Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel array detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Photon noise correlations in millimeter-wave telescopes

Many modern millimeter and submillimeter (“mm-wave”) telescopes for astronomy are deploying more detectors by increasing the detector pixel density and, with the rise of lithographed detector architectures and high-throughput readout techniques, it is becoming increasingly practical to overfill the focal plane. However, when the pixel pitch p pix is small compared to the product of the wavelength λ and the focal ratio F , or p pix ≲1.2 F λ , the Bose term of the photon noise correlates between neighboring detector pixels due to the Hanbury Brown and Twiss (HBT) effect. When this HBT effect is non-negligible, the array-averaged sensitivity scales with the detector count N det less favorably than the uncorrelated limit of N det −1/2 . In this paper, we present a general prescription to calculate this HBT correlation based on a quantum optics formalism and extend it to polarization-sensitive detectors. We then estimate the impact of HBT correlations on the sensitivity of a model mm-wave telescope and discuss the implications for a focal plane design.

Hill, Charles A. (ORCID:0000000226416878)↗

The First Multichroic Polarimeter Array on the Atacama Cosmology Telescope: Characterization and Performance

The Atacama Cosmology Telescope Polarimeter (ACTPol) is a polarization sensitive receiver for the 6-meter Atacama Cosmology Telescope (ACT) and measures the small angular scale polarization anisotropies in the cosmic microwave background (CMB). The full focal plane is composed of three detector arrays, containing over 3000 transition edge sensors (TES detectors) in total. The first two detector arrays, observing at 146 gigahertz, were deployed in 2013 and 2014, respectively. The third and final array is composed of multichroic pixels sensitive to both 90 and 146 gigahertz and saw first light in February 2015. Fabricated at NIST, this dichroic array consists of 255 pixels, with a total of 1020 polarization sensitive bolometers and is coupled to the telescope with a monolithic array of broad-band silicon feedhorns. The detectors are read out using time-division SQUID multiplexing and cooled by a dilution refrigerator at 110 meter Kelvins. We present an overview of the assembly and characterization of this multichroic array in the lab, and the initial detector performance in Chile. The detector array has a TES detector electrical yield of 85 percent, a total array sensitivity of less than 10 microns Kelvin root mean square speed, and detector time constants and saturation powers suitable for ACT CMB observations.

Ho, S. P.↗

Application of a single area array detector for acquistion, tracking and point-ahead in space optical communications

Functions of acquisition, tracking, and point-ahead in space optical communications are being combined into a single system utilizing an area array detector. An analysis is presented of the feasibility concept. The key parameters are: optical power less than 1 pW at 0.86 micrometer, acquisition in less than 30 seconds in an acquisition field of view (FOV) of 1 mrad, tracking with 0.5 microrad rms noise at 1000 Hz update rate, and point ahead transfer function precision of 0.25 microrad over a region of 150 microrad. Currently available array detectors were examined. The most demanding specifications are low output noise, a high detection efficiency, a large number of pixels, and frame rates over 1kHz. A proof of concept (POC) demonstration system is currently being built utilizing the Kodak HS-40 detector (a 128 x 128 photodiode array with a 64 channel CCD readout architecture which can be operated at frame rates as high as 40,000/sec). The POC system implements a windowing scheme and special purpose digital signal processing electronic for matched filter acquisition and tracking algorithms.

Clark, D. L.↗

Application of a single area array detector for acquisition, tracking and point-ahead in space optical communications

Functions of acquisition, tracking, and point-ahead in space optical communications are being combined into a single system utilizing an area array detector. An analysis is presented of the feasibility concept. The key parameters are: optical power less than 1 pW at 0.86 micrometer, acquisition in less than 30 seconds in an acquisition field of view (FOV) of 1 mrad, tracking with 0.5 microrad rms noise at 1000 Hz update rate, and point ahead transfer function precision of 0.25 microrad over a region of 150 microrad. Currently available array detectors were examined. The most demanding specifications are low output noise, a high detection efficiency, a large number of pixels, and frame rates over 1kHz. A proof of concept (POC) demonstration system is currently being built utilizing the Kodak HS-40 detector (a 128 x 128 photodiode array with a 64 channel CCD readout architecture which can be operated at frame rates as high as 40,000/sec). The POC system implements a windowing scheme and special purpose digital signal processing electronic for matched filter acquisition and tracking algorithms.

