Search NASA⌕ Search

SEARCH · Search NASA

Results for “installed power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Network Models of Active Degradation Mechanisms and Pathways for Service Life Prediction of Indoor and Outdoor PV Modules

ct: PV service lifetime prediction (SLP) enables accurate calculation of levelized cost of energy (LCOE), which is crucial to rationalizing PV investment and installation. However, SLP is challeging since PV reliability in the field is affected by many combined factors, including various environmental stresses and module quality. In order to map out the active degradation mechanisms and pathways that best resemble real world conditions, we introduce the framework of a study protocol and use network models fitted to data, to enable analysis and SLP of complex PV systems with multiple active degradation mechanisms. The study protocol is the experimental design, including module variants and different exposure conditions, selection of evaluation methods, time-series data acquisition and training of network models to these data. We present SLP of minimodules in the lab and PV systems in the field. For lab SLP, minimodules with 8 variants based on manufacturer, architecture, and encapsulation were prepared and aged in modified damp heat with or without full spectrum light exposure. Stepwise I-V and Suns-Voc data acquisition tracks changes in electrical properties including Rs,IV, Isc,IV, Vmp,PIV providing insights into power loss of minimodules. Network structural equation modeling (netSEM) was utilized to construct degradation pathway models that identify active degradation mechanisms and predict power loss over time. For field SLP, datastreams of Pmp values and I-V curve datastreams of two types of modules installed in three distinctly different Köppen-Geiger climate zones for 9 years were acquired. With power loss modes corresponding to uniform current loss (ΔPIsc), recombination (ΔPVoc), series resistance (ΔPRs), and current mismatch (ΔPImis) determined, the performance loss rates (PLR) were determined using PVplr. We show how to establish a study protocol framework to ensure appropriate parametric variations and valid data collection from the variants of your complex systems. Then the data-driven netSEM model fitting provides a comprehensive mapping of multiple active degradation mechanisms, and accurate service life prediction.

network model, degradation, photovoltaic, solar↗

Performance Modeling of a Variable-Geometry Oscillating Surge Wave Energy Converter on a Raised Foundation

This paper analyzes the power capture potential, structural loadings, and costs associated with an oscillating surge wave energy converter (OSWEC) operating on a raised foundation. The raised OSWEC offers opportunities for reduced installation costs, improved energy production, and greater flexibility of deployment when compared with fixed-bottom models. In this investigation, we simulated several different foundation geometries using WEC-Sim to estimate power capture and structural loads. In an effort to maximize power capture, several cases in which flat plates of varying size were attached to the top of the foundation, under and parallel with the OSWEC, were also simulated. These plates were found to enhance power capture by preventing the wave-induced pressure from passing underneath the OSWEC, diverting this pressure toward the OSWEC instead. The OSWEC was simulated in the six Wave Energy Prize sea states, which were chosen as a representative sample of U.S. deployment sites. A first-order estimate of structural costs was calculated using the Wave Energy Prize ACE metric, with the foundation comprised predominantly of steel-reinforced concrete and the OSWEC comprised of A36 steel. Influence of foundation geometry on power capture, structural loadings, and ACE are topics of particular interest. This work has been inspired by advances in large-scale additive manufacturing techniques that have the potential to dramatically reduce the cost of subsea foundations. These advancements may enable cost-effective WEC systems to be deployed on raised foundations.

cost↗

Performance Modeling of a Variable-Geometry Oscillating Surge Wave Energy Converter on a Raised Foundation: Preprint

This paper analyzes the power capture potential, structural loadings, and costs associated with an oscillating surge wave energy converter (OSWEC) operating on a raised foundation. The raised OSWEC offers opportunities for reduced installation costs, improved energy production, and greater flexibility of deployment when compared with bottom-fixed models. In this investigation, several different foundation geometries were simulated using WEC-Sim to estimate power capture and structural loads. In an effort to maximize power capture, several cases in which flat plates of varying size were attached to the top of the foundation, under and parallel with the OSWEC, were also simulated. These plates were found to enhance power capture by preventing the wave induced pressure from passing underneath the OSWEC, diverting this pressure towards the OSWEC instead. The OSWEC was simulated in the six Wave Energy Prize sea states, which were chosen as a representative sample of U.S. deployment sites. A first-order estimate of structural costs was calculated using the Wave Energy Prize ACE metric, with the foundation comprised predominantly of steel-reinforced concrete and the OSWEC comprised of A36 steel. Influence of foundation geometry on power capture, structural loadings, and ACE are topics of particular interest. This work has been inspired by advances in large scale additive manufacturing techniques that have the potential to dramatically reduce the cost of subsea foundations. These advancements may enable cost effective WEC systems to be deployed on raised foundations.

