Search NASA⌕ Search

SEARCH · Search NASA

Results for “interface reinforcement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Electroplated Polymer‐Modified Carbon Fiber for Performance‐Enhancing Composite Interfaces

Carbon fiber composite performance relies on the fiber-matrix interface for effective load transfer. To enhance interfacial properties between the fiber and matrix, often carbon fiber surfaces are oxidatively and covalently modified to incorporate chemical functional groups. By contrast, here, noncovalent electrodeposition of functional polyelectrolyte is applied onto conducting carbon fibers from aqueous solutions. A natural polymer, chitosan (CS), is electro-deposited onto the fiber surface, which undergoes multi-scale physical interactions. The bound CS layer with abundant amine functionalities reacts with epoxy moieties within the matrix to improve the interfacial properties. The scalable and energy-efficient electrodeposition eliminates traditional functionalization and sizing requirements of carbon fiber while delivering significantly higher mechanical performance with enhanced consistency. For continuous fiber reinforced composites, compared to conventional fibers, apparent interlaminar shear strength increases by 27%, reaching ≈86 MPa. The short fiber composites with only 2–11 wt.% fibers exhibit ≈20% increase in tensile strength with a peak performance of 120 MPa. Unlike traditionally treated and sized carbon fiber, this approach delivers coated fibers with long shelf-life and allows recovery of both CS in electrolyte form and carbon fiber by continuous electrochemical processing of the modified fibers with inverse polarity; thus, it promotes overall fiber recyclability.

36 MATERIALS SCIENCE↗

Heat Treatment Effects on the Tensile Properties and Microstructures of a SiC/RBSN Composite in Nitrogen

The room-temperature tensile properties and constituent microstructures of a unidirectionally reinforced SiC/reaction bonded silicon nitride (RBSN) composite have been investigated after heat treatments at 1400, 1600, or 1800 C in nitrogen for up to 100 hr. The composite consisted of approximately 24 vol% of aligned 140 micron diameter, continuous length, chemically vapor deposited SiC fibers in an approximately 40% porous silicon nitride matrix. The composites heat treated at 1400 C for up to 100 hr showed elastic modulus, first matrix cracking strength, and ultimate tensile strength values similar to those of the as-fabricated composites, but those heat treated for 1 hr beyond this temperature displayed losses in all three properties. Recrystallization of the SiC fibers, reaction between the carbon-rich interface coating on the fibers and the RBSN matrix, and dissociation of the RBSN matrix are the reasons for the loss of mechanical properties.

Bhatt, R. T.↗

Characterizing Facesheet/Core Disbonding in Honeycomb Core Sandwich Structure

Results are presented from an experimental investigation into facesheet core disbonding in carbon fiber reinforced plastic/Nomex honeycomb sandwich structures using a Single Cantilever Beam test. Specimens with three, six and twelve-ply facesheets were tested. Specimens with different honeycomb cores consisting of four different cell sizes were also tested, in addition to specimens with three different widths. Three different data reduction methods were employed for computing apparent fracture toughness values from the test data, namely an area method, a compliance calibration technique and a modified beam theory method. The compliance calibration and modified beam theory approaches yielded comparable apparent fracture toughness values, which were generally lower than those computed using the area method. Disbonding in the three-ply facesheet specimens took place at the facesheet/core interface and yielded the lowest apparent fracture toughness values. Disbonding in the six and twelve-ply facesheet specimens took place within the core, near to the facesheet/core interface. Specimen width was not found to have a significant effect on apparent fracture toughness. The amount of scatter in the apparent fracture toughness data was found to increase with honeycomb core cell size.

Rinker, Martin↗

Creep behavior of tungsten fiber reinforced niobium metal matrix composites

Tungsten fiber reinforced niobium metal matrix composites were evaluated for use in space nuclear power conversion systems. The composite panels were fabricated using the arc-spray monotape technique at the NASA Lewis Research Center. The creep behavior of W/Nb composite material was determined at 1400 and 1500 K in vacuum over a wide range of applied loads. The time to reach 1 percent strain, the time to rupture, and the minimum creep rate were measured. The W/Nb composites exceeded the properties of monolithic niobium alloys significantly even when compared on a strength to density basis. The effect of fiber orientation on the creep strength also was evaluated. Kirkendall void formation was observed at the fiber/matrix interface; the void distribution differed depending on the fiber orientation relative to the stress axis. A relationship was found between the fiber orientation and the creep strength.

