Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Compact femtosecond electron diffractometer with 100 keV electron bunches approaching the single-electron pulse duration limit

We present the design and implementation of a highly compact femtosecond electron diffractometer working at electron energies up to 100 keV. We use a multi-body particle tracing code to simulate electron bunch propagation through the setup and to calculate pulse durations at the sample position. Our simulations show that electron bunches containing few thousands of electrons per bunch are only weakly broadened by space-charge effects and their pulse duration is thus close to the one of a single-electron wavepacket. With our compact setup, we can create electron bunches containing up to 5000 electrons with a pulse duration below 100 fs on the sample. We use the diffractometer to track the energy transfer from photoexcited electrons to the lattice in a thin film of titanium. This process takes place on the timescale of few-hundred femtoseconds and a fully equilibrated state is reached within 1 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FPGA-Based Self-Calibrating Time-to-Digital Converter for Time-of-Flight Experiments

We describe the architecture of a FPGA-based self-calibrating Time to Digital Converter (TDC), specifically intended to measure the width of an input pulse. The configuration consists of two controllable ring oscillators with a very small difference in their frequencies, wherein this difference determines the achievable resolution. The calibration scheme relies on an accurate pulse-generator or external crystal-oscillator to provide a stable calibration pulse for the system. We implemented the TDC on an Altera Stratix II device where we measured a Least Significant Bit of 41 ps (an RMS resolution of 11.8 ps). We present details of the methods used to calibrate the TDC, the characterization process, and discuss the effects of variations in temperature and voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image-based spectral distortion correction for photon-counting x-ray detectors

Purpose: To investigate the feasibility of using an image-based method to correct for distortions induced by various artifacts in the x-ray spectrum recorded with photon-counting detectors for their application in breast computed tomography (CT). Methods: The polyenergetic incident spectrum was simulated with the tungsten anode spectral model using the interpolating polynomials (TASMIP) code and carefully calibrated to match the x-ray tube in this study. Experiments were performed on a Cadmium-Zinc-Telluride (CZT) photon-counting detector with five energy thresholds. Energy bins were adjusted to evenly distribute the recorded counts above the noise floor. BR12 phantoms of various thicknesses were used for calibration. A nonlinear function was selected to fit the count correlation between the simulated and the measured spectra in the calibration process. To evaluate the proposed spectral distortion correction method, an empirical fitting derived from the calibration process was applied on the raw images recorded for polymethyl methacrylate (PMMA) phantoms of 8.7, 48.8, and 100.0 mm. Both the corrected counts and the effective attenuation coefficient were compared to the simulated values for each of the five energy bins. The feasibility of applying the proposed method to quantitative material decomposition was tested using a dual-energy imaging technique with a three-material phantom that consisted of water, lipid, and protein. The performance of the spectral distortion correction method was quantified using the relative root-mean-square (RMS) error with respect to the expected values from simulations or areal analysis of the decomposition phantom. Results: The implementation of the proposed method reduced the relative RMS error of the output counts in the five energy bins with respect to the simulated incident counts from 23.0%, 33.0%, and 54.0% to 1.2%, 1.8%, and 7.7% for 8.7, 48.8, and 100.0 mm PMMA phantoms, respectively. The accuracy of the effective attenuation coefficient of PMMA estimate was also improved with the proposed spectral distortion correction. Finally, the relative RMS error of water, lipid, and protein decompositions in dual-energy imaging was significantly reduced from 53.4% to 6.8% after correction was applied. Conclusions: The study demonstrated that dramatic distortions in the recorded raw image yielded from a photon-counting detector could be expected, which presents great challenges for applying the quantitative material decomposition method in spectral CT. The proposed semi-empirical correction method can effectively reduce these errors caused by various artifacts, including pulse pileup and charge sharing effects. Furthermore, rather than detector-specific simulation packages, the method requires a relatively simple calibration process and knowledge about the incident spectrum. Therefore, it may be used as a generalized procedure for the spectral distortion correction of different photon-counting detectors in clinical breast CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPND Sensitivity Calculations Using MCNP and Experimental Data from ACRR

