Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Poisson-response Tensor-on-Tensor Regression and Applications

We introduce Poisson-response tensor-on-tensor regression (PToTR), a novel regression framework designed to handle tensor responses composed element-wise of random Poisson-distributed counts. Tensors, or multi-dimensional arrays, composed of counts are common data in fields such as inter national relations, social networks, epidemiology, and medical imaging, where events occur across multiple dimensions like time, location, and dyads. PToTR accommodates such tensor responses alongside tensor covariates, providing a versatile tool for multi dimensional data analysis. We propose algorithms for maximum likelihood estimation under a canonical polyadic (CP) structure on the regression coefficient tensor that satisfy the positivity of Poisson parameters and then provide an initial theoretical error analysis for PToTR estimators. We also demonstrate the utility of PToTR through three concrete applications: longitudinal data analysis of the Integrated Crisis Early Warning System database, positron emission tomography (PET) image reconstruction, and change-point detection of communication patterns in longitudinal dyadic data. These applications highlight the versatility of PToTR in addressing complex, structured count data across various domains.

97 MATHEMATICS AND COMPUTING↗

3D nanolithography with metalens arrays and spatially adaptive illumination

The growing demand for advanced materials, miniaturized devices and integrated microsystems calls for the reliable fabrication of complex, multiscale, three-dimensional (3D) architectures, a need increasingly addressed through light-based and laser-based processes. However, owing to the field-of-view (FOV) limitations of conventional imaging optics, existing 3D laser nanofabrication techniques face fundamental challenges in throughput, proximity error and stitching defects on the path to scaling. Here, in this study, we present a scalable 3D nanofabrication platform that uses a metalens-generated focal spot array to parallelize two-photon lithography (TPL) beyond centimetre-scale write field areas. Metalenses are ideally suited for producing submicron-scale focal spots for high-throughput nanolithography, as they uniquely feature large numerical apertures (NAs), immersion media compatibility and large-scale manufacturability. We experimentally demonstrate a printing system that uses a 12-cm 2 metalens array to produce more than 120,000 cooperative focal spots, corresponding to a throughput exceeding 10 8 voxels s −1 . By programmatically patterning the focal spot array using a spatial light modulator (SLM), an adaptive parallel printing strategy is developed for precise greyscale linewidth modulation and choreographed printing of semiperiodic and fully aperiodic 3D geometries. We demonstrate parallel printing of replicated microstructures (>50 M microparticles per day), centimetre-scale 3D architectures with feature sizes down to 113 nm, and photonic and mechanical metamaterials. This work demonstrates the potential of 3D nanolithography towards wafer-scale production, showing how TPL could be used at scale for applications in microelectronics, biomedicine, quantum technology and high-energy laser targets.

Materials science↗

Optical and x-ray characterization of the Daedalus ultrafast x-ray imager

The Daedalus ultrafast x-ray imager is the latest generation in Sandia’s hybrid CMOS detector family. With three frames along an identical line of sight, 1 ns minimum integration time, a higher full well than Icarus, and added features, Daedalus brings exciting new capabilities to diagnostic applications in inertial confinement fusion and high energy density science. In this work, we present measurements of time response, dynamic range, spatial uniformity, pixel cross-talk, and absolute x-ray sensitivity using pulsed optical and x-ray sources. Here, we report a measured 1.5 Me — full well, pixel sensitivity at 9.58 × 10 —7 V/e — , and an estimate of spatial uniformity at ~5% across the sensor array.

47 OTHER INSTRUMENTATION↗

Striving to translate shale physics across ten orders of magnitude: What have we learned?