Grobstein, T. L.↗

Approximating the stress field within the unit cell of a fabric reinforced composite using replacement elements

This report concerns the prediction of the elastic moduli and the internal stresses within the unit cell of a fabric reinforced composite. In the proposed analysis no restrictions or assumptions are necessary concerning yarn or tow cross-sectional shapes or paths through the unit cell but the unit cell itself must be a right hexagonal parallelepiped. All the unit cell dimensions are assumed to be small with respect to the thickness of the composite structure that it models. The finite element analysis of a unit cell is usually complicated by the mesh generation problems and the non-standard, adjacent-cell boundary conditions. This analysis avoids these problems through the use of preprogrammed boundary conditions and replacement materials (or elements). With replacement elements it is not necessary to match all the constitutional material interfaces with finite element boundaries. Simple brick-shaped elements can be used to model the unit cell structure. The analysis predicts the elastic constants and the average stresses within each constituent material of each brick element. The application and results of this analysis are demonstrated through several example problems which include a number of composite microstructures.

Foye, R. L.↗

Integrated TBC/EBC for SiC Fiber Reinforced SiC Matrix Composites for Next Generation Gas Turbines (Final Report)

In this ambitious project, a significant challenge preventing widespread use of ceramic matrix composites in hot section components of gas power generating turbines was addressed. Hot section components made from SiC fiber reinforced SiC matrix composites (SiC/SiC composites), have the potential to achieve a combined cycle energy efficiency of above 65%. To achieve this efficiency, the temperature of the combustion gases on the turbine component surface is expected to reach as high as ~1700ºC (3100ºF). However, SiC/SiC composites suffer from volatilization at high temperature under high velocity steam environment – typical in a turbine hot chamber. This integrated collaborative project, between two research groups at Clemson University and a team of engineers and scientists at GE Gas Power, focused on design, fabrication and evaluation of a new graded environmental barrier coating. Using the excellent compositional tailorability of polymer derived ceramics (PDCs), we developed an integrated EBC/BC that smoothly transitions from bottom SiC/SiC bond interface to hermetic sesquioxide (Y 2 O 3 ) top surface. This smooth compositional transition avoided the sharp CTE mismatch at interfaces to greatly reduce the thermal stress. The developed EBC is compatible with and bonds well with the bond coat that GE uses. The top hermetic oxide surface ensures low oxygen transportation and volatilization rates under the high velocity steam environment. The graded microstructure with increasing sesquioxide concentration also decreases the amount of Si and C elements near the top hermetic sesquioxide layer. Coatings made using a process suitable for manufacturing – atmospheric plasma spraying was demonstrated. The microstructure of coatings made using this process were fully characterized. Finally, the performance of these coatings was investigated under the most demanding conditions for this application. Specifically, high temperature, high velocity steam exposure; thermal shock test; and thermal cycling tests. The graded coatings performed exceptionally well in all these tests. Specific suggestions for future development in this area have also been identified. In addition to the excellent technical progress, this project helped initiate a robust collaboration between the research groups at Clemson and GE Gas Power. It also provided a high-quality learning and mentoring opportunity for the three post-doctoral research associates and two UG students at Clemson University who worked on this project. All proposed tasks, sub-tasks were completed, and all milestones achieved.

