Search NASA⌕ Search

SEARCH · Search NASA

Results for “moving object detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Colloid-Facilitated Actinide Transport in a Cementitious-Impacted SRS Groundwater

The objective of this report is to provide a literature review relevant to the question of whether colloid facilitated transport of plutonium is enhanced in a cementitious groundwater system on the Savannah River Site (SRS). Contaminant transport is commonly described as taking place in a system with a mobile aqueous phase and an immobile solid phase. There has been an increasing awareness of a third phase, a mobile solid phase, also referred to as a mobile colloidal phase. Mobile colloids consist of organic and/or inorganic submicron-particles that move with groundwater flow. When radionuclides are associated with the mobile colloids, the net effect is that radionuclides can move faster through the subsurface system than would be predicted by transport models that do not include mobile colloids. It is important to distinguish between subsurface colloids and subsurface mobile colloids. The subsurface environment includes an enormous reservoir of colloids, but only a tiny fraction, if any, are mobile. Mobile colloid formation is commonly described as involving a three-step process: genesis, stabilization, and transport. It was concluded that there is a strong likelihood that submicron colloids of plutonium exist near the source term, (i.e., the genesis step is likely completed). While such particles have not been directly detected, it is highly likely that plutonium could either attach to submicron particles in the sediment or that submicron plutonium fragments exist at the source. However, the tendency for these plutonium colloids to move in the SRS subsurface is extremely low, especially in engineered cementitious environments where the ionic strength of the solution and the elevated concentrations of divalent cations greatly curtails colloid suspension stability (i.e., the stabilization step is likely not completed). Together these data strongly indicate that plutonium-bearing colloids would likely exist in the near field of a tank closure facility, but the colloids would be unlikely to be mobile, thereby providing a vector for enhanced transport. Under cementitious leachate impacted groundwater conditions, it is reasonable to assume plutonium transport occurs primarily as a two-phase system, a mobile aqueous phase and an immobile solid phase.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The influence of respiratory motion on CT image volume definition

Purpose: Radiotherapy treatments are based on geometric and density information acquired from patient CT scans. It is well established that breathing motion during scan acquisition induces motion artifacts in CT images, which can alter the size, shape, and density of a patient's anatomy. The aim of this work is to examine and evaluate the impact of breathing motion on multislice CT imaging with respiratory synchronization (4DCT) and without it (3DCT). Methods: A specific phantom with a movable insert was used. Static and dynamic phantom acquisitions were obtained with a multislice CT. Four sinusoidal breath patterns were simulated to move known geometric structures longitudinally. Respiratory synchronized acquisitions (4DCT) were performed to generate images during inhale, intermediate, and exhale phases using prospective and retrospective techniques. Static phantom data were acquired in helical and sequential mode to define a baseline for each type of respiratory 4DCT technique. Taking into account the fact that respiratory 4DCT is not always available, 3DCT helical image studies were also acquired for several CT rotation periods. To study breath and acquisition coupling when respiratory 4DCT was not performed, the beginning of the CT image acquisition was matched with inhale, intermediate, or exhale respiratory phases, for each breath pattern. Other coupling scenarios were evaluated by simulating different phantom and CT acquisition parameters. Motion induced variations in shape and density were quantified by automatic threshold volume generation and Dice similarity coefficient calculation. The structure mass center positions were also determined to make a comparison with their theoretical expected position. Results: 4DCT acquisitions provided volume and position accuracies within ±3% and ±2 mm for structure dimensions >2 cm, breath amplitude ≤15 mm, and breath period ≥3 s. The smallest object (1 cm diameter) exceeded 5% volume variation for the breath patterns of higher frequency and amplitude motion. Larger volume differences (>10%) and inconsistencies between the relative positions of objects were detected in image studies acquired without respiratory control. Increasing the 3DCT rotation period caused a higher distortion in structures without obtaining their envelope. Simulated data showed that the slice acquisition time should be at least twice the breath period to average object movement. Conclusions: Respiratory 4DCT images provide accurate volume and position of organs affected by breath motion detecting higher volume discrepancies as amplitude length or breath frequency are increased. For 3DCT acquisitions, a CT should be considered slow enough to include lesion envelope as long as the slice acquisition time exceeds twice the breathing period. If this requirement cannot be satisfied, a fast CT (along with breath-hold inhale and exhale CTs to estimate roughly the ITV) is recommended in order to minimize structure distortion. Even with an awareness of a patient's respiratory cycle, its coupling with 3DCT acquisition cannot be predicted since patient anatomy is not accurately known.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensitive Detection: Photoacoustics, Thermography, and Optical Radiation Pressure

