Search NASA⌕ Search

SEARCH · Search NASA

Results for “power load profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Design and Test of an Electromechanical Rover Tether for the Exploration of Vertical Lunar Pit

Moon Diver is a proposed mission to land and deploy an extreme-terrain, tethered rover for the exploration of Tranquillitatis Pit, a large vertical cave entrance into the subsurface of Earth’s Moon. By leveraging a supportive tether, the Axel rover, developed by NASA’s Jet Propulsion Laboratory, would perform a controlled descent into the pit and deploy instruments along the pit wall. The purpose of this mission concept is to study a volcanic secondary crust as a function of depth in order to determine formation processes and chemical makeup. The lifeline of the mission would be the tether, which provides power from, and communication to the top-side lander. Critically, the tether also serves as mechanical support between the suspended rover and the lander, which acts as an anchor. While space tethers have been deployed both in orbit and terrestrially, the use of the proposed tether is unlike any known in the literature; the tether must come into contact with the terrain while under load. With respect to the environment, the tether must also survive abrasion from glassy regolith and volcanic rocks, bending around sharp edges, thermal extremes, and exposure to full spectrum ultra-violet (UV) radiation, all while reliably transferring up to 100 W of power and 1 Mbps of data. Furthermore, since the Axel rover pays out tether from an internal spool, the tether’s diameter must be minimized to increase spool capacity, allowing for up to a 300-m traverse while also meeting static and dynamic strength requirements. This paper covers several phases of the tether’s initial development, including i) a trade study of structure and materials with consideration for space heritage, ii) selected design justification, and iii) results from tests on prototype tethers looking into mechanical, electrical, and environmental properties, including exposure to rock regolith abrasion, load profiles at temperature, and degradation due to UV exposure while exposed to vacuum. Finally, we provide insights and lessons learned from lab and field tests, which inform our continued effort to design a tether capable of surviving rugged, lunar conditions.

Nensas, Issa↗

A Unified Beam-Dynamics and Hardware Design Framework for Hybrid Nonlinear-Kicker Injection in NSLS-II

Nonlinear kickers (NLKs) enable off-axis injection in ultralow-emittance storage rings by providing a strong kick to the injected beam while remaining nearly transparent to the stored beam. In hybrid schemes, a conventional four-kicker bump defines the injected trajectory, and the NLK reduces the first-turn action under constrained beam offset and optics conditions. Effective operation additionally requires stable and reproducible first-turn injection trajectories. We develop a compact action–angle framework that expresses NLK dynamics in terms of Courant–Snyder invariants and yields an analytical bound on achievable action reduction. This formulation provides direct design rules for NLK placement, phase advance, injected-beam offset, and kicker field profile. Within this framework, we identify the 8-wire NLK as a practical baseline and extend its design by relaxing the square-geometry constraint, enabling inward shifting of the off-axis field peak while preserving on-axis field and gradient cancellation. Application to the NSLS-II lattice shows how aperture, pulsed-power, and mechanical constraints combine to determine a coupled design solution. Multi-turn tracking confirms that candidate NLK locations maintain sufficient stay-clear (aperture-clearance) margin, while the optimized wire geometry reduces the required current and Lorentz force load. The results establish a unified approach for NLK-assisted injection design and provide a practical pathway for upgrades in diffraction-limited storage rings.

36 MATERIALS SCIENCE↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative Thermal Performance of Downdraft and Updraft Forced Convection in a Representative 3x3 PWR Fuel Assembly

A plethora of theoretical, numerical, and experimental investigations have relied on updraft forced convection of operating fuel assemblies for light water-cooled fuel assemblies. The inertial scales of turbulence in updraft flow through PWR fuel assemblies are primarily influenced by upstream mixing patterns within the lower plenum and consequent acceleration of flow through the lower core and support plates into the bottom nozzles. In secondary heat transfer applications such as steam generation, recuperation and economization, downdraft flow is utilized to retrieve maximal sensible heat from the primary coolant. Sub-channel volumes aligned vertically could also benefit from force of gravity in developing turbulent flows. A large reduction in pumping power, associated cost of operation and maintenance, and improved balance of plant is suggested to be possible through downdraft forced convection in PWR-type reactors. This article explores the impact of downdraft forced convection within the well-studied 3x3 sub-channel within a range of 20 hydraulic diameters across a representative intermediate flow mixing grid. A range of inflow Reynolds number from 10,000 to 60,000 is simulated over a range of equivalent heat loads of 20% to 100% spanning 20 hydraulic diameters. The fuel rods are represented in true geometric detail, and a constant-value heat profile is assumed for the investigation. At each inflow condition, the turbulence intensity, peak velocity, local heat transfer coefficient, peak wall heat flux, and peak wall temperature are collected across the sub-channel and compared with an updraft configuration evaluated at the same conditions.