03 NATURAL GAS↗

The combined effect of temperature and seawater on the compression properties of carbon fiber vinyl ester composites for sandwich structures

For naval applications, composite sandwich structures are of significant interest, and are often manufactured using thin (2 to 4 mm) composite facings made from carbon or glass fiber reinforcement, attached to a thick (25 to 50 mm) section of PVC cellular foam or balsa wood-based core materials using a suitable polymeric resin. In the present study, we focus on the hygrothermal effect on the fiber-dominated compression properties of carbon fiber reinforced vinyl ester resin based polymeric composite (CF/VE), used as “skin” for a polymeric composite sandwich material. Hygrothermal conditioning is achieved by saturating samples in simulated seawater at 40°C. Compression properties are evaluated for coupons extracted along warp and fill undergoing- no conditioning, conditioning till saturation (up to 6 months), and long-term conditioning (2 years). Sea-water saturation yields in up to 12% drop in compression strength with a further 3–4% drop resulting from long-term conditioning. No statistically significant modulus degradation is noticed due to short or long-term hygrothermal exposure. The failure mechanism of the warp extracted coupon, which fails in a splitting failure mode originating due to the delamination between the 0/90 interface, or the fill extracted coupon, which fails due to the instability caused by tow micro-buckling, remains unchanged due to combined exposure (short or long-term) of seawater and temperature. The loss in strength is attributed to the degradation of the fiber-matrix interface, which is validated via conducting single fiber push-in tests with a nominal diameter of 7 micron for conditioned and unconditioned coupons.

Engineering↗

Hygrothermal aging and recycling effects on mechanical and thermal properties of recyclable thermoplastic glass fiber composites

Abstract Glass fiber‐reinforced polymer composites are widely used in marine applications, including renewable energy devices and submarines, due to their strength‐to‐weight ratios and corrosion resistance. As sustainability becomes more important, recyclable thermoplastic composites are gaining attention in marine energy applications. These materials face harsh conditions such as high chloride water, UV radiation, pressurization, and thermal cycling, which can affect their durability and recyclability. This study examines the impact of hygrothermal aging on the recyclability of an Elium glass fiber (GF) composite. Samples were mechanically ground for recycling, and mechanical and thermal properties were compared between aged and unaged samples. After seawater aging, the tensile strength and modulus of the unaged composite dropped by 25% and 13% respectively, due to water ingress along the fiber‐matrix interface. The recycled composite showed reduced flexural strength as the long fiber composite was converted into short fibers during the process. Differential scanning calorimetry (DSC) revealed no change in glass transition temperature after aging. Weight loss (25%) was attributed to the thermal stability of the glass fibers. Dynamic mechanical analysis (DMA) showed that the storage modulus increased with aging, and fracture analysis confirmed a mixed mode of failure for aged composites. Highlights Hygrothermal aging lowers mechanical performance of Elium® GF composites. Failure mechanism tends to be matrix cracking and interface bonding. Glass transition temperature is not reduced by hygrothermal aging. Fractured composite was successfully recycled via thermoforming. Flexural strength of the recycled composite is lower.

17 WIND ENERGY↗

Fatigue crack growth in a unidirectional SCS-6/Ti-15-3 composite

An investigation was conducted to characterize and model the fatigue crack growth (FCG) behavior of a SCS-6/Ti-15-3 metal matrix composite. Part of the study was conducted using a fatigue loading stage mounted inside a scanning electron microscope (SEM). This unique facility allowed high magnification viewing of the composite fatigue processes and measurement of the near crack tip displacements. The unidirectional composite was tested in the (0)8 (i.e., longitudinal) and (90)8 (i.e., transverse) orientations. For comparison purposes unreinforced matrix material produced by the identical process as the reinforced material was also tested. The results of the study reveal that the fatigue crack growth behavior of the composite is a function of specimen geometry, fiber orientation and the interaction of local stress fields with the highly anisotropic composite. In the case of (0)8 oriented single edge notch (SEN) specimens and (90)8 oriented compact tension (CT) specimens, the crack growth was normal to the loading direction. However, for the (0)8 CT specimens the crack grew mostly parallel to the loading and the fiber direction. The unusual fatigue behavior of the (0)8 CT specimens was attributed to the specimen geometry and the associated high tensile bending stresses perpendicular to the fiber direction. These stresses resulted in preferential cracking in the weak interface region perpendicular to the fiber direction. The interface region, and in particular the carbon coating surrounding the fiber proved to be the composites weakest link. In the (0)8 SEN the crack growth was confined to the matrix leaving behind unbroken fibers which bridged the cracked surfaces. As the crack grew longer, more fibers bridged the crack resulting in a progressive decrease in the crack growth rates and eventual crack arrest. The actual near crack tip displacement measurements were used in a proposed formulation for a bridging-corrected effective crack driving force, delta K(sub eff). This parameter was able to account for most of the experienced bridging and correlated the (0)8 SEN fatigue crack growth data reasonably well.