The use of the Monte Carlo N-Particle Transport Code (MCNP) to calculate detector sensitivity for Self-Powered Neutron Detectors (SPNDs) in the Annular Core Research Reactor (ACRR) could be a vital tool in the effort to optimize the design of next-generation SPNDs. Next-generation SPND designs, which consider specific materials and geometry, may provide experimenters with capabilities for advanced mixed field dosimetry. These detectors will need to be optimized for configuration, materials, and geometries and the ability to model and iterate must be available in order to decide on the ideal. SPND design. SPNDs were modeled in MCNP which closely resembled the dimensions and location of actual detectors used in the ACRR. Tallies were used to calculate detector sensitivity. Using metrics from a previous report, oscilloscope data from pulses were manipulated in a Matrix Laboratory computing environment (MATLAB) script to calculate experimental detector sensitivity. This report outlines the process in which experimental data from ACRR pulses verified results from tallies in an MCNP ACRR model. The sensitivity values from experiments and MCNP calculations agreed within one standard deviation. Parametric studies were also performed with MCNP to investigate the effects of materials and dimensions of different SPNDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon detection studied by pulse-height energy analysis: Novel converter arrangements

Muons are conventionally measured by a plastic scintillator–photomultiplier detector. Muons from processes in ultra-dense hydrogen H(0) are detected here by a novel type of converter in front of a photomultiplier. The muon detection yield can be increased relative to that observed with a plastic scintillator by at least a factor of 100, using a converter of metal, semiconductor (Ge), or glass for interaction with the muons penetrating through the metal housing of the detector. This detection process is due to transient formation of excited nuclei by the well-known process of muon capture, giving beta decay. The main experimental results shown here are in the form of beta electron energy spectra detected directly by the photomultiplier. Events which give a high-energy tail in the energy spectra are probably due to gamma photons from the muons. Sharp and intense x-ray peaks from a muonic aluminium converter or housing material are observed. The detection conversion in glass and Ge converters has a time constant of the order of many minutes to reach the final conversion level, while the process in metal converters is stabilized faster. The time constants are not due to lifetimes of the excited nuclei or neutrons but are due to internal charging in the insulating converter material. Interaction of this charging with the high voltage in the photomultiplier is observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Internal-conversion process in superintense ultrashort x-ray pulses

The electron-nucleus interaction in a super-intense few-cycle x-ray pulse is investigated. The super-intense few-cycle x-ray pulse-induced internal conversion (IC) process is discussed in detail. The x-ray laser-pulse induced IC coefficient is calculated, and in particular, it is derived in the case of a pulse of Gaussian shape and for a bound-free electron transition. The IC coefficient of the IC process induced by a super-intense few-cycle soft-x-ray laser pulse in the case of the {sup 99m}Tc isomer is determined numerically. The results obtained for the IC coefficient show significant carrier angular frequency, carrier-envelope phase, and pulse-length dependencies. The infinite pulse-length limit and experimental aspects are also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantization effects in radiation spectroscopy based on digital pulse processing

Radiation spectra represent inherently quantization data in the form of stacked channels of equal width. The spectrum is an experimental measurement of the discrete probability density function (PDF) of the detector pulse heights. The quantization granularity of the spectra depends on the total number of channels covering the full range of pulse heights. In analog pulse processing the total number of channels is equal to the total digital values produced by a spectroscopy analog-to-digital converter (ADC). In digital pulse processing each detector pulse is sampled and quantized by a fast ADC producing certain number of quantized numerical values. These digital values are linearly processed to obtain a digital quantity representing the peak of the digitally shaped pulse. Using digital pulse processing it is possible to acquire a spectrum with the total number of channels greater than the number of ADC values. Noise and sample averaging are important in the transformation of ADC quantized data into spectral quantized data. Analysis of this transformation is performed using an area sampling model of quantization. Spectrum differential nonlinearity (DNL) is shown to be related to the quantization at low noise levels and small number of averaged samples. Theoretical analysis and experimental measurements are used to obtain the condition to minimize the DNL due to quantization. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE INTERMEDIATE NEUTRON-CAPTURE PROCESS AND CARBON-ENHANCED METAL-POOR STARS

