Search NASA⌕ Search

SEARCH · Search NASA

Results for “nozzles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Effect of silicone oil on nozzle heat transfer in solid propellant rockets

The feasibility of reducing heat transfer rates to inert nozzle walls in solid rockets by addition of silicone oil as a propellant ingredient is explored experimentally. A metallized control propellant and its counterpart with 1% silicone oil are fired in a 2 1/2-in. diameter end burning all-metal burner. Pressure-time histories are obtained; temperature-time data at the nozzle throat are obtained in some of the runs. The heat loss by the product gases to the cold inert walls of the nozzle lower the temperature of the gases leading to the condensation of aluminum oxide on the walls. This condensation is used as an index of the heat transfer rate to the nozzle. On a statistical basis it is found that the silicone propellant gives practically no condensation in 70% of the firings contrasted with 21% for its counterpart with no silicone oil in it. The gas temperature at the nozzle throat is experimentally seen to be generally higher with the silicone propellant than with its counterpart; this higher temperature is consistent with a preliminary analysis that is used here to relate the nozzle surface temperature to the heat transfer from the product gases.

Ramohalli, K.↗

Experimental study of coaxial nozzle exhaust noise

Experimental results are presented for static acoustic model tests of various geometrical configurations of coaxial nozzles operating over a range of flow conditions. The geometrical configurations consisted of nozzles with coplanar and non-coplanar exit planes and various exhaust area ratios. Primary and secondary nozzle flows were varied independently over a range of nozzle pressure ratios from 1.4 to 3.0 and gas temperatures from 280 to 1100 K. Acoustic data are presented for the conventional mode of coaxial nozzle operation as well as for the inverted velocity profile mode. Comparisons are presented to show the effect of configuration and flow changes on the acoustic characteristics of the nozzles.

Goodykoontz, J. H.↗

Experimental study of coaxial nozzle exhaust noise

Experimental results are presented for static acoustic model tests of various geometrical configurations of coaxial nozzles operating over a range of flow conditions. The geometrical configurations consisted of nozzles with coplanar and non-coplanar exit planes and various exhaust area ratios. Primary and secondary nozzle flows were varied independently over a range of nozzle pressure ratios from 1.4 to 3.0 and gas temperatures from 280 to 1100 K. Acoustic data are presented for the conventional mode of coaxial nozzle operation as well as for the inverted velocity profile mode. Comparisons are presented to show the effect of configuration and flow changes on the acoustic characteristics of the nozzles.

Goodykoontz, J. H.↗

Noise suppression due to annulus shaping of an inverted-velocity-profile coaxial nozzle

An inverted velocity profile coaxial nozzle for use with supersonic cruise aircraft produces less jet noise than an equivalent conical nozzle. Furthermore, decreasing the annulus height (increasing radius ratio with constant flow) results in further noise reduction benefits. The annulus shape (height) was varied by an eccentric mounting of the annular nozzle with respect to a conical core nozzle. Acoustic measurements were made in the flyover plane below the narrowest portion of the annulus and at 90 deg and 180 deg from this point. The model-scale spectra are scaled up to engine size (1.07 m diameter) and the perceived noise levels for the eccentric and baseline concentric inverted velocity profile coaxial nozzles are compared over a range of operating conditions. The implications of the acoustic benefits derived with the eccentric nozzle to practical applications are discussed.

Goodykoontz, J.↗

Experimental aerodynamic and acoustic model testing of the Variable Cycle Engine (VCE) testbed coannular exhaust nozzle system