50 EE - Wind and Water Power Program - Water (EE-4↗

A machine learning approach for particle accelerator errant beam prediction using spatial phase deviation

Particle accelerators are extremely complex systems that are expected to operate on high availability. Predicting impending failures only by utilizing data collected from diagnostic equipment already on board can help operators to avoid installing expensive sensors, unscheduled downtime and associated costs. For this purpose we explore the predictive power of Machine Learning algorithms to detect faulty beams prior to the failure. In this study, we propose a Machine Learning approach to model mapping from a pair of sensors located across the accelerator. While the model is trained to represent normal operation, we evaluate the predictive performance on known faulty beam pulses. We also investigate the model performance on unseen data through k-fold cross-validation. Then we recap the analysis with a neural architecture search and hyperparameter optimization study to fine tune our initial model. In conclusion, this paper will also introduce a sustainable framework that can standardize Machine Learning workflow applied to particle accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A geospatial environmental and techno-economic framework for sustainable phosphorus management at livestock facilities

Nutrient pollution of waterbodies is a major worldwide water quality problem. Excessive use and discharge of nutrients can lead to eutrophication and algal blooms in fresh and marine waters, resulting in environmental problems associated with hypoxia, public health issues related to the release of toxins and freshwater scarcity. A promising option to address this problem is the recovery of nutrient releases prior to being discharged into the environment. Driven by the sustainable materials management concept, the COW2NUTRIENT (Cattle Organic Waste to NUTRIent and ENergy Technologies) framework is developed for the techno-economic evaluation and selection of nutrient recovery systems at livestock facilities. Furthermore, environmental vulnerability to nutrient pollution determined through a geographic information system (GIS)-based model and techno-economic information of different state-of-the-art nutrient management technologies are combined in a multi-criteria decision analysis (MCDA) model, resulting in the selection and economic analysis of the most suitable process for each studied livestock facility. This framework has been employed for studying the implementation of sustainable phosphorus management systems at 2,217 livestock facilities in the Great Lakes area, resulting in capital expenses of 2.5 billion USD if only phosphorus recovery technologies are installed, and up to 5.2 billion USD if nutrient management is combined with biogas and power production. However, considering potential economic incentives for the recovery of phosphorus, net revenues up to 230 million USD per year can be achieved. Therefore, the framework presented reveals the potential of implementing nutrient management systems at regional scale for the abatement of phosphorus releases from livestock facilities.

54 ENVIRONMENTAL SCIENCES↗

Adiabatic Cooling System Spreadsheet Model for sCO 2

The attached cost and performance spreadsheet model is for an adiabatic cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO 2 (sCO 2 ) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Direct Dry Cooling System Spreadsheet Model for sCO 2

The attached cost and performance spreadsheet model is for a direct dry cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO 2 (sCO 2 ) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Indirect Dry Cooling System Spreadsheet Model for sCO2

The attached cost and performance spreadsheet model is for an indirect dry cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO2 (sCO2) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Wet Cooling Tower Cooling System Spreadsheet Model for sCO2

The attached cost and performance spreadsheet model is for a wet cooling tower system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO2 (sCO2) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Background Information on the Protection Requirements in IEEE Std 1547-2018

As the DER penetration level has risen significantly in recent times, parameter settings and configuration of installed DERs are having direct impact on local electric distribution utilities as well as bulk power systems during normal and abnormal grid conditions. On the other hand, all grid-connected DERs in the United States of America must conform to the interconnection requirements prescribed in the IEEE Std 1547-2018. Because of these reasons, it is crucial to understand the expected DER performance during abnormal grid conditions considering the requirements of the IEEE Std 1547-2018. The aim of this document is twofold: (1) to summarize requirements in IEEE Std 1547-2018 having direct implications in distribution network protection, and (2) to provide the reader with knowledge and information that will be required for users to apply the requirements specified. Since the focus of this document is on distribution network protection in the presence of DERs, it is assumed that the readers have basic understanding of distribution network protection as well as working principles of DERs. This document starts with a brief introduction on protection systems for distribution network followed by a discussion on the impact of DER on the protection systems. Current practices to provide network protection in the presence of DER is briefly discussed. The document then explores the DER performance requirements in IEEE Std. 1547-2018; especially on those related to distribution network protection. Section 6.1 in IEEE Std. 1547-2018 provides an overview of capabilities and control requirements for DER under abnormal operating conditions. This section also introduces abnormal operating performance categories I, II, III. The DER response to various types of faults and grid conditions such as short-circuit faults and open phase conditions are discussed in section 6.2 in the standard while requirements for coordination with the Area EPS reclosing scheme are provided in section 6.3. Section 6.4 in the IEEE Std 1547-2018 specifies requirements for mandatory voltage tripping and ride-through requirements during low and high voltage disturbances and section 6.5 specifies similar requirements for low and high frequency disturbances. IEEE Std. 1547 requires that the conformance of the DERs to IEEE Std 1547-2018 requirements should be verified in accordance with IEEE Std. 1547. 1. There are several parameters and settings of DERs that need to be properly selected for reliable operation during abnormal grid condition while applying the requirements of IEEE Std 1547-2018. Key decisions for proper selections of parameter and settings are: 1. Determination of required DER abnormal operating performance category, 2. Determination of DER response (shall trip) to abnormal voltages and 3. Determination of DER response (shall trip) to abnormal frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Planning, Procuring, & Constructing on-site PV [Slides]