Carbon-enhanced metal-poor (CEMP) stars in the Galactic Halo display enrichments in heavy elements associated with either the s (slow) or the r (rapid) neutron-capture process (e.g., barium and europium, respectively), and in some cases they display evidence of both. The abundance patterns of these CEMP- s / r stars, which show both Ba and Eu enrichment, are particularly puzzling, since the s and the r processes require neutron densities that are more than ten orders of magnitude apart and, hence, are thought to occur in very different stellar sites with very different physical conditions. We investigate whether the abundance patterns of CEMP- s / r stars can arise from the nucleosynthesis of the intermediate neutron-capture process (the i process), which is characterized by neutron densities between those of the s and the r processes. Using nuclear network calculations, we study neutron capture nucleosynthesis at different constant neutron densities n ranging from 10{sup 7}–10{sup 15} cm{sup -3}. With respect to the classical s process resulting from neutron densities on the lowest side of this range, neutron densities on the highest side result in abundance patterns, which show an increased production of heavy s -process and r -process elements, but similar abundances of the light s -process elements. Such high values of n may occur in the thermal pulses of asymptotic giant branch stars due to proton ingestion episodes. Comparison to the surface abundances of 20 CEMP- s / r stars shows that our modeled i -process abundances successfully reproduce observed abundance patterns, which could not be previously explained by s -process nucleosynthesis. Because the i -process models fit the abundances of CEMP- s / r stars so well, we propose that this class should be renamed as CEMP- i .

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of impurity confinement on Alcator C-Mod using a multi-pulse laser blow-off system

A new laser blow-off system for use in impurity transport studies on Alcator C-Mod was developed and installed for the 2009 run campaign. Its design included capabilities for multiple impurity injections during a single plasma pulse and remote manipulation of the ablated spot size. The system uses a 0.68 J, Nd:YAG laser operating at up to 10 Hz coupled with the fast beam steering via a 2D piezoelectric mirror mount able to move spot locations in the 100 ms between laser pulses and a remote controllable optical train that allow ablated spot sizes to vary from {approx}0.5 to 7 mm. The ability to ablate a wide range in target Z along with Alcator C-Mod's extensive diagnostic capabilities (soft x-ray, vacuum ultraviolet (VUV), charge exchange spectroscopy, etc.) allows for detailed studies of the impurity transport dependencies and mechanisms. This system has demonstrated the achievement of all its design goals including the ability for non-perturbative operation allowing for insight into underlying impurity transport processes. A detailed overview of the laser blow-off system and initial results of operation are presented. This includes an investigation into the characterization of impurity confinement in the I-mode confinement regime recently investigated on C-Mod.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling pulse characteristics in Xenon with NEST

In this paper, a comprehensive model for describing the characteristics of pulsed signals, generated by particle interactions in xenon detectors, is presented. An emphasis is laid on two-phase time projection chambers, but the models presented are also applicable to single phase detectors. In order to simulate the pulse shape due to primary scintillation light, the effects of the ratio of singlet and triplet dimer state populations, as well as their corresponding decay times, and the recombination time are incorporated into the model. In a two phase time projection chamber, when simulating the pulse caused by electroluminescence light, the ionization electron mean free path in gas, the drift velocity, singlet and triplet decay times, diffusion constants, and the electron trapping time, have been implemented. Finally, this modeling has been incorporated into a complete software package, which realistically simulates the expected pulse shapes for these types of detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of T-odd asymmetry of the emission of light charged particles and photons during fission of heavy nuclei by polarized neutrons

The new physical effects of T-odd asymmetry of the emission of light charged particles (LCPs) during the ternary fission of some heavy nuclei by cold polarized neutrons have been experimentally studied. The coefficients of triple scalar and vector correlation of the pulses of light particles and fission fragments (TRI effect) and the fivefold correlation of the same vectors (ROT effect) have been measured. These effects are believed to be caused by the rotation of polarized fissioning system around its polarization direction. The treatment of the experimental data for LCPs in the framework of this hypothesis leads to a good agreement between the calculation results and experimental data. The calculated value of the angle of rotation of the fission axis in the ternary fission of the polarized fissioning {sup 236}U* compound nucleus was used to process the results of measuring the ROT effect for {gamma} photons from binary-fission fragments of the same nucleus. A satisfactory description of these experimental data is obtained which serves a convincing confirmation of the rotation hypothesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chaoticity parameter {lambda} and multiple coherent components in relativistic heavy-ion collisions

Three-pion correlations are conventionally analyzed using a chaotic component and a single coherent component of the emitted pions. The existence of source coherence in these experiments is suggested, but the detailed structure of the coherent component remains obscure. An improved understanding of the coherent processes is obtained by incorporating into the model general properties of pulsed radiation, inspired by the free-electron laser operation with multiple, mutually independent coherent source currents due to electron microbunching. This approach with multiple coherent components solves an inconsistency in the earlier three-pion data analysis and leads to a more appealing description of the experimental results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HiSPoD : a program for high-speed polychromatic X-ray diffraction experiments and data analysis on polycrystalline samples

