Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat exchanger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Low heat transfer oxidizer heat exchanger design and analysis

The RL10-IIB engine, a derivative of the RLIO, is capable of multi-mode thrust operation. This engine operates at two low thrust levels: tank head idle (THI), which is approximately 1 to 2 percent of full thrust, and pumped idle (PI), which is 10 percent of full thrust. Operation at THI provides vehicle propellant settling thrust and efficient engine thermal conditioning; PI operation provides vehicle tank pre-pressurization and maneuver thrust for log-g deployment. Stable combustion of the RL10-IIB engine at THI and PI thrust levels can be accomplished by providing gaseous oxygen at the propellant injector. Using gaseous hydrogen from the thrust chamber jacket as an energy source, a heat exchanger can be used to vaporize liquid oxygen without creating flow instability. This report summarizes the design and analysis of a United Aircraft Products (UAP) low-rate heat transfer heat exchanger concept for the RL10-IIB rocket engine. The design represents a second iteration of the RL10-IIB heat exchanger investigation program. The design and analysis of the first heat exchanger effort is presented in more detail in NASA CR-174857. Testing of the previous design is detailed in NASA CR-179487.

Kanic, P. G.↗

Effect of Adding a Regenerator to Kornhauser's MIT "Two-Space" (Gas-Spring+Heat Exchanger) Test Rig

This study employed entropy-based second law post-processing analysis to characterize the various thermodynamic losses inside a 3-space solution domain (gas spring+heat exchanger+regenerator) operating under conditions of oscillating pressure and oscillating flow. The 3- space solution domain is adapted from the 2-space solution domain (gas spring+heat exchanger) in Kornhauser's MIT test rig by modifying the heat exchanger space to include a porous regenerator system. A thermal nonequilibrium model which assumes that the regenerator porous matrix and gas average temperatures can differ by several degrees at a given axial location and time during the cycle is employed. An important and primary objective of this study is the development and application of a thermodynamic loss post-processor to characterize the major thermodynamic losses inside the 3-space model. It is anticipated that the experience gained from thermodynamic loss analysis of the simple 3-space model can be extrapolated to more complex systems like the Stirling engine. It is hoped that successful development of loss post-processors will facilitate the improvement of the optimization capability of Stirling engine analysis codes through better understanding of the heat transfer and power losses. It is also anticipated that the incorporation of a successful thermal nonequilibrium model of the regenerator in Stirling engine CFD analysis codes, will improve our ability to accurately model Stirling regenerators relative to current multidimensional thermal-equilibrium porous media models.

Ebiana, Asuquo B.↗

Design Optimization of A-Type Heat Exchangers based on High Performance, Non-Round Tubes

Air-to-refrigerant heat exchangers (HXs) have been the topic of considerable research as they are the fundamental heat transfer components of HVAC&R systems. For residential and commercial applications, indoor heat exchangers are often in A-type configurations to reduce air-conditioner system footprint while still delivering the required cooling or heating. Classical HX design practices typically assume a uniform frontal air velocity profile to facilitate the use of conventional tube-fin airside heat transfer and pressure drop correlations for performance prediction. However, it is well-reported throughout the literature that A-type HXs experience significant airflow maldistribution which can severely degrade HX performance. Additionally, recent advancements in simulation software such as Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA) and optimization algorithms have led researchers to consider primary heat transfer surface optimization to achieve highly compact HXs which do not require fins. In this paper, an A-type HX which utilizes shape-optimized non-round tubes is optimized for minimum duct size and airside pressure drop. This is achieved through coupling of an experimentally validated finite volume HX model with automated 2D CFD simulations of airflow through the HX for airside thermal-hydraulic performance evaluation. Preliminary results show that the optimal designs deliver similar capacity while achieving 20% reductions in airside pressure drop and duct cross-section area. Additionally, the optimal design apex angles in this study were similar to those from previous A-Type HX optimization studies for conventional tube-fin HX geometries, suggesting that the apex angle for optimal A-Type configuration performance may be independent of tube geometry.

42 ENGINEERING↗

Combined thermal energy storage and heat exchanger unit

The invention provides a method for storing heat and continuously generating electricity, the method comprising a phase change material; first fluid conduit in thermal communication with the phase change material wherein the first conduit is adapted to receive a first fluid; a second fluid conduit in thermal communication with the phase change material, wherein the second conduit is adapted to receive a second fluid; and a turbine in thermal communication with the second fluid. Also provided is a method for continuously charging the energy power block portion of a combined thermal energy storage and heat exchanger unit with heated fluid generated by concentrated solar power, the method comprising intermittently storing heat in a phase change material; and continually directing the heat from the phase change material to a turbine such that the phase change material buffers the turbine against inconsistent solar heat inputs.

