Search NASA⌕ Search

SEARCH · Search NASA

Results for “power system optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Toward a scalable robust security-constrained optimal power flow using a proximal projection bundle method

Robust security-constrained optimal power flow (rSCOPF) aims to find the worst-case contingencies of alternating current optimal power flow (ACOPF) in power systems. With the rise of GPU architectures on the upcoming supercomputer architectures, optimization algorithms that rely on sparse linear algebra and indefinite linear systems are becoming increasingly hard to solve efficiently (e.g. interior-point method). To address this we revisit a maximin optimization formulation of the rSCOPF and the single-level mixed-integer semidefinite programming (MISDP) reformulation, which is obtained by taking the Lagrangian relaxation of the inner minimization ACOPF problem. In this paper, we focus on the development of a proximal projection bundle method (PPBM) for solving continuous relaxation node subproblems of the MISDP problem, based primarily on the well-known alternating direction method of multipliers. Cutting planes reminiscent of bundle method ideas are also applied in coordination with updates of the proximal parameter. The cutting-plane method can generate a large number of linear inequalities, leading to a large scale but decomposable quadratic programming (QP) subproblem that is amenable to GPUs. We present the numerical results on the IEEE 30, 57, 118, and 300-bus systems by using our PBMM method. We discuss the main computational bottleneck of our method, which is the time taken to solve each iteration of a QP subproblem instance of the PPBM, and how GPU architectures can accelerate this solution process.

bundle method↗

Postdisaster Routing of Movable Energy Resources for Enhanced Distribution System Resilience: A Deep Reinforcement Learning-Based Approach

The deployment of movable energy resources (MERs) can be an effective strategy to restore critical loads to enhance power system resilience when no other energy sources are available after the occurrence of an extreme event. Since the optimal locations of MERs following an extreme event are dependent on system operating states (e.g., the loads at each node, on/off status of system branches, and so on), existing analytical and population-based approaches must repeat the entire analysis and calculation when the system operating states change. On the contrary, if deep reinforcement learning (DRL)-based algorithms are sufficiently trained with a wide range of scenarios, they can quickly find optimal or near-optimal locations irrespective of changes in system states. A deep Q-learning-based approach is proposed for optimal MER deployment to enhance power system resilience. MERs can be also utilized to complement other types of resources, if available. The proposed approach operates in two stages after the occurrence of extreme events. In the first stage, the distribution network is represented as a graph, and the network is then reconfigured using tie switches by using Kruskal’s spanning forest search algorithm (KSFSA). To maximize critical load recovery, the optimal or near-optimal locations of MERs are chosen in the second stage. Further, case studies on a 33-node distribution system and a modified IEEE 123-node system demonstrate the effectiveness of the proposed approach for postdisaster routing of MERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization of Dimensions of Smooth and Twisted-Tape-Inserted Tubes for Heat Transfer with NaCl/KCl/MgCl 2 Molten Salts by Principle of Entropy Generation Minimization

The entropy generation minimization principle is used as the criterion to optimize the flow and heat transfer of solar collectors and heat exchangers that use molten salts NaCl–KCl–MgCl 2 and KCl–MgCl 2 . The Gnielinski correlation for the Nusselt number versus Reynolds number, as well as the Moody friction factor given by Petukhov, was used for the calculation of the convective heat transfer coefficient and pressure loss due to friction in smooth tubes. For twisted-tap-inserted tube, equations of Nu and friction factor provided by Manglik and Bergles were used. The objective function, the entropy generation rate of the heat transfer system, was expressed as the function of Reynolds number, Prandtl number, heating flux, tube diameter, etc. As a result of the analysis, the optimum Reynolds number was determined and thereby to determine the optimum Nusselt number, convective heat transfer coefficient, friction factor, and tube diameter, which also allows the calculation of optimum flow velocity. The analysis was conducted in the fluid temperature range of 500–700 °C, which covers the operation temperature for supercritical CO 2 power cycles in concentrated solar power (CSP) system. Here, optimized results from the smooth tube and twisted-tap-inserted tube are compared, which is important to the design of solar receivers for CSP systems.