Research during the granting period has been carried out in several areas concerned with sensitive detection. An infrared pyrometer based on the photoacoustic effect has been developed. The sensitivity of this instrument to temperature differentials has been shown to be 50 mK. An investigation of transients that accompany photoacoustic waves generated by pulsed lasers has been carried out. Experiments have shown the existence of the transients, and a theory based on rapid heat diffusion has been developed. The photoacoustic effect in one dimension is known to increase without bound (in the linear acoustics regime) when an optical beam moves in a fluid at the sound speed. A solution to the wave equation for pressure has been found that describes the photoacoustic effect in a cell where an infrared optical grating moves at the sound speed. It was shown that the amplification effect exists along with a cavity resonance that can be used to great advantage in trace gas detection. The theory of the photoacoustic effect in a structure where the acoustic properties periodically vary in a one-dimensional based has been formulated based on solutions to a Mathieu equation. It was found that it is possible to excite photoacoustic waves within the band gaps to produce large amplitude acoustic waves. The idea of self-oscillation in a photoacoustic cell using a continuous laser has been investigated. A theory has been completed showing that in a compressive wave, the absorption increases as a result of the density increase leading to further absorption and hence an increased amplitude photoacoustic effect with the result that in a resonator, self-oscillation can place. Experiments have been carried out where irradiation of a suspension of absorbing carbon particles with a high power laser has been shown to result in cavitation luminescence. That is, following generation of CO and H 2 from the carbon particles through the carbon-steam reaction, an expanding gas bubble is produced, which during the phase where the bubble collapses, a sonoluminescent flash is produced. Work on the voltage generated by a spherical, colloidal object irradiated with an acoustic wave has been determined. The theory of X-ray imaging using a grating to generate a spatially heterodyned image has been formulated. The properties of X-ray images taken with a grating placed before the object and the resulting image Fourier transformed and filtered has been determined. The method essentially heterodynes the spatial component of the object in the image which can be used to eliminate scatter that degrades contrast. Another area of investigation is the motion of the components in a separation method known as thermal diffusion, or the Soret effect. By exploring the mathematics of the effect, it was found that the underlying mechanism of the separation is propagation of a shock whose features are masked typically by the effects of viscosity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 3 Gyr White Dwarf with Warm Dust Discovered via the Backyard Worlds: Planet 9 Citizen Science Project

Infrared excesses due to dusty disks have been observed orbiting white dwarfs with effective temperatures between 7200 and 25,000 K, suggesting that the rate of tidal disruption of minor bodies massive enough to create a coherent disk declines sharply beyond 1 Gyr after white dwarf formation. We report the discovery that the candidate white dwarf LSPM J0207+3331, via the Backyard Worlds: Planet 9 citizen science project and Keck Observatory follow-up spectroscopy, is hydrogen dominated with a luminous compact disk (L IR/L star = 14%) and an effective temperature nearly 1000 K cooler than any known white dwarf with an infrared excess. The discovery of this object places the latest time for large-scale tidal disruption events to occur at ~3 Gyr past the formation of the host white dwarf, making new demands of dynamical models for planetesimal perturbation and disruption around post-main-sequence planetary systems. Curiously, the mid-infrared photometry of the disk cannot be fully explained by a geometrically thin, optically thick dust disk as seen for other dusty white dwarfs, but requires a second ring of dust near the white dwarf's Roche radius. In the process of confirming this discovery, we found that careful measurements of WISE source positions can reveal when infrared excesses for white dwarfs are co-moving with their hosts, helping distinguish them from confusion noise.

Debes, John H.↗

Corrective Action Decision Document/Closure Report for Corrective Action Unit 374: Area 20 Schooner Unit Crater, Nevada National Security Site, Nevada with ROTC 1 and 2, Revision 0 with ROTCs 1,2, and 3

Corrective Action Unit 374 comprises five corrective action sites (CASs): • 18-22-05, Drum • 18-22-06, Drums (20) • 18-22-08, Drum • 18-23-01, Danny Boy Contamination Area • 20-45-03, U-20u Crater (Schooner) The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation that no further corrective action is needed for CAU 374 based on the implementation of corrective actions. The corrective action of closure in place with administrative controls was implemented at CASs 18-23-01 and 20-45-03, and a corrective action of removing potential source material (PSM) was conducted at CAS 20-45-03. The other CASs require no further action; however, best management practices of removing PSM and drums at CAS 18-22-06, and removing drums at CAS 18-22-08 were performed. Corrective action investigation (CAI) activities were performed from May 4 through October 6, 2010, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 374: Area 20 Schooner Unit Crater, Nevada Test Site, Nevada. The approach for the CAI was divided into two facets: investigating the primary release of radionuclides and investigating other releases (migration in washes and chemical releases). The purpose of the CAI was to fulfill data needs as defined during the data quality objective (DQO) process. The CAU 374 dataset of investigation results was evaluated based on the data quality indicator parameters. This evaluation demonstrated the dataset is acceptable for use in fulfilling the DQO data needs. Analytes detected during the CAI were evaluated against final action levels (FALs) established in this document. Radiological doses exceeding the FAL of 25 millirem per year were found to be present in the surface soil that was sampled. It is assumed that radionuclide levels present in subsurface media within the craters and ejecta fields (default contamination boundaries) at the Danny Boy and Schooner sites exceed the FAL. It is also assumed that PSM in the form of lead-acid batteries at Schooner exceeds the FAL. Therefore, corrective actions were undertaken that consist of removing PSM, where present, and implementing a use restriction and posting warning signs at the Danny Boy and Schooner sites. These use restrictions were recorded in the FFACO database; the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Facility Information Management System; and the NNSA/NSO CAU/CAS files. Therefore, NNSA/NSO provides the following recommendations: • No further corrective actions are necessary for CAU 374. • A Notice of Completion to NNSA/NSO is requested from the Nevada Division of Environmental Protection for closure of CAU 374. • Corrective Action Unit 374 should be moved from Appendix III to Appendix IV of the FFACO.

