Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel array detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Shortwave Spectrometer (SWS) zenith radiance swsrad.b1 v3 and higher

Hyperspectral zenith radiances from the SWS instrument reported at 1 Hz. This data stream contains calibrated, dark-subtracted, radiances from two grating array spectrometers: a Si-detector based spectrometer denoted by SW and an InGaAs based detector denoted by LW. Spectra from both spectrometers are calibrated based on the spectral responsivity determined by reference against NIST-traceable light sources are reported independently as separate arrays having the same time record but wavelength dimension specified for each detector. Because the LW spectrometer is more susceptible to temperature-induced changes, a scale factor adjustment is applied the the LW spectra to yield agreement with the SW spectra over the wavelength range where they overlap. The final radiances incorporate QC to flag saturated values, periods where house-keeping fields fall outside acceptable bounds, and to flag pixels for which the spectral responsivity is not acceptable.

54 ENVIRONMENTAL SCIENCES↗

Giga-z: A 100,000 OBJECT SUPERCONDUCTING SPECTROPHOTOMETER FOR LSST FOLLOW-UP

We simulate the performance of a new type of instrument, a Superconducting Multi-Object Spectrograph (SuperMOS), that uses microwave kinetic inductance detectors (MKIDs). MKIDs, a new detector technology, feature good quantum efficiency in the UVOIR, can count individual photons with microsecond timing accuracy, and, like X-ray calorimeters, determine their energy to several percent. The performance of Giga-z, a SuperMOS designed for wide field imaging follow-up observations, is evaluated using simulated observations of the COSMOS mock catalog with an array of 100,000 R{sub 423{sub nm}} = E/{Delta}E = 30 MKID pixels. We compare our results against a simultaneous simulation of LSST observations. In 3 yr on a dedicated 4 m class telescope, Giga-z could observe Almost-Equal-To 2 billion galaxies, yielding a low-resolution spectral energy distribution spanning 350-1350 nm for each; 1000 times the number measured with any currently proposed LSST spectroscopic follow-up, at a fraction of the cost and time. Giga-z would provide redshifts for galaxies up to z Almost-Equal-To 6 with magnitudes m{sub i} {approx}< 25, with accuracy {sigma}{sub {Delta}z/(1+z)} Almost-Equal-To 0.03 for the whole sample, and {sigma}{sub {Delta}z/(1+z)} Almost-Equal-To 0.007 for a select subset. We also find catastrophic failure rates and biases that are consistently lower than for LSST. The added constraint on dark energy parameters for WL + CMB by Giga-z using the FoMSWG default model is equivalent to multiplying the LSST Fisher matrix by a factor of {alpha} = 1.27 (w{sub p} ), 1.53 (w{sub a} ), or 1.98 ({Delta}{gamma}). This is equivalent to multiplying both the LSST coverage area and the training sets by {alpha} and reducing all systematics by a factor of 1/{radical}({alpha}), advantages that are robust to even more extreme models of intrinsic alignment.

79 ASTRONOMY AND ASTROPHYSICS↗

Brighter-fatter Effect in Near-infrared Detectors—III. Fourier-domain Treatment of Flat Field Correlations and Application to WFIRST

Weak gravitational lensing has emerged as a leading probe of the growth of cosmic structure. However, the shear signal is very small and accurate measurement depends critically on our ability to understand how non-ideal instrumental effects affect astronomical images. The Wide-Field Infrared Survey Telescope (WFIRST) will fly a focal plane containing 18 Teledyne H4RG-10 near-infrared detector arrays, which present different instrument calibration challenges from previous weak lensing observations. Previous work [Paper I: Hirata & Choi, PASP, 132, 014501 (2020); and Paper II: Choi & Hirata, PASP, 132, 014502 (2020)] has shown that correlation functions of flat field images, including cross-correlations between different time slices that are enabled by the non-destructive read capability of the infrared detectors, are effective tools for disentangling linear and nonlinear inter-pixel capacitance (IPC) and the brighter-fatter effect (BFE). Here we present a Fourier-domain treatment of the flat field correlations, which allows us to expand the previous formalism to all orders in IPC, BFE, and classical nonlinearity. We show that biases in simulated flat field analyses in Paper I are greatly reduced through the use of this formalism. We then apply this updated formalism to flat field data from three WFIRST flight candidate detectors, and explore the robustness to variations in the analysis. We find that the BFE is present in all three detectors, and that its contribution to the flat field correlations dominates over the nonlinear IPC, in accordance with the results from Paper II on a development detector. The magnitude of the BFE is such that the effective area of a pixel is increased by (3.54 ± 0.03) × 10 -7 for every electron deposited in a neighboring pixel (sensor chip assembly [SCA] 20829, statistical error, not IPC-deconvolved). We compare IPC maps from flat field autocorrelation measurements to those obtained from the single pixel reset method and find a median difference of 0.113% for SCA 20829. After further diagnosis of this difference, we ascribe it largely to an additional source of cross-talk, the vertical trailing pixel effect, and recommend further work to develop a model for this effect. These results represent a significant step toward calibration of the non-ideal effects in WFIRST detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Shifting scintillator neutron detector