14 SOLAR ENERGY↗

A Clustering-Based Scenario Generation Framework for Power Market Simulation with Wind Integration

A critical step in stochastic optimization models of power system analysis is to select a set of appropriate scenarios and significant numbers of scenario generation methods exist in the literature. This paper develops a clustering based scenario generation method, which aims to improve the performance of existing scenario generation techniques by grouping a set of correlated wind sites into clusters according to their cross-correlations. Copula based models are utilized to model spatiotemporal correlations and the Gibbs sampling is then used to generate scenarios for day-ahead markets. Our results show that the generated scenarios based on clustered wind sites outperform existing approaches in terms of reliability and sharpness and can reduce the total computational time for scenario generation and reduction significantly. The clustering-based framework can therefore provide a better support for real-world market simulations with high wind penetration.

data visualization↗

Cyber-Resilient Frequency Control of Power Grids with Energy Storage Systems

The integration of synchronous generators and energy storage systems operated through communication networks introduces new challenges and vulnerabilities to the electric grid, where cyber attacks can corrupt sensor measurements or control inputs and interrupt functions such as frequency regulation. This paper proposes a defense methodology for the design of resilient operating constraints imposed on each generation and storage unit in order to prevent any attack sequence from driving the system's frequency to unsafe conditions. The resilient operating constraints are found by using ellipsoidal approximations of the reachable set of the power system, leading to a convex optimization problem with linear matrix inequalities. Numerical results in a single-area power system with synchronous generation and energy storage demonstrate how the resilient constraints provide security guarantees against any type of attack affecting frequency measurements or controller setpoints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dueco Plug-In Hybrid Engines

Dueco, a final stage manufacture of utility trucks, was awarded a congressionally directed cost shared contract to develop, test, validate, and deploy several PHEV utility trucks. Odyne will be the primary subcontractor responsible for all aspects of the hybrid system including its design and installation on a truck chassis. Key objectives in this program include developing a better understanding of the storage device and system capability; improve aspects of the existing design, optimization of system and power train components, and prototype evaluation. This two year project will culminate in the delivery of at least five vehicles for field evaluation.

33 ADVANCED PROPULSION SYSTEMS↗

Efficiency of the LIFE Laser - Response to a Request for Information from the National Research Council

System models indicate that the required driver efficiency for inertial fusion energy (IFE) should exceed approximately 12-to-14%, and that further efficiency improvements provide diminishing returns on overall system performance. Notably, these studies show that an optimized system will likely employ drivers with suboptimal efficiency from a purely technical standpoint, due to cost vs. efficiency tradeoffs. For this reason, the LIFE laser point design is optimized for the system (power plant) applications, rather than driver efficiency alone. This document describes the anticipated efficiency of the LIFE laser driver, and the basis for this assessment.

42 ENGINEERING↗

Status on the Development of a Modeling and Simulation Framework for the Economic Assessment of Nuclear Hybrid Energy Systems