Shales will play an important role in the successful transition of energy from fossil-based resources to renewables in the coming decades. Aside from being a significant source of low-carbon intensity fuels, like natural gas, they also serve as geologic seals of subsurface formations that may be used to isolate nuclear waste, sequester CO 2 , or store intermittent energy (e.g., solar hydrogen). Despite their importance, shales pose significant engineering and environmental challenges due to their nanoporous structure and extreme heterogeneity that spans at least ~10 orders of magnitude in spatial scale. Two challenges inhibit a system-level understanding: (1) the physics of fluid flow and phase behavior in shales are poorly understood due to the dominant molecular interactions between minerals and fluids under confinement, and (2) the apparent lack of scale separation that prevents a reliable (closed) description of the physics at any single scale of observation. In this review, we focus on the latter issue and discuss scale translation, which in its broadest sense is transforming data or simulations from one spatiotemporal scale to another. While effective scale translation is not exclusive to shales, but all geologic porous media, the need for it is especially acute in shales given their high degree of heterogeneity. Classical theories like homogenization, while indispensable, fail when scales are not separated. Other methods, like numerical upscaling, scale-translate in only one direction: small to large, but not the reverse, called downscaling. However, the confluence of advances in three areas are bringing challenging problems such as shales within reach: increased computational power and scalable algorithms; high-resolution imaging and multi-modal data acquisition; and machine learning to process massive amounts of data. While these advances equip geoscientists with a wide array of experimental and computational tools, no individual tool can probe the entire gamut of heterogeneity in shales. Their effective use, therefore, requires an ability to bridge between various data types obtained at different scales. The aim of this review is to present a coherent account of computational and experimental methods that may be used to achieve just that, i.e., to perform scale translation. We provide a broader definition of scale translation, one that transcends classical homogenization and upscaling methods, but is consistent with them and accommodates notions like downscaling and data translation. After a brief introduction to homogenization, we review hybrid methods, numerical upscaling and its recent extensions, multiscale computing, high-resolution imaging, and machine learning. We place particular emphasis on multiscale computing and propose an algorithmic framework to bridge between the pore (micro) and Darcy (macro) scales. Throughout the paper, we draw comparisons between the various methods and highlight their (often hidden) similarities, differences, benefits, and pitfalls. We finally conclude with two case studies on shales that exemplify some of the methods presented.

58 GEOSCIENCES↗

Clutter Distributions for Tomographic Image Standardization in Ground-Penetrating Radar

Multistatic ground-penetrating radar (GPR) signals can be imaged tomographically to produce 3-D distributions of image intensities. In the absence of objects of interest, these intensities can be considered to be estimates of clutter. These clutter intensities spatially vary over several orders of magnitude and vary across different arrays, which makes a direct comparison of these raw intensities difficult. However, by gathering statistics on these intensities and their spatial variation, a variety of metrics can be determined. In this study, the clutter distribution is found to fit better to a two-parameter Weibull distribution than Gaussian or log-normal distributions. Based on the spatial variation of the two Weibull parameters, scale and shape, more information may be gleaned from these data. How well the GPR array is illuminating various parts of the ground, in depth and cross track, may be determined from the spatial variation of the Weibull scale parameter, which may in turn be used to estimate an effective attenuation coefficient in the soil. The transition in depth from clutter- to noise-limited conditions (which is one possible definition of GPR penetration depth) can be estimated from the spatial variation of the Weibull shape parameter. Lastly, the underlying clutter distributions also provide an opportunity to standardize image intensities to determine when a statistically significant deviation from background (clutter) has occurred, which is convenient for buried threat detection algorithm development that needs to be robust across multiple different arrays.

42 ENGINEERING↗

ASIC Scoping Study Final Report

This report documents the results and findings of a one-year scoping study investigating multichannel readout application specific integrated circuits (ASICs) for interfacing to, and processing data from, silicon photomultiplier (SiPM) arrays. We document ASIC desired and required specifications for four applications supporting national security mission areas: neutron radiography, associated particle imaging, and two versions of kinematic neutron imaging cameras. While each application has a few unique requirements that stress capability, there is generally good agreement among most. Two recently developed ASIC devices were evaluated in a system-like configuration by interfacing these to scintillator crystals exposed to gamma and neutron sources. The 64-channel ORNL device delivered functional capability while meeting most mission requirements for neutron radiography. The Nalu Scientific device, a 32-channel full waveform digitizer, did not demonstrate reliable neutron / gamma separation but it is unclear if this was an ASIC issue or problems with test setup or firmware. A literature survey of other commercial and academic ASICs was undertaken to with the conclusion that existing devices do not meet all requirements.

42 ENGINEERING↗

Ultrasound waveform tomography with spatial and edge regularization

Synthetic-aperture ultrasound tomography systems and methods using scanning arrays and algorithms configured to simultaneously acquire ultrasound transmission and reflection data, and process the data for improved ultrasound tomography imaging, wherein the tomography imaging comprises total-variation regularization, or a modified total variation regularization, particularly with edge-guided or spatially variant regularization.

