Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Brighter-fatter Effect in Near-infrared Detectors—III. Fourier-domain Treatment of Flat Field Correlations and Application to WFIRST

Weak gravitational lensing has emerged as a leading probe of the growth of cosmic structure. However, the shear signal is very small and accurate measurement depends critically on our ability to understand how non-ideal instrumental effects affect astronomical images. The Wide-Field Infrared Survey Telescope (WFIRST) will fly a focal plane containing 18 Teledyne H4RG-10 near-infrared detector arrays, which present different instrument calibration challenges from previous weak lensing observations. Previous work [Paper I: Hirata & Choi, PASP, 132, 014501 (2020); and Paper II: Choi & Hirata, PASP, 132, 014502 (2020)] has shown that correlation functions of flat field images, including cross-correlations between different time slices that are enabled by the non-destructive read capability of the infrared detectors, are effective tools for disentangling linear and nonlinear inter-pixel capacitance (IPC) and the brighter-fatter effect (BFE). Here we present a Fourier-domain treatment of the flat field correlations, which allows us to expand the previous formalism to all orders in IPC, BFE, and classical nonlinearity. We show that biases in simulated flat field analyses in Paper I are greatly reduced through the use of this formalism. We then apply this updated formalism to flat field data from three WFIRST flight candidate detectors, and explore the robustness to variations in the analysis. We find that the BFE is present in all three detectors, and that its contribution to the flat field correlations dominates over the nonlinear IPC, in accordance with the results from Paper II on a development detector. The magnitude of the BFE is such that the effective area of a pixel is increased by (3.54 ± 0.03) × 10 -7 for every electron deposited in a neighboring pixel (sensor chip assembly [SCA] 20829, statistical error, not IPC-deconvolved). We compare IPC maps from flat field autocorrelation measurements to those obtained from the single pixel reset method and find a median difference of 0.113% for SCA 20829. After further diagnosis of this difference, we ascribe it largely to an additional source of cross-talk, the vertical trailing pixel effect, and recommend further work to develop a model for this effect. These results represent a significant step toward calibration of the non-ideal effects in WFIRST detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Prompt and delayed spectroscopy of {sup 199}At

The neutron-deficient nucleus {sup 199}At has been studied through {gamma}-ray and electron spectroscopy, using the recoil-decay tagging technique. Two experiments were conducted, using a gas-filled recoil separator with a focal-plane spectrometer alone and together with a germanium-detector array at the target position. The resulting level scheme for {sup 199}At includes a new isomer with a half-life of 0.80(5) {mu}s and a spin and parity of (29/2{sup +}). The 13/2{sup +} isomer, which de-excites via an M2 transition to the 9/2{sup -} ground state, was measured to have a half-life of 70(20) ns. Our earlier version of the level scheme for {sup 197}At has been updated as well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pattern formation during healing of fluid-filled cracks: an analog experiment

The formation and subsequent healing of cracks and crack networks may control such diverse phenomena as the strengthening of fault zones between earthquakes, fluid migrations in the Earth's crust, or the transport of radioactive materials in nuclear waste disposal. An intriguing pattern-forming process can develop during healing of fluid-filled cracks, where pockets of fluid remain permanently trapped in the solid as the crack tip is displaced driven by surface energy. Here, we present the results of analog experiments in which a liquid was injected into a colloidal inorganic gel to obtain penny-shaped cracks that were subsequently allowed to close and heal under the driving effect of interfacial tension. Depending on the properties of the gel and the injected liquid, two modes of healing were obtained. In the first mode, the crack healed completely through a continuous process. The second mode of healing was discontinuous and was characterized by a 'zipper-like' closure of a front that moved along the crack perimeter, trapping fluid that may eventually form inclusions trapped in the solid. This instability occurred only when the velocity of the crack tip decreased to zero. Our experiments provide a cheap and simple analog to reveal how aligned arrays of fluid inclusions may be captured along preexisting fracture planes and how small amounts of fluids can be permanently trapped in solids, modifying irreversibly their material properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-417: Experimental Verification of Robustness Optimized Intensity Modulated Proton Therapy Plans for Craniospinal Irradiation