Rao, Vivek↗

The MANTA: An RPV design to investigate forces and moments on a lifting surface

The overall goal was to investigate and exploit the advantages of using remotely powered vehicles (RPV's) for in-flight data collection at low Reynold's numbers. The data to be collected is on actual flight loads for any type of rectangular or tapered airfoil section, including vertical and horizontal stabilizers. The data will be on a test specimen using a force-balance system which is located forward of the aircraft to insure an undisturbed air flow over the test section. The collected data of the lift, drag and moment of the test specimen is to be radioed to a grand receiver, thus providing real-time data acquisition. The design of the mission profile and the selection of the instrumentation to satisfy aerodynamic requirements are studied and tested. A half-size demonstrator was constructed and flown to test the flight worthiness of the system.

Bryan, Kevin↗

A Deep Generative Model for Non-Intrusive Identification of EV Charging Profiles

The proliferation of electric vehicles (EVs) brings environmental benefits and technical challenges to power grids. An identification algorithm which can accurately extract individual EV charging profiles out of widely available smart meter measurements has attracted great interests. This paper proposes a non-intrusive identification framework for EV charging profile extraction, which is driven by deep generative models (DGM). First, the proposed DGM is designed as a representation layer embedded into the Markov process and used to model the joint probability distribution of available time-series data. A novel contribution is to approximate posterior distributions by neural networks whose parameters are obtained by variational inference and supervised learning. Second, the EV charging status is inferred from the DGM via dynamic programming. Lastly, the desired EV charging profile can be reconstructed by the rated power of EV models and inferred status. Compared with the benchmark Hidden Markov Models, the proposed framework can better handle noise in data with less computational complexity and better overall accuracy performances with smaller recall. The proposed framework is validated by numerical experiments on the Pecan Street dataset.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation of high-contact-ratio spur gears with profile modification

Scoring tests, surface fatigue tests, and single-tooth bending fatigue tests were conducted with four sets of spur gears of standard design and three sets of spur gears of the new tooth form (NTF) design. Scoring tests were conducted in a gear test rig at a speed of 10,000 rpm using a synthetic polyester C5, C6, C7 substituted pentaerythritol oil. Surface fatigue tests were conducted in the same rig at a speed of 10,000 rpm and Hertz stresses of 173 x 10 to the 7th power and 143 x 10 to the 7th power Pa (250,000 and 214,000 psi). Single tooth bending fatigue tests were conducted on both the standard and NTF gears at an initial load that produced a 10.35 x 10 to the eight power Pa (150,000-psi) bending stress. The gears were load cycled to failure or for 3 x 10 to the 6th power cycles, whichever occurred first. The load was increased after test until failure occurred at 3 x 10 to the 6th power cycles or less. Both the standard and NTF gears scored at a gear bulk temperature of approximately 409 K (277 F). At this temperature the load on the NTF gears was 22 percent less than the load on the standard gears. The scoring failure was a function of gear bulk temperature, where for a given lubricant the temperature is a function of gear design, operating load, and speed.

Townsend, D. P.↗

A 75 kVA Intelligent Power Stages (IPS) Unit Design for Future Grid-interface Application

The demand for grid-interface converter with flexible dc bus is driven by the fast development of energy storage system (ESS), electric vehicle (EV) charging system, and versatile residential load. This paper first proposes a two-stage intelligent power stage (IPS) unit for future grid-interface applications. To achieve zero common-mode (CM) voltage emissions, step-up and step-down voltage gain, a 3-level four-switch buck-boost (3-L FSBB) dc-dc converter is adopted with fully zero voltage switching (ZVS). In one IPS unit, an advanced fiberoptic communication with sub-nanosecond synchronization is developed for different enhanced gate drivers. Moreover, an enhanced gate driver integrated current and voltage sensors is designed for monitoring and diagnostics. To achieve a whole low-profile design, three 12 oz heavy copper planar ac inductors are designed and implemented. Finally, a 75 kVA IPS unit was built to verify both the thermal and electrical design.

