Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Ionizing-radiation beamline monitoring system

Embodiments are directed generally to an ionizing-radiation beamline monitoring system that includes a vacuum chamber structure with vacuum compatible flanges through which an incident ionizing-radiation beam enters the monitoring system. Embodiments further include at least one scintillator within the vacuum chamber structure that can be at least partially translated in the ionizing-radiation beam while oriented at an angle greater than 10 degrees to a normal of the incident ionizing-radiation beam, a machine vision camera coupled to a light-tight structure at atmospheric/ambient pressure that is attached to the vacuum chamber structure by a flange attached to a vacuum-tight viewport window with the camera and lens optical axis oriented at an angle of less than 80 degrees with respect to a normal of the scintillator, and at least one ultraviolet (“UV”) illumination source facing the scintillator in the ionizing-radiation beam for monitoring a scintillator stability comprising scintillator radiation damage.

Friedman, Peter S.↗

Multifaceted radiation detection and classification system

A system identifying a source of radiation is provided. The system includes a radiation source detector and a radiation source identifier. The radiation source detector receives measurements of radiation; for one or more sources, generates a detection metric indicating whether that source is present in the measurements; and evaluates the detection metrics to detect whether a source is present in the measurements. When the presence of a source in the measurements is detected, the radiation source identifier for one or more sources, generates an identification metric indicating whether that source is present in the measurements; generates a null-hypothesis metric indicating whether no source is present in the measurements; evaluates the one or more identification metrics and the null-hypothesis metric to identify the source, if any, that is present in the measurements.

Labov, Simon E.↗

Ionizing-radiation beamline monitoring system

Embodiments are directed generally to an ionizing-radiation beamline monitoring system that includes a vacuum chamber structure with vacuum compatible flanges through which an incident ionizing-radiation beam enters the monitoring system. Embodiments further include at least one scintillator within the vacuum chamber structure that can be at least partially translated in the ionizing-radiation beam while oriented at an angle greater than 10 degrees to a normal of the incident ionizing-radiation beam, a machine vision camera coupled to a light-tight structure at atmospheric/ambient pressure that is attached to the vacuum chamber structure by a flange attached to a vacuum-tight viewport window with the camera and lens optical axis oriented at an angle of less than 80 degrees with respect to a normal of the scintillator, and at least one ultraviolet (“UV”) illumination source facing the scintillator in the ionizing-radiation beam for monitoring a scintillator stability comprising scintillator radiation damage.

Friedman, Peter S.↗

Construction of a Cosmic Ray Telescope for the hpDIRC Radiators at the Electron Ion Collider

Nuclear physics pertains to the understanding of the structure and dynamics of the nuclei of atoms, accounting for almost all of the visible matter in the universe. The future Electron-Ion Collider (EIC) will play a crucial role in discovering new laws of Nuclear physics. A pivotal aspect of the EIC is exceptional particle identification (PID). Identifying charged hadrons in their final state can be done with special types of Cherenkov Detectors. One type of detector utilizes the Detection of Internally Reflected Cherenkov radiation (DIRC) phenomena. Able to provide precise PID separation up to relatively high momenta, DIRC radiators, made of synthetic fused silica, produce Cherenkov radiation when hit by high energy electromagnetically charged particles. In this thesis we present details of the construction of a cosmic ray telescope (CRT) to utilize high energy muons from cosmic rays to test DIRC radiators. These types of radiators will be used for the high-performance DIRC (hpDIRC) to be used in the ePIC detector in the future EIC. We go into detail on the DIRC process and the individual pieces of hardware required to make the CRT. Lots of labor was used for certain parts of the CRT, specifically the construction of a dark box for the DIRC radiators. The CRT construction and implementation of all of its components are planned to be completed before 2025.

Shankman, Nathan↗

Deciphering the Dynamic Molecular Program of Radiation-Induced Endothelial Senescence

Radiation-induced cellular senescence is a double-edged sword, acting as both a tumor suppression process limiting tumor proliferation, and a crucial process contributing to normal tissue injury. Endothelial cells play a role in normal tissue injury after radiation therapy. Recently, a study observed an accumulation of senescent endothelial cells (ECs) around radiation-induced lung focal lesions following stereotactic radiation injury in mice. However, the effect of radiation on EC senescence remains unclear because it depends on dose and fractionation, and because the senescent phenotype is heterogeneous and dynamic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Countdown to perovskite space launch: Guidelines to performing relevant radiation-hardness experiments