Clark, D. L.↗

Corrugated Quantum Well Infrared Photodetector Focal Plane Array Test Results

The corrugated quantum-well infrared photodetector (C-QWIP) uses total internal reflection to couple normal incident light into the optically active quantum wells. The coupling efficiency has been shown to be relatively independent of the pixel size and wavelength thus making the C-QWIP a candidate for detectors over the entire infrared spectrum. The broadband coupling efficiency of the C-QWIP makes it an ideal candidate for multiwavelength detectors. We fabricated and tested C-QWIP focal plane arrays (FPAs) with cutoff wavelengths of 11.2 and 16.2 micrometers. Each FPA has 256 x 256 pixels that are bump-bonded to a direct injection readout circuit. Both FPAs provided infrared imagery with good aesthetic attributes. For the 11.2-micrometers FPA, background-limited performance (BLIP) was observed at 60 K with f/3 optics. For the 16.2-micrometers FPA, BLIP was observed at 38 K. Besides the reduction of dark current in C-QWIP structures, the measured internal quantum efficiency (eta) remains to be high. The values for responsivity and quantum efficiency obtained from the FPA results agree well with those measured for single devices.

Goldberg, A.↗

Studies of Avalanche Photodiodes (APDS) as Readout Devices for Scintillating Fibers for High Energy Gamma-Ray Astronomy Telescopes

New gamma ray and charged particle telescope designs based on scintillating fiber arrays could provide low cost, high resolution, lightweight, very large area and multi radiation length instrumentation for planned NASA space exploration. The scintillating fibers low visible light output requires readout sensors with single photon detection sensitivity and low noise. The sensitivity of silicon Avalanche Photodiodes (APDS) matches well the spectral output of the scintillating fibers. Moreover, APDs have demonstrated single photon capability. The global aim of our work is to make available to NASA a novel optical detector concept to be used as scintillating fiber readouts and meeting the requirements of the new generations of space-borne gamma ray telescopes. We proposed to evaluate the feasibility of using RMD's small area APDs ((mu)APD) as scintillating fiber readouts and to study possible alternative (mu)APD array configurations for space borne readout scintillating fiber systems, requiring several hundred thousand to one million channels. The evaluation has been conducted in accordance with the task description and technical specifications detailed in the NASA solicitation "Studies of Avalanche Photodiodes (APD as readout devices for scintillating fibers for High Energy Gamma-Ray Astronomy Telescopes" (#8-W-7-ES-13672NAIS) posted on October 23, 1997. The feasibility study we propose builds on recent developments of silicon APD arrays and light concentrators advances at RMD, Inc. and on more than 5 years of expertise in scintillating fiber detectors. In a previous program we carried out the initial research to develop a high resolution, small pixel, solid-state, silicon APD array which exhibited very high sensitivity in the UV-VIS spectrum. This (mu)APD array is operated in Geiger mode and results in high gain (greater than 10(exp 8)), extremely low noise, single photon detection capability, low quiescent power (less than 10 (mu)W/pixel for 30 micrometers sensitive area diameter) and output in the 1-5 volt range. If successful, this feasibility study will make possible the development of a scintillating fiber detector with unsurpassed sensitivity, extremely low power usage, a crucial factor of merit for space based sensors and telescopes.

Vasile, Stefan↗

Intra-Pixel Response Characterization of a HgCdTe Near Infrared Detector with a Pronounced Crosshatch Pattern

The “crosshatch” pattern is a recurring “feature” of HgCdTe arrays, specifically the Teledyne HAWAII family of near infrared detectors. It is a fixed pattern of high frequency QE variations along 3 directions generally thought to be related to the crystal structure of HgCdTe. The pattern is evident in detectors used in WFC3/IR, WISE, JWST, and in candidate detectors for Euclid and WFIRST. Using undersampled point sources projected onto a HAWAII-2RG detector, we show that the pattern induces photometric variations that are not removed by a flat-field calibration, thus demonstrating that the QE variations occur on scales smaller than the 18 micron pixels. Our testbed is the Precision Projector Laboratory’s astronomical scene generator, which can rapidly characterize the full detector by scanning thousands of undersampled spots. If not properly calibrated, detectors showing strong crosshatch may induce correlated errors in photometry, astrometry, spectroscopy, and shape measurements.

Smith, Roger↗

Astrometric Calibration of Array Detectors

The high level of spatial uniformity in modern CCDs and other array detectors makes them excellent devices for astrometric and navigational systems. However, at the level of accuracy envisioned by the more ambitious projects, current technology produces devices with significant pixel registration errors. This paper describes a technique fot measuring relative pixel positions to an accuracy approaching 0.001 pixel. The technique has been applied to WF/PC II CCDs whicha re shown to have 500 nm step-and-repeat errors.

array detectors CCDs navigational systems astromet↗

Accuracy of measurement of star images on a pixel array

Algorithms are developed for predicting the accuracy with which the brightness of a star can be determined from its image on a digital detector array, as a function of the brightness of the background. The assumption is made that a known profile is being fitted by least squares. The two profiles used correspond to ST images and to ground-based observations. The first result is an approximate rule of thumb for equivalent noise area. More rigorous results are then given in tabular form. The size of the pixels, relative to the image size, is taken into account. Astronometric accuracy is also discussed briefly; the error, relative to image size, is very similar to the photometric error relative to brightness.

