Search NASA⌕ Search

SEARCH · Search NASA

Results for “life estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Development of a health monitoring framework: Application to a supercritical pulverized coal-fired boiler

In this study, this work details the development of a physics-based equipment health monitoring framework for a supercritical boiler, using first-principles models to estimate the remaining useful life (RUL) of its components. The framework accounts for fatigue and creep life consumption, generating spatio-temporal variations in mechanical and thermal stress. Analysis of the stress profile throughout the boiler highlights the finishing superheater inlet steam header as a vulnerable location susceptible to damage from cycling operation. The framework also yields quantified uncertainty in the RUL projection for specific locations, accounting for uncertainties in material properties and boiler operation. Results indicate that operational uncertainties (e.g., seasonal variation and operational strategy) and material properties (e.g., rupture time coefficients, Young’s modulus, yield strength, and coefficient of thermal expansion) significantly impact the RUL of the finishing superheater inlet steam header. Additionally, case studies demonstrate the use of the health monitoring framework as a predictive tool for operational planning under uncertainty, including scenarios with and without updates on the operation of the boiler.

20 FOSSIL-FUELED POWER PLANTS↗

Co-optimization of nuclear reactor flexible power operation and maintenance scheduling

As flexible power operation of nuclear power plants becomes more attractive due to the reduction in fossil-fueled dispatchable generation on energy grids, finding optimal power production strategies that balance revenue generation with operational concerns becomes more complex. This article presents a general framework to aid operators in designing economically optimal long term dispatch strategies for nuclear power plants. The principal novelty is the linking of estimated system remaining useable life (RUL) to strategic operational decisions. It is shown that, depending on the relationship between the fixed costs from maintenance and the associated lost revenue from an outage, it can be economically optimal in the long term to delay a maintenance outage and not perform this alongside refueling. For a given relationship between power ramping and degradation, optimal strategies were found that discouraged load following in some situations while minimizing unnecessary maintenance. It is shown that heavy load following can cause maintenance and refueling outages to diverge due to their inverse relationships with respect to load following, potentially leading to a significant loss in capacity factor. As a result, this general framework can be applied to specific reactor dispatch allowing operators to adapt operational strategies as future grid conditions change.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sustainable Aviation Fuel from High-Strength Wastewater via Membrane-Assisted Volatile Fatty Acid Production: Experimental Evaluation, Techno-economic, and Life-Cycle Analyses

To reduce emissions from combustion of fossil fuels, sustainable aviation fuels (SAFs) have the potential to decarbonize the aviation sector. Redirecting wastes from conventional waste management practices and using them as cost-effective feedstocks for low-carbon fuels can reduce emissions from both waste disposal and fuel combustion. One approach is to upgrade wet wastes to SAF precursors, such as volatile fatty acids (VFAs). Here, in this study, novel membrane-assisted arrested methanogenesis was developed to convert high-strength wastewater to VFAs. Based on experimental results of VFA production, techno-economic and life-cycle analyses were conducted to estimate the potential economic and environmental benefits of SAF production from high-strength wastewater via VFAs. By evaluating three proposed scenarios for VFA production, a minimum production cost of VFA is achieved at $\$$0.60/kg VFA at a wastewater flow rate of 1100 MT/d. For the corresponding VFA-derived SAF, the estimated minimum fuel selling price is $\$$4.64/gasoline gallon equivalent. The life-cycle analysis shows that up to a 71% reduction in greenhouse gas emissions can be achieved relative to its fossil-counterpart along with lower water and fossil-fuel consumption.