Provided are sensors and methods for detecting thermal neutrons. Provided is an apparatus having a scintillator for absorbing a neutron, the scintillator having a back side for discharging a scintillation light of a first wavelength in response to the absorbed neutron, an array of wavelength-shifting fibers proximate to the back side of the scintillator for shifting the scintillation light of the first wavelength to light of a second wavelength, the wavelength-shifting fibers being disposed in a two-dimensional pattern and defining a plurality of scattering plane pixels where the wavelength-shifting fibers overlap, a plurality of photomultiplier tubes, in coded optical communication with the wavelength-shifting fibers, for converting the light of the second wavelength to an electronic signal, and a processor for processing the electronic signal to identify one of the plurality of scattering plane pixels as indicative of a position within the scintillator where the neutron was absorbed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard X-ray Fluorescence measurements with TESs at the Advanced Photon Source

Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20keV energy range. We are building a TES-based instrument for time Advanced Photon Source (APS) synchrotron, to be made available to beamline users. 24-pixel prototype arrays have recently been fabricated and tested. the first, spectroscopy measurements using these arrays are promising, with a best single-pixel energy resolution of 11.2 eV and saturation energy > 20 keV. We present a series of recent X-ray Fluorescence measurements involving transition metal elements and multi-element samples with closely spaced emission lines, in particular a Cu-Ni-Co thin film and a foil of Cu and Hf, The TES-measured spectra are directly compared to spectra measured with silicon drift detectors at an APS beamline, demonstrating the improved X-ray science made possible by TES spectrometers.

Guruswamy, Tejas↗

Time characteristics of detectors based on silicon photomultipliers for the GlueX experiment

Here, silicon photomultipliers (SiPMs) are used in detectors of the GlueX experiment devoted to studying the nature of confinement. These detectors are operable at counting rates as high as 2 MHz with a time resolution (FWHM) of approximately 0.3 ns and a number of excited pixels of up to 10 4 . For SiPMs that operate under these conditions, the measured dependences of the recovery time and the time resolution are presented as functions of the number of excited pixels and the excitation frequency. Using a picosecond laser, the time resolution has been measured for an array of 4 × 4 SiPMs, which was specially developed for the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Efficiency CdZnTe Position-Sensitive VFG Gamma-Ray Detectors for Safeguards Applications

The goal of this project is to incorporate a Cadmium-Zinc-Telluride (CdZnTe or CZT) detector (with 1% or better resolution) into a bench-top prototype for isotope identification and related safeguards applications. The bench-top system is based on a 2x2 array of 6x6x20 mm 3 position-sensitive virtual Frisch-grid (VFG) CZT detectors. The key features of the array are that it allows for the use of average-grade CZT material with a moderate content of defects, and yet it provides high energy resolution, 1% FWHM at 662 keV, large effective area, and low-power consumption. The development of this type of 3D detector and new instruments incorporating them is motivated by the high cost and low availability of large, > 1 cm 3 , CZT crystals suitable for making multi-pixel detectors with acceptable energy resolution and efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixel detectors in 3D technologies for high energy physics

This paper reports on the current status of the development of International Linear Collider vertex detector pixel readout chips based on multi-tier vertically integrated electronics. Initial testing results of the VIP2a prototype are presented. The chip is the second embodiment of the prototype data-pushed readout concept developed at Fermilab. The device was fabricated in the MIT-LL 0.15 {micro}m fully depleted SOI process. The prototype is a three-tier design, featuring 30 x 30 {micro}m{sup 2} pixels, laid out in an array of 48 x 48 pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of S12045(X) photon sensors for GlueX

The barrel calorimeter of the GlueX detector in Hall D at Jefferson Lab will be instrumented with 4000 large-area (1.2×1.2 cm2) silicon photomultipliers (SiPMs) [1]. These photon sensors have properties similar to vacuum photomultipliers, but are unaffected by high magnetic fields. In our experiment, they will operate in magnetic fields exceeding 1\,T. After extensive tests with a variety of sensors, we chose the S12045(X) custom SiPM arrays manufactured by Hamamatsu Corporation, also known as multi-pixel photon counters (MPPCs) [2]. All production units have been delivered and we have measured the photon detection efficiency (PDE), gain, dark rate, cross talk and after pulsing at three different temperatures (5, 7 and {20?C}). We will present a summary of these measurements and the plan for use of these sensors in the GlueX experiment.\\[4pt] [1] F. Barbosa {\em et al.,} NIM A695 (2012) 100.\\[0pt] [2] Y. Qiang {\em et al.,} NIM A698 (2013) 234.