Here, a high-speed X-ray diffraction technique was recently developed at the 32-ID-B beamline of the Advanced Photon Source for studying highly dynamic, yet non-repeatable and irreversible, materials processes. In experiments, the microstructure evolution in a single material event is probed by recording a series of diffraction patterns with extremely short exposure time and high frame rate. Owing to the limited flux in a short pulse and the polychromatic nature of the incident X-rays, analysis of the diffraction data is challenging. Here, HiSPoD , a stand-alone Matlab-based software for analyzing the polychromatic X-ray diffraction data from polycrystalline samples, is described. With HiSPoD , researchers are able to perform diffraction peak indexing, extraction of one-dimensional intensity profiles by integrating a two-dimensional diffraction pattern, and, more importantly, quantitative numerical simulations to obtain precise sample structure information.

36 MATERIALS SCIENCE↗

Comprehensive defect evaluation of advanced nuclear fuels using high-resolution acoustic signals and optimized sensor separation

Graphite pebble composite structures based on TRistructural-ISOtropic (TRISO) particles are being developed as core nuclear fuels in advanced power reactors, promising safe operation at increased temperatures. Ensuring the structural integrity of these nuclear fuels requires comprehensive and accurate non-destructive evaluation (NDE) techniques to characterize defects and damage in the pebbles. However, traditional acoustic evaluation methods face limitations in defect characterization due to the highly attenuative, and geometrically and compositionally complex nature of these structures. This study proposes an improved acoustic NDE technique for accurate detection and classification of anticipated relevant defects and damage in graphite pebbles using high-resolution acoustic signals and optimized transmit-receive sensor networks. The proposed approach utilizes a triangular three-sensor network as the base unit, comprising three transmit-receive sensors. The sensor separation distance, as well as acoustic excitation center frequency, pulse-width, and bandwidth are optimized to enhance spatial resolution and improve signal-to-noise ratio, enabling effective characterization of the smallest size and widest range of defects in pebbles. Furthermore, the use of the triangular sensor configuration instead of a more conventional transmit-receive sensor pair expands the inspection region from a one-dimensional linear path to a two-dimensional area, increasing spatial coverage. To mitigate challenges associated with processing of complex acoustic signals arising from high-frequency, high-bandwidth excitation in these structures, a machine-learning-based signal processing algorithm is integrated with the sensor network. In the machine-learning-based algorithm, multi-domain features are extracted from the acoustic signals to capture intricate signal characteristics, significantly improving defect identification and classification compared to traditional approaches. The proposed acoustic NDE technique offers considerable promise for practical and reliable defect/damage diagnostics of advanced nuclear pebble fuels.

42 ENGINEERING↗

Irradiation tests in BR2 of miniature fission chambers in pulse, Campbelling and current mode

The FNDS system ('Fast Neutron Detection System') for the on-line in-pile detection of the fast neutron flux in the presence of a significant thermal neutron flux and a high gamma dose rate is being developed in the framework of the SCK.CEN-CEA Laboratoire Commun. The system has been patented in 2008. The system consists of a miniature Pu-242 fission chamber as main detector, complemented by a U-235 fission chamber or a rhodium Self-Powered Neutron Detector (SPND) for thermal neutron flux monitoring and a dedicated acquisition system that also takes care of the processing of the signals from both detectors to extract fast neutron flux data. This paper describes a FNDS qualification experiment in the SCK.CEN BR2 reactor, with experimental results on a large set of fission chambers in current and Campbelling mode. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sierra/SolidMechanics for Target Pulse Analysis

Sierra is a Multiphysics engineering simulation software suite developed and maintained by Sandia National Laboratories. Created for nuclear weapon needs, it is available to national laboratories with a foreign national restriction. The STS Target Systems analysis team is interested in using Sierra to perform explicit dynamics simulations of the tantalum clad tungsten target blocks as a response to sudden temperature changes induced by proton beam pulses. The capability already exists with Abaqus|Explicit, however, there are time and cost limitations due to licensing. The following document serves as a “quick-start” guide to the successful setup, simulation, and post-processing of a target model in Sierra on the OZ3 computing cluster at the Spallation Neutron Source.