Kantzos, Peter↗

Effect of fiber reinforcements on thermo-oxidative stability and mechanical properties of polymer matrix composites

A number of studies have investigated the thermo-oxidative behavior of polymer matrix composites. Two significant observations have been made from these research efforts: (1) fiber reinforcement has a significant effect on composite thermal stability; and (2) geometric effects must be considered when evaluating thermal aging data. A compilation of some results from these studies is presented, and this information shows the influence of the reinforcement fibers on the oxidative degradation of various polymer matrix composites. The polyimide PMR-15 was the matrix material that was used in these studies. The control composite material was reinforced with Celion 6000 graphite fiber. T-40R graphite fibers, along with some very stable ceramic fibers were selected as reinforcing fibers because of their high thermal stability. The ceramic fibers were Nicalon (silicon carbide) and Nextel 312 (alumina-silica-boron oxide). The mechanical properties of the two graphite fiber composites were significantly different, probably owing to variations in interfacial bonding between the fibers and the polyimide matrix. The Celion 6000/PMR-15 bond is very tight but the T-40/PMR-15 bond is less tight. Three oxidation mechanisms were observed: (1) the preferential oxidation of the Celion 6000 fiber ends at cut surfaces, leaving a surface of matrix material with holes where the fiber ends were originally situated; (2) preferential oxidation of the composite matrix; and (3) interfacial degradation by oxidation. The latter two mechanisms were also observed on fiber end cut surfaces. The fiber and interface attacks appeared to initiate interfiber cracking along these surfaces.

Bowles, Kenneth J.↗

How Topological Polymer Loops on the Nanoparticle Surface Control the Mechanical Properties of Nanocomposites

Carbon black (CB) and silica (SiO 2 ) filled elastomers are known to be the most successful polymer nanocomposites (PNCs) in industry, where “bound rubber (BR)” (i.e., polymer chains that are physically or chemically adsorbed on the nanofiller surface) plays a critical role in their reinforcement. Here, we report a molecular-scale mechanism underlying the “BR-induced reinforcement” by integrating neutron scattering experiments and molecular dynamics simulations. Simplified non-cross-linked SiO 2 -filled polybutadiene (PB) and CB-filled PB reveal the critical role of topological polymer loops in the BR for the enhanced mechanical performance. The average loop size on the SiO 2 surface modified with a silane coupling agent is much smaller than that on the CB surface and the loops on the SiO 2 surface are densely formed, preventing interdigitation with the matrix chains. On the other hand, the larger, uncrowded loops formed on the CB surface facilitate the interdigitation with the matrix polymer chains even near the filler surface. In this way, a strong connectivity is established between a matrix and a nanofiller, resulting in an adhesive filler–polymer interface. Furthermore, our findings shed light on rich and complex physics and materials design problems in PNCs, where the topological polymer structure on the nanofiller surface directly controls the macroscopic mechanical properties.

36 MATERIALS SCIENCE↗

Residual strain gradient determination in metal matrix composites by synchrotron X-ray energy dispersive diffraction

An X-ray technique for the measurement of internal residual strain gradients near the continuous reinforcements of metal matrix composites has been investigated. The technique utilizes high intensity white X-ray radiation from a synchrotron radiation source to obtain energy spectra from small (0.001 cu mm) volumes deep within composite samples. The viability of the technique was tested using a model system with 800 micron Al203 fibers and a commercial purity titanium matrix. Good agreement was observed between the measured residual radial and hoop strain gradients and those estimated from a simple elastic concentric cylinders model. The technique was then used to assess the strains near (SCS-6) silicon carbide fibers in a Ti-14Al-21Nb matrix after consolidation processing. Reasonable agreement between measured and calculated strains was seen provided the probe volume was located 50 microns or more from the fiber/matrix interface.

