerated operating test conditions. As a result of the MEA accelerated durability tests, four MEAs were selected for further endurance testing. These tests are being carried out with four-cell stacks under nominal fuel cell operating conditions.

Stanic, Vesna↗

Apparatus and method associated with reformer-less fuel cell

An electrolyte membrane for a reformer-less fuel cell is provided. The electrolyte membrane is assembled with fuel and air manifolds to form the fuel cell. The fuel manifold receives an oxidizable fuel from a fuel supply in a gaseous, liquid, or slurry form. The air manifold receives air from an air supply. The electrolyte membrane conducts oxygen in an ionic superoxide form when the fuel cell is exposed to operating temperatures above the boiling point of water to electrochemically combine the oxygen with the fuel to produce electricity. The electrolyte membrane includes a porous electrically non-conductive substrate, an anode catalyst layer deposited along a fuel manifold side of the substrate, a cathode catalyst layer deposited along an air manifold side of the substrate, and an ionic liquid filling the substrate between the anode and cathode catalyst layers. Methods for manufacturing and operating the electrolyte membrane are also provided.

Sahu, Saroj Kumar↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ground Motion Inputs for the Seismic Shake Table Test

Currently, spent nuclear fuel (SNF) is stored in on-site independent spent-fuel storage installations (ISFSIs) at seventythree (73) nuclear power plants (NPPs) in the US. Because a site for geologic repository for permanent disposal of SNF has not been constructed, the SNF will remain in dry storage significantly longer than planned. During this time, the ISFSIs, and potentially consolidated storage facilities, will experience earthquakes of different magnitudes. The dry storage systems are designed and licensed to withstand large seismic loads. When dry storage systems experience seismic loads, there are little data on the response of SNF assemblies contained within them. The Spent Fuel Waste Disposition (SFWD) program is planning to conduct a full-scale seismic shake table test to close the gap related to the seismic loads on the fuel assemblies in dry storage systems. This test will allow for quantifying the strains and accelerations on surrogate fuel assembly hardware and cladding during earthquakes of different magnitudes and frequency content. The main component of the test unit will be the full-scale NUHOMS 32 PTH2 dry storage canister. The canister will be loaded with three surrogate fuel assemblies and twenty-nine dummy assemblies. Two dry storage configurations will be tested – horizontal and vertical above-ground concrete overpacks. These configurations cover 91% of the current dry storage configurations. The major input into the shake table test are the seismic excitations or the earthquake ground motions – acceleration time histories in two horizontal and one vertical direction that will be applied to the shake table surface during the tests. The shake table surface represents the top of the concrete pad on which a dry storage system is placed. The goal of the ground motion task is to develop the ground motions that would be representative of the range of seismotectonic and other conditions that any site in the Western US (WUS) or Central Eastern US (CEUS) might entail. This task is challenging because of the large number of the ISFSI sites, variety of seismotectonic and site conditions, and effects that soil amplification, soil-structure interaction, and pad flexibility may have on the ground motions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Physics-Based Model to Represent Membrane-Electrode Assemblies of Solid-Oxide Fuel Cells Based on Gadolinium-Doped Ceria

This paper reports a physics-based model that predicts membrane-electrode assembly (MEA) performance of solid-oxide fuel cells (SOFCs) with Ce 0.9 Gd 0.1 O 2− δ (GDC10) electrolyte membranes. The paper derives self-consistent thermodynamic and transport properties for GDC1o mobile charged defects (oxide vacancies and reduced-ceria small polarons) by fitting published measurements of oxygen non-stoichiometry and conductivity over ranges of temperature and O 2 partial pressures. The button-cell model is applied to evaluate how mixed ionic-electronic conductivity influences the performance of an SOFC MEA with a GDC10 electrolyte sandwiched between a porous, composite Ni-GDC10 anode and a porous, composite cathode of Sm 0.5 Sr 0.5 CoO 3− δ (i.e., SSC) and GDC10. SSC properties are also derived by fitting published conductivity and oxygen non-stoichiometry measurements. Mixed conductivity of GDC10 and competing charge transfer reactions at both electrodes reduce open circuit voltages due to leakage current and buildup of defect concentrations at electrode-electrolyte interfaces. To fit polarization data, the button-cell model includes heterogeneous reaction rates for defect incorporation on the GDC10 surface along with Butler–Volmer expressions derived for competing charge transfer reaction rates from rigorous analyses assuming rate-limiting, elementary charge transfer reactions for each electrode. The calibrated MEA model can support rigorous SOFC modeling with GDC10 electrolytes over the range of conditions within a fully operating cell.