Huang, Lianjie↗

Reconstructing the Position and Intensity of Multiple Gamma-Ray Point Sources with a Sparse Parametric Algorithm

IEEE We present an experimental demonstration of Additive Point Source Localization (APSL), a sparse parametric imaging algorithm that reconstructs the 3D positions and activities of multiple gamma-ray point sources. Using a handheld gamma-ray detector array and up to four 8 μCi 137 Cs gamma-ray sources, we performed both source-search and source-separation experiments in an indoor laboratory environment. In the majority of the source-search measurements, APSL reconstructed the correct number of sources with position accuracies of ~20 cm and activity accuracies (unsigned) of ~20%, given measurement times of two to three minutes and distances of closest approach (to any source) of ~20 cm. In source-separation measurements where the detector could be moved freely about the environment, APSL was able to resolve two sources separated by 75 cm or more given only ~60 s of measurement time. In these source-separation measurements, APSL produced larger total activity errors of ~40%, but obtained source separation distances accurate to within 15 cm. We also compare our APSL results against traditional Maximum Likelihood-Expectation Maximization (ML-EM) reconstructions, and demonstrate improved image accuracy and interpretability using APSL over ML-EM. These results indicate that APSL is capable of accurately reconstructing gamma-ray source positions and activities using measurements from existing detector hardware.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

System-on-chip approach microwave imaging reflectometer on DIII-D tokamak

System-on-chip millimeter wave integrated circuit technology is used on the two-dimensional millimeter-wave imaging reflectometer (MIR) upgrade for density fluctuation imaging on the DIII-D tokamak fusion plasma. Customized CMOS chips have been successfully developed for the transmitter module and receiver module array, covering the 55–75 GHz working band. The transmitter module has the capability of simultaneously launching eight tunable probe frequencies (>0 dBm output power each). The receiver enclosure contains 12 receiver modules in two vertical lines. The quasi-optical local oscillator coupling of previous MIR systems has been replaced with an internal active frequency multiplier chain for improved local oscillator power delivery and flexible installation in a narrow space together with improved shielding against electromagnetic interference. The 55–75 GHz low noise amplifier, used between the receiver antenna and the first-stage mixer, significantly improves module sensitivity and suppresses electronics noise. The receiver module has a 20 dB gain improvement compared with the mini-lens approach and better than –75 dBm sensitivity, and its electronics noise temperature has been reduced from 55 000 K down to 11 200 K. Further, the V-band MIR system is developed for co-located multi-field investigation of MHD-scale fluctuations in the pedestal region with W-band electron cyclotron emission imaging on DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanosecond Gated CMOS Camera (NSGCC) ICD (Rev. 2.1)

The Ultra-Fast X-ray Imager (UXI) program is an ongoing effort at Sandia National Laboratories to create high speed, multi-frame, time-gated Read Out Integrated Circuits (ROICs), and a corresponding suite of photodetectors to image a wide variety of High Energy Density (HED) physics experiments on both Sandia’s Z-Machine and LLNL’s National Ignition Facility (NIF). Several cameras have been designed over the length of the program; one of the most recent is the Icarus, which is an improvement on past imagers (Furi and Hippogriff). A second sensor that can be connected is the Daedalus sensor. The Icarus is a 1024 × 512-pixel array with either 25 μm or 8 µm spatial resolution containing four frames of storage per pixel and has improved timing generation and distribution components while achieved 2 ns time gating. The Daedalus sensor is also a 1024 x 512-pixel array with 25 µm special resolution containing three frames of storage per pixel and has an increased set of features for a wider variety of applications from interlacing of rows in each frame to configurability of all shutters. See Section 14 for details regarding the Icarus implementation of the firmware and Section 15 for details regarding the Daedalus implementation. Due to the unique test environments UXI sensors are targeted for, full custom hardware was required to physically mount an Icarus or Daedalus sensor, manage its various functions, and read out pixel data for transfer to a host computer. Beyond experimental functionality, the hardware also needed to accommodate sensor characterization requirements. Lawrence Livermore National Laboratory’s ‘Version 4.0 Board’ was the result of these efforts. It mounts all the components required to fully utilize the Icarus and Daedalus sensors including analog to digital converters to convert pixel data and various system voltages to digital form for readout and analysis, DAC channels for remote configuration of critical bias voltages, static random-access memories to buffer pixel data, RS422 and Gigabit Ethernet communications for remote access, and an FPGA to tie these components together. This document describes the FPGA electrical interfaces in detail to allow the reader a greater understanding of the device, and to facilitate implementation of custom software to control and manage it. The Version 4.0 Board is a continuation of the Nano-second Gated CMOS hardware design that retains much of the functionality of the Version 1.0 Board while adding features including a DAC instead of digital potentiometers, as well as sensors for pressure and radiation. The Version 4.0 board is intended for applications requiring tight form-factor enclosures. It is composed of two stacking boards; one holds the FPGA and regulators to power the various components of the board while the other contains the mating connector to the sensor, image-readoff ADCs, the DAC, and other components.

