Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrument designs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The Deflection Plate Analyzer: A Technique for Space Plasma Measurements Under Highly Disturbed Conditions

A technique has been developed to measure the characteristics of space plasmas under highly disturbed conditions; e.g., non-Maxwellian plasmas with strong drifting populations and plasmas contaminated by spacecraft outgassing. The present method is an extension of the capabilities of the Differential Ion Flux Probe (DIFP) to include a mass measurement that does not include either high voltage or contamination sensitive devices such as channeltron electron multipliers or microchannel plates. This reduces the complexity and expense of instrument fabrication, testing, and integration of flight hardware as compared to classical mass analyzers. The new instrument design is called the Deflection Plate Analyzer (DPA) and can deconvolve multiple ion streams and analyze each stream for ion flux intensity (density), velocity (including direction of motion), mass, and temperature (or energy distribution). The basic functionality of the DPA is discussed. The performance characteristics of a flight instrument as built for an electrodynamic tether mission, the Propulsive Small Expendable Deployer System (ProSEDS), and the instrument s role in measuring key experimental conditions are also discussed.

Wright, Kenneth H., Jr.↗

The Deflection Plate Analyzer: A Technique for Space Plasma Measurements Under Highly Disturbed Conditions

A technique has been developed to measure the characteristics of space plasmas under highly disturbed conditions; e.g., non-Maxwellian plasmas with strong drifting populations and plasmas contaminated by spacecraft outgassing. The present method is an extension of the capabilities of the Differential Ion Flux Probe (DIFP) to include a mass measurement that does not include either high voltage or contamination sensitive devices such as channeltron electron multipliers or microchannel plates. This reduces the complexity and expense of instrument fabrication, testing, and integration of flight hardware as compared to classical mass analyzers. The new instrument design is called the Deflection Plate Analyzer (DPA) and can deconvolve multiple ion streams and analyze each stream for ion flux intensity (density), velocity (including direction of motion), mass, and temperature (or energy distribution). The basic functionality of the DPA is discussed. The performance characteristics of a flight instrument as built for an electrodynamic tether mission, the Propulsive Small Expendable Deployer System (ProSEDS), and the instrument s role in measuring key experimental conditions are also discussed.

Wright, Kenneth H., Jr.↗

The Primordial Inflation Polarization Explorer (PIPER)

The Primordial Inflation Polarization Explorer (PIPER) is a ba1loon-borne instrument designed to search for the faint signature of inflation in the polarized component of the cosmic microwave background (CMB). PIPER will measure the CMB polarization at 4 frequencies (l per flight) using a pair of cryogenic telescopes, one for measuring each of Stokes Q and U in the instrument frame. Each telescope receives both linear orthogonal polarizations in two 32 by 40 element planar arrays that utilize Transition-Edge Sensors (TES). The first element in each telescope is a variable-delay polarization modulator (VPM) that fully modulates the Stokes parameter to which the telescope is sensitive.

Chuss, David T.↗

A low energy electron magnetometer

The concept of a highly sensitive magnetometer based on the deflection of low energy electron beams in magnetic fields is analyzed. Because of its extremely low mass and consequently high e/m ratio, a low energy electron is easily deflected in a magnetic field, thus providing a basis for very low field measurement. Calculations for a specific instrument design indicate that a low energy electron magnetometer (LEEM) can measure magnetic fields as low as 1000 nT. The anticipated performance of LEEM is compared with that of the existing high resolution magnetometers in selected applications. The fast response time of LEEM makes it especially attractive as a potential instrument for magnetic signature analysis in large engineering systems.

Singh, J. J.↗

(abstract) Galileo PPR Observations of Shoemaker-Levy 9

The Galileo spacecraft Photopolarimeter Radiometer (PPR), a hybrid visual/thermal IR instrument designed primarily to measure properties of the Jovian atmosphere, was employed for SL9 as a staring high-speed photometer at 945 and 678 nm, taking advantage of Galileo's direct view of the impact point.The PPR was able to acquire data at times when no other Galileo optical instruments could operate.

