Search NASA⌕ Search

SEARCH · Search NASA

Results for “information loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

CO 2 Storage Site Screening Platform Development and CO 2 Storage Resource Analysis in SECARB Offshore Reservoirs Using SAS Viya

A major goal of the SECARB Offshore Partnership (DE-FE0031557) is to screen deep saline aquifers and hydrocarbon reservoirs in the central Gulf of Mexico for CO 2 sequestration and CO 2 -enhanced oil and gas recovery (EOR/EGR) and estimate the corresponding CO 2 storage resources for select reservoirs. CO 2 storage potential associated with offshore CO 2 -EOR is considerable and likely represents “low hanging fruit” for near-term CO 2 storage given the in-place infrastructure in the region. It is for these reasons that this assessment focuses on oil and gas fields. To this end, three major objectives have been completed and include (1) managing geological data derived from different sources, (2) building a reservoir screening platform for CO 2 storage, and (3) ranking the reservoirs based on the estimated CO 2 storage resources. The SAS ® Viya platform was used for data management and analytics. The Viya platform is a cloud service platform that provides data integration, data management, quick analytics, data visualization, machine learning functions, and application programming interfaces (APIs) for multi-programming languages. Different sources of data containing geologic information, reservoir properties, and EOR/EGR information were collected, cleaned, formatted, and loaded into the SAS ® Viya platform for evaluation. The major geological characteristics of both shelf and deep-water areas of the central Gulf were examined and compared to define the appropriate reservoir screening criteria. Next, a CO 2 storage site screening system was built in the SAS ® Viya platform with the pre-defined criteria. Finally, the CO 2 storage resources of the screened reservoirs were calculated and reported at the BOEM field level to identify fields with the highest estimated CO 2 storage resource. The fields with the largest total estimated CO 2 storage resource are located in the Mississippi Canyon protraction area. Due to proximity to the Mississippi Delta (indicative of less infrastructure) and large estimated CO 2 storage resources, future development activities may wish to focus efforts in the Mississippi Canyon protraction area.

02 PETROLEUM↗

Renewable Portfolio Standard Assessment for Alaska's Railbelt

This memorandum for the Governor of Alaska evaluates the technical feasibility of reaching 80% renewable electricity by 2040 in the Railbelt corridor of Alaska, which represents 75% of Alaska's electric load. This analysis was developed to inform renewable energy portfolio standard (RPS) legislation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Leveraging reVeal for Data Center Siting [Slides]

reVeal (the reV Extension for Analyzing Loads) is an open-source, flexible geospatial platform designed to characterize site suitability, with the goal of informing spatial downscaling and disaggregation of large-scale load projections.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 2. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable pair of chilled water cooling modules that were tested in a hot/cold aisle environment with hot aisle containment. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Takeoff certification considerations for large subsonic and supersonic transport airplanes using the Ames flight simulator for advanced aircraft

Data for use in development of takeoff airworthiness standards for new aircraft designs such as the supersonic transport (SST) and the large wide-body subsonic jet transport are provided. An advanced motion simulator was used to compare the performance and handling characteristics of three representative large jet transports during specific flight certification tasks. Existing regulatory constraints and methods for determining rotation speed were reviewed, and the effects on takeoff performance of variations in rotation speed, pitch attitude, and pitch attitude rate during the rotation maneuver were analyzed. A limited quantity of refused takeoff information was obtained. The aerodynamics, wing loading, and thrust-to-weight ratio of the subject SST resulted in takeoff speeds limited by climb (rather than lift-off) considerations. Take-off speeds based on U.S. subsonic transport requirements were found unacceptable because of the criticality of rotation-abuse effects on one-engine-inoperative climb performance. Adequate safety margin was provided by takeoff speeds based on proposed Anglo-French supersonic transport (TSS) criteria, with the limiting criterion being that takeoff safety speed be at least 1.15 times the one-engine-inoperative zero-rate-of-climb speed. Various observations related to SST certification are presented.

Snyder, C. T.↗

Analysis of fatigue, fatique-crack propagation, and fracture data

Analytical methods have been developed for consolidation of fatigue, fatigue-crack propagation, and fracture data for use in design of metallic aerospace structural components. To evaluate these methods, a comprehensive file of data on 2024 and 7075 aluminums, Ti-6A1-4V, and 300M and D6Ac steels was established. Data were obtained from both published literature and unpublished reports furnished by aerospace companies. Fatigue and fatigue-crack-propagation analyses were restricted to information obtained from constant-amplitude load or strain cycling of specimens in air at room temperature. Fracture toughness data were from tests of center-cracked tension panels, part-through crack specimens, and compact-tension specimens.