Smith, E.S.↗

Toward Scintillator High‐Gain Avalanche Rushing Photoconductor Active Matrix Flat Panel Imager ( SHARP ‐ AMFPI ): Initial fabrication and characterization

Purpose We present the first prototype Scintillator High‐Gain Avalanche Rushing Photoconductor Active Matrix Flat Panel Imager ( SHARP ‐ AMFPI ). This detector includes a layer of avalanche amorphous Selenium (a‐Se) ( HARP ) as the photoconductor in an indirect detector to amplify the signal and reduce the effects of electronic noise to obtain quantum noise‐limited images for low‐dose applications. It is the first time avalanche a‐Se has been used in a solid‐state imaging device and poses as a possible solution to eliminate the effects of electronic noise, which is crucial for low‐dose imaging performance of AMFPI . Methods We successfully deposited a solid‐state HARP structure onto a 24 × 30 cm 2 array of thin‐film transistors ( TFT array) with a pixel pitch of 85 μm. The HARP layer consists of 16 μm of a‐Se with a hole‐blocking and electron‐blocking layer to prevent charge injection from the high‐voltage bias and pixel electrodes, respectively. An electric field ( E S e ) up to 105 V μm −1 was applied across the a‐Se layer without breakdown. A 150 μm thick‐structured CsI:Tl scintillator was used to form SHARP ‐ AMFPI . The x‐ray imaging performance is characterized using a 30 kV p Mo/Mo beam. We evaluate the spatial resolution, noise power, and detective quantum efficiency at zero frequency of the system with and without avalanche gain. The results are analyzed using cascaded linear system model ( CLSM ). Results An avalanche gain of 76 ± 5 was measured at E S e = 105 V μm −1 . We demonstrate that avalanche gain can amplify the signal to overcome electronic noise. As avalanche gain is increased, image quality improves for a constant (0.76 mR ) exposure until electronic noise is overcome. Our system is currently limited by poor optical transparency of our high‐voltage electrode and long integrating time which results in dark current noise. These two effects cause high‐spatial frequency noise to dominate imaging performance. Conclusions We demonstrate the feasibility of a solid‐state HARP x‐ray imager and have fabricated the largest active area HARP sensor to date. Procedures to reduce secondary quantum and dark noise are outlined. Future work will improve optical coupling and charge transport which will allow for frequency DQE and temporal metrics to be obtained.

Scheuermann, James R.↗

A Low Power, High Speed Readout for Pixel Detectors Based on an Arbitration Tree

A low-power, high-speed arbitration tree for pixel detector readout is presented. The synchronized, binary tree priority encoder establishes a position dependent priority list at the start of every time frame. Pixels that indicate the presence of data for readout, are sequentially granted access to a shared bus for data transfer to the periphery, without the use of an additional global strobe signal. It can be used for either full frame imaging or zero-suppressed readout, in which case it can simultaneously generate the pixel address. To increase the readout frame rate, the pixel array is subdivided into two halves, which allows interleaved latching of data at the output serializer. The design was implemented in a 65 nm LP-CMOS process for the readout of a 64 x 64 pixel array. Measurement results demonstrate a deadtime-less, full frame imaging rate of ~50 kfps, achieved with a dedicated output for every (32 x 32) 1024 pixels and for a pixel data packet of 11 bits, with no bit errors detected over 1000 frames. The measured energy per bit is 0.94 pJ.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vertically integrated pixel readout chip for high energy physics

We report on the development of the vertex detector pixel readout chips based on multi-tier vertically integrated electronics for the International Linear Collider. Some testing results of the VIP2a prototype are presented. The chip is the second iteration of the silicon implementation of the prototype, data-pushed concept of the readout developed at Fermilab. The device was fabricated in the 3D MIT-LL 0.15 {micro}m fully depleted SOI process. The prototype is a three-tier design, featuring 30 x 30 {micro}m{sup 2} pixels, laid out in an array of 48 x 48 pixels.