An effort to design and build a modeling and simulation framework to assess the economic viability of Nuclear Hybrid Energy Systems (NHES) was undertaken in fiscal year 2015 (FY15). The purpose of this report is to document the various tasks associated with the development of such a framework and to provide a status on its progress. Several tasks have been accomplished. First, starting from a simulation strategy, a rigorous mathematical formulation has been achieved in which the economic optimization of a Nuclear Hybrid Energy System is presented as a constrained robust (under uncertainty) optimization problem. Some possible algorithms for the solution of the optimization problem are presented. A variation of the Simultaneous Perturbation Stochastic Approximation algorithm has been implemented in RAVEN and preliminary tests have been performed. The development of the software infrastructure to support the simulation of the whole NHES has also moved forward. The coupling between RAVEN and an implementation of the Modelica language (OpenModelica) has been implemented, migrated under several operating systems and tested using an adapted model of a desalination plant. In particular, this exercise was focused on testing the coupling of the different code systems; testing parallel, computationally expensive simulations on the INL cluster; and providing a proof of concept for the possibility of using surrogate models to represent the different NHES subsystems. Another important step was the porting of the RAVEN code under the Windows™ operating system. This accomplishment makes RAVEN compatible with the development environment that is being used for dynamic simulation of NHES components. A very simplified model of a NHES on the electric market has been built in RAVEN to confirm expectations on the analysis capability of RAVEN to provide insight into system economics and to test the capability of RAVEN to identify limit surfaces even for stochastic constraints. This capability will be needed in the future to enforce the stochastic constraints on the electric demand coverage from the NHES. The development team gained experience with many of the tools that are currently envisioned for use in the economic analysis of NHES and completed several important steps. Given the complexity of the project, preference has been given to a structural approach in which several independent efforts have been used to build the cornerstone of the simulation framework. While this is good approach in establishing such a complex framework, it may delay reaching more complete results on the performance of analyzed system configurations. The integration of the previously reported exergy analysis approach was initially proposed as part of this milestone. However, in reality, the exergy-based apportioning of cost will take place only in a second stage of the implementation since it will be used to properly allocate cost among the different NHES subsystems. Therefore, exergy does not appear at the level of the main drivers in the analysis framework; the latter development of the base framework is the focus of this report.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Community-Centric Microgrid Feasibility Analysis Framework to Accelerate Resilience of Island Communities

Marine energy offers a reliable energy solution for island and coastal communities, which often lack traditional local generation, to support their transition to energy independence and reduce reliance on externally imported fuels. Successful deployment of new technologies in these isolated locations requires community acceptance and approval from the outset, as these communities typically lack the financial and technical resources to operate and maintain new systems. This report presents a community-centric microgrid planning framework for remote coastal and island communities. Community engagement is integrated as the first step in the planning process, incorporating community profiles and visions into energy development scenarios. A case study was conducted in St. George, Pribilof Islands, Alaska, which relies entirely on diesel yet has significant wind and wave energy potential. Community engagement revealed a unique history and current economic status, with an interest in adopting advanced energy technologies despite past failures. Various microgrid configurations were optimized, considering different technologies to meet current and future energy needs while balancing cost and energy resilience. Wave energy converters (WECs) were a key component, integrated with other energy sources using the Xendee optimization tool. The Marine Energy Microgrid Toolkit, developed as part of this work, uses commercial power system analysis tools to optimize and analyze microgrid scenarios. The developed framework and toolkit can be applied to island and coastal communities to enhance resilience and support microgrid deployments. Future enhancements will include incorporating new marine resources, developing dynamic models, and automating the integration of Xendee and PowerFactory simulations.

02 PETROLEUM↗

Short-Term State Forecasting-Based Optimal Voltage Regulation in Distribution Systems: Preprint

A novel short-term state forecasting-based optimal power flow (OPF) approach for distribution system voltage regulation is proposed in this paper. An extreme learning machine (ELM) based state forecaster is developed to accurately predict system states (voltage magnitudes and angles) in the near future. Based on the forecast system states, a dynamically weighted three-phase AC OPF problem is formulated to minimize the voltage violations with higher penalization on buses which are forecast to have higher voltage violations in the near future. By solving the proposed OPF problem, the controllable resources in the system are optimally coordinated to alleviate the potential severe voltage violations and improve the overall voltage profile. The proposed approach has been tested in a 12-bus distribution system and simulation results are presented to demonstrate the performance of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Insulation Design for Transformers in Medium Voltage Power Conversion Systems