France, David M.↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗

A Novel Approach for Bounding the Stress Experienced by the Core of Utility-Scale Printed Circuit Heat Exchangers Under Thermohydraulic Loads

Printed circuit heat exchangers (PCHEs) have rapidly gained popularity since being introduced nearly three decades ago, and they are currently widely deployed in the petrochemical and aviation industry. Their compactness, thermohydraulic efficiency, inherent suitability for high temperature/pressure fluids containment, and demonstrated durability are some of the reasons the nuclear industry is seeking to adopt this technology as well. However, the relatively strict nuclear-related regulatory design code, especially when classified as critical to the safety of the reactors, is posing challenges to adopting the technology. From stress analysis point of view, one undesirable feature of PCHEs is their geometrical complexity, which is implied by their multilength-scale features. As a result, a full-scale model of a utility-scale exchanger cannot simply be solved on a computer because meshing such components results in a vast number of degrees-of-freedom. Here, this work seeks to address the challenge of stress analyses to PCHEs by presenting a method to simplify the geometry of PCHE designs. The models proposed by this work can be practically analyzed on a standard computer and provide a path for implementing ASME design rules. The analyses presented herein are divided into five separate investigations. Each is carried out to incrementally simplify the analyzed model by addressing features such as the shapes of the flow passages, the complex distribution of stress in large components, the three-dimensionality of the stress and strain, the thermal stresses caused by thermohydraulic operation observed experimentally and more.

42 ENGINEERING↗

Bypass heat exchanger configuration to reroute core flow

A turbine engine assembly includes a heat exchanger that is in thermal communication with an exhaust gas flow. A bypass passage is provided that is configured to selectively route at least a portion of the exhaust gas flow around the heat exchanger in response to a predefined engine operating condition.

Terwilliger, Neil↗

On the Corrosion Response of Novel Heat Exchangers Manufactured by Casting of Al-Ce-Mg Alloy

Developing low-cost and durable heat exchangers is critical for next-generation heating, ventilation, air conditioning, and refrigeration systems. The emerging requirement to minimize the total refrigerant charge inventory while ensuring a uniform distribution of refrigerant has led to the deployment of advanced manufacturing strategies. At the same time, corrosion is a longstanding issue for metal components, especially those used in heat exchanger (HX) applications. In this study, Al-Ce-Mg alloy-based HXs have been investigated. The corrosion resistance of HXs prototype manufactured by the casting process has been examined and the potential of a new manufacturing approach has been explored to meet the requirements of emerging needs.

Brechtl, Jamieson↗

Laser Processed Condensing Heat Exchanger Technology Development

The reliance on non-permanent coatings in Condensing Heat Exchanger (CHX) designs is a significant technical issue to be solved before long-duration spaceflight can occur. Therefore, high reliability CHXs have been identified by the Evolvable Mars Campaign (EMC) as critical technologies needed to move beyond low earth orbit. The Laser Processed Condensing Heat Exchanger project aims to solve these problems through the use of femtosecond laser processed surfaces, which have unique wetting properties and potentially exhibit anti-microbial growth properties. These surfaces were investigated to identify if they would be suitable candidates for a replacement CHX surface. Among the areas researched in this project include microbial growth testing, siloxane flow testing in which laser processed surfaces were exposed to siloxanes in an air stream, and manufacturability.

Hansen, Scott↗

Machine learning based prediction of airflow maldistribution in air-to-refrigerant heat exchangers

Flow maldistribution is a common challenge in heat exchanger (HX) design and particularly important for air-to-refrigerant geometries where capacity losses can approach 65%. This has a major impact on central air conditioning systems, as compact duct design motivates the use of A-type HXs which are known to be affected by airflow maldistribution. Because velocity profiles are difficult to predict, components are often oversized leading to increased material cost, system footprint, and refrigerant charge. Several studies detail airflow maldistribution for individual HXs and packages, but findings cannot always be extrapolated to new designs. In this work, a machine learning (ML) based flow profile prediction framework is developed and applied to two common package configurations: (i) A-type and (ii) U-type HXs, across a broad range of HX geometries and flow rates. Porous media CFD simulations are validated against independent data for both package types as well as comprehensive in house measurements for a finless geometry with shape optimized non-round tubes, which validates the framework for new heat transfer surfaces. The ML models are trained on the porous media CFD simulations, predicting volumetric flow rate (VFR) within 1.1% and 1.9% with maximum relative L 2 norm errors of 0.48 and 0.65, respectively, while also delivering 10 5 speed up factor compared to full porous media CFD. HX level simulations show an up to 9% reduction in heat transfer from flow maldistribution, with greater losses occurring at smaller half apex angles. This framework enables rapid and highly accurate prediction of airflow maldistribution induced capacity degradation.