Aerodynamic performance and jet noise characteristics of a one sixth scale model of the variable cycle engine testbed exhaust system were obtained in a series of static tests over a range of simulated engine operating conditions. Model acoustic data were acquired. Data were compared to predictions of coannular model nozzle performance. The model, tested with an without a hardwall ejector, had a total flow area equivalent to a 0.127 meter (5 inch) diameter conical nozzle with a 0.65 fan to primary nozzle area ratio and a 0.82 fan nozzle radius ratio. Fan stream temperatures and velocities were varied from 422 K to 1089 K (760 R to 1960 R) and 434 to 755 meters per second (1423 to 2477 feet per second). Primary stream properties were varied from 589 to 1089 K (1060 R to 1960 R) and 353 to 600 meters per second (1158 to 1968 feet per second). Exhaust plume velocity surveys were conducted at one operating condition with and without the ejector installed. Thirty aerodynamic performance data points were obtained with an unheated air supply. Fan nozzle pressure ratio was varied from 1.8 to 3.2 at a constant primary pressure ratio of 1.6; primary pressure ratio was varied from 1.4 to 2.4 while holding fan pressure ratio constant at 2.4. Operation with the ejector increased nozzle thrust coefficient 0.2 to 0.4 percent.

Nelson, D. P.↗

The effect of throat contouring on two-dimensional converging-diverging nozzles at static conditions

An experiment was conducted at static conditions to determine the internal performance effects of nozzle throat contouring, the result of increasing the circular-arc throat radius. Five nonaxisymmetric converging-diverging nozzles were tested at nozzle pressure ratios up to 9.0. Data are presented as internal thrust ratios, discharge coefficients, and static-pressure distributions. Comparisons of internal performance data for the five nozzles show that throat contouring increases the value of discharge coefficient but has no significant effect on internal thrust ratio except in cases of internal flow separation. To illustrate the use of the two dimensional converging-diverging (2-D C-D) nozzle data base, a two dimensional inviscid theory was applied to the five configurations. The generally good agreement of data with theoretical results indicates that two-dimensional inviscid theory can be successfully applied to the prediction of 2-D C-D nozzle internal flow.

Mason, M. L.↗

Noise suppression due to annulus shaping of an inverted-velocity-profile coaxial nozzle

Previous studies have shown that an inverted-velocity-profile coaxial nozzle for use with supersonic cruise aircraft produces less jet noise than an equivalent conical nozzle. Furthermore, decreasing the annulus height (increasing radius ratio with constant flow) results in further noise reduction benefits. In the present model-scale study, the annulus shape, that is, height, was varied by an eccentric mounting of the annular nozzle with respect to a conical core nozzle. Acoustic measurements were made in the flyover plane below the narrowest portion of the annulus and at 90 deg and 180 deg from this point. The model-scale spectra are scaled up to engine size (1.07 m diameter) and the perceived noise levels for the eccentric and baseline concentric inverted-velocity-profile coaxial nozzles are compared over a range of operating conditions. The implications of the acoustic benefits derived with the eccentric nozzle to practical applications are discussed.

Goodykoontz, J.↗

Characteristics of internal- and jet-noise radiation from a multi-lobe, multi-tube suppressor nozzle tested statically and under flight simulation

Nozzle transmission coefficient (NTC) for a 12-lobe, 24-tube suppressor nozzle and a reference round convergent nozzle of equal area are obtained by an impulse test technique. This technique utilizes a high voltage spark discharge as a noise source within the test duct. Effects of nozzle geometry, jet Mach number, jet temperature and flight velocity on the radiation characteristics of the two nozzles are presented. Likewise, the jet mixing noise measured in the absence of internal noise for both nozzles at static and also simulated flight conditions are discussed.

Ahuja, K. K.↗

CF6-50 Short Core Exhaust Nozzle

The General Electric CF6-50 engine nacelle was originally equipped with both fan nozzle and core nozzle thrust reversers. Many airline operators later deactivated the core reverser. Elimination of the core reverser enabled design changes to be made to help improve performance. A reduction in core nozzle length of approximately two feet was possible. This concept, defined as the Short Core Exhaust Nozzle, was evaluated in engine ground tests, including performance, acoustic, and endurance tests under the NASA/Lewis Engine Component Improvement Program. The test results verified the performance predictions from scale model tests. The Short Core Exhaust Nozzle provides an internal cruise SFC reduction of 0.9% without an increase in engine noise. The nozzle hardware successfully completed 1000 flight cycles of endurance testing with no signs of distress.