42 ENGINEERING↗

Selective Dynamical Imaging of Interferometric Data

Recent developments in very long baseline interferometry (VLBI) have made it possible for the Event Horizon Telescope (EHT) to resolve the innermost accretion flows of the largest supermassive black holes on the sky. The sparse nature of the EHT’s (u, v)-coverage presents a challenge when attempting to resolve highly time-variable sources. We demonstrate that the changing (u, v)-coverage of the EHT can contain regions of time over the course of a single observation that facilitate dynamical imaging. These optimal time regions typically have projected baseline distributions that are approximately angularly isotropic and radially homogeneous. We derive a metric of coverage quality based on baseline isotropy and density that is capable of ranking array configurations by their ability to produce accurate dynamical reconstructions. We compare this metric to existing metrics in the literature and investigate their utility by performing dynamical reconstructions on synthetic data from simulated EHT observations of sources with simple orbital variability. We then use these results to make recommendations for imaging the 2017 EHT Sgr A* data set.

79 ASTRONOMY AND ASTROPHYSICS↗

Angularly resolved spectral reconstruction of x rays via filter pack attenuation

We have designed a new filter pack array to measure angular variations in x-ray spectra during a single shot. The filter pack was composed of repeating identical columns of aluminum and copper filters of varying thicknesses. These columns were located at different positions to measure the spectrum at each corresponding angle. This array was utilized in an experiment to measure the energy evolution of betatron x rays in a laser wakefield accelerator by curving the wakefield with a transverse density gradient, streaking the x rays across the array in front of an x-ray charge-coupled device (CCD) camera. After subtracting the background and “flattening” the image to remove spatial nonuniformities, a critical energy was calculated for each position that produced the best agreement with the measured signal. There was a clear change in critical energy with angle, shedding light on the dynamics of the electrons that traveled through the accelerator. Furthermore, these angles correspond to distinct emission times, covering a timescale of tens of picoseconds. The filter pack was capable of recovering these angular details without the impact of errors introduced by shot-to-shot variability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

[C ιι] Map of the Molecular Ring and Arms of the Spiral Galaxy NGC 7331*

We present the [C ιι] 157.7 μm map of galaxy NGC 7331 obtained with the Field-Imaging Far-Infrared Line Spectrometer on board the Stratospheric Observatory for Infrared Astronomy (SOFIA). This map extends an existent Herschel/Photodetector Array Camera and Spectrometer observation of the central strip of the galaxy to encompass the entire molecular ring and much of the disk, including multiple spiral arms with intense far-IR emission. We also present Herschel archival data of the [N ιι] 205 μm line, which covers a substantial part of the [C ιι] SOFIA observations and allows us to estimate the neutral fraction of the [C ιι] emission along the ring and disk of the galaxy. We find that the neutral fraction rises with the distance from the center. In addition, by tracing the azimuthal variation of the neutral fraction, we are able to see how our observing perspective affects this measurement. The high inclination of NGC 7331 allows us to glimpse the internal walls of the molecular ring. There, young bright stars emit UV radiation causing more [C ιι] emission to be produced in the ionized gas. On the outer walls, opaque dust shrouds the rest of the ring, making the neutral medium the dominant source of [C ιι] emission. Through spatial analysis comparing the [C ιι] emission to tracers of gas heating, we are able to investigate how the photoelectric heating efficiency varies throughout NGC 7331 and extend global measurements of the [C ιι] deficit to local environments. Since the origin of [C ιι] emission has typically been studied in face-on galaxies, our results shed a new light on the interpretation of [C ιι] emission, especially when studying distant galaxies with unknown inclination.

79 ASTRONOMY AND ASTROPHYSICS↗

Resolving the Inner Parsec of the Blazar J1924–2914 with the Event Horizon Telescope

The blazar J1924–2914 is a primary Event Horizon Telescope (EHT) calibrator for the Galactic center’s black hole Sagittarius A*. Here we present the first total and linearly polarized intensity images of this source obtained with the unprecedented 20 μas resolution of the EHT. J1924–2914 is a very compact flat-spectrum radio source with strong optical variability and polarization. In April 2017 the source was observed quasi-simultaneously with the EHT (April 5–11), the Global Millimeter VLBI Array (April 3), and the Very Long Baseline Array (April 28), giving a novel view of the source at four observing frequencies, 230, 86, 8.7, and 2.3 GHz. These observations probe jet properties from the subparsec to 100 pc scales. We combine the multifrequency images of J1924–2914 to study the source morphology. We find that the jet exhibits a characteristic bending, with a gradual clockwise rotation of the jet projected position angle of about 90° between 2.3 and 230 GHz. Linearly polarized intensity images of J1924–2914 with the extremely fine resolution of the EHT provide evidence for ordered toroidal magnetic fields in the blazar compact core.