54 ENVIRONMENTAL SCIENCES↗

Grism Performance for Mid-IR (5-40 microns) Spectroscopy

Grisms provide a straightforward method to transform an imager into a spectrometer with little change to the original imaging optics. This paper addresses the performance of a suite of grisms as part of an Astrobiology Science and Instrument Development (ASTID) Program to implement a moderate resolution spectroscopic capability to the mid/far-IR facility instrument FORCAST for the Stratospheric Observatory For Infrared Astronomy (SOFIA) [see accompanying abstract by Adams et al.]. A moderate resolution mid-IR spectrometer on SOFIA will offer advantages not available to either ground or space-based instruments after the Spitzer Space Telescope ceases operation in approx. 2007. SOFIA will begin operations in 2007 and will have an operational lifetime of approx. 20 years. From aircraft altitudes, it will be possible to cover a range of wavelengths, particularly in the critical 5-9 micron band, where detection of astrobiologically interesting molecules have key spectral signatures, that are not accessible from the ground. This grism suite consists of six grisms: four monolithic Si grisms [see accompanying abstract by Mar et al.] and two KRS-5 grisms. These devices will allow long slit low-resolution and short slit, cross-dispersed high-resolution spectroscopic modes selectable by simply moving the camera filter wheels. This configuration will enable observing programs to gather images and spectra in a single SOFIA flight. The four silicon grisms, whose performance is highlighted in this paper, will operate in the following wavelength ranges: 5-8, 17-28, and 28-37 microns. In the 5-8 micron range, R=1200 is achievable for a 2 arcsecond slit using the grism as a cross-disperser. For the 17-28 and 28-37 micron ranges, the resolving powers are R approx. 130, 250 when used in low orders with a slit of 3 arcseconds. The silicon grisms demonstrate a new family of dispersive elements with good optical performance for spectroscopy from 1.2-8 micron and beyond 18 microns. Furthermore, the FORCAST grism modes are close in wavelength coverage and resolving power to the Spitzer Infrared Spectrograph (IRS), so that among other possible observations, SOFIA can now enable follow-up studies of the brighter objects that Spitzer has observed and enable studies of sources that were too bright for observation with Spitzer.

Ennico, K. A.↗

The fastest unbound stars in the universe

The discovery of hypervelocity stars (HVSs) leaving our galaxy with speeds of nearly 10{sup 3} km s{sup −1} has provided strong evidence of the existence of a massive compact object at the galaxy’s center. HVSs ejected via the disruption of stellar binaries can occasionally yield a star with v{sub ∞} ≲ 10{sup 4} km s{sup −1}; here we show that this mechanism can be extended to massive black hole (MBH) mergers, where the secondary star is replaced by a MBH with mass M{sub 2}≳10{sup 5}M{sub ⊙}. We find that stars that are originally bound to the secondary MBH are frequently ejected with v{sub ∞}>10{sup 4} km s{sup −1}, and occasionally with velocities ∼10{sup 5} km s{sup −1} (one third the speed of light). For this reason we refer to stars ejected from these systems as “semi-relativistic” hypervelocity stars (SHSs). Bound to no galaxy, the velocities of these stars are so great that they can cross a significant fraction of the observable universe in the time since their ejection (several Gpc). We demonstrate that if a significant fraction of MBH mergers undergoes a phase in which their orbital eccentricity is ≳0.5 and their periapse distance is tens of the primary’s Schwarzschild radius, the space density of fast-moving (v{sub ∞}>10{sup 4} km s{sup −1}) SHSs may be as large as 10{sup 3} Mpc{sup −3}. Hundreds of SHSs will be giant stars that can be detected by future all-sky infrared surveys such as WFIRST or Euclid and proper motion surveys such as LSST, with spectroscopic follow-up being possible with the James Webb Space Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvements in Speed and Functionality of a 670-GHz Imaging Radar