Kuntz, Todd A.↗

Characterization of Temporal Changes of Interfacial Air Voids During Adhesive Curing and Bonding for Adhesively-Bonded Structures

This paper studied the evolution of air voids at the substrate-adhesive interface during the curing and bonding process of an epoxy-based adhesive between two glass substrates due to the sequence of adhesive placement, external pressure, and plasma treatment on substrates for bonding. The experimental results showed that a higher quantity of interfacial voids were generated during adhesive curing when the substrate was attached to the adhesive compared to when the adhesive was applied and distributed on the substrate. Such interfacial voids can be efficiently removed or reduced by applying slight pressure on the bonded structure during adhesive curing, or by leveraging plasma-treated substrates, as less reported in the literature. This work provided practical suggestions for preparing adhesive joints with minimized interfacial air voids to enhance bonding performance, particularly for dissimilar joints such as metal-CFRTP (carbon-fiber-reinforced thermoplastic polymer), as well as combinations with different types of polymer composites.

Qiao, Yao [BATTELLE (PACIFIC NW LAB)] (ORCID:00000↗

Adhesively-bonded Metal-CFRTP Bi-materials: Enhanced Crack Growth Resistance via Plasma and Quantified Fracture via Size Effect Method

This work investigated air plasma effect on the Mode I crack growth resistance of adhesively-bonded metal-CFRTP dissimilar joints by using aluminum alloy (AA6061) and short-carbon-fiber-reinforced polyamide 66 (CFRPA66) as an example, and the Double Cantilever Beam (DCB) fracture testing as an evaluation method. The results show that air plasma treatment can significantly improve the fracture resistance of adhesively-bonded AA6061-CFRPA66 dissimilar joints with about 140% enhanced Mode I fracture energy in maximum compared to non-treated ones. The quantified fracture energies from size effect method for both non-treated and plasma-treated cases are geometry-independent, whereas this is not true for modified beam theory causing geometry-dependent results. The foregoing improvement was confirmed from the failure surface morphology of plasma-treated specimens, showing fibers peeling off from CFRPA66 surface due to plasma-enhanced bonding between CFRPA66 and adhesive by the formation of covalent bonds at their interface. This study demonstrated air plasma as an efficient surface modification method to enhance the fracture resistance of adhesively-bonded metal-CFRTP dissimilar joints, and size effect method as a characterization method to properly quantify their fracture properties. These aspects are valuable in the area of multi-materials joining.

Plasma, Adhesive Bonding, Slow Crack Growth, fract↗

Galvanic Liquid Applied Coating System For Protection of Embedded Steel Surfaces from Corrosion

Corrosion of reinforcing steel in concrete is an insidious problem facing Kennedy Space Center (KSC), other Government Agencies, and the general public. These problems include KSC launch support structures, highway bridge infrastructure, and building structures such as condominium balconies. Due to these problems, the development of a Galvanic Liquid Applied Coating System would be a breakthrough technology having great commercial value for the following industries: Transportation, Infrastructure, Marine Infrastructure, Civil Engineering, and the Construction Industry. This sacrificial coating system consists of a paint matrix that may include metallic components, conducting agents, and moisture attractors. Similar systems have been used in the past with varying degrees of success. These systems have no proven history of effectiveness over the long term. In addition, these types of systems have had limited success overcoming the initial resistance between the concrete/coating interface. The coating developed at KSC incorporates methods proven to overcome the barriers that previous systems could not achieve. Successful development and continued optimization of this breakthrough system would produce great interest in NASA/KSC for corrosion engineering technology and problem solutions. Commercial patents on this technology would enhance KSC's ability to attract industry partners for similar corrosion control applications.