Cao, Yuliang↗

Far-field wake-vortex characteristics of wings

Velocity measurements have been made in the wake of wings that were being towed underwater. As the wake aged, measurements of the tangential and axial velocity profiles were made with a two-dimensional scanning laser velocimeter at downstream distances of 5 to 200 span lengths behind wings with different span loadings. The results identify two characteristic flow regions for the dependence of vortex maximum tangential velocity on downstream distance. The first, a region with little, if any, change in maximum tangential velocity, extends from wake rollup to downstream distances as great as 100 span lengths, depending on span loading and angle of attack. This is followed by a decay region in which the maximum tangential velocity decreases with downstream distance at rates nominally proportional to the inverse one-half power.

Ciffone, D. L.↗

An Engineered Multifunctional Composite for Passive Sensing, Power Harvesting, and In Situ Damage Identification with Enhanced Mechanical Performance

A multifunctional fiber-reinforced composite with passive self-sensing, energy-harvesting, and damage detection capabilities is presented. In this work, barium titanate piezoelectric microparticles are deposited on basalt fibers by a scalable, low-cost, environmentally friendly continuous feed-through process. The resulting composite derives a superior interlaminar shear strength from the microparticle-modified fiber–matrix interfaces. The composite also demonstrates passive self-sensing capabilities that produce electrical signals proportional to various dynamic loading events. Vibration and strain-controlled experiments are performed on composite beams to quantify the sensitivity and power output as a function of input acceleration and strain. Furthermore, these composite-generated electrical signals are used to identify in situ damage initiation for structural health monitoring to inform composite damage prior to structural failure. In brief, this truly multifunctional composite simultaneously displays a sensitivity of 0.5–2.6 mV g -1 at a resolution of 0.045–0.20g (g = gravitational acceleration), energy harvesting in the range of nW cc -1 , and prediction of early damage by exhibiting 0.017–1.17 mV peaks in voltage–time history profiles while assuring ≈20% improved interlaminar shear strength.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stochastic Virtual Battery Modeling of Uncertain Electrical Loads using Variational Autoencoder

Effective utilization of flexible loads for grid services, while satisfying end-user preferences and constraints, requires an accurate estimation of the aggregated predictive flexibility offered by the electrical loads. Recently, there have been efforts to quantify the predictive flexibility of thermostatic loads (e.g. residential air-conditioners, electric water-heaters) using the notion of virtual battery (VB), whose state evolution is governed by a first order dynamics including self-dissipation rate, and power and energy capacities. Identifying the VB model parameters for a collection of thermostatic loads, however, is challenging primarily due to uncertainties and lack of information regarding the end-user behavior, underlying device models and parameters. In this paper, we propose a \textit{variational autoencoder}-based deep learning algorithm to identify the parameters of the VB model. Using available sensors and meters data, the proposed algorithm generates not only point estimates of the VB parameters, but also confidence intervals around those values. Effectiveness of the proposed frameworks is demonstrated on a collection of electric water-heater loads, whose operation is driven by uncertain water usage profiles.

virtual battery, deep learning algorithms↗

Estimating the Breakeven Cost of Delivered Electricity to Charge Class 8 Electric Tractors

As vehicle electrification expands from the light-duty sector to include larger commercial medium- and heavy-duty vehicles, businesses need to decide if electrification is appropriate for their fleets. A key factor in this decision will be the total cost of ownership for on-road electric Class 8 tractors compared to their combustion counterparts. This report examines the breakeven price of electricity for electric Class 8 tractor charging to address its importance in the total cost of ownership for the operation of an electrified fleet and to account for the inherent differences of higher-power charging. To understand the likely cost of delivered energy--in this report the breakeven price--to charge electric tractors, this study followed an analysis framework that considers a wide range of factors to estimate the breakeven price to charge at various station types. This requires an estimation of electric vehicle adoption trajectories and analysis of real-world fleet data to assess energy needs of heavy-duty electric tractors and to determine expected charging station demand over time. Station demand informs the level of electric vehicle supply equipment (EVSE) deployment that is necessary at each station type, as well as the site utilization and anticipated load profiles. Then, by accounting for a wide range of capital investments, operating costs, and other expenses, a breakeven price of energy is determined.

