Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

High power diode lasers for solid-state laser pumps

The development and commercial application of high power diode laser arrays for use as solid-state laser pumps is described. Such solid-state laser pumps are significantly more efficient and reliable than conventional flash-lamps. This paper describes the design and fabrication of diode lasers emitting in the 780 - 900 nm spectral region, and discusses their performance and reliability. Typical measured performance parameters include electrical-to-optical power conversion efficiencies of 50 percent, narrow-band spectral emission of 2 to 3 nm FWHM, pulsed output power levels of 50 watts/bar with reliability values of over 2 billion shots to date (tests to be terminated after 10 billion shots), and reliable operation to pulse lengths of 1 ms. Pulse lengths up to 5 ms have been demonstrated at derated power levels, and CW performance at various power levels has been evaluated in a 'bar-in-groove' laser package. These high-power 1-cm stacked-bar arrays are now being manufactured for OEM use. Individual diode laser bars, ready for package-mounting by OEM customers, are being sold as commodity items. Commercial and medical applications of these laser arrays include solid-state laser pumping for metal-working, cutting, industrial measurement and control, ranging, wind-shear/atmospheric turbulence detection, X-ray generation, materials surface cleaning, microsurgery, ophthalmology, dermatology, and dental procedures.

Linden, Kurt J.↗

An Internal Digital Image Correlation Technique for High-Strain Rate Dynamic Experiments

Full-field, quantitative visualization techniques, such as digital image correlation (DIC), have unlocked vast opportunities for experimental mechanics. However, DIC has traditionally been a surface measurement technique, and has not been extended to perform measurements on the interior of specimens for dynamic, full-scale laboratory experiments. This limitation restricts the scope of physics which can be investigated through DIC measurements, especially in the context of heterogeneous materials. The focus of this study is to develop a method for performing internal DIC measurements in dynamic experiments. The aim is to demonstrate its feasibility and accuracy across a range of stresses (up to 650 MPa), strain rates (10 3 - 10 6 s -1 ), and high-strain rate loading conditions (e.g., ramped and shock wave loading). Internal DIC is developed based on the concept of applying a speckle pattern at an inner-plane of a transparent specimen. The high-speed imaging configuration is coupled to the traditional dynamic experimental setups, and is focused on the internal speckle pattern. During the experiment, while the sample deforms dynamically, in-plane, two-dimensional deformations are measured via correlation of the internal speckle pattern. In this study, the viability and accuracy of the internal DIC technique is demonstrated for split-Hopkinson (Kolsky) pressure bar (SHPB) and plate impact experiments. The internal DIC experimental technique is successfully demonstrated in both the SHPB and plate impact experiments. In the SHPB setting, the accuracy of the technique is excellent throughout the deformation regime, with measurement noise of approximately 0.2% strain. In the case of plate impact experiments, the technique performs well, with error and measurement noise of 1% strain. The internal DIC technique has been developed and demonstrated to work well for full-scale dynamic high-strain rate and shock laboratory experiments, and the accuracy is quantified. Here, the technique can aid in investigating the physics and mechanics of the dynamic behavior of materials, including local deformation fields around dynamically loaded material heterogeneities.

36 MATERIALS SCIENCE↗

Evidence of Dirac Quantum Spin Liquid in YbZn 2⁢ GaO 5

The emergence of a quantum spin liquid (QSL), a state of matter that can result when electron spins are highly correlated but do not become ordered, has been the subject of a considerable body of research in condensed matter physics [1,2]. Spin liquid states have been proposed as hosts for high-temperature superconductivity [3] and can host topological properties with potential applications in quantum information science [4]. The excitations of most quantum spin liquids are not conventional spin waves but rather quasiparticles known as spinons, whose existence is well established experimentally only in one-dimensional systems; the unambiguous experimental realization of QSL behavior in higher dimensions remains challenging. Here, in this work, we investigate the novel compound $YbZn_{2}GaO_{5}$, which hosts an ideal triangular lattice of effective spin-1/2 moments with no detectable inherent chemical disorder. Thermodynamic and inelastic neutron scattering measurements performed on high-quality single crystal samples of $YbZn_{2}GaO_{5}$ exclude the possibility of long-range magnetic ordering down to 0.06 K, demonstrate a quadratic power law for the specific heat and reveal a continuum of magnetic excitations in parts of the Brillouin zone. Both low-temperature thermodynamics and inelastic neutron scattering spectra suggest that $YbZn_{2}GaO_{5}$ is a U(1) Dirac QSL with spinon excitations concentrated at certain points in the Brillouin zone. We advanced these results by performing additional specific heat measurements under finite fields, further confirming the theoretical expectations for a Dirac QSL on the triangular lattice of $YbZn_{2}GaO_{5}$.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of the use of an electronic multifunction display and an electromechanical horizontal situation indicator for guidance and control of powered-lift short-haul aircraft