42 ENGINEERING↗

Comparative Analysis of Heat Exchangers for High Temperature High Pressure Helium Component Testing

Helium gas loops have been designed and built to gain a better understanding of the gas thermohydraulic phenomena that take place in a helium system. Some of these loops are used for validation and testing of components for high temperature gas-cooled reactors (HTGRs). However, most of them operate at lower pressure and temperature than an HTGR. While these loops can provide valuable information about gas-cooled reactor components, the operating envelope of the experiment is constrained by the maximum operating conditions of the helium loop. In response to the lack of an experimental facility that can provide the infrastructure needed to validate and test components at nominal pressures and temperatures of HTGRS, the HElium Component Testing Out-of-pile Research (HECTOR) facility was designed at Idaho National Laboratory with the assistance of University of Idaho and Walsh Engineering. With the capability to test at temperatures up to 800°C and pressures of 8MPa, HECTOR serves as a critical tool for the advancement of HTGR technology. The facility's primary role is to provide a controlled, high-fidelity environment for the assessment of component resilience and efficiency under nominal HTGR conditions. In the quest to enhance the efficiency and performance of HECTOR, a comparative analysis of three distinct types of heat exchangers—shell and tube, offset strip fin, and printed-circuit—was conducted, focusing primarily on two critical metrics: the required surface area and pressure drop characteristics. The shell and tube heat exchanger, renowned for its robust design and widespread industrial application, was evaluated against the offset strip fin and the cuttingedge printed-circuit heat exchangers, both of which are lauded for their compactness and thermal effectiveness. This comparative study aims to provide detailed insights into the thermal management capabilities of each heat exchanger type under the conditions inherent to HECTOR, thereby facilitating an informed selection for systems demanding high operational integrity and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A signal compensation based cascaded PI control for an industrial heat exchange system

Since the characteristics of the industrial heat exchange system (HES) are drastically affected by variations of the steam pressure, ambient temperature and water quality, it is difficult for the classical cascade PI control system to meet the desirable control objectives. Therefore, in this paper, a deterministic linear model with unmodeled dynamics is used to describe the dynamic characteristics of the HES. It should be noted that the unmodeled dynamics at the previously sampled instant can be calculated using actual measurements and that the tracking error, which includes effects of the rate of changes of unmodeled dynamics on the controlled model, can be accurately determined. An additional compensating signal is obtained with the feedforward control together with a one-step optimal control law. Consequently, the cascade PI control strategy with the signal compensation is established. Furthermore, the simulation and industrial application show that the proposed method can effectively improve the performance of the cascade PI control system, especially when the unmodeled dynamics is subjected to unknown variations.

42 ENGINEERING↗

Experimental Investigation of Melting and Solidification Processes of Phase Change Material Heat Exchanger

Rapid development and validation of PCM embedded heat exchangers (PCM-HX) concepts warrant a purpose-built test bench. This paper describes a test facility built for testing various PCM-HX configurations and phase change temperatures that will serve to validate the performance of novel PCM-HX designs. The entire test rig is placed in a temperature-controlled environmental chamber. Inside the PCM-HX containers, up to 48 T-type thermocouples can be spatially distributed on and around the tubes depending on the HX type to capture the phase change process over time. In this paper, a straight tube embedded in PCM having a phase change temperature of 37°C in cylindrical containers is tested. The PCM-HX uses water as an in-tube working fluid. Based on the measured data, the energy balance is analyzed, and its temperature distribution is presented. Here, the maximum deviation between the predicted stored energy and the energy stored calculated from experimental measurements is less than 5%.

36 MATERIALS SCIENCE↗

Modular, thermal bus-to-radiator integral heat exchanger design for Space Station Freedom

The baseline concept is introduced for the 'integral heat exchanger' (IHX) which is the interface of the two-phase thermal bus with the heat-rejecting radiator panels. A direct bus-to-radiator heat-pipe integral connection replaces the present interface hardware to reduce the weight and complexity of the heat-exchange mechanism. The IHX is presented in detail and compared to the baseline system assuming certain values for heat rejection, mass per unit width, condenser capacity, contact conductance, and assembly mass. The spreadsheet comparison can be used to examine a variety of parameters such as radiator length and configuration. The IHX is shown to permit the reduction of panel size and system mass in response to better conductance and packaging efficiency. The IHX is found to be a suitable heat-rejection system for the Space Station Freedom because it uses present technology and eliminates the interface mechanisms.

Chambliss, Joe↗