33 ADVANCED PROPULSION SYSTEMS↗

A Testbed for Implementing Prognostic Methodologies on Cryogenic Propellant Loading Systems

Prognostics technologies determine the health state of a system and predict its remaining useful life. With this information, operators are able to make maintenance-related decisions, thus effectively streamlining operational and mission-level activities. Experimentation on testbeds representative of critical systems is very useful for the maturation of prognostics technology; precise emulation of actual fault conditions on such a testbed further validates these technologies. In this paper we present the development of a pneumatic valve testbed, initial experimental results and progress towards the maturation and validation of component-level prognostic methods in the context of cryogenic refueling operations. The pneumatic valve testbed allows for the injection of time-varying leaks with specified damage progression profiles in order to emulate common valve faults. The pneumatic valve testbed also contains a battery used to power some pneumatic components, enabling the study of the effects of battery degradation on the operation of the valves.

Prognositcs↗

Characterization and Optimization of the Fitting of Quantum Correlation Functions

This case study presents a characterization and optimization of an application code for extracting parton distribution functions from high energy electron-proton scattering data. Profiling this application code reveals that the phase-space density computation accounts for 93% of the overall execution time for a single iteration on a single core. When executing multiple iterations in parallel on a multicore system, the application spends 78% of its overall execution time idling due to load imbalance. We address these issues by first transforming the application code from Python to C++ and then tackling the application load imbalance via a hybrid scheduling strategy that combines dynamic and static scheduling. These techniques result in a 62% reduction in CPU idle time and a 2.46x speedup in overall execution time per node. In addition, the typically enabled power-management mechanisms in supercomputers (e.g., AMD Turbo Core, Intel Turbo Boost, and RAPL) can significantly impact intra-node scalability when more than 50% of the CPU cores are used. This finding underscores the importance of understanding system interactions with power management, as they can adversely impact application performance, and highlights the necessity of intra-node scaling tests to identify performance degradation that inter-node scaling tests might otherwise overlook.

Chuang, Pi-Yueh [Virginia Tech,Dept. of Computer S↗

Towards Characterizing the Variability in the Loading Demands of an Unmanned Aerial Vehicle

This paper presents a computational methodology to characterize and quantify the variability in the power demands during the take-off of an unmanned aerial vehicle (UAV). A lithium-ion battery-based power system is used to power the unmanned aerial vehicle, and the capabilities of the unmanned aerial vehicle are driven by the amount of charge in this battery. In order to design the power system, it is necessary to analyze the power and charge requirements of the UAV. This paper focuses on the take-off segment, and aims to quantify the amount of charge that is required for this particular segment. Sparse data is available through different flight tests and this data is used to analyze the flight profile and the charge requirement during take-off. The amount of charge required for take-off depends on several factors that are not only variable but cannot be controlled in reality, and hence, the entire flight profile and the corresponding charge requirement are variable in nature. The information available through flight tests is converted into multi-dimensional sparse data and a new method is developed in this paper for variability characterization using multi-dimensional sparse data. This analysis is useful for prognostics and health management where it is necessary to anticipate future charge requirements in order to compute the end-of-discharge of the battery, and hence, the remaining useful life of the power system.

unmanned aerial vehicle↗

Modeling the Potential Impact of Storage on the US Power Sector in a Multisector Dynamic Context

The electric power sector is expected to grow in size, importance, and complexity around the world as economies expand and electric supply technologies and demand patterns evolve in significant ways. At the same time the electric power sector may see substantial increases in VRE generating technologies which can add variability and uncertainty to the diurnal and seasonal profile of electric supply. With these forces in play, the emergence of modular, flexible electricity storage technologies may have profound impacts on the operation of electric power systems. Here we reduce a storage modeling gap in MSD models by incorporating grid-based electricity storage into the electric sector dynamics of the Global Change Analysis Model-USA (GCAM-USA) with improved power sector representation. We find a potentially significant role for storage technologies in the future of the U.S. power system, with storage capacity ranging from 7.7 to 14.7 GW in 2050 and 13.9 to 31.6 GW in 2100 across several techno-economic scenarios. We also find that storage can help to smooth variability in residual load arising from evolving electricity demands and the introduction of high shares of VRE to the electric grid. This reduces reliance on high-cost peaking generators, improves system-wide capacity factors, and limits curtailment of VRE.