The use which pilots make of a moving map display from en route through the terminal area and including the approach and go-around flight phases was investigated. The content and function of each of three primary STOLAND displays are reviewed from an operational point of view. The primary displays are the electronic attitude director indicator (EADI), the horizontal situation indicator (HSI), and the multifunction display (MFD). Manually controlled flight with both flight director guidance and raw situation data is examined in detail in a simulated flight experiment with emphasis on tracking reference flight plans and maintaining geographic orientation after missed approaches. Eye-point-of-regard and workload measurements, coupled with task performance measurements, pilot opinion ratings, and pilot comments are presented. The experimental program was designed to offer a systematic objective and subjective comparison of pilots' use of the moving map MFD in conjunction with the other displays.

Clement, W. F.↗

Rectenna array measurement results

The measured performance characteristics of a rectenna array are reviewed and compared to the performance of a single element. It is shown that the performance may be extrapolated from the individual element to that of the collection of elements. Techniques for current and voltage combining are demonstrated. The array performance as a function of various operating parameters is characterized and techniques for overvoltage protection and automatic fault clearing in the array are demonstrated. A method for detecting failed elements also exists. Instrumentation for deriving performance effectiveness is described. Measured harmonic radiation patterns and fundamental frequency scattered patterns for a low level illumination rectenna array are presented.

Dickinson, R. M.↗

Rectenna array measurement results

The measured performance characteristics of a rectenna array are reviewed and compared to the performance of a single element. It is shown that the performance may be extrapolated from the individual element to that of the collection of elements. Techniques for current and voltage combining were demonstrated. The array performance as a function of various operating parameters is characterized and techniques for overvoltage protection and automatic fault clearing in the array demonstrated. A method for detecting failed elements also exists. Instrumentation for deriving performance effectiveness is described. Measured harmonic radiation patterns and fundamental frequency scattered patterns for a low level illumination rectenna array are presented.

Dickinson, R. M.↗

The Deep Space Network: Noise temperature concepts, measurements, and performance

The use of higher operational frequencies is being investigated for improved performance of the Deep Space Network. Noise temperature and noise figure concepts are used to describe the noise performance of these receiving systems. The ultimate sensitivity of a linear receiving system is limited by the thermal noise of the source and the quantum noise of the receiver amplifier. The atmosphere, antenna and receiver amplifier of an Earth station receiving system are analyzed separately and as a system. Performance evaluation and error analysis techniques are investigated. System noise temperature and antenna gain parameters are combined to give an overall system figure of merit G/T. Radiometers are used to perform radio ""star'' antenna and system sensitivity calibrations. These are analyzed and the performance of several types compared to an idealized total power radiometer. The theory of radiative transfer is applicable to the analysis of transmission medium loss. A power series solution in terms of the transmission medium loss is given for the solution of the noise temperature contribution.

Stelzried, C. T.↗

Comparative evaluation of twenty pilot workload assessment measure using a psychomotor task in a moving base aircraft simulator

A comparison of the sensitivity and intrusion of twenty pilot workload assessment techniques was conducted using a psychomotor loading task in a three degree of freedom moving base aircraft simulator. The twenty techniques included opinion measures, spare mental capacity measures, physiological measures, eye behavior measures, and primary task performance measures. The primary task was an instrument landing system (ILS) approach and landing. All measures were recorded between the outer marker and the middle marker on the approach. Three levels (low, medium, and high) of psychomotor load were obtained by the combined manipulation of windgust disturbance level and simulated aircraft pitch stability. Six instrument rated pilots participated in four seasons lasting approximately three hours each.