A developer will install a renewable energy system on DOE property. In exchange, DOE agrees to purchase the power generated by the system. These power purchase payments repay the developer over the contract term. The developer owns, operates, and maintains the system for the life of the contract.

14 SOLAR ENERGY↗

COZMIC. III. Cosmological Zoom-in Simulations of Self-interacting Dark Matter with Suppressed Initial Conditions

We present eight cosmological dark matter (DM)-only zoom-in simulations of a Milky Way–like system that include suppression of the linear matter power spectrum P(k), and/or velocity-dependent DM self-interactions, as the third installment of the COZMIC suite. We consider a model featuring a massive dark photon that mediates DM self-interactions and decays into massless dark fermions. The dark photon and dark fermions suppress linear matter perturbations, resulting in dark acoustic oscillations in P(k), which ultimately affect dwarf galaxy scales. The model also features a velocity-dependent elastic self-interaction between DM particles (SIDM), with a cross section that can alleviate small-scale structure anomalies. For the first time, our simulations test the impact of P(k) suppression on gravothermal evolution in an SIDM scenario that leads to core collapse in (sub)halos with present-day virial masses below ≈10 9 M ⊙ . In simulations with P(k) suppression and self-interactions, the lack of low-mass (sub)halos and the delayed growth of structure reduce the fraction of core-collapsed systems relative to SIDM simulations without P(k) suppression. In particular, P(k) suppression that saturates current warm DM constraints almost entirely erases core collapse in isolated halos. Models with less extreme P(k) suppression produce core collapse in ≈20% of subhalos and ≈5% of isolated halos above 10 8 M ⊙ , and also increase the abundance of extremely low-concentration isolated low-mass halos relative to SIDM. These results reveal a complex interplay between early and late-Universe DM physics, revealing new discovery scenarios in the context of upcoming small-scale structure measurements.

dark matter↗

FY20, 3rd Quarter, Multi-pass Hybrid Laser Arc Welding of Alloy 740H

Although progress has been slowed by telecommuting restrictions at INL and PSU, progress has been made by PSU on modeling and simulation of deep penetration laser welding. Additionally, both INL and PSU has received critical equipment, in the form of high-powered laser wobble heads, needed to verify the modeling and simulation results. The equipment was installed at INL and preliminary tests, based on a test matrix that was developed in this 3rd quarter, will be made early in the 4th quarter. Similarly, the PSU laser wobble head is expected to be installed early in the 4th quarter and preliminary experiments are expected to commence shortly thereafter. Completion dates on a few milestones have been impacted and new dates proposed.

36 MATERIALS SCIENCE↗

The Future of Renewable Energy Transmission: An Autonomous Energy Grid

The drastic price reduction in variable renewable energy, such as wind and solar, coupled with the ease of use of smart technologies at the consumer level, is driving dramatic changes to the power system that will significantly transform how power is made, delivered, and used. Distributed energy resources (DERs)—which can include solar photovoltaic (PV), fuel cells, microturbines, gensets, distributed energy storage (e.g., batteries, ice storage), and new loads (e.g., electric vehicles (EVs), light-emitting diode (LED) lighting, smart appliances, and electric heat pumps)—are being added to electric grids and causing bidirectional power flows and voltage fluctuations that can impact optimal control and system operation. Residential solar installations, customer battery systems, and EVs are all seeing rapid increases in deployments. With DER seeing such increased use, it is not unreasonable to imagine a residential electricity customer having at least five controllable DERs. In future electric grids, as more DERs are integrated, the number of active control points will be too much for current control approaches to effectively manage.