Electrochemistry↗

Numerical implementation of the MOOSE subchannel module (SCM) algorithm

The subchannel module of moose (SCM), previously referred to as Pronghorn-SC, is a subchannel code designed to resolve single-phase flow fields and calculate the relevant flow variables, in nuclear reactor fuel-pin assemblies. The assemblies it models are: water-cooled, with bare fuel-pins in a square ducted, quadrilateral lattice and liquid-metal/water-cooled, with bare/wire-wrapped fuel pins in a hexagonal ducted, triangular lattice. Previous publications have presented the development, validation and verification of SCM. This work presents an comparative overview of the different solvers implemented within SCM. This includes the solver algorithm description, and a performance comparison. The two test cases chosen to demonstrate the solver performance were taken from the PSBT enthalpy mixing benchmark and the ORNL-19 pin benchmark.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Directly driven magnetized fast-ignition targets with steep density gradients for inertial fusion energy

The development of advanced targets capable of achieving ignition with improved energy gain at lower driver energies is one of four key technical challenges to be solved in order to realize economical inertial fusion energy. We report the minimum energy necessary for a small hemispherical mass of fast-ignited high-density deuterium–tritium fuel to explosively ignite a significantly larger hemispherical mass of assembled cold fuel with much lower mass density, both with and without a flux-compressed magnetic field connecting the two regions. With the magnetic field, the burn rate improves, and lower energy states become more effective. The imploded fuel reservoir available in the lower-density, larger-mass region of the steep density gradient determines whether the fusion yield is several hundred MJ or up to a few GJ. We report a case wherein the cold reservoir ignited and produced high gain with the assistance of only ~700 kJ of hotspot yield, an amount that has already been demonstrated as feasible in laboratory experiments using indirect-drive targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Results of a preliminary experimental investigation of a vapor transport fuel pin

In-Pile experimental tests were conducted on two fuel pins mounted side-by-side in a holder assembly. The fuel pins consisted of stacked fully enriched UO2 pellets enclosed in a type 316 stainless steel clad 1/2 inch outside diameter and 3 inches in length. Each fuel pin contained four pellets for a total of 22 grams of fuel weight. The experiment was operated to maintain the maximum clad temperature at 395 K corresponding to a fuel temperature at the central void surface of 2350 K. Total primary coolant water flow past the pin holder was calculated to be 110 gallons per minute. Forty-four gallons per minute at a velocity of 36.5 feet per second flowed around each fuel pin. Calculations indicated the maximum heat flux was at the point of the highest temperature and was equal to 0.24 kW/sq cm or 7.62 Btu/hr sq ft. A series of high resolution neutron radiographs of the nuclear fueled vapor transport capsule was taken. The thermal neutrons emitted from the core of the 60 megawatt Plum Brook reactor facility were used.

Lanzo, C. D.↗

High Performance Fuel Cell and Electrolyzer Membrane Electrode Assemblies (MEAs) for Space Energy Storage Systems

Regenerative fuel cells provide a pathway to energy storage system development that are game changers for NASA missions. The fuel cell/ electrolysis MEA performance requirements 0.92 V/ 1.44 V at 200 mA/cm2 can be met. Fuel Cell MEAs have been incorporated into advanced NFT stacks. Electrolyzer stack development in progress. Fuel Cell MEA performance is a strong function of membrane selection, membrane selection will be driven by durability requirements. Electrolyzer MEA performance is catalysts driven, catalyst selection will be driven by durability requirements. Round Trip Efficiency, based on a cell performance, is approximately 65%.