Significant improvements have been made in the instrument originally described in a prior NASA Tech Briefs article: Improved Speed and Functionality of a 580-GHz Imaging Radar (NPO-45156), Vol. 34, No. 7 (July 2010), p. 51. First, the wideband YIG oscillator has been replaced with a JPL-designed and built phase-locked, low-noise chirp source. Second, further refinements to the data acquisition and signal processing software have been performed by moving critical code sections to C code, and compiling those sections to Windows DLLs, which are then invoked from the main LabVIEW executive. This system is an active, single-pixel scanned imager operating at 670 GHz. The actual chirp signals for the RF and LO chains were generated by a pair of MITEQ 2.5 3.3 GHz chirp sources. Agilent benchtop synthesizers operating at fixed frequencies around 13 GHz were then used to up-convert the chirp sources to 15.5 16.3 GHz. The resulting signals were then multiplied 36 times by a combination of off-the-shelf millimeter- wave components, and JPL-built 200- GHz doublers and 300- and 600-GHz triplers. The power required to drive the submillimeter-wave multipliers was provided by JPL-built W-band amplifiers. The receive and transmit signal paths were combined using a thin, high-resistivity silicon wafer as a beam splitter. While the results at present are encouraging, the system still lacks sufficient speed to be usable for practical applications in a contraband detection. Ideally, an image acquisition speed of ten seconds, or a factor of 30 improvement, is desired. However, the system improvements to date have resulted in a factor of five increase in signal acquisition speed, as well as enhanced signal processing algorithms, permitting clearer imaging of contraband objects hidden underneath clothing. In particular, advances in three distinct areas have enabled these performance enhancements: base source phase noise reduction, chirp rate, and signal processing. Additionally, a second pixel was added, automatically reducing the imaging time by a factor of two. Although adding a second pixel to the system doubles the amount of submillimeter components required, some savings in microwave hardware can be realized by using a common low-noise source.

Dengler, Robert J.↗

Renewable Firming EnergyFarm Final Report

The American Recovery and Reinvestment Act (ARRA) of 2009 (Recovery Act) provided the U.S. Department of Energy (DOE) with funds to modernize the electric power grid. One program under this initiative is the Smart Grid Demonstration program (SGDP). The SGDP mandate is to demonstrate how a suite of existing and emerging smart grid technologies can be innovatively applied and integrated to prove technical, operational, and business-model feasibility. Primus Power is a provider of low cost, long life and long duration energy storage systems. The Company’s flow batteries are shipping to US and international microgrid, utility, military, commercial and industrial customers. Primus Power’s EnergyPod® is a modular battery system for grid scale applications available in configurations ranging from 25 kW to more than 25 MW. The EnergyPod provides nameplate power for 5 hours. This long duration unlocks economic benefits on both sides of the electric meter. It allows commercial and industrial customers to shift low cost electricity purchased at night to offset afternoon electrical peaks to reduce utility demand charges. It also allows utilities to economically reduce power peaks and defer costly upgrades to distribution infrastructure. An EnergyPod contains one or more EnergyCells-a highly engineered flow battery core made from low cost, readily available materials. An EnergyCell includes a membrane-free stack of titanium electrodes located above a novel liquid electrolyte management system. This patented design enables reliable, low maintenance operation for decades. It is safe and robust, featuring non-flammable aqueous electrolyte, sophisticated fault detection and built-in secondary containment. Unlike Li Ion batteries, the EnergyCell is not susceptible to thermal runaway. This cooperative agreement project was started in Feb 2010. The objectives of the project are: 1. Trigger rapid adoption of grid storage systems in the US by demonstrating a low cost, robust and flexible EnergyFarm®. 2. Accelerate adoption of renewable energy and enhance grid stability by firming the output of wind & solar farms. 3. Demonstrate improved grid asset utilization by storing energy during off-peak periods for dispatch during local load peaks. 4. Establish an advanced battery manufacturing industry in the U.S. 5. Reduce CO2 emissions from utilities. This report summarizes the key milestones, data, results and lessons learned from the project. The desired goals and benefits of the cooperative agreement with the DOE have all been achieved. The project has contributed to reducing power costs, accelerating adoption of renewable energy resources, reducing greenhouse gas emissions and establishing advanced battery manufacturing in the U.S. The Recovery Act funds provided thru the DOE have been leveraged multiple times by additional private equity investment. Primus Power continues to ship low cost, long life and long duration EnergyPod® flow battery systems to utilities, commercial/industrial, microgrid and data center customers. After the conclusion of this project, Primus Power has modified the EnergyPod® design to optimize around energy performance. Primus Power has moved to a prefabricated enclosure instead of multiple EnergyCells in a container. This lowers capital and maintenance costs and can optimize site design. Utilities are starting to adopt energy storage for a variety of functions. The market will grow as the technology is proven and profitable applications expand.