Perovskite photovoltaics (PVs) are under intensive development for promise in terrestrial energy production. Soon, the community will find out how much of that promise may become reality. Perovskites also open new opportunities for lower cost space power. However, radiation tolerance of space environments requires appropriate analysis of relevant devices irradiated under representative radiation conditions. We present guidelines designed to rigorously test the radiation tolerance of perovskite PVs. We review radiation conditions in common orbits, calculate nonionizing and ionizing energy losses (NIEL and IEL) for perovskites, and prioritize proton radiation for effective nuclear interactions. Low-energy protons (0.05-0.15 MeV) create a representative uniform damage profile, whereas higher energy protons (commonly used in ground-based evaluation) require significantly higher fluence to accumulate the equivalent displacement damage dose due to lower scattering probability. Furthermore, high-energy protons may "heal" devices through increased electronic ionization. These procedural guidelines differ from those used to test conventional semiconductors.

14 SOLAR ENERGY↗

Radiation hardness characterization of LKH-5 scintillating glass

Radiation hardness is an important property to examine in scintillators to help determine their expected lifetime in application cases where significant radiation dose is expected. Industrial imaging systems using 9 MV linear accelerators for x-ray radiography are one such application where significant radiation doses are expected to the scintillators used. Cadmium tungstate scintillators (CWO) and Thallium doped Cesium Iodide scintillators (CsI(Tl)) are used in some high energy cargo x-ray radiography systems. However, CWO has a high manufacturing cost for adequately uniform crystals and CsI(Tl) does not have sufficient radiation hardness. LKH-5 glass is being investigated as a potential low cost replacement for CWO and CsI(Tl). In this experiment 36 samples of a terbium doped silicate glass called LKH-5 were irradiated at doses up to 5 MRad using a 9 MV linear accelerator, and the change in their transmission properties was observed. Additionally, the glass was discovered to be a radiation hard glass due to the relatively small change in the transmission of the glass: less than 3% per cm at its emission peak of 550 nm and 5 MRad. This is similar to CWO which has a reported reduction in transmitted light of 2% per cm at 5 MRad and the emission peak of 475 nm and better than CsI(Tl) which is reported to have a reduction in transmitted light of 5% per cm at the emission peak of 550 nm and 4.2 MRad dose. Furthermore, an annealing procedure is described that returned the transmission of the glass to pre-irradiation values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Role of Metal Selection in the Radiation Stability of Isostructural M-UiO-66 Metal–Organic Frameworks

Robust and versatile metal–organic frameworks (MOFs) have emerged as sophisticated scaffolds to meet the critical needs of the nuclear community, but their performance depends on their underexplored structural integrities in high- radiation fields. The contributions of selected metal nodes in the radiation stability of MOFs within the isostructural M-UiO-66 series (where M = Zr, Ce, Hf, Th, and Pu; Zr-UiO-66 experiments were executed in a previous work) have been determined. Ce-, Hf-, and Th-UiO-66 MOF samples were irradiated via gamma and He-ion methodologies to obtain doses up to 3 MGy and 85 MGy, respectively, the latter strikingly higher than that obtained in most other studies. Appreciable self-irradiation constituted the total absorbed doses, up to 31 MGy of the gamma-irradiated Pu-UiO-66 samples. Structural degradation was ascertained by powder X-ray diffraction, X-ray total scattering, vibrational spectroscopy, and, where possible, N 2 physisorption isotherms. Diffuse reflectance infrared Fourier transform spectroscopy provided atomic-level mechanistic insights to reveal that the node-linker connection was most susceptible to radiation damage. Density functional theory calculations were performed on cluster models to evaluate the binding energy of the linkers to each metal node. Here, while the isostructures disclosed the same breakdown signatures, distinct radiation sensitivity as a function of metal selection was evident and followed the trend Hf-UiO-66 ~ Zr-UiO-66 > Th-UiO-66 > Pu-UiO-66 > Ce-UiO-66. We anticipate that these endeavors will contribute to the rational design of radiation-resistant materials for targeted applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transient Radiation-Induced Berkelium(III) and Californium(III) Redox Chemistry in Aqueous Solution