Curran, Joseph↗

A Modified Edge Crack Torsion Test for Measurement of Mode III Fracture Toughness of Laminated Tape Composites

Modifications to the edge crack torsion (ECT) test are studied to improve the reliability of this test for measuring the mode-III fracture toughness, G (sub IIIc), of laminated tape fiber-reinforced polymeric (FRP) composites. First, the data reduction methods currently used in the ECT test are evaluated and deficiencies in their accuracy are discussed. An alternative data reduction technique, which uses a polynomial form to represent ECT specimen compliance solution, is evaluated and compared to FEA (finite element analysis) results. Second, seven batches of ECT specimens are tested, each batch containing specimens with a preimplanted midplane edge delamination and midplane plies with orientations of plus theta divided by minus theta, with theta ranging from 0 degrees to 90 degrees in 15-degree increments. Tests on these specimens show that intralaminar cracking occurs in specimens from all batches except for which theta = 15 degrees and 30 degrees. Tests on specimens of these two batches are shown to result in mode-III delamination growth at the intended ply interface. The findings from this study are encouraging steps towards the use of the ECT test as a standardized method for measuring G (sub IIIc), although further modification to the data reduction method is required to make it suitable for use as part of a standardized test method.

Czabaj, Michael W.↗

Initial assessment of alternative carbon fiber geometries for design of cost-effective compressive performance: Size effect studies

Carbon fiber provides opportunity to reduce weight in structural composites, including wind turbine blades, due to the material's superior specific stiffness and specific strength compared to alternatives. Despite these advantages, cost and compressive performance are considered weaknesses for carbon fiber products available today. Studies to produce low-cost carbon fiber alternatives, including the use of textile-derived precursor systems, have shown progress and merit through the DOE/ORNL low-cost carbon fiber initiatives. Here, this work focuses on enabling increases in compressive strength through design of the carbon fiber geometry, applicable to both textile and conventional precursor systems, while also providing opportunities to reduce carbon fiber processing costs. Fiber-resin interface and fiber alignment are among the most frequently cited factors controlling composite compressive performance. However, it is believed that there is opportunity in traditionally unexplored routes to increasing compressive strength through alteration of the carbon fiber geometry by increasing the fiber area moment of inertia and/or the fiber perimeter and interfacial area. This paper presents initial results from manufacturing carbon fiber materials to assess the impacts of carbon fiber size on tested composite compressive performance with projected neutral or even beneficial impact on fiber and composite manufacturing economics. Carbon fiber systems with increasing size illustrate a favorable correlation for compressive performance greater than predicted from a micromechanical failure model. The manufacturing and mechanical test results support the hypothesis of this work that alterations to fiber geometry can be used to produce improvements of the compressive strength of carbon fiber reinforced polymers and provide incentive for related work in designing alternative shapes to further enhance compressive performance.

42 ENGINEERING↗

Thermal degradation of the tensile properties of undirectionally reinforced FP-AI203/EZ 33 magnesium composites

The effects of isothermal and cyclic exposure on the room temperature axial and transverse tensile strength and dynamic flexural modulus of 35 volume percent and 55 volume percent FP-Al2O3/EZ 33 magnesium composites were studied. The composite specimens were continuously heated in a sand bath maintained at 350 C for up to 150 hours or thermally cycled between 50 and 250 C or 50 and 350 C for up to 3000 cycles. Each thermal cycle lasted for a total of six minutes with a hold time of two minutes at the maximum temperature. Results indicate to significant loss in the room temperature axial tensile strength and dynamic flexural modulus of composites thermally cycled between 50 and 250 C or of composites isothermally heated at 350 C for up to 150 hours from the strength and modulus data for the untreated, as fabricated composites. In contrast, thermal cycling between 50 and 350 C caused considerable loss in both room temperature strength and modulus. Fractographic analysis and measurement of composite transverse strength and matrix hardness of thermally cycled and isothermally heated composites indicated matrix softening and fiber/matrix debonding due to void growth at the interface and matrix cracking as the likely causes of the strength and modulus loss behavior.

Bhatt, R. T.↗