King, I. R.↗

Design and Bolometer Characterization of the SPT-3G First-Year Focal Plane

During the austral summer of 2016-2017, the third-generation camera, SPT-3G, was installed on the South Pole Telescope, increasing the detector count in the focal plane by an order of magnitude relative to the previous generation. Designed to map the polarization of the cosmic microwave background, SPT-3G contains ten 6 ''-hexagonal modules of detectors, each with 269 trichroic and dual-polarization pixels, read out using 68x frequency-domain multiplexing. Here we discuss design, assembly, and layout of the modules, as well as early performance characterization of the first-year array, including yield and detector properties.

bolometer↗

Probabilistic Processing of Asynchronous Geiger-Mode Avalanche Photodiode Arrays for Background Rate Measurements

A system-level performance evaluation of Geiger-mode avalanche photodiode (GmAPD) arrays requires accurate measurement and prediction of the background rate of the device due to dark counts and other spurious detection events. Since a GmAPD detector reports only a binary value and timestamp associated with an avalanche event, dark count rates are typically measured by averaging thousands of frames to support a statistically significant measurement. For both synchronous and asynchronous detector, the Poisson distributed background rates are referenced to the time each pixel is armed. Unlike for synchronous GmAPD imagers where all the pixels are armed to an array-wide arm signal, an asynchronous pixel operates independently from its neighboring pixels; requiring the background rates to be calculated using an interarrival histogram. For both types of imagers, the background rate is typically evaluated by fitting an exponential distribution to a fixed window within a measured histogram of time intervals between detection events However, if the statistics of the background rate are insufficient – whether that is due to low population sizes, saturation, or a large dynamic range of population size across the array, the pixel, or array-wide, performance metrics may report results with varying accuracy. This paper reports on an implementation of an algorithm that evaluates GmAPD background rates based on statistical metrics rather than fixed windows. The algorithm functions by determining the appropriate integration window within the interarrival time histogram based on a per-pixel count rate set by a predetermined tolerable measurement error. The implementation of the algorithm allows us to characterize GmAPD arrays with orders of magnitude spread in background rates across the detector using common statistical parameters.

Mumolo, J.↗

Design of an ultra low power CMOS pixel sensor for a future neutron personal dosimeter

Despite a continuously increasing demand, neutron electronic personal dosimeters (EPDs) are still far from being completely established because their development is a very difficult task. A low-noise, ultra low power consumption CMOS pixel sensor for a future neutron personal dosimeter has been implemented in a 0.35 {mu}m CMOS technology. The prototype is composed of a pixel array for detection of charged particles, and the readout electronics is integrated on the same substrate for signal processing. The excess electrons generated by an impinging particle are collected by the pixel array. The charge collection time and the efficiency are the crucial points of a CMOS detector. The 3-D device simulations using the commercially available Synopsys-SENTAURUS package address the detailed charge collection process. Within a time of 1.9 {mu}s, about 59% electrons created by the impact particle are collected in a cluster of 4 x 4 pixels with the pixel pitch of 80 {mu}m. A charge sensitive preamplifier (CSA) and a shaper are employed in the frond-end readout. The tests with electrical signals indicate that our prototype with a total active area of 2.56 x 2.56 mm{sup 2} performs an equivalent noise charge (ENC) of less than 400 e - and 314 {mu}W power consumption, leading to a promising prototype. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The LiteBIRD Satellite Mission: Sub-Kelvin Instrument