99 GENERAL AND MISCELLANEOUS↗

SU-E-J-46: Development of a Compton Camera Prototype for Online Range Verification of Laser-Accelerated Proton Beams

Purpose: Development of a photon detection system designed for online range verification of laser-accelerated proton beams via prompt-gamma imaging of nuclear reactions. Methods: We develop a Compton camera for the position-sensitive detection of prompt photons emitted from nuclear reactions between the proton beam and biological samples. The detector is designed to be capable to reconstruct the photon source origin not only from the Compton scattering kinematics of the primary photon, but also to allow for tracking of the Compton-scattered electrons. Results: Simulation studies resulted in the design of the Compton camera based on a LaBr{sub 3}(Ce) scintillation crystal acting as absorber, preceded by a stacked array of 6 double-sided silicon strip detectors as scatterers. From the design simulations, an angular resolution of ≤ 2° and an image reconstruction efficiency of 10{sup −3} −10{sup −5} (at 2–6 MeV) can be expected. The LaBr{sub 3} crystal has been characterized with calibration sources, resulting in a time resolution of 273 ps (FWHM) and an energy resolution of about 3.8% (FWHM). Using a collimated (1 mm diameter) {sup 137}Cs calibration source, the light distribution was measured for each of 64 pixels (6×6 mm{sup 2}). Data were also taken with 0.5 mm collimation and 0.5 mm step size to generate a reference library of light distributions that allows for reconstructing the interaction position of the initial photon using a k-nearest neighbor (k-NN) algorithm developed by the Delft group. Conclusion: The Compton-camera approach for prompt-gamma detection offers promising perspectives for ion beam range verification. A Compton camera prototype is presently being developed and characterized in Garching. Furthermore, an arrangement of, e.g., 4 camera modules could even be used in a ‘gamma-PET’ mode to detect delayed annihilation radiation from positron emitters in the irradiation interrupts (with improved performance in the presence of an additional third (prompt) photon (as in 10C and 14O). This work was supported by the DFG Cluster of Excellence MAP (Munich-Centre for Advanced Photonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BICEP2. II. Experiment and three-year data set

We report on the design and performance of the BICEP2 instrument and on its three-year data set. BICEP2 was designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 1°-5°(ℓ = 40-200), near the expected peak of the B-mode polarization signature of primordial gravitational waves from cosmic inflation. Measuring B-modes requires dramatic improvements in sensitivity combined with exquisite control of systematics. The BICEP2 telescope observed from the South Pole with a 26 cm aperture and cold, on-axis, refractive optics. BICEP2 also adopted a new detector design in which beam-defining slot antenna arrays couple to transition-edge sensor (TES) bolometers, all fabricated on a common substrate. The antenna-coupled TES detectors supported scalable fabrication and multiplexed readout that allowed BICEP2 to achieve a high detector count of 500 bolometers at 150 GHz, giving unprecedented sensitivity to B-modes at degree angular scales. After optimization of detector and readout parameters, BICEP2 achieved an instrument noise-equivalent temperature of 15.8 μK√s. The full data set reached Stokes Q and U map depths of 87.2 nK in square-degree pixels (5.'2 μK) over an effective area of 384 deg{sup 2} within a 1000 deg{sup 2} field. These are the deepest CMB polarization maps at degree angular scales to date. The power spectrum analysis presented in a companion paper has resulted in a significant detection of B-mode polarization at degree scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Patient-Specific 3D Pretreatment and Potential 3D Online Dose Verification of Monte Carlo-Calculated IMRT Prostate Treatment Plans

Purpose: Fast and reliable comprehensive quality assurance tools are required to validate the safety and accuracy of complex intensity-modulated radiotherapy (IMRT) plans for prostate treatment. In this study, we evaluated the performance of the COMPASS system for both off-line and potential online procedures for the verification of IMRT treatment plans. Methods and Materials: COMPASS has a dedicated beam model and dose engine, it can reconstruct three-dimensional dose distributions on the patient anatomy based on measured fluences using either the MatriXX two-dimensional (2D) array (offline) or a 2D transmission detector (T2D) (online). For benchmarking the COMPASS dose calculation, various dose-volume indices were compared against Monte Carlo-calculated dose distributions for five prostate patient treatment plans. Gamma index evaluation and absolute point dose measurements were also performed in an inhomogeneous pelvis phantom using extended dose range films and ion chamber for five additional treatment plans. Results: MatriXX-based dose reconstruction showed excellent agreement with the ion chamber (<0.5%, except for one treatment plan, which showed 1.5%), film ({approx}100% pixels passing gamma criteria 3%/3 mm) and mean dose-volume indices (<2%). The T2D based dose reconstruction showed good agreement as well with ion chamber (<2%), film ({approx}99% pixels passing gamma criteria 3%/3 mm), and mean dose-volume indices (<5.5%). Conclusion: The COMPASS system qualifies for routine prostate IMRT pretreatment verification with the MatriXX detector and has the potential for on-line verification of treatment delivery using T2D.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and performance of the first IceAct demonstrator at the South Pole

