Use of HDF and HDF-EOS in MISR standard data producs and ancillary datasets
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We are in the early stages of work on EPA task to investigate the effects of fires on air quality in North America, led by Jennifer Logan of Harvard University. JPL's contribution to this study is to find thousands of smoke plumes in satellite images of North America, and derive statistics about their geographic distribution, extent, orientation, and injection height.
Explore the source record for details and available documents.
Support Vector Machines (SVMs) are a type of supervised learning algorith,, other examples of which are Artificial Neural Networks (ANNs), Decision Trees, and Naive Bayesian Classifiers. Supervised learning algorithms are used to classify objects labled by a 'supervisor' - typically a human 'expert.'.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Techniques for passive remote sensing of aerosol optical and microphysical properties from space include visible, near and shortwave-infrared imaging (e.g., from MODIS), multiangle intensity imaging (e.g., ATSR-2, AATSR, MISR), near-ultraviolet mapping (e.g., TOMSIOMI), and polarimetry (e.g., POLDER, APS). Each of these methods has unique strengths. In this paper, we present a concept for integrating these approaches into a unified sensor. Design goals include spectral coverage from the near-UV to the shortwave infrared; intensity and polarimetric imaging simultaneously at multiple view angles; global coverage within a few days; kilometer to sub-kilometer spatial resolution; and measurement of the degree of linear polarization (DOLP) for a subset of the spectral complement with an uncertainty of 0.5% or less.
The MISR instrument consists of nine pushbroom cameras which measure radiance in four spectral bands. Global coverage is achieved in nine days. The cameras are arranged with one camera pointing toward the nadir, four cameras pointing forward and four cameras pointing aftward. It takes 7 minutes for all nine cameras to view the same surface location. The view angles relative to the surface reference ellipsoid, are 0, 26.1, 45.6, 60.0, and 70.5 degrees. The spectral band shapes are nominally gaussian, centered at 443, 555, 670, and 865 nm. The Terrain data are re-projected to the terrain altitude. In this product, surface data from all cameras will appear in the same geographic location. Thus, this product is the primary input to Level 2 aerosol/surface processing, which requires co-registration of the L1B2 imagery at the surface. Clouds will still be displaced due to their elevation above the surface, but this time with respect to the terrain rather than the ellipsoid. (The mountain location T is now assigned the geographic location at T, and the Cloud at F appears at the geographic location T.) In Level 2 aerosol/surface processing, algorithms are applied to screen out the clouds. Terrain data only exist for MISR blocks containing some land. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=563.2 km (cross-track); Longitude_Resolution=140.8 km (along-track).; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=about 15 orbits/day].
The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1.1 km; Longitude_Resolution=1.1 km; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=about 15 orbits/day].
The MISR instrument consists of nine pushbroom cameras which measure radiance in four spectral bands. Global coverage is achieved in nine days. The cameras are arranged with one camera pointing toward the nadir, four cameras pointing forward and four cameras pointing aftward. It takes 7 minutes for all nine cameras to view the same surface location. The view angles relative to the surface reference ellipsoid, are 0, 26.1, 45.6, 60.0, and 70.5 degrees. The spectral band shapes are nominally gaussian, centered at 443, 555, 670, and 865 nm. The RCCM is derived from the radiance values, and is calculated independently for each camera. Therefore, the amount of apparent cloudiness will vary with view angle, with the oblique view angles generally being more cloudy than the near-nadir ones. Since the RCCM is calculated primarily from the radiance values, it does not work well over snow and ice and will usually confuse clear snow/ice with cloud. It works the best over clear-sky ocean, but other surface types are also of quite good quality. The RCCM product also contains a glint mask for each camera, and this mask is set to true whenever the scattering angles indicate that glint could be possible. This glint mask is not masked out over land; users must do this step themselves. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180].
Passive multiangular, multispectral, and polarimetric sensing approaches each have unique strengths for the measurement of tropospheric aerosol column abundances and microphysical properties. Current spaceborne multispectral and multiangular aerosols sensors operate at approximately 1 km resolution. Under NASA's Instrument Incubator Program, we are developing an electro-optic imaging approach that will enable adding high-accuracy polarimetry to such observations. To achieve a degree of linear polarization (DOLP) uncertainty of 0.5%, our approach temporally modulates the linear-polarization component of incoming light at a rapid rate, enabling each detector within a focal-plane array, combined with polarization analyzers, to measure the relative proportions of the linear Stokes components Q or U to the total intensity. Our system uses tandem photoelastic modulators (PEMs) within a high-reflectance, low diattenuation camera design. The two PEMs vibrate at slightly different resonant frequencies, leading to modulation of the polarized light at a heterodyne frequency of ~25 Hz. High-speed (1 kHz) readout of the detector arrays samples the output waveforms from which Q/I and U/I are derived. We report on experimental and theoretical analyses of PEM and optical system performance, along with plans for developing ruggedized PEMs capable of withstanding launch and on-orbit stresses.
Multi-camera stereo imaging of cloud features from the MISR (Multiangle Imaging SpectroRadiometer) instrument on NASA's Terra satellite provides accurate and precise measurements of cloud top heights (CTH) and cloud motion vector (CMV) winds. MISR observes each cloudy scene from nine viewing angles (Nadir, +/-26(sup o), +/-46(sup o), +/-60(sup o), +/-70(sup o)) with approximatel 275-m pixel resolution. This paper provides an update on MISR CMV and CTH algorithm improvements, and explores a high-resolution retrieval of tangential winds inside the eyewall of tropical cyclones (TC). The MISR CMV and CTH retrievals from the updated algorithm are significantly improved in terms of spatial coverage and systematic errors. A new product, the 1.1-km cross-track wind, provides high accuracy and precision in measuring convective outflows. Preliminary results obtained from the 1.1-km tangential wind retrieval inside the TC eyewall show that the inner-core rotation is often faster near the eyewall, and this faster rotation appears to be related linearly to cyclone intensity.
No abstract available
Topics include: MINX Document 1 MISR : The instrument, its orbit and data products. MINX Document 2 MISR : Tools for ordering and viewing data. MINX Document 3 : MINX : Overview and plume case studies. MINX Document 4 : MINX basic features. MINX Document 5 : Measuring aerosol height and motion with MINX. MINX Document 5 : Handling complexities in height retrievals. Plume boundaries, Wind direction, Low Optical Thickness, Other complexities. Digitizing options. Managing plume projects.
No abstract available