Inflation is the leading theory of the first instant of the universe. Inflation, which postulates that the universe underwent a period of rapid expansion an instant after its birth, provides convincing explanation for cosmological observations. Recent advancements in detector technology have opened opportunities to explore primordial gravitational waves generated by the inflation through “B-mode” (divergent-free) polarization pattern embedded in the cosmic microwave background anisotropies. If detected, these signals would provide strong evidence for inflation, point to the correct model for inflation, and open a window to physics at ultra-high energies. LiteBIRD is a satellite mission with a goal of detecting degree-and-larger-angular-scale B-mode polarization. LiteBIRD will observe at the second Lagrange point with a 400 mm diameter telescope and 2622 detectors. It will survey the entire sky with 15 frequency bands from 40 to 400 GHz to measure and subtract foregrounds. The US LiteBIRD team is proposing to deliver sub-Kelvin instruments that include detectors and readout electronics. A lenslet-coupled sinuous antenna array will cover low-frequency bands (40–235 GHz) with four frequency arrangements of trichroic pixels. An orthomode-transducer-coupled corrugated horn array will cover high-frequency bands (280–402 GHz) with three types of single frequency detectors. The detectors will be made with transition edge sensor (TES) bolometers cooled to a 100 milli-Kelvin base temperature by an adiabatic demagnetization refrigerator. The TES bolometers will be read out using digital frequency multiplexing with Superconducting QUantum Interference Device (SQUID) amplifiers. Up to 78 bolometers will be multiplexed with a single SQUID amplifier. Lastly, we report on the sub-Kelvin instrument design and ongoing developments for the LiteBIRD mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Status of the COBRA experiment

The current status of the COBRA experiment is described. Results on the 4-fold forbidden beta decay of {sup 113}Cd and a variety of double beta decay limits of Cd, Zn and Te isotopes are presented based on 18 kgxdays of exposure with an array of sixteen CdZnTe semiconductor detectors. A short description on the activities with pixelated detectors for tracking is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise figure of amplified dispersive Fourier transformation

Amplified dispersive Fourier transformation (ADFT) is a powerful tool for fast real-time spectroscopy as it overcomes the limitations of traditional optical spectrometers. ADFT maps the spectrum of an optical pulse into a temporal waveform using group-velocity dispersion and simultaneously amplifies it in the optical domain. It greatly simplifies spectroscopy by replacing the diffraction grating and detector array in the conventional spectrometer with a dispersive fiber and single-pixel photodetector, enabling ultrafast real-time spectroscopic measurements. Following our earlier work on the theory of ADFT, here we study the effect of noise on ADFT. We derive the noise figure of ADFT and discuss its dependence on various parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deuteron Evaporation from N = Z Compound Nuclei

Deuteron evaporation was observed from the N = Z compound nuclei 52 Fe ⋆ , 56 Ni ⋆ , and 64 Ge ⋆ in an experiment conducted at Argonne National Laboratory, USA. The experiment included a novel combination of two highly pixelated double-sided Si-strip detectors inside the Microball chargedparticle detection array, allowing for unequivocal discrimination of evaporated deuterons from protons and α particles. In conjunction with the Gammasphere array, Neutron Shell, and additional ancillary detectors, decay paths into various residual nuclei were investigated. The study provides insights into the competition of deuteron vs. proton-neutron evaporation as a function of available excitation energy and populated angular momentum. Results are interpreted using a statistical evaporation formalism for multiple subsequent particle emissions. The decisive factor in the comparison appears to be the available excitation energy in the residual system, with single nucleon evaporation preferred over deuteron evaporation for higher excitation energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Breadboard stellar tracker system test report, volume 1

The performance of a star tracker equipped with a focal plane detector was evaluated. The CID board is an array of 256 x 256 pixels which are 20 x 20 micrometers in dimension. The tracker used for test was a breadboard tracker system developed by BASD. Unique acquisition and tracking algorithms are employed to enhance performance. A pattern recognition process is used to test for proper image spread function and to avoid false acquisition on noise. A very linear, high gain, interpixel transfer function is derived for interpolating star position. The lens used in the tracker has an EFL of 100 mm. The tracker has an FOV of 2.93 degrees resulting in a pixel angular subtense of 41.253 arc sec in each axis. The test procedure used for the program presented a star to the tracker in a circular pattern of positions; the pattern was formed by projecting a simulated star through a rotatable deviation wedge. Further tests determined readout noise, Noise Equivalent Displacement during track, and spatial noise during acquisition by taking related data and reducing it.

Kollodge, J. C.↗

High-resolution pulse-counting array detectors for imaging and spectroscopy at ultraviolet wavelengths

The performance characteristics of multianode microchannel array (MAMA) detector systems which have formats as large as 256 x 1024 pixels and which have application to imaging and spectroscopy at UV wavelengths are evaluated. Sealed and open-structure MAMA detector tubes with opaque CsI photocathodes can determine the arrival time of the detected photon to an accuracy of 100 ns or better. Very large format MAMA detectors with CsI and Cs2Te photocathodes and active areas of 52 x 52 mm (2048 x 2048 pixels) will be used as the UV solar blind detectors for the NASA STIS.

Timothy, J. Gethyn↗