Here in this paper we describe the first results of IceAct, a compact imaging air-Cherenkov telescope operating in coincidence with the IceCube Neutrino Observatory (IceCube) at the geographic South Pole. An array of IceAct telescopes (referred to as the IceAct project) is under consideration as part of the IceCube-Gen2 extension to IceCube. Surface detectors in general will be a powerful tool in IceCube-Gen2 for distinguishing astrophysical neutrinos from the dominant backgrounds of cosmic-ray induced atmospheric muons and neutrinos: the IceTop array is already in place as part of IceCube, but has a high energy threshold. Although the duty cycle will be lower for the IceAct telescopes than the present IceTop tanks, the IceAct telescopes may prove to be more effective at lowering the detection threshold for air showers. Additionally, small imaging air-Cherenkov telescopes in combination with IceTop, the deep IceCube detector or other future detector systems might improve measurements of the composition of the cosmic ray energy spectrum. In this paper we present measurements of a first 7-pixel imaging air Cherenkov telescope demonstrator, proving the capability of this technology to measure air showers at the South Pole in coincidence with IceTop and the deep IceCube detector.

47 OTHER INSTRUMENTATION↗

Toward optimizing patient-specific IMRT QA techniques in the accurate detection of dosimetrically acceptable and unacceptable patient plans

Purpose: The authors investigated the performance of several patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA) dosimeters in terms of their ability to correctly identify dosimetrically acceptable and unacceptable IMRT patient plans, as determined by an in-house-designed multiple ion chamber phantom used as the gold standard. A further goal was to examine optimal threshold criteria that were consistent and based on the same criteria among the various dosimeters. Methods: The authors used receiver operating characteristic (ROC) curves to determine the sensitivity and specificity of (1) a 2D diode array undergoing anterior irradiation with field-by-field evaluation, (2) a 2D diode array undergoing anterior irradiation with composite evaluation, (3) a 2D diode array using planned irradiation angles with composite evaluation, (4) a helical diode array, (5) radiographic film, and (6) an ion chamber. This was done with a variety of evaluation criteria for a set of 15 dosimetrically unacceptable and 9 acceptable clinical IMRT patient plans, where acceptability was defined on the basis of multiple ion chamber measurements using independent ion chambers and a phantom. The area under the curve (AUC) on the ROC curves was used to compare dosimeter performance across all thresholds. Optimal threshold values were obtained from the ROC curves while incorporating considerations for cost and prevalence of unacceptable plans. Results: Using common clinical acceptance thresholds, most devices performed very poorly in terms of identifying unacceptable plans. Grouping the detector performance based on AUC showed two significantly different groups. The ion chamber, radiographic film, helical diode array, and anterior-delivered composite 2D diode array were in the better-performing group, whereas the anterior-delivered field-by-field and planned gantry angle delivery using the 2D diode array performed less well. Additionally, based on the AUCs, there was no significant difference in the performance of any device between gamma criteria of 2%/2 mm, 3%/3 mm, and 5%/3 mm. Finally, optimal cutoffs (e.g., percent of pixels passing gamma) were determined for each device and while clinical practice commonly uses a threshold of 90% of pixels passing for most cases, these results showed variability in the optimal cutoff among devices. Conclusions: IMRT QA devices have differences in their ability to accurately detect dosimetrically acceptable and unacceptable plans. Field-by-field analysis with a MapCheck device and use of the MapCheck with a MapPhan phantom while delivering at planned rotational gantry angles resulted in a significantly poorer ability to accurately sort acceptable and unacceptable plans compared with the other techniques examined. Patient-specific IMRT QA techniques in general should be thoroughly evaluated for their ability to correctly differentiate acceptable and unacceptable plans. Additionally, optimal agreement thresholds should be identified and used as common clinical thresholds typically worked very poorly to identify unacceptable plans.

60 APPLIED LIFE SCIENCES↗

Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors

We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allow the location of the interaction to be determined with < or approx. 1mm resolution at 30 keV. Using this position information, variations in the detector response with position can be removed, and an energy resolution of {sigma}{sub E} = 0.55 keV at 30 keV was measured. Since MKIDs can be fabricated from a single deposited film and are naturally multiplexed in the frequency domain, this technology can be extended to provide highly pixelized athermal phonon sensors for {approx}1 kg scale detector elements. Such high-resolution, massive particle detectors would be applicable to rare-event searches such as the direct detection of dark matter, neutrinoless double-beta decay, or coherent neutrino-nucleus scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