30 DIRECT ENERGY CONVERSION↗

Solar Photovoltaics Resilient Fasteners Levelized Cost of Energy (LCOE) Tool

Solar photovoltaics (PV) module fasteners are one of the most common structural failure points on PV systems, particularly in high winds and coastal areas with ocean spray. Some fastener types have been shown to survive these conditions at higher rates than others. The fastener type, material, quantity, and placement all impact performance. Fasteners that fail less often typically have a higher upfront cost, but this investment can pay off in savings from less frequent torque audits (which reduces O&M costs), reduced system damage, and decreased system downtime. We developed an Excel-based tool to evaluate different module fasteners for a PV system - either a new or retrofit project - and compare differences in upfront and outyear costs to determine the expected life cycle costs and simple payback periods of different fastener options. The tool is site-specific, with inputs including system attributes (such as system size, location, price of power) and fastener attributes (such as design, washer type, nut type, use of locking hardware, materials, installation time, and torque audit requirements). A baseline fastener scenario can be compared to up to four proposed fastener scenarios. In addition to presenting expected life cycle cost implications of the different fastener options, the tool produces results showing the reductions in outyear costs needed to offset any initial cost premiums for more reliable fasteners across four categories: preventative O&M, avoided damage, reduced downtime, and reduced insurance premiums. These numbers can serve as decision aids for users when considering fastener options on new or existing projects. This poster will present the tool, methodology, and scenarios using example sites to highlight the tool capabilities and how it can inform different fastener decisions on different projects. Future work includes incorporating lifetime expected damage costs by embedding damage function curves that the authors are developing from field data.

14 SOLAR ENERGY↗

Climate change impacts on wind power generation

Wind energy is a virtually carbon-free and pollution-free electricity source, with global wind resources greatly exceeding electricity demand. Accordingly, the installed capacity of wind turbines grew at an annualized rate of >20% from 2000 to 2019 and is projected to increase by a further 50% by the end of 2023. Here, in this Review, we describe the factors that dictate the wind resource magnitude and variability and illustrate the tools and techniques that are being used to make projections of wind resources and wind turbine operating conditions. Natural variability due to the action of internal climate modes appears to dominate over global-warming-induced non-stationarity over most areas with large wind energy installations or potential. However, there is evidence for increased wind energy resources by the end of the current century in northern Europe and the US Southern Great Plains. New technology trends are changing the sensitivity of wind energy to global climate non-stationarity and, thus, present new challenges and opportunities for innovative research. The evolution of climate modelling to increasingly address mesoscale processes is providing improved projections of both wind resources and wind turbine operating conditions, and will contribute to continued reductions in the levelized cost of energy from wind power generation.

17 WIND ENERGY↗

Validation of Interconnection and Interoperability of Grid-Forming Inverters Sourced by Hydrogen Technologies in View of 100% Renewable Microgrids

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

grid-forming↗

Summary Paper: An Initial Heliostat Supply Chain Analysis

This paper summarizes the prior analysis, key findings, and recommendations from the published report titled “Initial Heliostat Supply Chain Analysis” [1]. Globally, the growing demand for concentrating solar power (CSP) technologies, primarily for electricity generation plants has been met with supply chains primarily composed of plentiful commodity materials such as steel, aluminum, and glass. Often the commodity materials can be sourced in the domestic market where power plant will be constructed. Although specialty components are required for CSP solar fields —including mirror panels used for heliostat applications—these specialty components constitute about 30-50% of total system installed costs [2]. Only a few companies and countries, including the United States, have developed the capacity to supply such specialty components. The U.S. heliostat supply chain at present is comprised of few companies (e.g., CSP developers), component suppliers, and is its infancy. By 2035, with current and aggressive solar photovoltaic (PV) capacity expansions, there is the potential for 500,000–1,500,000 direct and indirect jobs in the areas of manufacturing, installation and development, and operations and maintenance (O&M) [3]. Utilizing the CSP capacity estimations the recent NREL report [4], the construction of 39 gigawatts (GW) of CSP (assuming mainly power tower) in the U.S. could lead to approximately 195,000 manufacturing, construction, and O&M jobs. This does not include the longer-term jobs and economic impact (e.g., taxes from plant operations staff) from operating the plants once constructed. It is recommended that further CSP component and system supply chain analysis and modelling be undertaken.

Kurup, Parthiv (ORCID:0000000217356703)↗