Dusa, D. J.↗

Flight and tunnel test results of the MDC mechanical jet noise suppressor nozzle

The flight and wind tunnel tests to determine the acoustic and performance effects of a mechanical jet noise suppressor nozzle mounted on a Viper engine of an HS-125 airplane are discussed. Flyover noise measurements were made with microphones mounted on top of a 137.5 m bridge tower. Seven nozzle configurations including two references nozzles, two suppressors, and three ejector inlets were tested. The suppressor nozzle of interest for an advanced supersonic transport, the suppressor/treated ejector, achieved a measured noise reduction of 14 EPNdB relative to a conventional conical reference nozzle at the highest pressure ratio tested (approximately 2.5). The unique engine nacelle, flight hardware, and nacelles from the HS-125 flight test program, combined with a simulated HS-125 fuselage were windtunnel tested. Both propulsion and acoustic data were recorded. Preliminary thrust data results from the wind tunnel tests are summarized and compared to other mechanical suppressor test results. The test results indicate that a noise reduction of at least 16 EPNdB would be possible for the suppressor/ejector nozzle scaled to typical AST engine size with a 5% thrust loss at a typical takeoff climb speed.

Fitzsimmons, R. D.↗

Jet-diffuser Ejector - Attached Nozzle Design

Attached primary nozzles were developed to replace the detached nozzles of jet-diffuser ejectors. Slotted primary nozzles located at the inlet lip and injecting fluid normal to the thrust axis, and rotating the fluid into the thrust direction using the Coanda Effect were investigated. Experiments indicated excessive skin friction or momentum cancellation due to impingement of opposing jets resulted in performance degradation. This indicated a desirability for location and orientation of the injection point at positions removed from the immediate vicinity of the inlet surface, and at an acute angle with respect to the thrust axis. Various nozzle designs were tested over a range of positions and orientations. The problems of aircraft integration of the ejector, and internal and external nozzle losses were also considered and a geometry for the attached nozzles was selected. The effect of leaks, protrusions, and asymmetries in the ejector surfaces was examined. The results indicated a relative insensitivity to all surface irregularities, except for large protrusions at the throat of the ejector.

Alperin, M.↗

Mixer nozzle aeroacoustic characteristics for the energy efficient engine

Aeroacoustic tests are conducted on scale model mixer nozzle configurations, a separate flow nozzle, and a baseline conical nozzle in an anechoic chamber free-jet facility to investigate exhaust system designs. Far-field acoustic data and exhaust jet plume aerodynamic data are obtained for various combinations of exhaust jet velocity and simulated flight speed, with corrected microphone data at a constant 12.2 m arc distance, and scaled acoustic data at a sideline distance of 457 m. It is found that jet plume aerodynamic and acoustic characteristics of lobed mixer exhaust systems are similar to those of a conical nozzle operating at the same specific thrust, although differences occur at high frequencies, where the sound pressure level of the mixer nozzle is 1-5 dB higher than that of a conical nozzle. In addition, no direct correlation is found between exit plane turbulence levels and plume development or acoustic characteristics for mixer exhaust configurations.

Gliebe, P. R.↗

Static internal performance characteristics of two thrust reverser concepts for axisymmetric nozzles

The statis performance of two axisymmetric nozzle thrust reverser concepts was investigated. A rotating vane thrust reverser represented a concept in which reversing is accomplished upstream of the nozzle throat, and a three door reverser concept provided reversing downstream of the nozzle throat. Nozzle pressure ratio was varied from 2.0 to approximately 6.0. The results of this investigation indicate that both the rotating vane and three door reverser concepts were effective static thrust spoilers with the landing approach nozzle geometry and were capable of providing at least a 50 percent reversal of static thrust when fully deployed with the ground roll nozzle geometry.