Despite the significant impact of radiation-induced redox reactions on the accessibility and lifetimes of actinide oxidation states, fundamental knowledge of aqueous actinide metal ion radiation chemistry is limited, especially for the late actinides. A quantitative understanding of these intrinsic radiation-induced processes is essential for investigating the fundamental properties of these actinides. We present here a picosecond electron pulse reaction kinetics study into the radiation-induced redox chemistry of trivalent berkelium (Bk(III)) and californium (Cf(III)) ions in acidic aqueous solutions at ambient temperature. New, and first of a kind, second-order rate coefficients are reported for the transient radical-induced reduction of Bk(III) and Cf(III) by the hydrated electron (eaq−) and hydrogen atom (H•), demonstrating significant reactivity (up to 1011M-1s-1) indicative of a preference of these metals to adopt divalent states. Additionally, we reportthe first-ever second-order rate coefficients for the transient radical-induced oxidation of these elements by reaction with hydroxyl (•OH) and nitrate (NO3•) radicals, which also exhibited fast reactivity (ca. 108 M-1s-1). Transient Cf(II), Cf(IV), and Bk(IV) absorption spectra are also reported. Overall, the presented data highlight the existence of rich, complex, intrinsic late actinide radiation-induced redox chemistry that has the potential to influence the findings of other areas of actinide science.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the effects of radiative preheat and self-emission from shock heating on equation of state measurement at 100s of Mbar using spherically converging shock waves in a NIF hohlraum

Over the last six years many experiments have been done at the National Ignition Facility to measure the Hugoniot of materials, such as CH plastic at extreme pressures, up to 800 Mbar. The “Gbar” design employs a strong spherically converging shock launched through a solid ball of material using a hohlraum radiation drive. Here, the shock front conditions are characterized using x-ray radiography. In this paper we examine the role of radiation in heating the unshocked material in front of the shock to understand the impact it has on equation of state measurements and how it drives the measured data off the theoretical Hugoniot curve. In particular, the two main sources of radiation heating are the preheating of the unshocked material by the high-energy kilo-electron-volt x-rays in the hohlraum and the heating of the material in front of the shock, as the shocked material becomes hot enough to radiate significantly. Using our model, we estimate that preheating can reach 4 eV in unshocked material, and that radiation heating can begin to drive data off the Hugoniot significantly, as pressures reach above 400 Mb.

Equations of state↗

Inferring the temperature profile of the radiative shock in the COAX experiment with shock radiography, Dante, and spectral temperature diagnostics

Predicting and modeling the behavior of experiments with radiation waves propagating through low-density foams require a detailed quantification of the numerous uncertainties present. In regimes where a prominent radiative shock is produced, key dynamical features include the shock position, temperature, and curvature and the spatial distribution and temperature of the corresponding supersonic radiation wave. The COAX experimental platform is designed to constrain numerical models of such a radiative shock propagating through a low-density foam by employing radiography for spatial and shock information, Dante for characterizing the x-ray flux from the indirectly driven target, and a novel spectral diagnostic designed to probe the temperature profile of the wave. In this work, we model COAX with parameterized 2D simulations and a Hohlraum-laser modeling package to study uncertainties in diagnosing the experiment. The inferred temperature profile of the COAX radiation transport experiments has been shown to differ from simulations more than expected from drive uncertainties that have been constrained by simultaneous soft x-ray flux and radiography measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-X-point radiation and its dynamics in up/down asymmetry in plasma detachment regimes in Wendelstein 7-X

In Wendelstein 7-X (W7-X), stable plasma detachment in ECRH hydrogen plasmas is routinely achieved with the standard magnetic configuration, containing five magnetic islands in the scrape-off layer (SOL). Plasma detachment induced by intrinsic carbon impurities is characterized by a high radiation fraction (ƒ rad ) with significantly reduced divertor heat load and particle flux. In this work, we present the radiation dynamics during the detached plasma (DP) phase, such as the shift of radiation zones in radial and poloidal directions towards the X-points as ƒ rad increases (∼0.6–0.9), as well as the penetration of the radiation layer into the confinement region in the deep DP phase with ƒ rad approaching unity. In particular, a structure of multi-X-point radiation (multi-XPR) with an up/down asymmetry in the DP phase is highlighted, which is revealed by bolometer tomography and is further confirmed by video diagnostics. The multi-XPR structure forms helical 3D bands aligned with W7-X field periodicity. Field reversal experiments show that the brightest XPR displaces between the upper and lower SOL regions, suggesting the E× B drift effects. This paper presents the multi-XPR structure observed in the W7-X plasma in detail for the first time. A simplified model considering the influence of the poloidal E× B drift ( V d ) on the impurity flow in the SOL shows that the downstream drift toward the target or target shadow region ( V d < 0) decreases the impurity content, while the upstream drift toward the LCFS ( V d > 0) increases the impurity content. On this basis, the poloidal drift potentially leads to an up/down asymmetry of impurity density in the SOL despite the symmetry magnetic topology. The dynamics of the up/down asymmetry in the multi-XPR structure is also related to the magnitude V d /D (normalized to the impurity diffusivity), with an additional effect owing to the radial inward shift of the emission zone. These results provide new insights into impurity-induced detachment dynamics and provide a basis for improving 3D modeling of impurity transport, which typically does not consider drifts.