Plastic Encapsulated Microelectronics (PEM)↗

Facilitated Direct Liquid Fuel Cells with High Temperature Membrane Electrode Assemblies

Dimethyl ether (DME) is a liquid fuel of great potential impact due to its exceptionally high energy density. However, it has received minimal prior investigation as an alternative to either purified hydrogen or other liquid fuels, including methanol (MeOH). In the limited published literature work on direct dimethyl ether fuel cells, regardless of operating temperature, PtRu (either supported or unsupported on carbon) has been established as the standard catalyst of choice. The majority of the work in this program also utilized a Johnson Matthey (JM) HiSPEC ® 12100 PtRu/C (nominally 50% Pt, 25% Ru) while looking at electrode optimizations, beginning of life (BoL) performance, pressure- and temperature-dependent studies to look at the effect of binding affinity of DME oxidation intermediates, mass transport effects, crossover studies, and durability. However, it does also investigate some promising alternatives to PtRu/C as well, which should be investigated in more detail in further work. Those catalysts include a pair of ternary PtRuPd/C catalysts (from Los Alamos National Laboratory (LANL) and Pajarito Powder, LLC. (PP)) as well as a Pt 2 Bi Black catalyst from Professor Anastasios Angelopoulos of the University of Cincinnati (UC). This work achieved several project objectives, including an optimization of the membrane electrode assembly (MEA) process using PtRu/C anode catalyst. Additionally, these direct dimethyl ether fuel cells (DDFCs) were able to match or exceed many performance metrics for the state-of-the-art (SOA) direct methanol fuel cells (DMFCs), a primary and more evolved competitor to direct dimethyl ether fuel cells. This included peak specific power, total platinum group metal (PGM) loading, crossover current, degradation rate, start/stop cycling losses, and anode specific current.

09 BIOMASS FUELS↗

MURR LEU structural and thermal hydraulics analyses: Part I – Preliminary irradiation thermo-mechanical behavior

The University of Missouri Research Reactor (MURR) is expected to be converted from highly enriched uranium (HEU, ≥ 20 wt% U-235) U-Al x dispersion fuel to low-enriched uranium (LEU, < 20 wt% U-235) with U-10Mo monolithic fuel. This work introduces high-fidelity irradiation thermo–mechanical (T-M) analysis of the MURR LEU focusing on changes in coolant channel gap thickness. Three-dimensional (3D) finite element (FE) models were developed to simulate the irradiation T-M behavior of the MURR LEU element with all 23 curved fuel plates, the two side plates, and the combs. It was shown that channel gap thickness changes were influenced not only by plate thickness variations due to fuel swelling and creep but also by the radial displacement of consecutive MURR LEU plates. Modeling the fuel element assembly captured side plate displacements, which were shown to reduce radial fuel plate displacements towards the convex side. The maximum local radial displacement in the element was predicted at the end of life (EOL) as 23.7 mil (602.0 µm) on the lateral centerline of plate 23 towards the convex side. The maximum stripe-averaged reduction in channel gap thickness, particularly relevant for thermal hydraulics (TH) safety analysis, was calculated as 15.9 mil (403.9 µm) in single-side heated channel 24 (the outermost channel). These results account for the thermal resistance from the oxide build-up on cladding surfaces which was shown to be up to 0.82 mil (20.8 µm) thick. It was demonstrated that accounting for oxide layer thermal resistance led to a 10 °C higher peak fuel temperature and a 4.4 mil (111.8 µm) greater maximum local radial displacement. The impact of the calculated channel gap thickness changes on the MURR LEU TH safety analysis is evaluated in Part II.

Irradiation thermo-mechanical analysis↗

Pt Nanoparticles on Atomic-Metal-Rich Carbon for Heavy-Duty Fuel Cell Catalysts: Durability Enhancement and Degradation Behavior in Membrane Electrode Assemblies