25 ENERGY STORAGE↗

New Research by CCD Scanning for Comets and Asteroids

Spacewatch was begun in 1980; its purpose is to explore the various populations of small objects within the solar system. Spacewatch provides data for studies of comets and asteroids, finds potential targets for space missions, and provides information on the environmental problem of possible impacts. Moving objects are discovered by scanning the sky with charge-coupled devices (CCDS) on the 0.9-meter Spacewatch Telescope of the University of Arizona on Kitt Peak. Each Spacewatch scan consists of three drift scan passes over an area of sky using a CCD filtered to a bandpass of 0.5-1.0 pm (approximately V+R+I with peak sensitivity at 0.7 pm). The effective exposure time for each pass is 143 seconds multiplied by the secant of the declination. The area covered by each scan is 32 arcminutes in declination by about 28 minutes of time in right ascension. The image scale is 1.05 arcseconds per pixel. Three passes take about 1.5 hours to complete and show motions of individual objects over a one hour time baseline. The limiting magnitude is about 21.5 in single scans. CCD scanning was developed by Spacewatch in the early 1980s, with improvements still being made - particularly by bringing a new 1.8-m Spacewatch Telescope on line. In the meantime, we have been finding some 30,000 new asteroids per year and applying their statistics to the study of the collisional history of the solar system. Spacewatch had found a total of 150 Near-Earth Asteroids (NEAS) and 8 new comets, and had recovered one lost comet (P/Spitaler in 1993). Spacewatch is also efficient in recovery of known comets and has detected and reported positions for more than 137,000 asteroids, mostly new ones in the main belt, including more than 10,882 asteroids designated by the Minor Planet Center (MPC).

Gehrels, Tom↗

Oculometric Analysis of Saccadic Compensation for Visual Motion Processing Impairment due to Alcohol and Sleep Disruption

The Visuomotor Control Laboratory at Ames Research Center has developed a 5-minute ocular tracking test that computes 21 largely independent metrics of visuomotor performance, reflecting neural signal processing along a number of distinct pathways through cortex, brainstem, and cerebellum. Human sensorimotor performance is resilient to the challenges and stressors of many operational environments, in part, because overall performance is achieved through multiple parallel systems. Our multidimensional oculometrics allow us to examine impacts on these sub-components separately. To illustrate this, we contrasted the effects of two mild neural stressors, acute sleep-deprivation and low-dose alcohol. We have previously shown that, in both cases, oculometric analysis is a highly sensitive indicator of impairment. Here we quantified not only the observed impact on the performance of one sub-system, smooth pursuit, which uses high-level cortical processing of visual motion to track a moving object, but also the observed (partial) compensation by an evolutionarily older mid-brain and brainstem subsystem, saccades, which generates jumps in eye position to catch up with the target when smooth pursuit is inadequate. Specifically, we examined the dose-response (effect size vs. dose size) of the ground lost (pursuit deficit) and the ground recouped (saccadic compensation) across three separate studies – acute low-dose alcohol administration (16 subjects), acute sleep loss (12 subjects), and acute sleep loss with caffeine intervention (9 subjects). We computed the dose-response slopes using linear regression. The figure below shows that, in the case of acute sleep deprivation, the resulting slopes for ground lost and ground recouped (mean ± SE across subjects) were significantly different (paired t-test, t(11) = 5.17, p < 0.001), indicating poor saccadic compensation. However, when sleep loss was coupled with caffeine ingestion, ground lost was decreased and ground recouped increased such that the slopes were no longer different (t(8) = -0.05, p = 0.965). With alcohol, the two slopes were large albeit not significantly different (t(15) = 0.96, p = 0.351), indicating significant pursuit impairment but effective saccadic compensation. Our findings show that sleep deprivation and alcohol affect oculomotor performance differently. Low-dose alcohol effects appear predominantly cortical, with effective brainstem compensation. Sleep loss and circadian disruption however appears to affect both cortical and brainstem pathways with caffeine providing an effective countermeasure to both effects. Beyond the mere detection of impairment, our oculometric assessment allows us to characterize the nature of the deficit, to provide insight into the neural substrate, and to assess the effectiveness of countermeasures.

pursuit↗

NXIS - Well integrity inspection in unconventional gas wells

The objective of this project is to advance the state-of-the-art and to develop an integrity inspection system capable of detecting physical flaws in the wellbore structure of conventional and unconventional hydrocarbon producing wells. Measuring the integrity of multiple wellbore casings and cement annuli for onshore and offshore wells remains a challenging task. We propose a multi-modality inspection system composed of neutron and X(gamma)-ray imaging modalities (nXis) to address the above challenge. The functional principle of this wellbore integrity inspection system is the combination of high-energy modalities, such as X(gamma)-ray and neutron backscatter imaging, with conventional low-energy modalities, such as electromagnetic or ultrasound imaging techniques. By combining multiple sensing modalities into one sensing system and by fusing data between modalities, one can gather more information about the integrity of the wellbore structure compared to simply using multiple sensors individually. Imaging prototypes for gamma, neutron, and electromagnetics were designed, manufactured, and tested at GE Global Research and Starfire Industries. Wellbore phantoms with engineered defects were manufactured and the performance of the developed wellbore integrity inspection tool prototypes was evaluated in a test pit test at an industrial GE Oil & Gas facility. Data analysis and fusion between various inspection techniques show enhanced defect detectability. These exciting results were presented at various technical conferences and discussed with operators in the oil & gas industry. Great interest from oil operators lead to discussions about joint industrial partnerships to move the developed technology from the prototype phase to the product phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3-D MAPPING TECHNOLOGIES FOR HIGH LEVEL WASTE TANKS