79 ASTRONOMY AND ASTROPHYSICS↗

Hyperspectral X-ray Imaging with TES Detectors for Nanoscale Chemical Speciation Mapping

We are developing an imaging capability (“Hyperspectral X-ray Imaging”) for mapping chemical information (molecular formula, phase, oxidation state, hydration) that is based on ultra-high-resolution X-ray emission spectroscopy with large transition-edge sensor microcalorimeter arrays in the scanning electron microscope. By combining microcalorimeter arrays with hundreds of pixels, high-bandwidth microwave frequency-division multiplexing, and fast digital electronics for near real-time data processing, our goal is to enable measurements using laboratory-scale instrumentation rather than synchrotron beamlines. Our application focus here is on mapping the chemical form of uranium compounds on the nanoscale. Furthermore, we will present our approach to developing the Hyperspectral X-ray Imaging capability, progress toward a 128-pixel microwave multiplexed X-ray fluorescence instrument at LANL, and the path to high-throughput nanoscale chemical mapping.

47 OTHER INSTRUMENTATION↗

Real Space Imaging of Field-Driven Decision-Making in Nanomagnetic Galton Boards

A possible spintronic route to hardware implementation for decision-making involves injecting a domain wall into a bifurcated magnetic nanostrip resembling a Y-shaped junction. A decision is made when the domain wall chooses a particular path through the bifurcation. Recently, it was shown that a structure like a nanomagnetic Galton board, which is essentially an array of interconnected Y-shaped junctions, produces outcomes that are stochastic and therefore relevant to artificial neural networks. However, the exact mechanism leading to the robust nature of randomness is unknown. Here, in this study, we directly image the decision-making process in nanomagnetic Galton boards using Lorentz transmission electron microscopy. We identify that the stochasticity in nanomagnetic Galton boards arises as a culmination of (1) the topology of the injected domain wall, (2) dissimilarly sized vertices, and (3) the strength of the applied field. Our results pave the way to a detailed understanding of stochasticity in nanomagnetic networks.

lorentz microscopy↗

Meso bromination and derivatization of synthetic bacteriochlorins

Here, the ability to prepare and tailor synthetic analogues of native bacteriochlorophylls enables diverse applications. A de novo route entails dimerization of a dihydrodipyrrin-acetal to afford the corresponding 5-methoxy and/or 5-unsubstituted bacteriochlorin, wherein each pyrroline ring contains a gem-dimethyl group to ensure stability toward adventitious dehydrogenation. The presence of a 5-methoxy group facilitates bromination at the distal meso-(15-)position. While bromination of 5-unsubstituted bacteriochlorins typically affords a mixture of brominated products, here the presence of two substitution patterns (2,12-dicarboethoxy, 2,12-diacetyl) has been found to facilitate selective meso-bromination in the absence of the methoxy substituent. The introduction of a single meso-bromine atom in a bacteriochlorin opens opportunities for Pd-mediated derivatization, which include (1) preparation of four ethynylphenyl building blocks (and two benchmark bacteriochlorins) with long-wavelength absorption bands tuned across 725–757 nm, for use in preparation of multichromophore arrays; (2) installation of a bioconjugatable group to free base bacteriochlorins or a copper bacteriochlorin, the latter for possible use in photoacoustic imaging; and (3) installation of an S-acetylthio group for surface attachment. Altogether, 25 new bacteriochlorins are described including 5 meso-bromobacteriochlorin intermediates and 12 target bacteriochlorins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of theory with the experimental characterization of the spatial frequency response of interferometers using a binary pseudo-random array sample

Experimental evaluations of the surface height response of an interference microscope using a binary pseudo-random array test sample are compared with a theory based on a Fourier optics model. Measurements of key instrument characteristics, including the illumination, imaging, and obscuring apertures of three different Mirau objectives, support the theoretical calculations. Agreement between experimental and theoretical modeling confirms the predictability of the spatial frequency response for the purpose of specification and optimization of instrument configuration for specific metrology tasks. The results also provide confidence in methods of compensating for the decrease in instrument response with spatial frequency.

Calibration↗