Connor, S. A.↗

Causes of dissociation between subjective workload measures and performance - Caveats for the use of subjective assessments

Dissociations between subjective workload assessments and performance were investigated. The difficulty of a Sternberg memory search task was manipulated by varying stimulus presentation rate, stimulus discernibility, value of good performance, and automaticity of performance. All Sternberg task conditions were performed both alone and concurrently with a tracking task. Bipolar subjective workload assessments were collected. Dissociations between workload and performance were found related to automaticity, presentation rate, and motivation level. The results were interpreted as supporting the hypothesis that the specific cognitive processes responsible for subjective assessments can differ from those responsible for performance. The potential contamination these dissociations could inflict on operational workload assessments is discussed.

Vidulich, M. A.↗

Measured ground performance and predicted orbital performance of the superfluid helium dewar for the Cosmic Background Explorer

A critical component of the Cosmic Background Explorer observatory, which is to be lifted to orbit in 1988, is the 650-l superfluid He dewar housing a far-IR absolute spectrophotometer and a diffuse IR background experiment. Attention is presently given to the results of a four-month-long test program encompassing dewar filling verification, vibration characteristics, thermal performance over orbital lifetime, and aperture cover ejection behavior. No significant flaws have been noted; the orbital cryogen lifetime is projected to be 14 months.

Hopkins, Richard A.↗

Comparisons of predicted and measured rotor performance in hover using a new free wake analysis

A new free-wake analysis has been developed to predict the performance of rotors in hover and axial flight. The analysis finds the rotor wake geometry using a novel influence coefficient/relaxation scheme. In this paper, the features of the analysis are reviewed, and the accuracy of the analysis is assessed for a wide range of rotor configurations in hover and vertical climb. The effects of variations in the analysis parameters are addressed, and recommendations for future development are presented. Generally good results were obtained for the predicted performance of a wide range of rotor geometries and operating conditions without any special 'tuning' of the analysis. The analysis also provides predictions of rotor performance in vertical climb that are substantially more accurate than momentum theory.

Felker, Fort F.↗

Terrestrial gravity instrumentation in the 20th Century: A brief review

At the turn of the century, only pendulum apparatuses and torsion balances were available for general exploration work. Both of these early techniques were cumbersome and time-consuming. It was no wonder that the development of the gravity meter was welcomed with a universal sigh of relief. By 1935 potential field measurements with gravity meters supplanted gradient measurements with torsion balances. Potential field measurements are generally characterized by three types: absolute - measurements are made in fundamental units, traceable to national standards of length and time at each observation site; relative with absolute scale - differences in gravity are measured in fundamental units traceable to national standards of length and time; and relative - differences in gravity are measured with arbitrary scale. Improvements in the design of gravity meters since their introduction has led to a significant reduction in size and greatly increased precision. As the precision increased, applications expanded to include the measurement of crustal motion, the search for non-Newtonian forces, archeology, and civil engineering. Apart from enhancements to the astatic gravity meter, few developments in hardware were achieved. One of these was the vibrating string gravity meter which was developed in the 1950s and was employed briefly for marine and borehole applications. Another is the cryogenic gravity meter which utilizes the stability of superconducting current to achieve a relative instrument with extremely low drift suitable for tidal and secular gravity measurements. An advance in performing measurements from a moving platform was achieved with the development of the straight-line gravity meter. The latter part of the century also saw the rebirth of gradient measurements which offers advantages for observations from a moving platform. Definitive testing of the Bell gradiometer was recently reported.

Valliant, H. D.↗

A system performance throughput model applicable to advanced manned telescience systems

As automated space systems become more complex, autonomous, and opaque to the flight crew, it becomes increasingly difficult to determine whether the total system is performing as it should. Some of the complex and interrelated human performance measurement issues are addressed that are related to total system validation. An evaluative throughput model is presented which can be used to generate a human operator-related benchmark or figure of merit for a given system which involves humans at the input and output ends as well as other automated intelligent agents. The concept of sustained and accurate command/control data information transfer is introduced. The first two input parameters of the model involve nominal and off-nominal predicted events. The first of these calls for a detailed task analysis while the second is for a contingency event assessment. The last two required input parameters involving actual (measured) events, namely human performance and continuous semi-automated system performance. An expression combining these four parameters was found using digital simulations and identical, representative, random data to yield the smallest variance.

Haines, Richard F.↗