This research investigated four techniques that could be applicable for mapping of solids remaining in radioactive waste tanks at the Savannah River Site: stereo vision, LIDAR, flash LIDAR, and Structure from Motion (SfM). Stereo vision is the least appropriate technique for the solids mapping application. Although the equipment cost is low and repackaging would be fairly simple, the algorithms to create a 3D image from stereo vision would require significant further development and may not even be applicable since stereo vision works by finding disparity in feature point locations from the images taken by the cameras. When minimal variation in visual texture exists for an area of interest, it becomes difficult for the software to detect correspondences for that object. SfM appears to be appropriate for solids mapping in waste tanks. However, equipment development would be required for positioning and movement of the camera in the tank space to enable capturing a sequence of images of the scene. Since SfM requires the identification of distinctive features and associates those features to their corresponding instantiations in the other image frames, mockup testing would be required to determine the applicability of SfM technology for mapping of waste in tanks. There may be too few features to track between image frame sequences to employ the SfM technology since uniform appearance may exist when viewing the remaining solids in the interior of the waste tanks. Although scanning LIDAR appears to be an adequate solution, the expense of the equipment ($80,000-$120,000) and the need for further development to allow tank deployment may prohibit utilizing this technology. The development would include repackaging of equipment to permit deployment through the 4-inch access ports and to keep the equipment relatively uncontaminated to allow use in additional tanks. 3D flash LIDAR has a number of advantages over stereo vision, scanning LIDAR, and SfM, including full frame time-of-flight data (3D image) collected with a single laser pulse, high frame rates, direct calculation of range, blur-free images without motion distortion, no need for precision scanning mechanisms, ability to combine 3D flash LIDAR with 2D cameras for 2D texture over 3D depth, and no moving parts. The major disadvantage of the 3D flash LIDAR camera is the cost of approximately $150,000, not including the software development time and repackaging of the camera for deployment in the waste tanks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PJM Controller Testing with Prototypic PJM Nozzle Configuration

The U.S. Department of Energy (DOE) Office of River Protection’s Waste Treatment Plant (WTP) is being designed and built to pre-treat and then vitrify a large portion of the wastes in Hanford’s 177 underground waste storage tanks. The WTP consists of three primary facilities—pretreatment, low-activity waste (LAW) vitrification, and high-level waste (HLW) vitrification. The pretreatment facility will receive waste piped from the Hanford tank farms and separate it into a high-volume, low-activity liquid stream stripped of most solids and radionuclides and a much smaller volume of HLW slurry containing most of the solids and most of the radioactivity. Many of the vessels in the pretreatment facility will contain pulse jet mixers (PJM) that will provide some or all of the mixing in the vessels. Pulse jet mixer technology was selected for use in black cell regions of the WTP, where maintenance cannot be performed once hot testing and operations commence. The PJMs have no moving mechanical parts that require maintenance. The vessels with the most concentrated slurries will also be mixed with air spargers and/or steady jets in addition to the mixing provided by the PJMs. Pulse jet mixers are susceptible to overblows that can generate large hydrodynamic forces, forces that can damage mixing vessels or their internal parts. The probability of an overblow increases if a PJM does not fill completely. The purpose of the testing performed for this report was to determine how reliable and repeatable the primary and safety (or backup) PJM control systems are at detecting drive overblows (DOB) and charge vessel full (CVF) conditions. Testing was performed on the ABB 800xA and Triconex control systems. The controllers operated an array of four PJMs installed in an approximately 13 ft diameter × 15 ft tall tank located in the high bay of the Pacific Northwest National Laboratory (PNNL) 336 Building test facility. The PJMs were fitted with 4 inch diameter discharge nozzles representative of the nozzles to be used in the WTP. This work supplemented earlier controller tests done on PJMs with 2 inch nozzles (Bontha et al. 2007). Those earlier tests enabled the selection of appropriate pressure transmitters with associated piping and resulted in an alternate overblow detection algorithm that uses data from pressure transmitters mounted in a water flush line on the PJM airlines. Much of that earlier work was only qualitative, however, due to a data logger equipment failure that occurred during the 2007 testing. The objectives of the current work focused on providing quantitative determinations of the ability of the BNI controllers to detect DOB and CVF conditions. On both control systems, a DOB or CVF is indicated when the values of particular internal functions, called confidence values, cross predetermined thresholds. There are two types of confidence values; one based on a transformation of jet pump pair (JPP) drive and suction pressures, the other based on the pressure in the flush line. In the present testing, we collected confidence levels output from the ABB and Triconex controllers. These data were analyzed in terms of the true and noise confidence peaks generated during multiple cycles of DOB and CVF events. The distributions of peak and noise amplitudes were compared to see if thresholds could be set that would enable the detection of DOB and CVF events at high probabilities, while keeping false detections to low probabilities. Supporting data were also collected on PJM operation, including data on PJM pressures and levels, to provide direct experimental evidence of when PJMs were filling, full, driving, or overblowing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The NASA/AFRL Meter Class Autonomous Telescope