Patel, Pralit L.↗

Interplay of intercalation dynamics and lithium plating in monolithic and architectured graphite anodes during fast charging

Fast charging of high-capacity anodes is challenging due to lithium plating reactions, which lead to poor cycling performance and safety concerns. Thus, accurate predictions of plating onset and an understanding of this electrochemical process are crucial for robust battery design. However, the most commonly used models, based on porous electrode theory (e.g., the pseudo-2D model), are notoriously difficult to calibrate due to their complexity, limiting their predictive power. This work studies the process of lithium plating during fast charging of (small-particle) graphite half-cells by measuring local reaction progression and plating behavior using optical operando techniques. These experiments employ a realistic 1D graphite electrode geometry with commercially-relevant mass loading charged at fast charge rates. It is demonstrated that the local reaction progression and plating onset can not only be predicted accurately with a p2D numerical model, but that these processes follow a simple scaling law. Remarkably, the entire reaction histories of different electrodes charged at different rates (e.g., 160 μm thickness at 0.5C, 111 μm at 1C or 66 μm at 4C) were observed to have self-similar intercalation profiles. It is demonstrated that plating onset is in turn governed by the reaction profile which explains why both processes exhibit the same scaling behavior. Finally, operando measurements of local reaction dynamics are conducted for the first time in electrodes with channeled architectures, quantitatively determining how channels affect reaction uniformity and plating onset. Together, these results reveal underlying simplicity in the complex electrochemical environment of fast charging and lithium plating, improving understanding of this process. These fundamental insights are broadly applicable for design processes, modeling and experimental evaluation of lithium ion batteries.

25 ENERGY STORAGE↗

IM3 + EPRI Data Center Load Projections

This dataset contains scenarios of hourly total electricity demand with and without projected loads from data centers over the period 2022-2040. The root projections without data center demands are identical to those documented in Burleyson et al. 2024. In short, those projections encompass hourly electricity demands for 54 Balancing Authorities (BAs) in the United States across a range of eight of weather and socioeconomic scenarios. Refer to the root dataset and accompanying publication, Burleyson et al. 2025, for information about how those projections were generated. For this derivative dataset we used the base loads from the following scenarios: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The root load projections did not reflect the drastic expansion of data centers that has occurred in the last several years to support artificial intelligence and cloud computing. To reflect growth in data center demand, a second set of load projections were created in which we layered in additional data center load projections based on the data center load growth scenarios described in a 2024 report by the Electric Power Research Institute (EPRI): "Powering Intelligence: Analyzing Artificial Intelligence and Data Center Energy Consumption". The EPRI projections from the report are included in this dataset (EPRI_2024_Projections.xlsx). That report contained annual state-level data center load projections for four year-over-year growth rates for data center demands: Low (3.71% annual growth) Moderate (5% annual growth) High (10% annual growth) Higher (15% annual growth) To homogenize the load projections with and without data centers we had to get them to a common scale. The first step was to take the EPRI annual state-level data center energy consumption values and convert them to 8760-hr loads for each year. We did that by assuming a flat (e.g., not weather- or time-sensitive) load profile and distributing the data center loads in each state evenly across all hours in a year. From there the loads were downscaled from the state-level to the county-level using 2019 county-level populations as weights. Finally, the county-level hourly data center loads were summed to the BA-level using the county-to-BA mapping underpinning the root load projections. The net result is 16 (4 weather and socioeconomic scenarios crossed with 4 data center load growth scenarios) unique load projections for the period 2022-2040. The file format follows that of the root dataset with a single additional column "Scaled_TELL_BA_Load_with_DC_MWh" that contains the hourly loads with the added data center loads for a given BA-year-scenario combination. Please refer to the readme file in the root dataset for more information on the file format.

Burleyson, Casey [Pacific Northwest National Labor↗