Jaske, C. E.↗

Consolidation of fatigue and fatigue-crack-propagation data for design use

Analytical methods developed for consolidation of fatigue and fatigue-crack-propagation data for use in design of metallic aerospace structural components are evaluated. A comprehensive file of data on 2024 and 7075 aluminums, Ti-6Al-4V alloy, and 300M steel was established by obtaining information from both published literature and reports furnished by aerospace companies. Analyses are restricted to information obtained from constant-amplitude load or strain cycling of specimens in air at room temperature. Both fatigue and fatigue-crack-propagation data are analyzed on a statistical basis using a least-squares regression approach. For fatigue, an equivalent strain parameter is used to account for mean stress or stress ratio effects and is treated as the independent variable; cyclic fatigue life is considered to be the dependent variable. An effective stress-intensity factor is used to account for the effect of load ratio on fatigue-crack-propagation and treated as the independent variable. In this latter case, crack-growth rate is considered to be the dependent variable. A two term power function is used to relate equivalent strain to fatigue life, and an arc-hyperbolic-tangent function is used to relate effective stress intensity to crack-growth rate.

Rice, R. C.↗

A review of the NASA V-G/VGH general aviation program

The V-G and VGH data collected from a wide variety of general aviation airplanes since the inception of the NASA V-G/VGH General Aviation Program in 1962 are presented. These data were analyzed to obtain information on the gust and maneuver loads, on the operating practices, and on the effects of different types of operations on these parameters.

Jewel, J. W., Jr.↗

Results of the second flight test of the Loran-C receiver/data collection system

The components of the Loran-C navigation system which were developed thus far are a phase-locked-loop receiver and a microcomputer development system. The microcomputer is being used as a means of testing and implementing software to handle sensor control and navigation calculations. Currently, the microcomputer is being used to collect and record data from the receiver in addition to development work. With these components, it was possible to record receiver data over a period of time and then reduce this data to obtain statistical information. It was particularly interesting to load the equipment developed in the laboratory into an aircraft and collect data while in flight. For initial flight tests, some important considerations were how well the entire system will perform in the field, signal strength levels while on the ground and in the air, the amount of noise present, changing of signal-to-noise ratio for various aircraft configurations and maneuvers, receiver overloading due to other equipment and antennas, and the overall usefulness of Loran-C as a navigation aid.

Fischer, J. P.↗

The solid state remote power controller - Its status, use and perspective

Remote power controllers (RPCs) are solid state devices that combine in one unit the capability to perform all the needed functions of load switching, overload protection, and a direct indication of whether the load is on or off. They provide total system protection of equipment and wires. RPCs are designed to be located near the load and communicate control and status information remotely via low level signals of a few milliwatts. The design and operation of the RPC are considered, taking into account the operation of an RPC, the RPC power switch and drive circuits, control and trip circuits, fail-safe devices, and RPC overcurrent protection. Attention is given to the RPC development status, RPC applications, and RPC perspectives.

Sundberg, G. R.↗

Fatigue in Composite Materials

The deformation and failure behavior of graphite/epoxy tubes under biaxial loading was investigated. The increase of basic understanding of and provide design information for the bi-axial response of graphite/epoxy composites to fatigue loads are considered.

Source record↗

A unified perspective on robot control - The energy Lyapunov function approach

A unified framework for the stability analysis of robot tracking control is presented. By using an energy-motivated Lyapunov function candidate, the closed-loop stability is shown for a large family of control laws sharing a common structure of proportional and derivative feedback and a model-based feedforward. The feedforward can be zero, partial or complete linearized dynamics, partial or complete nonlinear dynamics, or linearized or nonlinear dynamics with parameter adaptation. As result, the dichotomous approaches to the robot control problem based on the open-loop linearization and nonlinear Lyapunov analysis are both included in this treatment. Furthermore, quantitative estimates of the trade-offs between different schemes in terms of the tracking performance, steady state error, domain of convergence, realtime computation load and required a prior model information are derived.

Wen, John T.↗

Physics for the Correction of a Calibrated Airborne Scanner, Visible to Thermal Bands

To use remote sensing modalities in a reproducible manner it is essential that extraneous phenomena be removed from the signal. For those interested in the surface of the Earth, airborne and satellite systems, which are sensitive in wavelengths ranging from the visible to the infrared are significantly degraded by the atmosphere. The authors have developed a series of mathematical models to describe and correct the degradation. The models are based directly on the physics of the systems and are computationally tractable. Modeling of the atmosphere is done using public domain code, loaded with data and configured using information form systems developed by Schiller and Luvall. The results of this are then integrated with a physical model of the sensor to permit reduction of data to geophysically meaningful units. The components of the overall modeling, the logic of the components, and the limitations of the approach are discussed. The authors are employing there technology on applications ranging from measurements of urban heat islands to precision agriculture.