Medium-frequency transformers (MFTs) play a crucial role in medium-voltage (MV) solidstate transformer (SST) systems, particularly in extreme fast charging applications. Achieving partial discharge (PD)-free operation while maintaining high power density is a significant challenge due to the high electric field (E-field) stresses inherent in MV applications. This dissertation focuses on the insulation design and optimization of MFTs used in both the main power electronics circuits and auxiliary power supplies. The study begins with an overview of insulation testing methodologies, including high potential tests, basic insulation level tests, and PD tests, which are critical for evaluating MFT insulation reliability. Given the importance of PD-free operation for long-term reliability, particular emphasis is placed on understanding PD mechanisms, including void, corona, and surface discharge, and their mitigation strategies. A high voltage isolated auxiliary power supply is then introduced, utilizing a gapped transformer encapsulated in silicone gel. This design achieves PD-free insulation up to 18 kV RMS while maintaining low coupling capacitance to minimize common-mode current. The proposed solution ensures reliable operation in MV environments and offers a scalable approach for auxiliary power in cascaded SST architectures. To improve MFT insulation in main power conversion circuits, a novel structure is developed using polypropylene sheets and potting compounds to create a void-free air gap, effectively mitigating E-field intensity. A prototype transformer with this insulation structure is built and achieves PD-free operation up to 30 kV RMS. This design is experimentally validated in a resonant converter operating at 46 kW, demonstrating its feasibility for MV SST applications. Further optimization is implemented to enhance MFT performance for dual-active-bridge(DAB) converters by integrating a semiconductive shielding layer within the insulation structure. This shielding layer improves the magnetic coupling coefficient while effectively confining the E-field within high insulation materials, thereby reducing eddy current losses. The optimized MFT achieves PD-free operation at 12.6 kV RMS and is successfully tested in a DAB converter operating at 43 kW, which meets the insulation requirements for a 13.2 kV SST system. This dissertation advances MFT insulation design by introducing and experimentally validating novel approaches that improve high voltage insulation while optimizing magnetic coupling and manufacturability. The proposed insulation structures enable PD-free operation while minimizing insulation material usage and simplifying assembly, making them ideal for high power, high voltage applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Apollo Lunar Roving Vehicle.

After listing the basic requirements such as operational demands and lunar environmental conditions, characteristic design data of the roving vehicle are given with special attention to the four wheel drive and its control system, the steering system, and the navigational instrumentation. The overall system is optimized in view of total mass, range, mobility, load carrying capability, safety, highest reliability through redundancy, and last but not least, cost and development time. Optimization of the drive and power system has first been evaluated by mathematical models and computational simulation of the vehicle hardware, the wheel/soil interaction, and the lunar terrain profile. The next step to refine optimization and evaluation of the drive, steering, and power system including man/machine interaction has been carried out by the use of a six-degree-of-freedom simulator subjecting the astronauts in their space suits to simulated vehicle motions while driving over a simulated terrain, observable on a cathode ray tube display.

Haeussermann, W.↗

Optimal control of the electronic current density: Application to one- and two-dimensional one-electron systems

Quantum optimal control theory is a powerful tool for engineering quantum systems subject to external fields such as the ones created by intense lasers. The formulation relies on a suitable definition for a target functional, that translates the intended physical objective to a mathematical form. We propose the use of target functionals defined in terms of the one-particle density and its current. A strong motivation for this is the possibility of using time-dependent density-functional theory for the description of the system dynamics. We exemplify this idea by defining an objective functional that on one hand attempts a large overlap with a target density and on the other hand minimizes the current. The latter requirement leads to optimized states with increased stability, which we prove with a few examples of one- and two-dimensional one-electron systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Planning for a Resilient Home Electricity Supply System