Galileo Jupiter Shoemaker-Levy 9 IR observations p↗

Polar Mesospheric Clouds (PMCs) Observed by the Ozone Monitoring Instrument (OMI) on Aura

Backscattered ultraviolet (BUV) instruments designed for measuring stratospheric ozone profiles have proven to be robust tools for observing polar mesospheric clouds (PMCs). These measurements are available for more than 30 years, and have been used to demonstrate the existence of long-term variations in PMC occurrence frequency and brightness. The Ozone Monitoring Instrument (OMI) on the EOS Aura satellite provides new and improved capabilities for PMC characterization. OMI uses smaller pixels than previous BUV instruments, which increases its ability to identify PMCs and discern more spatial structure, and its wide cross-track viewing swath provides full polar coverage up to 90 latitude every day in both hemispheres. This cross-track coverage allows the evolution of PMC regions to be followed over several consecutive orbits. Localized PMC variations determined from OMI measurements are consistent with coincident SBUV/2 measurements. Nine seasons of PMC observations from OMI are now available, and clearly demonstrate the advantages of these measurements for PMC analysis.

DeLand, Matthew T.↗

Acousto-optic infrared spectral imager for Pluto fast flyby

Acousto-optic tunable filters (AOTF's) enable the design of compact, two-dimensional imaging spectrometers with high spectral and spatial resolution and with no moving parts. Tellurium dioxide AOTF's operate from about 400 nm to nearly 5 microns, and a single device will tune continuously over one octave by changing the RF acoustic frequency applied to the device. An infrared (1.2-2.5 micron) Acousto-Optic Imaging Spectrometer (AImS) was designed that closely conforms to the surface composition mapping objectives of the Pluto Fast Flyby. It features a 75-cm focal length telescope, infrared AOTF, and 256 x 256 NICMOS-3 focal plane array for acquiring narrowband images with a spectral resolving power (lambda/delta(lambda)) exceeding 250. We summarize the instrument design features and its expected performance at the Pluto-Charon encounter.

Glenar, D. A.↗

Stellar and solar X-ray polarimetry

Astronomical stellar and solar studies involving X-ray polarimetry are discussed along with the statistical limitations inherent in polarimeter measurements and the design principles of a number of polarimeter types. Attention is given to photoelectric polarimeters, secondary fluorescence X-ray polarimeters, Borrmann-effect polarimeters, circular polarization analyzers, gamma-ray polarimeters, and multilayer reflection polarimeters. Bragg crystal polarimeters are considered, taking into account the theory of the polarimeter operation, aspects of instrument design, and the occurrence of systematic errors. The design and the performance of a rocket and a satellite Thomson-scattering polarimeter are also examined.

Novick, R.↗

Development of Transition Edge Sensor Detectors Optimized for Single-Photon Spectroscopy in the Optical and Near-Infrared

The search for biosignatures in the atmospheres of exoplanets will be a key focus of future space telescopes that operate in the ultraviolet, visible, and near-infrared bands. Detection of biosignatures requires an instrument with moderate spectral resolving power ($R \sim 100$) and a large bandwidth ($\sim 400$ nm -- $\sim 1.8$ $\mu$m). Additionally, biosignature detection is a photon-starved science; instruments designed for these measurements would ideally combine high optical efficiency with quantum-limited photon detectors (i.e., detectors that exhibit zero dark current). In this work, we report on our efforts to develop energy resolving transition edge sensor (TES)-based detectors designed for biosignature detection. TESs operated as microcalorimeters are compelling detectors for this application. Unlike semiconductor detectors, TESs eliminate the need for dispersive optics and are truly single photon detectors -- fundamental TES noise yields uncertainty in the energies of detected photons, not in the number of detected photons. We introduce TESs designed for this application and discuss the path toward realizing a TES-based dispersionless spectrometer optimized for biosignature detection.