E × B drift↗

An Improved Algorithm for Estimating Surface Shortwave Radiation: Preliminary Evaluation With MODIS Products

Cloud parameters, as key inputs in radiative transfer algorithms, have a critical impact on surface shortwave radiation (SSR) computation. By introducing a parameterization of cloud transmittance and reflectance, based on radiative transfer simulations, this study improves the accuracy of an existing physically based model which severely underestimates SSR under thick cloud conditions. The cloud parameterization adopts the single-layer cloud model and simulates cloud transmittances and reflectances by varying cloud optical thickness, cloud particle size, and solar zenith angle. The revised model is applied to estimate instantaneous SSR using Moderate-resolution Imaging Spectroradiometer (MODIS) atmospheric and land products. The retrieved SSR is evaluated against observation data from 41 Baseline Surface Radiation Network (BSRN) stations and is also compared with the MODIS official SSR product. The root mean square error (RMSE) of the estimated instantaneous radiation is approximately 52 and 98 W m -2 under clear-sky and all-sky conditions, respectively. The accuracy of the improved parameterization is higher than that of the original model, and there is no obvious underestimation of SSR in the case of high cloud optical thickness. Therefore, the new algorithm improves the accuracy of SSR estimates in the presence of thick clouds. Retrievals with the improved model also achieve higher accuracy than the MODIS official SSR product (MCD18A1). To conclude, the reliable performance of the scheme at most BSRN stations illustrates that the improved model can be used to map SSR on a global scale.

42 ENGINEERING↗

Deep Multitask Learning Models for Radiation Estimation at High Energy Accelerator Facility

Controlling the dose of radiation exposure in potential radioactive facilities is critical for ensuring the safety of staff and the public. Here, in this paper, we developed machine learning models to estimate radiation exposure efficiently at the Thomas Jefferson National Accelerator Facility (JLab), aiming to enhance safety in both accelerator facilities and public areas. Multiple sensors were deployed around the three experimental halls at JLab. Data on single-beam currents, energy levels, and radiation values at the sensor locations were collected during accelerator operation. We proposed a multi-task learning model for radiation estimation, utilizing either one-dimensional convolutional neural networks (1-D CNNs) or long short-term memory networks (LSTMs) as the backbone. The proposed model was trained to simultaneously estimate radiation levels at the sensor locations. Experimental results demonstrated that the proposed model with LSTM backbone achieved the best estimation performance, with an average R 2 score of 0.7557 for estimation within the same year and 0.7157 for estimation across different years. These results significantly surpassed those of competing models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Basic Radiation Theory and Protection [Slides]

Topics for this presentation include isotopes, alpha and beta radiation, x-rays and gamma-rays, neutrons, ionizing radiation, occupational exposure to radiation (CFR limit), radiation exposure amounts, the half-life, radiation protection, inverse square law (1/r 2 ), fission, fusion, and criticality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Modeling Hydrodynamic Instabilities, Shocks, and Radiation Waves in High Energy Density Experiments [Dissertation]