Purpose: The robustness-optimized intensity modulated proton therapy (RO-IMPT) plans takes into account the setup errors to eliminate the hot/cold spots caused by setup errors at the junction for craniospinal (CSI) irradiation fields. The RO-IMPT requires a large area for the junction of two fields. This work is to verify the treatment planning system calculated dose with introduction of setup errors by two-dimensional (2D) dose measurement. Two fields of total lengths of 45 cm with junctions of 21 cm were measured. Methods: 2D dose distributions in the coronal plane were measured by a commercial 2D ion-chamber-array detector in a cubic solid water phantom. A total spine field consisting of an upper and a lower spine field was measured at the depths of 5.4 and 6.9 cm. The active area for the measurement was 24×24 cm{sup 2}2. The junction and the area outside the junction of the spine fields were measured separately to complete the verification for the total field. Six different amounts of set-up errors along the superior-inferior direction up to 1.4 cm were intentionally applied. The measured dose with and without set-up errors were compared with the calculated dose with and without set-up errors using Gamma-index analysis. 3%/3mm and 2%/2mm dose/distance agreement criteria were used. The point dose at the center of the junction was also compared. Results: For all fields with various introduced setup errors, 100 % of pixels passed the 3%/3mm criteria and on average 96% of pixels passed 2%/2mm criteria. Differences in the measured and calculated doses were within 1.1%. Conclusion: The efficacy of the robustness for the CSI RO-IMPT plans were verified by measurement. The measurement method can be used for patient treatment field specific QA for CSI RO-IMPT plans in our institution in the near future.

60 APPLIED LIFE SCIENCES↗

Nanophotonic production, modulation and switching of ions by silicon microcolumn arrays

The production and use of silicon microcolumn arrays that harvest light from a laser pulse to produce ions are described. The systems of the present invention seem to behave like a quasi-periodic antenna array with ion yields that show profound dependence on the plane of laser light polarization and the angle of incidence. By providing photonic ion sources, this enables enhanced control of ion production on a micro/nano scale and direct integration with miniaturized analytical devices.

47 OTHER INSTRUMENTATION↗

Nanophotonic production, modulation and switching of ions by silicon microcolumn arrays

The production and use of silicon microcolumn arrays that harvest light from a laser pulse to produce ions are described. The systems of the present invention seem to behave like a quasi-periodic antenna array with ion yields that show profound dependence on the plane of laser light polarization and the angle of incidence. By providing photonic ion sources, this enables enhanced control of ion production on a micro/nano scale and direct integration with miniaturized analytical devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Nanophotonic production, modulation and switching of ions by silicon microcolumn arrays

The production and use of silicon microcolumn arrays that harvest light from a laser pulse to produce ions are described. The systems of the present invention seem to behave like a quasi-periodic antenna array with ion yields that show profound dependence on the plane of laser light polarization and the angle of incidence. By providing photonic ion sources, this enables enhanced control of ion production on a micro/nano scale and direct integration with miniaturized analytical devices.

36 MATERIALS SCIENCE↗

Optical design concept of the CMB-S4 large-aperture telescopes and cameras

CMB-S4 -- the next-generation ground-based cosmic microwave background (CMB) experiment - will significantly advance the sensitivity of CMB measurements and improve our understanding of the origin and evolution of the universe. CMB-S4 will deploy large-aperture telescopes fielding hundreds of thousands of detectors at millimeter wavelengths. We present the baseline optical design concept of the large-aperture CMB-S4 telescopes, which consists of two optical configurations: (i) a new off-axis, three-mirror, free-form anastigmatic design and (ii) the existing coma-corrected crossed-Dragone design. We also present an overview of the optical configuration of the array of silicon optics cameras that will populate the focal plane with 85 diffraction-limited optics tubes covering up to 9 degrees of field of view, up to $1.1 \, \rm mm$ in wavelength. We describe the computational optimization methods that were put in place to implement the families of designs described here and give a brief update on the current status of the design effort.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy

Purpose: The objective of this work is to present a new 2D plastic scintillation detectors array (2D-PSDA) designed for the dosimetry of megavoltage (MV) energy photon beams in radiation therapy and to characterize its basic performance. Methods: We developed a 2D detector array consisting of 781 plastic scintillation detectors (PSDs) inserted into a plane of a water-equivalent phantom. The PSDs were distributed on a 26 x 26 cm{sup 2} grid, with an interdetector spacing of 10 mm, except for two perpendicular lines centered on the detection plane, where the spacing was 5 mm. Each PSD was made of a 1 mm diameter by 3 mm long cylindrical polystyrene scintillating fiber coupled to a clear nonscintillating plastic optical fiber. All of the light signals emitted by the PSDs were read simultaneously with an optical system at a rate of one measurement per second. We characterized the performance of the optical system, the angular dependency of the device, and the perturbation of dose distributions caused by the hundreds of PSDs inserted into the phantom. We also evaluated the capacity of the system to monitor complex multileaf collimator (MLC) sequences such as those encountered in step-and-shoot intensity modulated radiation therapy (IMRT) plans. We compared our results with calculations performed by a treatment planning system and with measurements taken with a 2D ionization chamber array and with a radiochromic film. Results: The detector array that we developed allowed us to measure doses with an average precision of better than 1% for cumulated doses equal to or greater than 6.3 cGy. Our results showed that the dose distributions produced by the 6-MV photon beam are not perturbed (within {+-}1.1%) by the presence of the hundreds of PSDs located into the phantom. The results also showed that the variations in the beam incidences have little effect on the dose response of the device. For all incidences tested, the passing rates of the gamma tests between the 2D-PSDA and the treatment planning system were higher than 97.5% when the standard clinical tolerances of 3% or 3 mm were used. Excellent agreement was obtained between the doses measured and calculated when we used the 2D-PSDA for monitoring a MLC sequence from a step-and-shoot IMRT plan. Conclusions: We demonstrated the feasibility of using a large number of PSDs in a new 2D-PSDA for the dosimetry of MV energy photon beams in radiation therapy. The excellent precision, accuracy, and low angular dependence of the device indicate that such a prototype could potentially be used as a high-accuracy quality assurance tool for IMRT and arc therapy patient plan verification. The homogeneity and water-equivalence of the prototype we built suggest that this technology could be extended to multiple detection planes by arranging the fibers into more complex orientations, opening the possibility for 3D dosimetry with PSDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Distribution of Ultrahigh-energy Cosmic Rays along the Supergalactic Plane Measured at the Pierre Auger Observatory

Ultrahigh-energy cosmic rays are known to be mainly of extragalactic origin, and their propagation is limited by energy losses, so their arrival directions are expected to correlate with the large-scale structure of the local Universe. In this work, we investigate the possible presence of intermediate-scale excesses in the flux of the most energetic cosmic rays from the direction of the supergalactic plane region using events with energies above 20 EeV recorded with the surface detector array of the Pierre Auger Observatory up to 2022 December 31, with a total exposure of 135,000 km 2 sr yr. The strongest indication for an excess that we find, with a posttrial significance of 3.1σ, is in the Centaurus region, as in our previous reports, and it extends down to lower energies than previously studied. We do not find any strong hints of excesses from any other region of the supergalactic plane at the same angular scale. In particular, our results do not confirm the reports by the Telescope Array Collaboration of excesses from two regions in the Northern Hemisphere at the edge of the field of view of the Pierre Auger Observatory. With a comparable integrated exposure over these regions, our results there are in good agreement with the expectations from an isotropic distribution.

Abdul Halim, A. [Univ. of Adelaide, SA (Australia)↗

ESnet/JLab FPGA Accelerated Transport

To increase the science rate for high data rates/volumes, Thomas Jefferson National Accelerator Facility (JLab) has partnered with Energy Sciences Network (ESnet) to define an edge to data center traffic shaping / steering transport capability featuring data event aware network shaping and forwarding. The keystone of this ESnet+JLab FPGA Accelerated Transport (EJFAT) is the joint development of an AI/ML directed dynamic compute work Load Balancer (LB) of UDP streamed data. The LB is a suite consisting of a Field Programmable Gate Array (FPGA) executing the dynamically configurable, low fixed latency LB data plane featuring real-time packet redirection and high throughput, and a control plane running on the FPGA host computer that monitors network and compute farm telemetry in order to make dynamic AI/ML guided decisions for destination compute host redirection/load balancing and destination resource provisioning. The LB provides for three-tier horizontal scaling across LB suites, core compute hosts, and CPUs within a host. The LB effectively provides seamless integration of edge/core computing to support direct experimental data processing for immediate use by JLab science programs and others such as the EIC as well as data centers of the future requiring high throughput and low latency for both hot and cooled data for both running experiment data acquisition systems and data center use cases.