09 BIOMASS FUELS↗

Impact of recent updates to neutrino oscillation parameters on the effective Majorana neutrino mass in 0 ν β β decay

We investigate how recent updates to neutrino oscillation parameters and the sum of neutrino masses influence the sensitivity of neutrinoless double-beta ( 0 ν β β ) decay experiments. Incorporating the latest cosmological constraints on the sum of neutrino masses and laboratory measurements on oscillations, we determine the sum of neutrino masses for both the normal hierarchy (NH) and the inverted hierarchy (IH). Our analysis reveals a narrow range for the sum of neutrino masses, approximately 0.06 eV / c 2 for NH and 0.102 eV / c 2 for IH. Utilizing these constraints, we calculate the effective Majorana masses for both NH and IH scenarios, establishing the corresponding allowed regions. Importantly, we find that the minimum neutrino mass is nonzero, as constrained by the current oscillation parameters. Additionally, we estimate the half-life of 0 ν β β decay using these effective Majorana masses for both NH and IH. Our results suggest that upcoming ton-scale experiments will comprehensively explore the IH scenario, while 100-ton-scale experiments will effectively probe the parameter space for the NH scenario, provided the background index can achieve 1 event/kton-year in the region of interest. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

A Design for Remanufacturing Framework Incorporating Identification, Evaluation, and Validation: A Case Study of Hydraulic Manifold

In recent years, academic researchers and engineers in the industry have widely recognized the necessity of integrating remanufacturing considerations into product design iterations to advance sustainability objectives. Acknowledging the importance of design for remanufacturing (DfRem), efforts were made to develop tools and guidelines that could be implemented in practice. However, such methods largely rely upon experiential insights and qualitative assessments, leaving a gap in the ability to quantitatively assess the economic and environmental impacts of design choices. To bridge this gap, we investigate existing efforts and present a framework for DfRem that integrates established design and remanufacturing practices into a cohesive workflow with quantitative assessments. To demonstrate its efficacy for making practical design changes for remanufacturing, we apply the framework to a hydraulic manifold in a transmission system for heavy-duty tractors. Through this industry-relevant case study, we focus on showcasing the practical utility of our framework. Based on the identified design modifications from remanufacturability analysis, we estimate the reductions in life cycle costs, energy consumption, and emissions. Afterward, the modifications are tested using physical experiments with plans for integration into future iterations of the hydraulic manifold design and production. Here, we anticipate this framework can illustrate the process of remanufacturing that ensures improvements in sustainability while maintaining performance and reliability standards.

design for X↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 (Vol.1)

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing a valid approach for establishing cartridge change schedules.2 Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches such as manufacturer recommendations and modeling are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, and June 23-24, 2017, using headspace vapors from Hanford tank SX-104 and Hanford tank SX-101, respectively. Headspace vapors under static conditions were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and subsequently were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 Volume 1

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in powered air-purifying respirators (PAPR) to determine the period of time that the cartridges would provide adequate performance for PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, from headspace vapors from Hanford tank SX-101 and from June 23-24, 2017, from Hanford tank SX-104. Headspace vapors were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota) were assessed on separate days. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AW Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AW tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service-life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 23-25, 2016, on a slipstream from the AW exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

54 ENVIRONMENTAL SCIENCES↗

Environmentally Assisted Fatigue in Light Water Reactor Environment

This report summarizes the Environmentally Assisted Fatigue (EAF) research conducted at ANL under the US DOE Light Water Reactor Sustainability (LWRS) program. Starting from a rich background in theoretical and experimental EAF, ANL previously developed an approach to evaluate fatigue performance of reactor materials in light water reactor environments with the correction factor F en . The approach was based on a large body of experimental work performed at ANL and elsewhere, and was consistent with American Society of Mechanical Engineers (ASME)’s methodology governing the design and construction of reactor components. In recent years, the program was focused on component fatigue prediction and made several major and fundamental contributions in this area. These accomplishments help meet the needs identified by the industry concerning component level fatigue predictions in complex, transient conditions. The main contribution of the ANL program involved the development of a system-level model for estimating residual strain and life of nuclear reactor coolant system components under connected-system-thermal-mechanical boundary conditions. The goal was to predict the stress hotspots, strain residuals, strain amplitudes and the resulting fatigue lives. Thermal-mechanical stress analysis was performed considering thermal stratification and a design-basis reactor loading cycle. Based on the finite element (FE) model results, the strain residuals, strain amplitudes and resulting fatigue lives of reactor coolant system (RCS) components were predicted. The results show that some of the RCS components can have significantly different strain amplitudes, residual strain, and fatigue lives, despite having similar geometry and material. In addition, the simulated component-level strain profile can guide the selection of appropriate test inputs for conducting laboratory-scale EAF tests. Building upon the system-level model, ANL developed a digital twin (DT) framework to predict the structural states and associated fatigue life of components in real-time. This framework is a comprehensive system designed to predict the structural states and fatigue lives of reactor components. It includes multiple models and integrates artificial intelligence (AI), machine learning (ML), and FE based modeling tools to evaluate the structural states and fatigue lives.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Scatter factor and reliability of aircraft structures