This thesis presents the computational design, modeling, and analysis of three experiments in high-energy density physics (HEDP), all of them concerning fundamental radiation flows. The first experiment is a laboratory astrophysics experiment to investigate the role of the Kelvin-Helmholtz instability (KHI) in the process of galactic filaments supplying gas to galactic halos. The achieved goal was to provide a first study in which the role of the instability is maximal and predict behavior in future iterations of an experiment accessing a more radiative regime where the role of the instability is stifled. This experiment would help answer how certain galaxies are able to grow so rapidly and produce many stars as the KHI limits this process. The second experiment, COAX, is a radiation flow experiment with a novel spectroscopy diagnostic configuration, designed to spatially measure the temperature of a radiation wave as it travels down a doped foam. A key result of this work was the development of a synthetic spectroscopy application and application of modern spectroscopy comparison techniques to provide our first temperature reconstructions from the experimental data. This experimental platform serves as the launching ground for a number of new experiments that vary the basic premise and thus is foundational to our ongoing research. The final experiment is a full integration of modeling, design, and theoretical development for the Radishock experiment. This experimental platform studies the head-on collision of a radiation wave with a counter-propagating shock, and like COAX, uses spectroscopy to diagnose and detect the interaction. My research analyzes the successful shots, indicating aspects of successful detections and suggests improvements to future iterations of the design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Immediate effects of acute Mars mission equivalent doses of SEP and GCR radiation on the murine gastrointestinal system-protective effects of curcumin-loaded nanolipoprotein particles (cNLPs)

Introduction: Missions beyond low Earth orbit (LEO) will expose astronauts to ionizing radiation (IR) in the form of solar energetic particles (SEP) and galactic cosmic rays (GCR) including high atomic number and energy (HZE) nuclei. The gastrointestinal (GI) system is documented to be highly radiosensitive with even relatively low dose IR exposures capable of inducing mucosal lesions and disrupting epithelial barrier function. IR is also an established risk factor for colorectal cancer (CRC) with several studies examining long-term GI effects of SEP/GCR exposure using tumor-prone APC mouse models. Studies of acute short-term effects of modeled space radiation exposures in wildtype mouse models are more limited and necessary to better define charged particle- induced GI pathologies and test novel medical countermeasures (MCMs) to promote astronaut safety. Methods: In this study, we performed ground-based studies where male and female C57BL/6J mice were exposed to γ-rays, 50 MeV protons, or 1 GeV/n Fe-56 ions at the NASA Space Radiation Laboratory (NSRL) with histology and immunohistochemistry endpoints measured in the first 24 h post-irradiation to define immediate SEP/GCR-induced GI alterations. Results: Our data show that unlike matched γ-ray controls, acute exposures to protons and iron ions disrupts intestinal function and induces mucosal lesions, vascular congestion, epithelial barrier breakdown, and marked enlargement of mucosa-associated lymphoid tissue. We also measured kinetics of DNA double-strand break (DSB) repair using gamma-H2AX- specific antibodies and apoptosis via TUNEL labeling, noting the induction and disappearance of extranuclear cytoplasmic DNA marked by gamma-H2AX only in the charged particle-irradiated samples. We show that 18 h pre-treatment with curcumin-loaded nanolipoprotein particles (cNLPs) delivered via IV injection reduces DSB-associated foci levels and apoptosis and restore crypt villi lengths. Discussion: These data improve our understanding of physiological alterations in the GI tract immediately following exposures to modeled space radiations and demonstrates effectiveness of a promising space radiation MCM.

59 BASIC BIOLOGICAL SCIENCES↗

MOCMC: Method of Characteristics Moment Closure, a Numerical Method for Covariant Radiation Magnetohydrodynamics

In this work, we present a conservative numerical method for radiation magnetohydrodynamics with frequency-dependent full transport in stationary spacetimes. This method is stable and accurate for both large and small optical depths and radiation pressures. The radiation stress–energy tensor is evolved in flux-conservative form, and closed with a swarm of samples that each transport a multigroup representation of the invariant specific intensity along a null geodesic. In each zone, the enclosed samples are used to efficiently construct a Delaunay triangulation of the unit sphere in the comoving frame, which in turn is used to calculate the Eddington tensor, average source terms, and adaptively refine the sample swarm. Furthermore, radiation four-forces are evaluated in the moment sector in a semi-implicit fashion. The radiative transfer equation is solved in invariant form deterministically for each sample. Since each sample carries a discrete representation of the full spectrum, the cost of evaluating the transport operator is independent of the number of frequency groups, representing a significant reduction of algorithmic complexity for transport in frequency-dependent problems. The major approximation we make in this work is performing scattering in an angle-averaged way. Local adaptivity in samples also makes this scheme more amenable to nonuniform meshes than a traditional Monte Carlo method. We describe the method and present results on a suite of test problems. We find that Method of Characteristics Moment Closure converges at least as ~N -1 , rather than the canonical Monte Carlo N -1/2 , where N is the number of samples per zone.

79 ASTRONOMY AND ASTROPHYSICS↗