97 MATHEMATICS AND COMPUTING↗

Optimally placing photovoltaic arrays to maximize value of energy production based on peak power production, local solar radiation, weather, electricity market prices and rate structures

A method, system and computer program product for optimally placing photovoltaic arrays to maximize a value of energy production. Incident solar radiation for various placements of the photovoltaic arrays accommodating different azimuths and tilts is calculated. Alternating current solar photovoltaic electricity energy and power production is then estimated from the calculated solar radiation on a plane and weather data. Furthermore, a value of solar photovoltaic electricity energy and power produced by the photovoltaic arrays for the various placements is calculating using the estimated alternating current solar photovoltaic electricity production. A placement out of the various placements for the photovoltaic arrays is then selected corresponding to a highest value of the solar photovoltaic electricity produced by the photovoltaic arrays. In this manner, the appropriate placement for the photovoltaic arrays is determined that maximizes the value of energy production (where “value” may correspond to an economic value or a non-economic value).

Webber, Michael E.↗

Silicon-On-Sapphire Metasurfaces Generate Arrays of Dark and Bright Traps for Neutral Atoms

We demonstrated crystalline silicon-on-sapphire (c-SOS) metasurfaces that convert a Gaussian beam into arrays of complex optical traps, including arrays of optical bottle beams that trap atoms in dark regions interleaved with bright tweezer arrays. The high refractive index and indirect band gap of crystalline silicon make it possible to design high-resolution near-infrared (λ > 700 nm) metasurfaces that can be manufactured at scale using CMOS-compatible processes. Compared with active components like spatial light modulators (SLMs) that have become widely used to generate trap arrays, metasurfaces provide an indefinitely scalable number of pixels, enabling large arrays of complex traps in a very small form factor, as well as reduced dynamic noise. To design metasurfaces that can generate three-dimensional bottle beams to serve as dark traps, we modified the Gerchberg-Saxton algorithm to enforce complex-amplitude profiles at the focal plane of the metasurface and to optimize the uniformity of the traps across the array. We fabricated and measured c-SOS metasurfaces that convert a Gaussian laser beam into arrays of bright traps, dark traps, and interleaved bright/dark traps.

Gerchberg-Saxton↗

C-Cr segregation at grain boundary before the carbide nucleation in Alloy 690

The grain boundary segregation in Alloy 690 was investigated by atom probe tomography. B, C and Si segregated at the grain boundary. The high concentration regions for each segregation element form a set of straight arrays that are parallel to each other in the grain boundary plane. The concentration fluctuation has a periodicity of about 7 nm in the grain boundary plane. Before the Cr{sub 23}C{sub 6} nucleation at grain boundaries, the C-Cr co-segregate on one side of the grain boundaries while not the exact grain boundary core regions have been detected. The reasons why grain boundary carbides have coherent orientation relationship only with one side of nearby grain which grain boundary is located at high index crystal plane were discussed. - Highlights: Black-Right-Pointing-Pointer Grain boundary segregation in Alloy 690 was investigated by atom probe tomography. Black-Right-Pointing-Pointer B, C and Si segregate at the grain boundary. Black-Right-Pointing-Pointer Concentration of segregated atoms periodicity fluctuated in the grain boundary plane. Black-Right-Pointing-Pointer C and Cr co-segregate on one side of the grain boundary before carbide nucleation.