For the past decade, the NASA Orbital Debris Program Office (ODPO) has relied on using various ground-based telescopes in Chile to acquire statistical survey data as well as photometric and spectroscopic data of orbital debris in geosynchronous Earth orbit (GEO). The statistical survey data have been used to supply the Orbital Debris Engineering Model (ORDEM) v.3.0 with debris detections in GEO to better model the environment at altitudes where radar detections are limited. The data produced for the statistical survey ranged from 30 to 40 nights per year, which only accounted for ~10% of the possible observing time. Data collection was restricted by ODPO resources and weather conditions. In order to improve the statistical sampling in GEO, as well as observe and sample other orbits, NASA's ODPO with support from the Air Force Research Laboratory (AFRL), has constructed a new observatory dedicated to orbital debris - the Meter Class Autonomous Telescope (MCAT) on Ascension Island. This location provides MCAT with the unique ability to access targets orbiting at an altitude of less than 1,000 km and low inclinations (< 20 deg). This orbital regime currently has little to no coverage by the U.S. Space Surveillance Network. Unlike previous ODPO optical assets, the ability to operate autonomously will allow rapid response observations of break-up events, an observing mode that was only available via radar tasking prior to MCAT's deployment. The primary goal of MCAT is to statistically characterize GEO via daily tasking files uploaded from ODPO. These tasking files define which operating mode to follow, providing the field center, rates, and/or targets to observe over the entire observing period. The system is also capable of tracking fast-moving targets in low Earth orbit (LEO), middle Earth orbit (MEO), as well as highly eccentric orbits like geostationary transfer orbits. On 25 August 2015, MCAT successfully acquired scientific first light, imaging the Bug Nebula and tracked objects in LEO, MEO, and GEO. NASA is working towards characterizing the system and thoroughly testing the integrated hardware and software control to achieve fully autonomous operations by late 2016. This paper will review the history and current status of the MCAT project, the details of the telescope system, and its five currently manifested operating modes.

Cowardin, H.↗

Detection of cosmic superstrings by geodesic test particle motion

(p,q)-strings are bound states of p F-strings and q D-strings and are predicted to form at the end of brane inflation. As such, these cosmic superstrings should be detectable in the Universe. In this paper we argue that they can be detected by the way that massive and massless test particles move in the space-time of these cosmic superstrings. In particular, we study solutions to the geodesic equation in the space-time of field theoretical (p,q)-strings. The geodesics can be classified according to the test particles' energy, angular momentum and momentum in the direction of the string axis. We discuss how the change of the magnetic fluxes, the ratio between the symmetry-breaking scale and the Planck mass, the Higgs-to-gauge-boson mass ratios and the binding between the F- and D-strings, respectively, influence the motion of the test particles. While massless test particles can move only on escape orbits, a new feature as compared to the infinitely thin string limit is the existence of bound orbits for massive test particles. In particular, we observe that--in contrast to the space-time of a single Abelian-Higgs string--bound orbits for massive test particles in (p,q)-string space-times are possible if the Higgs boson mass is larger than the gauge boson mass. We also compute the effect of the binding between the p- and the q-string on observables such as the light deflection and the perihelion shift. While light deflection can also be caused by other matter distributions, the possibility of a negative perihelion shift seems to be a feature of finite width cosmic strings that could lead to the unmistakable identification of such objects. In Melvin space-times, which are asymptotically nonconical, massive test particles have to move on bound orbits, while massless test particles can escape to infinity only if their angular momentum vanishes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Closure Report for Corrective Action Unit 408: Bomblet Target Area Tonopah Test Range (TTR), Nevada, Revision 0

This Closure Report (CR) presents information supporting the closure of Corrective Action Unit (CAU) 408: Bomblet Target Area (TTR), Tonopah Test Range, Nevada. This CR complies with the requirements of the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; U.S. Department of Energy (DOE), Environmental Management; U.S. Department of Defense; and DOE, Legacy Management. Corrective Action Unit 408 is located at the Tonopah Test Range, Nevada, and consists of Corrective Action Site (CAS) TA-55-002-TAB2, Bomblet Target Areas. This CAS includes the following seven target areas: • Mid Target • Flightline Bomblet Location • Strategic Air Command (SAC) Target Location 1 • SAC Target Location 2 • South Antelope Lake • Tomahawk Location 1 • Tomahawk Location 2 The purpose of this CR is to provide documentation supporting the completed corrective actions and data confirming that the closure objectives for the CAS within CAU 408 were met. To achieve this, the following actions were performed: • Review the current site conditions, including the concentration and extent of contamination. • Implement any corrective actions necessary to protect human health and the environment. • Properly dispose of corrective action and investigation wastes. • Document Notice of Completion and closure of CAU 408 issued by the Nevada Division of Environmental Protection. From July 2009 through August 2010, closure activities were performed as set forth in the Streamlined Approach for Environmental Restoration Plan for CAU 408: Bomblet Target Area, Tonopah Test Range (TTR), Nevada. The purposes of the activities as defined during the data quality objectives process were as follows: • Identify and remove munitions of explosive concern (MEC) associated with DOE activities. • Investigate potential disposal pit locations. • Remove depleted uranium-contaminated fragments and soil. • Determine whether contaminants of concern (COCs) are present. • If COCs are present, determine their nature and extent, implement appropriate corrective actions, and properly dispose of wastes. Analytes detected during the closure activities were evaluated against final action levels to determine COCs for CAU 408. Assessment of the data indicated COCs are not present at CAS TA-55-002-TAB2; therefore, no corrective action is necessary. No use restrictions are required to be placed on this CAU because the investigation showed no evidence of remaining soil contamination or remaining debris/waste upon completion of all investigation activities. The MEC was successfully removed and dispositioned as planned using current best available technologies. As MEC guidance and general MEC standards acknowledge that MEC response actions cannot determine with 100 percent certainty that all MEC and unexploded ordnance (UXO) are removed, the clean closure of CAU 408 will implement a best management practice of posting UXO hazard warning signs near the seven target areas. The signs will warn future land users of the potential for encountering residual UXO hazards. The DOE, National Nuclear Security Administration Nevada Site Office, provides the following recommendations: • A Notice of Completion to the DOE, National Nuclear Security Administration Nevada Site Office, is requested from the Nevada Division of Environmental Protection for closure of CAU 408. • Corrective Action Unit 408 should be moved from Appendix III to Appendix IV of the Federal Facility Agreement and Consent Order.