Leavitt, L. D.↗

Aeropropulsive characteristics of Mach numbers up to 2.2 of axisymmetric and nonaxisymmetric nozzles installed on an F-18 model

An investigation to determine the aeropropulsive characteristics of nonaxisymmetric nozzles on an F-18 jet effects model was conducted in the Langley 16-foot transonic tunnel and the AEDC 16-foot supersonic wind tunnel. The performance of a two dimensional convergent-divergent nozzle, a single expansion ramp nozzle, and a wedge nozzle was compared with that of the baseline axisymmetric nozzle. Test data were obtained at static conditions and at Mach numbers from 0.60 to 2.20 at an angle of attack of 0 deg. Nozzle pressure ratio was varied from jet-off to about 20.

Capone, F. J.↗

Assessment of NASA and RAE viscous-inviscid interaction methods for predicting transonic flow over nozzle afterbodies

The Langley Research Center of the National Aeronautics and Space Administration and the Royal Aircraft Establishment have undertaken a cooperative program to conduct an assessment of their patched viscous-inviscid interaction methods for predicting the transonic flow over nozzle afterbodies. The assessment was made by comparing the predictions of the two methods with experimental pressure distributions and boattail pressure drag for several convergent circular-arc nozzle configurations. Comparisons of the predictions of the two methods with the experimental data showed that both methods provided good predictions of the flow characteristics of nozzles with attached boundary layer flow. The RAE method also provided reasonable predictions of the pressure distributions and drag for the nozzles investigated that had separated boundary layers. The NASA method provided good predictions of the pressure distribution on separated flow nozzles that had relatively thin boundary layers. However, the NASA method was in poor agreement with experiment for separated nozzles with thick boundary layers due primarily to deficiencies in the method used to predict the separation location.

Putnam, L. E.↗

Static internal performance including thrust vectoring and reversing of two-dimensional convergent-divergent nozzles

The effects of geometric design parameters on two dimensional convergent-divergent nozzles were investigated at nozzle pressure ratios up to 12 in the static test facility. Forward flight (dry and afterburning power settings), vectored-thrust (afterburning power setting), and reverse-thrust (dry power setting) nozzles were investigated. The nozzles had thrust vector angles from 0 deg to 20.26 deg, throat aspect ratios of 3.696 to 7.612, throat radii from sharp to 2.738 cm, expansion ratios from 1.089 to 1.797, and various sidewall lengths. The results indicate that unvectored two dimensional convergent-divergent nozzles have static internal performance comparable to axisymmetric nozzles with similar expansion ratios.

Re, R. J.↗

Investigation of arcjet nozzle performance

An investigation is performed to examine the feasibility of improving arcjet performance through the use of contoured nozzle designs. The results of preliminary experiments performed on two different nozzle configurations, a 19 degree half-angle cone and a 'bell' shaped nozzle, are described. A unique experimental arcjet apparatus, which effectively tests only the change in nozzle contour on arcjet performance is used in this investigation. The preliminary experimental results indicate approximately an 8 percent improvement in thrust and specific impulse for operation at 15 kW with an ammonia flow rate of 0.20 g/s for a 'bell' shaped nozzle compared to a conical nozzle.

Brophy, J. R.↗

Pitot-Pressure Measurements in Flow Fields Behind a Rectangular Nozzle with Exhaust Jet for Free-Stream Mach Numbers of 0.00, 0.60, and 1.20

An investigation has been conducted in the Langley 16-Foot Transonic Tunnel to measure the flow field in and around the jet exhaust from a nonaxisymmetric nozzle configuration. The nozzle had a rectangular exit with a width-to-height ratio of 2.38. Pitot-pressure measurements were made at five longitudinal locations downstream of the nozzle exit. The maximum distance downstream of the exit was about 5 nozzle heights. These measurements were made at free-stream Mach numbers of 0.00, 0.60, and 1.20 with the nozzle operating at a ratio of nozzle total pressure to free-stream static pressure of 4.0. The jet exhaust was simulated with high-pressure air that had an exit total temperature essentially equal to the free-stream total temperature.

Putnam, L. E.↗