Instrumentation and Photography↗

Background suppression techniques in germanium detectors

A new generation of astrophysical gamma ray spectrometers employing germanium solid state detectors for precise energy measurement are currently being planned for spaceflight in the late 1990's and the early 21st century. Because the observations of weak celestial sources are carried out in an intense radiation environment, the key objective of instrument design is to find ways to reduce the background. The current state of the knowledge in this field is reviewed and the new hardware techniques under design and test are discussed. Many of these techniques have already been flight tested on balloon platforms. Recent results from some of these tests are presented. By carefully applying these techniques it should be possible to achieve sensitivities that are factors of 3 to 10 better than would be obtained for a conventional instrument of similar weight.

Gehrels, Neil↗

The Gamma-ray Large Area Space Telescope (GLAST) Mission Concept Study

The Gamma-ray Large Area Space Telescope (GLAST), a next generation high-energy gamma-ray mission designed to observe cosmic sources of gamma-rays over the approximate energy range from 10 MeV to 300 GeV, was studied for possible flight in the next decade. The GLAST baseline mission studied will achieve a major advance in sensitivity beyond EGRET by the use of modern particle physics tracking technology. The baseline instrument design that has been extensively studied uses solid-state silicon strip detectors for particle tracking and efficient on-board data processing and event triggering to achieve more than an order of magnitude improvement in sensitivity compared to EGRET. Development of technology requirements and a technology development roadmap for the GLAST mission is presented.

Michelson, Peter F.↗

Comparison of Classical and Charge Storage Methods for Determining Conductivity of Thin Film Insulators

Conductivity of insulating materials is a key parameter to determine how accumulated charge will distribute across the spacecraft and how rapidly charge imbalance will dissipate. Classical ASTM and IEC methods to measure thin film insulator conductivity apply a constant voltage to two electrodes around the sample and measure the resulting current for tens of minutes. However, conductivity is more appropriately measured for spacecraft charging applications as the "decay" of charge deposited on the surface of an insulator. Charge decay methods expose one side of the insulator in vacuum to sequences of charged particles, light, and plasma, with a metal electrode attached to the other side of the insulator. Data are obtained by capacitive coupling to measure both the resulting voltage on the open surface and emission of electrons from the exposed surface, as well monitoring currents to the electrode. Instrumentation for both classical and charge storage decay methods has been developed and tested at Jet Propulsion Laboratory (JPL) and at Utah State University (USU). Details of the apparatus, test methods and data analysis are given here. The JPL charge storage decay chamber is a first-generation instrument, designed to make detailed measurements on only three to five samples at a time. Because samples must typically be tested for over a month, a second-generation high sample throughput charge storage decay chamber was developed at USU with the capability of testing up to 32 samples simultaneously. Details are provided about the instrumentation to measure surface charge and current; for charge deposition apparatus and control; the sample holders to properly isolate the mounted samples; the sample carousel to rotate samples into place; the control of the sample environment including sample vacuum, ambient gas, and sample temperature; and the computer control and data acquisition systems. Measurements are compared here for a number of thin film insulators using both methods at both facilities. We have found that conductivity determined from charge storage decay methods is 102 to 104 larger than values obtained from classical methods. Another Spacecraft Charging Conference presentation describes more extensive measurements made with these apparatus. This work is supported through funding from the NASA Space Environments and Effects Program and the USU Space Dynamics Laboratory Enabling Technologies Program.