54 ENVIRONMENTAL SCIENCES↗

Development of the Intelligent, Preventive Infrared (IR) Inspection System Housed in Hybrid Robotic Platforms

Robots and robotic systems that are designed for inspection, environmental study, and health and safety aid are becoming an increasing necessity. However, there is a number of challenges that accompany robots that are designed for these specific applications. These challenges include: navigating compact, enclosed spaces, travelling over multiple terrains and large obstacles, using the proper sensing and detection methods to assess an environment, and the use of lightweight and durable materials. The robotic platforms currently in development look at all of these challenges and attempt to overcome them. These designs specific use of hybrid robotic platforms, or platform that utilizes soft and rigid materials, allows for a more flexible platform and makes environments more navigable. To further improve the navigation of the platforms and environmental assessment, a novel infrared detection system is housed in the platforms to create a robot that can be used for the applications listed above and more. Objectives: Further develop two types of robotic platforms that utilize additive manufacturing, soft materials, and rigid materials. Continue the development of an intelligent and inhibitory infrared detection system based on an artificial intelligence (AI) algorithm. Continued study and fabrication of active soft materials designed for both sensing and actuation in hybrid robotic systems. Improve additive manufacturing fabrication to design rigid and semi-rigid components for hybrid robotic platforms. Transformable Wheel Robotic Platform: The chassis, wheels, tires and inspection system housing use different additive manufacturing techniques for fabrication. Continued work with additive manufacturing has lead to studies in metal-based printing and modular design and manufacturing. The new platform design with integrated electrical component printed. This will allow integration of the sensor housing onto the platform. Electrical components are being tested for battery life and performance. To improve this performance, such as integration of Lithium Polymer (LiPo) batteries. Snake Robotic Platform: The main focus of the development has centered around liquid-based soft actuators. That act on the principles of electrostatic and hydraulic actuation. A liquid dielectric sits between two compliant electrodes, contained by a flexible polymer shell. The electrodes and film gradually collapse toward each other from one corner of the electrode to the other. When the electrodes and film close together, a majority of the fluid is pushed into the area not covered by an electrode. A thin layer of the liquid dielectric remains between the electrode. The actuators will be stacked to cause large displacement, and move the linkages. The chassis of this platform uses purely additively manufactured linkages. Intelligent, Preventive IR Inspection System: Development of the AI for the system has lead to using a Scikit-Learn which assists in creating predictive models based on Regression, clustering, classification etc. To improve the infrared thermometry for low emissivity sources, work on the fabrication of a tandem photoconductive infrared thermometer was a main focus. Distance-Voltage-Temperature response data has been collected in the range of 7 cm - 100 cm and 200-400 deg. C. Modifications were made to the existing test bench to have a better control over the data. Automated data collection was realized using a Python code and an Arduino controlled stepper motor to increase the sample rate. A protective enclosure has been built around the setup to minimize the effect of the environment on the measurements. To better predict temperature, different AI models are being optimized. The regression model, LARS showed a high accuracy but had convergence issues and only works for the current test set-up. Results: The Transformable Wheel Robot has developed into a more flexible and modular platform. With the improvements to the current work, effort on the tire or soft gripper design been a large focus. The soft grippers will be interchange able to allow for increased performance in identified terrain types. The development of the liquid-based actuators allows the snake robotic platform to achieve the goals of being flexible and able to navigate confined spaces. However, there is room for improvement. Optimization work is currently being done in COMSOL Multiphysics. With the current IR system set-up the LARS model perfectly predicts the data; however, considering the mobility aspect of the project other models will allow for an optimized system. Testing of other model types is currently being done.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