Resilience of power systems is already a key issue that is getting frequent attention all over the world. It is useful to analyze resilience issues not only for bulk supply, but at all levels including at a customer level. This is because distributed energy resources can play a prominent role in enhancing resilience. Although the literature on planning models, tools and data for bulk supply and distribution systems have expanded in recent years, customer-centric planning, e.g., for an individual household, is yet to receive adequate attention. Although solar PV and battery storage at a household level have been analyzed, how these resources can be optimally combined, together with grid supply, from a resilience perspective is the focus of this study. The study demonstrates how a conceptual framework can be developed to show the trade-off between system costs and resilience including its dimensions such as duration, depth and frequency of service outages. A planning model is developed that incorporates multiple facets of resilience and individual customer preferences. The model considers power system resilience explicitly as a constraint. The model is implemented for a household level case study in Miami, Florida. The results show there are complex trade-offs among different dimensions of resilience. The study demonstrates how combined resilience metrics can be formulated and evaluated using the proposed least-cost planning model at a household level to optimize grid supply together with solar, battery storage and diesel generators. The model allows a planner to directly embed a resilience standard to drive the optimal supply mix. These concepts and the modeling construct can also be applied at other levels of planning, including community level and bulk supply system planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal design and control strategies for novel combined heat and power (CHP) fuel cell systems. Part II of II, case study results.

Innovative energy system optimization models are deployed to evaluate novel fuel cell system (FCS) operating strategies, not typically pursued by commercial industry. Most FCS today are installed according to a 'business-as-usual' approach: (1) stand-alone (unconnected to district heating networks and low-voltage electricity distribution lines), (2) not load following (not producing output equivalent to the instantaneous electrical or thermal demand of surrounding buildings), (3) employing a fairly fixed heat-to-power ratio (producing heat and electricity in a relatively constant ratio to each other), and (4) producing only electricity and no recoverable heat. By contrast, models discussed here consider novel approaches as well. Novel approaches include (1) networking (connecting FCSs to electrical and/or thermal networks), (2) load following (having FCSs produce only the instantaneous electricity or heat demanded by surrounding buildings), (3) employing a variable heat-to-power ratio (such that FCS can vary the ratio of heat and electricity they produce), (4) co-generation (combining the production of electricity and recoverable heat), (5) permutations of these together, and (6) permutations of these combined with more 'business-as-usual' approaches. The detailed assumptions and methods behind these models are described in Part I of this article pair.

30 DIRECT ENERGY CONVERSION↗

Power System Resilience Enhancement in Typhoons Using a Three-Stage Day-Ahead Unit Commitment

In this work, we propose a three-stage resilient unit commitment model which considers uncertain typhoon paths and line outages to improve the power system resilience against typhoon events. The proposed solution coordinates resources in response to the worst-case scenario for each possible typhoon path. The optimal decision is based on the characterization of the power system schedule into three stages of preventive control, emergency control, and restoration. Preventive control is performed before the typhoon occurs by quickly adjusting the three-stage resilient unit commitment schedule; emergency control is conducted during the typhoon by shedding local loads to meet the power balance, while other control strategies are assumed to be unavailable due to possible interruptions in the communication system; restoration is realized after the typhoon, when resources are optimally dispatched to repair the outages of critical devices and recover the normal operation state of the power system quickly. Considering the typhoon path uncertainty, we have introduced a stochastic model for possible typhoon paths where all possible affected lines along each typhoon path are assumed to be on outage during the typhoon. Accordingly, we explore the strategy for co-optimizing the three stages in unit commitment. The proposed model is tested on the IEEE 118-bus system and the real-world provincial system to verify its effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Transformer-less Partial Power Boost Converter for PV Applications Using a Three-Level Switching Cell

Photovoltaic architectures with distributed power electronics provide many advantages in terms of energy yield as well as system level optimization. As the power level of the solar farm increases it becomes more beneficial to increase the dc collection network voltage, which requires the use of power devices with higher voltage ratings, and thus making the design of efficient, low cost, distributed power converters more challenging. In this paper a simple partial power converter topology is proposed. The topology is implemented using a three-level switching cell, which allows the use of semiconductor devices with lower voltage rating; thus improving design and performance and reducing converter cost. This makes the converters suitable for use for medium to high power applications where dc-link voltages of 600V~1kV may be needed without the need for high voltage devices. Converter operation and experimental results are presented for two partial power circuit variants using three-level switching cells.

14 SOLAR ENERGY↗