Rickman, Doug L.↗

Tethered Space Satellite-1 (TSS-1): Technical Roundabouts

In the early 1990's US and Italian scientists collaborated to study the electrodynamics of dragging a satellite on a tether through the electrically charged portion of Earth's atmosphere called the ionosphere. An electrical current induced in the long wire could be used for power and thrust generation for a satellite. Other tether uses include momentum exchange, artificial gravity, deployment of sensors or antennas, and gravity-gradient stabilization for satellites. Before the Tethered Space Satellite (TSS-1), no long tether had ever been flown, so many questions existed on how it would actually behave. The TSS consisted of a satellite with science experiments attached to a 12.5 mile long, very thin (0.10 inch diameter) copper wire assembly wound around a spool in the deployer reel mechanism. With the Space Shuttle at an altitude of 160 nautical miles above earth, the satellite was to be deployed by raising it from the Shuttle bay on a boom facing away from Earth. Once cleared of the bay, the deployer mechanism was to slowly feed out the 12-plus miles of tether. Scientific data would be collected throughout the operation, after which the satellite would be reeled back in. Pre-flight testing system level tests involved setting up a tether receiver to catch the 12.5 mile tether onto another reel as it was being unwound by the deployer reel mechanism. Testing only the reel mechanism is straightforward. This test becomes more complicated when the TSS is mounted on the flight pallet at Kennedy Space Center (KSC). The system level tests must be passed before the pallet can be installed into the Space Shuttle cargo bay. A few months before flight, the TSS payload had been integrated onto the Spacelab pallet and system level tests, including unreeling and reeling the tether, had been successfully completed. Some of this testing equipment was then shipped back to the contractor Martin Marietta. Systems-level load analyses, which cannot be run until all information about each payload is finalized, was run in parallel with the physical integration of the hardware into the Shuttle payload bay. The coupled loads analysis, as it is called, incorporates any updates to the model due to system level tests, and any changes that were found during integration. The coupled loads analysis revealed that a single bolt attaching the deployer reel mechanism to the support structure had a "negative margin" - which is an indication that it might fail during operation. Hardware certification rules do not allow for hardware to fly with negative margins, so this issue had to be resolved before the flight. Since there is conservatism in engineering analysis, there is an option to "waive" the margin requirement, and fly the experiment as is. On the other hand, a structural failure of one payload could have serious or catastrophic consequences to other payloads and possibly the mission. Minor design changes or fixes might be feasible within the payload bay prior to launch. Any major design changes that required the spooling test to validate the hardware, or for the pallet to be removed, would cause TSS not to be ready for the Shuttle launch.

O'Connor, Brian↗

Aerosol Absorption Retrievals from the PACE Broad Spectrum Ocean Color Instrument (OCI)

The PACE (Pre-­Aerosol, Clouds and ocean Ecosystem) mission, anticipated for launch in the early 2020s, is designed to characterize oceanic and atmospheric properties. The primary instrument on-­‐board will be a moderate resolution (approximately 1 km nadir) radiometer, called the Ocean Color Instrument (OCI). OCI will provide high spectral resolution (5 nm) from the UV to NIR (350 - 800 nm), with additional spectral bands in the NIR and SWIR. The OCI itself is an excellent instrument for atmospheric objectives, providing measurements across a broad spectral range that in essence combines the capabilities of MODIS and OMI, but with the UV channels from OMI to be available at moderate resolution. (Image credit: PACE Science Definition Team Report). Objective: Can we make use of the UV-­SWIR measurements to derive information about aerosol absorption when aerosol loading is high?

aerosols↗

Occupant Response Analysis of a Full-Scale Crash Test of a Fokker F28 Fellowship Aircraft

In this report, the capability of component fuselage testing and finite element models (FEMs) to predict occupant injury risk when applied to full-scale aircraft crash testing was evaluated. Component level and full-scale crash tests of a Fokker-F28 aircraft were performed in conjunction with representative FEM simulations. Lumbar spine injury risk, calculated through Anthropomorphic Test Device (ATD) outputs measured in the full-scale test, was compared with predictions made by component level testing and simulations. A quantitative assessment of FEM prediction accuracy was made using the International Organization for Standardization (ISO) Technical Report (TR) 16250 curve comparison methodology. Lumbar load injury risk measured in the full-scale test configuration was found to be significantly higher than in the component tests performed. The FEM provided a closer prediction of occupant injury risk than component testing but exhibited limitations in the multi-axis load environment. This work will help inform the application of component testing and FEM simulation when used to evaluate aircraft crashworthiness.

Jacob B Putnam↗