The concept of time to first failure is utilized to perform a parameter study of scatter factors of aircraft structures. The Weibull distribution is used for estimation of characteristic and certifiable lives. Scatter factors for various Weibull-shaped parameters, fleet sizes and level of reliabilities are calculated. It is concluded that the currently used range of scatter factors (2 through 4) is too narrow for the estimation of a safe life and that a safe and economical design for structural materials with shape parameters less than 2 does not seem feasible except for very small fleet sizes and low levels of reliability.

Schueller, G. I.↗

Cost analysis of water recovery systems

Cost and performance data from Gemini, Skylab, and other aerospace and biotechnology programs were analyzed to identify major cost elements required to establish cost estimating relationships for advanced life support subsystems for long range planning in support of earth orbital programs. Cost analysis are presented for five leading water reclamation systems; (1) RITE waste management-water system;(2) reverse osmosis system;(3) multifiltration system;(4) vapor compression system; and(5) closed air evaporation system with electrolytic pretreatment.

Yakut, M. M.↗

Cost analysis of oxygen recovery systems

Report is made of the cost analysis of four leading oxygen recovery subsystems which include two carbon dioxide reduction subsystems and two water electrolysis subsystems, namely, the solid polymer electrolyte and the circulating KOH electrolyte. The four oxygen recovery systems were quantitatively evaluated. System characteristics, including process flows, performance, and physical characteristics were also analyzed. Additionally, the status of development of each of the systems considered and the required advance technology efforts required to bring conceptual and/or pre-prototype hardware to an operational prototype status were defined. Intimate knowledge of the operations, development status, and capabilities of the systems to meet space mission requirements were found to be essential in establishing the cost estimating relationships for advanced life support systems.

Yakut, M. M.↗

Automatic interpretation of ERTS data for forest management

Automatic stratification of forested land from ERTS-1 data provides a valuable tool for resource management. The results are useful for wood product yield estimates, recreation and wild life management, forest inventory and forest condition monitoring. Automatic procedures based on both multi-spectral and spatial features are evaluated. With five classes, training and testing on the same samples, classification accuracy of 74% was achieved using the MSS multispectral features. When adding texture computed from 8 x 8 arrays, classification accuracy of 99% was obtained.

Kirvida, L.↗

SPS Energy Conversion Power Management Workshop

Energy technology concerning photovoltaic conversion, solar thermal conversion systems, and electrical power distribution processing is discussed. The manufacturing processes involving solar cells and solar array production are summarized. Resource issues concerning gallium arsenides and silicon alternatives are reported. Collector structures for solar construction are described and estimates in their service life, failure rates, and capabilities are presented. Theories of advanced thermal power cycles are summarized. Power distribution system configurations and processing components are presented.

Source record↗

Accommodations assessment: Spaceborne Doppler lidar wind measuring system

An accommodations analysis performed by the MSFC Preliminary Design Office for a spaceborne Doppler lidar wind measuring system is summarized. A dedicated, free-flying spacecraft design concept is described. Mass and beginning-of-life power requirements are estimated at 2260 kg and 6.0 - 8.5 kW respectively, to support a pulsed, CO2, Doppler lidar having a pulse energy of 10 J, pulse rate of 8 Hz, and efficiency of approximately 5%. Under the assumptions of the analysis, such a system would provide wind measurements on a global scale, with accuracies of a few meters per second.

Source record↗