Proton exchange membrane fuel cells (PEMFCs) are a promising zero-emission power source for heavy-duty vehicles (HDVs). However, long-term durability of up to 25,000 h is challenging because current carbon support, catalyst, membrane, and ionomer developed for traditional light-duty vehicles cannot meet the stringent requirement. Therefore, understanding catalyst degradation mechanisms under the HDV condition is crucial for rationally designing highly active and durable platinum group metal (PGM) catalysts for high-performance membrane electrode assemblies (MEAs). Herein, we report a PGM catalyst consisting of platinum nanoparticles with a high content (40 wt %) on atomic-metal-site (e.g., MnN 4 )-rich carbon support. MEAs with the Pt (40 wt %)/Mn–N–C cathode catalyst achieved significantly enhanced performance and durability, generating 1.41 A cm –2 at 0.7 V under HDV conditions (0.25 mgPt cm –2 and 250 kPa abs pressure) and retaining 1.20 A cm –2 after an extended and accelerated stress test up to 150,000 voltage cycles. Electron microscopy studies indicate that most fine Pt nanoparticles are retained on or/and in the carbon support covered with the ionomer throughout the catalyst layer at the end of life. During the long-term stability test, the observed electrochemical active surface area reduction and performance loss primarily result from Pt depletion in the catalyst layer due to Pt dissolution and redeposition at the interface of the cathode and membrane. Importantly, the first-principle density functional theory calculations further reveal a support entrapment effect of the Mn–N–C, in which the MnN 4 site can specifically adsorb the Pt atom and further retard the Pt dissolution and migration, therefore enhancing long-term MEA durability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multipurpose insulation system for a radioisotope fueled Mini-Brayton Heat Source Assembly

The Mini-Brayton Heat Source Assembly (HSA) consists of a radioisotope fueled heat source, a heat exchanger, a multifoil thermal insulation blanket, and a hermetically sealed housing. The thermal insulation blanket is a multilayer wrap of thin metal foil separated by a sparsely coated oxide. The objectives of the insulation blanket are related to the effective insulation of the HSA during operation, the transfer of the full thermal inventory to the housing when the primary coolant is not flowing, and the transfer of the full thermal inventory to the housing in the event of a flow stoppage of the primary coolant. A description is given of the approaches which have been developed to make it possible for the insulation blanket to meet these requirements.

Aller, P.↗

MoVN-Cu Coatings for In Situ Tribocatalytic Formation of Carbon-Rich Tribofilms in Low-Viscosity Fuels

Inhibiting the tribological failure of mechanical assemblies which rely on fuels for lubrication is an obstacle to maintaining the lifetime of these systems with low-viscosity and low-lubricity fuels. Here in the present study, a MoVN-Cu nanocomposite coating was tribologically evaluated for durability in high- and low-viscosity fuels as a function of temperature, load, and sliding velocity conditions. The results indicate that the MoVN-Cu coating is effective in decreasing wear and friction relative to an uncoated steel surface. Raman spectroscopy, transmission electron microscopy, and electron-dispersive spectroscopy analysis of the MoVN-Cu worn surfaces confirmed the presence of an amorphous carbon-rich tribofilm which provides easy shearing and low friction during sliding. Further, the characterization of the formed tribofilm revealed the presence of nanoscale copper clusters overlapping with the carbon peak intensities supporting the tribocatalytic origin of the surface protection. The tribological assessment of the MoVN-Cu coating reveals that the coefficient of friction decreased with increasing material wear and initial contact pressure. These findings suggest that MoVN-Cu is a promising protective coating for fuel-lubricated assemblies due to its adaptive ability to replenish lubricious tribofilms from hydrocarbon environments.

36 MATERIALS SCIENCE↗

Sister Rod Destructive Examinations (FY23) Appendix F: Cyclic Integrated Reversible-Bending Fatigue Tests

Spent nuclear fuel (SNF) assemblies must be shipped to other sites for processing and disposal. During shipment, the fuel is typically oriented horizontally, and the fuel rods are subject to periodic alternating loads related to the movement of the vehicle that results in alternating bending of the SNF fuel rods. The number of bending cycles is related to the length of the shipping route, with longer routes producing more cycles. Because it is well-known that cyclic loads can produce failures, even when the stress and strain imposed are below the material’s yield point, investigation of the SNF’s fatigue behavior is prudent. This report discusses the results of fatigue testing conducted at Oak Ridge National Laboratory (ORNL) using the Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) created by the US Department of Energy Office of Nuclear Energy for the High Burnup Spent Fuel Data Project and its sister rods. The results of the tests are compared with results obtained over the last decade using the same CIRFT for the US Nuclear Regulatory Commission (NRC).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