Swaminathan, Prasanna↗

NASA's Orbital Debris Optical and IR Ground-Based Observing Program Utilizing the MCAT, UKIRT, and Magellan Telescopes

Characterizing debris in Earth-orbit has become increasingly important as the population growth rises steadily, posing greater and greater threats to active satellites with each passing year. Currently, the Joint Space Operations is tracking over 23,000 pieces of debris, ranging in size from 1-meter and larger in geosychronous orbits (GEO) to 10-cm and larger at low-Earth orbits (LEO). Model estimates suggest that there may be more than 500,000 pieces of spacecraft debris larger than 1 cm currently in orbit around the Earth. With such a small fraction of the total population being tracked, and new break-ups occurring in LEO, GEO, and Geo Transfer Orbits, new assets, techniques, and approaches for characterizing this debris are needed. With this in mind, NASA's Orbital Debris Program Office has actively tasked a suite of telescopes around the world. In 2015, the newly-built 1.3m optical Meter Class Autonomous Telescope (MCAT) came on-line on Ascension Island in the South Atlantic Ocean and is currently in its commissioning phase. MCAT is designed to track Earth-orbiting objects above 200km, conduct surveys at GEO, and work in tandem with a newly-installed Raven-class commercial-off-the-shelf system, a 0.4-meter telescope co-located on Ascension with a field-of-view similar to MCAT's and research-grade instrumentation designed to complement MCAT for observations taken either simultaneously or in tandem. The 3.8m infrared UKIRT telescope on Mauna Kea, Hawaii, has been heavily tasked throughout 2015 and into 2016, collecting data on individual targets as well as in survey modes to study both the general GEO population as well as an individual break-up event of a BRIZ-M Rocket body that occurred in January 2016. Data collected include photometry and spectroscopy in the near-Infrared (0.85-2.5 m) and the mid-infrared (8-16 m). Finally, the 6.5-m Baade Magellan telescope at Las Campanas Observatory in Chile was used to collect optical photometric survey data in October 2015 of two GEO Titan breakups, focusing on locations of possible debris concentrations as indicated by the NASA standard break-up model.

Lederer, Susan↗

The Primordial Inflation Polarization Explorer (PIPER)

The Primordial Inflation Polarization Explorer (PIPER) is it balloon-borne instrument designed to search for the faint signature of inflation in the polarized component of the cosmic microwave background (C-N-113). Each flight will be configured for a single frequency, but in order to aid in the removal of the polarized foreground signal due to Galactic dust, the filters will be changed between flights. In this way, the CMB polarization at a total of four different frequencies (200, 270, 350, and 600 GHz) will be, measured on large angular scales. PIPER consists of a pair of cryogenic telescopes, one for measuring each of Stokes Q and U in the instrument frame. Each telescope receives both linear orthogonal polarizations in two 32 x 40 element planar arrays that utilize Transition-Edge Sensors (TES). The first element in each telescope is a variable-delay polarization modulator (VPM) that fully modulates the linear Stokes parameter to which the telescope is sensitive. There are several advantages to this architecture. First, by modulating at the front of the optics, instrumental polarization is unmodulated and is therefore cleanly separated from source polarization. Second, by implementing this system with the appropriate symmetry, systematic effects can be further mitigated. In the PIPER design, many of the. systematics are manifest in the unmeasured linear Stokes parameter for each telescope and this can be separated from the desired signal. Finally, the modulation cycle never mixes the Q and U linear Stokes parameters, and thus residuals in the modulation do not twist the observed polarization vector. This is advantageous because measuring the angle of linear polarization is critical for separating the inflationary signal from other polarized components.

Chuss, David T.↗

Model Validation of Phase-Induced Amplitude Apodization Complex Mask Coronagraph for LUVOIR-A in Vacuum

The Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC) is a coronagraph architecture for the next generation of large space telescopes optimized for habitable exoplanet imaging that can achieve attractive theoretical performance with high throughput at small inner working angles (IWA). PIAACMC designs are compatible with large, on-axis, segmented apertures such as the Large UV / Optical/ Infrared A (LUVOIR-A) concept currently being considered by the decadal survey review which would greatly enhance the possibility to achieve statistically significant scientific yields and signal quality for direct imaging exoplanet surveys. PIAACMC has been recently implemented for LUVOIR-A and is currently being tested in vacuum at JPL’s High-Contrast Imaging Testbed (HCIT). In this work, we review the theoretical performance of the PIAACMC instrument designed to meet a 1e-9 raw contrast goal in 10% broadband light in a region from 2-8 L/D both before and after the wavefront control loop. We use empirical measurements from the vacuum testbed to verify the instrument model and its performance including line-of-sight errors, instrument alignment, and fabricated components. In particular, the model verification includes measured sags of the manufactured PIAA mirrors by NuTek. The CMC mask was manufactured at JPL’s Microdevices Laboratory and we include surface profile characterization measurement. We assess the impact on performance of the different manufacturing and alignment errors.

High-Contrast Imaging↗

Instrument manual for the retarding ion mass spectrometer on Dynamics Explorer-1

The retarding ion mass spectrometer (RIMS) for Dynamics Explorer-1 is an instrument designed to measure the details of the thermal plasma distribution. It combines the ion temperature determining capability of the retarding potential analyzer with the compositional capabilities of the mass spectrometer and adds multiple sensor heads to sample all directions relative to the spacecraft ram direction. This manual provides a functional description of the RIMS, the instrument calibration, and a description of the commands which can be stored in the instrument logic to control its operation.

Fields, S. A.↗

A retarding ion mass spectrometer for the Dynamics Explorer-1

The Retarding Ion Mass Spectrometer (RIMS) for Dynamics Explorer-1 is an instrument designed to measure the details of the thermal plasma distribution. It combines the ion temperature determining capability of the retarding potential analyzer with the compositional capabilities of the mass spectrometer and adds multiple sensor heads to sample all directions relative to the spacecraft ram direction. This manual provides a functional description of the RIMS, the instrument calibration, and a description of the commands which can be stored in the instrument logic to control its operation.

Wright, W.↗

RFI at L-band in Synthetic Aperture Radiometers

The spectral window at 1.413 GHz (L-band), set aside for passive use only, is critical for passive remote sensing of the earth from space. It is the largest spectral window available in the long wavelength end of the microwave spectrum where measurements are needed to monitor parameters of the surface such as soil moisture and sea surface salinity. The sensitivity to these parameters is rapidly lost at higher frequencies and is compromised by the ionosphere and antenna size at lower frequencies. Instruments for remote sensing from space in this spectral window are being developed by NASA (Aquarius) and ESA (SMOS) and are expected to be in orbit in a few years (2006). Although the band at 1.413 GHz is protected for passive use, RFI is a common problem. For example, the synthetic aperture radiometer, ESTAR (L-band, Horizontal polarization), has frequently experienced problems with RFI. During the Southern Great Plains Experiments (1997 and 1999), ESTAR experienced RFI significant enough to warrant changes in flight lines. The largest sources of RFI were identified as originating in airports and a likely source is air traffic control radar. In experiments in the vicinity of Richmond, VA, RFI in the form of periodic spikes was recorded, again suggestive of radar. However, in most cases the sources of the RFI are unknown. RFI is a sufficiently common problem that the first step in processing ESTAR data is a screening for RFI (a filter is used to detect large, rapid changes in brightness). Recently, measurements have been made with a new synthetic aperture radiometer, 2D-STAR. Examples of RFI observed simultaneously with ESTAR and the new synthetic aperture radiometer will be presented. 2D-STAR is an airborne instrument designed to develop the technology of aperture synthesis in two dimensions. It employs dual polarized patch antennas arranged in a cross configuration (+). Synthesis in two dimensions offers the potential for optimal thinning, but because of the wide field of view of the individual antennas it is potentially more susceptible to RFI. The 2D-STAR instrument was flown together with ESTAR in a series of test flights on the NASA P-3 aircraft near the Wallops Flight Facility during the summer of 2002. Both instruments experienced RFI over common locations. Examples will be presented and a comparison between instruments presented.

LeVine, David M.↗