97 MATHEMATICS AND COMPUTING↗

Ionic Liquids: Radiation Chemistry, Solvation Dynamics and Reactivity Patterns

Ionic liquids (ILs) are a rapidly expanding family of condensed-phase media with important applications in energy production, nuclear fuel and waste processing, improving the efficiency and safety of industrial chemical processes, and pollution prevention. ILs are generally nonvolatile, noncombustible, highly conductive, recyclable and capable of dissolving a wide variety of materials. They are finding new uses in chemical synthesis, catalysis, separations chemistry, electrochemistry and other areas. Ionic liquids have dramatically different properties compared to conventional molecular solvents, and they provide a new and unusual environment to test our theoretical understanding of charge transfer and other reactions. We are interested in how IL properties influence physical and dynamical processes that determine the stability and lifetimes of reactive intermediates and thereby affect the courses of chemical reactions and product distributions. Successful use of ionic liquids in radiation-filled environments, where their safety advantages could be significant, requires an understanding of ionic liquid radiation chemistry. For example, characterizing the primary steps of IL radiolysis will reveal radiolytic degradation pathways and suggest ways to prevent them or mitigate their effects on the properties of the material. An understanding of ionic liquid radiation chemistry will also facilitate pulse radiolysis studies of general chemical reactivity in ILs, which will aid in the development of applications listed above. Very early in our radiolysis studies it became evident that slow solvation dynamics of the excess electron in ILs (which vary over a wide viscosity range) increases the importance of pre-solvated electron reactivity and consequently alters product distributions. Parallel studies of IL solvation phenomena using coumarin-153 dynamic Stokes shifts and polarization anisotropy decay rates are done to compare with electron solvation studies and to evaluate the influence of ILs on charge transport processes. Picosecond pulse radiolysis studies at BNL's Laser-Electron Accelerator Facility (LEAF) are used to identify reactive species in ionic liquids and measure their solvation and reaction rates. We and our collaborators (R. Engel (Queens College, CUNY) and S. Lall-Ramnarine, (Queensborough CC, CUNY)) develop and characterize new ionic liquids specifically designed for our radiolysis and solvation dynamics studies. IL solvation and rotational dynamics are measured by TCSPC and fluorescence upconversion measurements in the laboratory of E. W. Castner at Rutgers Univ. Investigations of radical species in irradiated ILs are carried out at ANL by I. Shkrob and S. Chemerisov using EPR spectroscopy. Diffusion rates are obtained by PGSE NMR in S. Greenbaum's lab at Hunter College, CUNY and S. Chung's lab at William Patterson U. Professor Mark Kobrak of CUNY Brooklyn College performs molecular dynamics simulations of solvation processes. A collaboration with M. Dietz at U. Wisc. Milwaukee is centered around the properties and radiolytic behavior of ionic liquids for nuclear separations. Collaborations with C. Reed (UC Riverside), D. Gabel (U. Bremen) and J. Davis (U. South Alabama) are aimed at characterizing the radiolytic and other properties of borated ionic liquids, which could be used to make fissile material separations processes inherently safe from criticality accidents.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laser-initiated p – 11 B fusion reactions in petawatt high-repetition-rate laser facilities

Driving of the nuclear fusion reaction p + 11 B → 3α + 8.7 MeV under laboratory conditions by interaction between high-power laser pulses and matter has become a popular field of research, owing to its numerous potential applications: as an alternative to deuterium–tritium for fusion energy production, astrophysics studies, and alpha-particle generation for medical treatment. One possible scheme for laser-driven p– 11 B reactions is to direct a beam of laser-accelerated protons onto a boron (B) sample (the so-called “pitcher-catcher” scheme). This technique has been successfully implemented on large high-energy lasers, yielding hundreds of joules per shot at low repetition. We present here a complementary approach, exploiting the high repetition rate of the VEGA III petawatt laser at CLPU (Spain), aiming at accumulating results from many interactions at much lower energy, to provide better control of the parameters and the statistics of the measurements. Despite a moderate energy per pulse, our experiment allowed exploration of the laser-driven fusion process with tens (up to hundreds) of laser shots. The experiment provided a clear signature of the reactions involved and of the fusion products, accumulated over many shots, leading to an improved optimization of the diagnostics for experimental campaigns of this type. In this paper, we discuss the effectiveness of laser-driven p– 11 B fusion in the pitcher–catcher scheme, at a high repetition rate, addressing the challenges of this experimental scheme and highlighting its critical aspects. Our proposed methodology allows evaluation of the performance of this scheme for laser-driven alpha particle production and can be adapted to high-repetition-rate laser facilities with higher energy and intensity.

Alpha particles↗