36 MATERIALS SCIENCE↗

Atomic-Resolution Imaging of Spin-State Superlattices in Nanopockets within Cobaltite Thin Films

Certain complex cobalt oxides are known to exhibit ordered Co spin-states, as determined from neutron scattering and other reciprocal-space or macroscopic techniques. Here we report real-space atomic-resolution imaging of Co spin-state ordering in perovskite La0.5Sr0.5CoO3- thin films. Unlike the bulk material, where neither the O vacancies nor the Co spins are ordered, in the thin film we observe ordered arrays of vacancies, with high-spin Co ions in the planes with O vacancies, and low-spin Co ions in the stoichiometric planes. First-principles calculations provide support for this interpretation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of the Experimental Setup Dedicated for Alpha, Gamma and Electron Spectroscopy of Heavy Nuclei at FLNR JINR

Various types of reactions and identification techniques were applied in the investigation of formation cross sections and decay properties of transuranium elements. The fusion--evaporation reactions with heavy targets, recoil--separation techniques and identification of nuclei by the parent--daughter generic coincidences with the known daughter-nuclei after implantation into position--sensitive detectors were the most successful tools for production and identification of the heaviest elements known presently. This technique may be further improved and presently it may be very promising for the identification of new elements, search for new isotopes and measurement of new decay data for the known nuclei.At the Flerov Laboratory of Nuclear Reactions (JINR, Dubna), investigations of the complete fusion reactions leading to the synthesis of heavy and superheavy nuclei with the use of heavy ion beams from a powerful U400 cyclotron have been an important part of the experimental program. It is planned to upgrade U400 cyclotron of the FLNR, to deliver beams with higher intensities and smooth variation of energies.New experimental set up, the velocity filter, is now developing for synthesis and studies of the decay properties of heavy nuclei. At the focal plane of the separator GABRIELA set up (alpha,beta,gamma detectors array) will be installed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EFFECTS OF DIFFUSE BACKGROUND EMISSION AND SOURCE CROWDING ON PHOTOMETRIC COMPLETENESS IN SPITZER SPACE TELESCOPE IRAC SURVEYS: THE GLIMPSE CATALOGS AND ARCHIVES

We characterize the completeness of point source lists from Spitzer Space Telescope surveys in the four Infrared Array Camera (IRAC) bandpasses, emphasizing the Galactic Legacy Infrared Mid-Plane Survey Extraordinaire (GLIMPSE) programs (GLIMPSE I, II, 3D, 360; Deep GLIMPSE) and their resulting point source Catalogs and Archives. The analysis separately addresses effects of incompleteness resulting from high diffuse background emission and incompleteness resulting from point source confusion (i.e., crowding). An artificial star addition and extraction analysis demonstrates that completeness is strongly dependent on local background brightness and structure, with high-surface-brightness regions suffering up to five magnitudes of reduced sensitivity to point sources. This effect is most pronounced at the IRAC 5.8 and 8.0 {mu}m bands where UV-excited polycyclic aromatic hydrocarbon emission produces bright, complex structures (photodissociation regions). With regard to diffuse background effects, we provide the completeness as a function of stellar magnitude and diffuse background level in graphical and tabular formats. These data are suitable for estimating completeness in the low-source-density limit in any of the four IRAC bands in GLIMPSE Catalogs and Archives and some other Spitzer IRAC programs that employ similar observational strategies and are processed by the GLIMPSE pipeline. By performing the same analysis on smoothed images we show that the point source incompleteness is primarily a consequence of structure in the diffuse background emission rather than photon noise. With regard to source confusion in the high-source-density regions of the Galactic Plane, we provide figures illustrating the 90% completeness levels as a function of point source density at each band. We caution that completeness of the GLIMPSE 360/Deep GLIMPSE Catalogs is suppressed relative to the corresponding Archives as a consequence of rejecting stars that lie in the point-spread function wings of saturated sources. This effect is minor in regions of low saturated star density, such as toward the Outer Galaxy; this effect is significant along sightlines having a high density of saturated sources, especially for Deep GLIMPSE and other programs observing closer to the Galactic center using 12 s or longer exposure times.

79 ASTRONOMY AND ASTROPHYSICS↗

Large-area metallic photonic lattices for military applications.

In this project we developed photonic crystal modeling capability and fabrication technology that is scaleable to large area. An intelligent optimization code was developed to find the optimal structure for the desired spectral response. In terms of fabrication, an exhaustive survey of fabrication techniques that would meet the large area requirement was reduced to Deep X-ray Lithography (DXRL) and nano-imprint. Using DXRL, we fabricated a gold logpile photonic crystal in the <100> plane. For the nano-imprint technique, we fabricated a cubic array of gold squares. These two examples also represent two classes of metallic photonic crystal topologies, the connected network and cermet arrangement.

36 MATERIALS SCIENCE↗