Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference frames”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Virtex-5QV Self Scrubber

This HDL code (hereafter referred to as "software") implements circuitry in Xilinx Virtex-5QV Field Programmable Gate Array (FPGA) hardware. This software allows the device to self-check the consistency of its own configuration memory for radiation-induced errors. The software then provides the capability to correct any single-bit errors detected in the memory using the device's inherent circuitry, or reload corrupted memory frames when larger errors occur that cannot be corrected with the device's built-in error correction and detection scheme.

Wojahn, Christopher K.↗

Demonstration of ACCERT Software for Nuclear Power Plant Techno-Economics

In the past few years, there has been a renewed interest in the deployment of nuclear power for decarbonizing the electricity grid as well as a range of industrial applications. As the demonstrations of advanced nuclear power plants start to begin, there will likely be a further increase in this interest. As nuclear is being considered as a part of the energy mix, understanding the cost of nuclear energy becomes increasingly important for all stakeholders including advanced reactor vendors (for making design decisions and marketing their designs), users of nuclear energy (e.g., to estimate the cost of decarbonization of other industries using nuclear), and government (e.g., in capacity expansion models that are used in framing policy). In this summary, we demonstrate a software tool called ACCERT that is currently being developed with funding from the Systems Analysis and Integration (SA&I) program under the Department of Energy’s Office of Nuclear Energy (DOE NE). ACCERT is a cost estimation and techno-economics tool for nuclear power plant applications that includes a database of (a) cost estimates of various ‘reference’ nuclear power plant designs gathered from existing literature, and (b) algorithms developed from these costs that can be used extrapolate the existing costs and perform a bottom-up cost estimation of other designs. A companion summary describes the software and its design in more detail and this summary presents a demonstration for four different nuclear power plant designs: a pressurized water reactor (PWR), high-temperature gas reactor (HTGR), sodium fast reactor (SFR), and a heat-pipe microreactor. The demonstrations include the reference cost estimates and the cost estimates of a modified design for each reference case.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Faster-Than-Real-Time Framework for Reliability-Oriented Simulation of PV Inverters

Physics-of-Failure (PoF) based reliability assessment for photovoltaic (PV) inverters requires long-duration electrical and electrothermal stress histories, yet generating such stress histories with high-fidelity switching models over year long mission profiles is computationally prohibitive. Conventional methods either sacrifice modeling fidelity for speed or require runtimes that are impractical for design iteration and uncertainty studies. To address this bottleneck, this paper presents a High-Performance Computing (HPC) based simulation frame work for faster-than-real-time reliability-oriented simulation. The proposed framework integrates the Average-to-Switching (A2S) method with parallel computing techniques to accelerate switching-level waveform reconstruction. We further introduce optimization strategies, including cluster merging and sensitivity based mission profile screening, to reduce the computational burden. Evaluated using real-world mission profile inputs and a MATLAB/Simulink switching-model reference, the framework reduces the simulation time for a one-year mission from an intractable multi-year duration to approximately 7.3 minutes while maintaining low waveform error. This acceleration provides a practical reliability-oriented simulation engine that can be coupled with component-specific aging models for subsequent PV inverter PoF assessment.

High-performance Computing↗

Oxo Crater on (1) Ceres: Geological History and the Role of Water-ice

Dwarf planet Ceres (∅ ∼ 940 km) is the largest object in the main asteroid belt. Investigations suggest that Ceres is a thermally evolved, volatile-rich body with potential geological activity, a body that was never completely molten, but one that possibly partially differentiated into a rocky core and an ice-rich mantle, and may contain remnant internal liquid water. Thermal alteration and the infall of exogenic material contribute to producing a (dark) carbonaceous chondritic-like surface containing ammoniated phyllosilicates. Here we report imaging and spectroscopic analyses of data on the bright Oxo crater derived from the Framing Camera and the Visible and Infrared Spectrometer on board the Dawn spacecraft. We confirm that the transitional complex crater Oxo (∅ ∼ 9 km) exhibits exposed surface water-ice. We show that this water-ice-rich material is associated exclusively with two lobate deposits at pole-facing scarps, deposits that also contain carbonates and admixed phyllosilicates. Due to Oxo’s location at −4802 m below the cerean reference ellipsoid and its very young age of only 190 ka (1 σ : +100 ka, −70 ka), Oxo is predestined for ongoing water-ice sublimation.

79 ASTRONOMY AND ASTROPHYSICS↗

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

Novel spirometry based on optical surface imaging

Purpose: To evaluate the feasibility of using optical surface imaging (OSI) to measure the dynamic tidal volume (TV) of the human torso during free breathing. Methods: We performed experiments to measure volume or volume change in geometric and deformable phantoms as well as human subjects using OSI. To assess the accuracy of OSI in volume determination, we performed experiments using five geometric phantoms and two deformable body phantoms and compared the values with those derived from geometric calculations and computed tomography (CT) measurements, respectively. To apply this technique to human subjects, an institutional review board protocol was established and three healthy volunteers were studied. In the human experiment, a high-speed image capture mode of OSI was applied to acquire torso images at 4–5 frames per second, which was synchronized with conventional spirometric measurements at 5 Hz. An in-house MATLAB program was developed to interactively define the volume of interest (VOI), separate the thorax and abdomen, and automatically calculate the thoracic and abdominal volumes within the VOIs. The torso volume change (TV C = ΔV{sub torso} = ΔV{sub thorax} + ΔV{sub abdomen}) was automatically calculated using full-exhalation phase as the reference. The volumetric breathing pattern (BP{sub v} = ΔV{sub thorax}/ΔV{sub torso}) quantifying thoracic and abdominal volume variations was also calculated. Under quiet breathing, TVC should equal the tidal volume measured concurrently by a spirometer with a conversion factor (1.08) accounting for internal and external differences of temperature and moisture. Another MATLAB program was implemented to control the conventional spirometer that was used as the standard. Results: The volumes measured from the OSI imaging of geometric phantoms agreed with the calculated volumes with a discrepancy of 0.0% ± 1.6% (range −1.9% to 2.5%). In measurements from the deformable torso/thorax phantoms, the volume differences measured using OSI imaging and CT imaging were 1.2% ± 2.1% (range −0.5% to 3.6%), with a linear regression fitting (slope = 1.02 and R{sup 2} = 0.999). In volunteers, the relative error in OSI tidal volume measurement was −2.2% ± 4.9% (range −9.2% to 4.8%) and a correlation of r = 0.98 was found with spirometric measurement. The breathing pattern values of the three volunteers were substantially different from each other (BP{sub v} = 0.15, 0.45, and 0.32). Conclusions: This study demonstrates the feasibility of using OSI to measure breathing tidal volumes and breathing patterns with adequate accuracy. This is the first time that dynamic breathing tidal volume as well as breathing patterns is measured using optical surface imaging. The OSI-observed movement of the entire torso could serve as a new respiratory surrogate in the treatment room during radiation therapy.

60 APPLIED LIFE SCIENCES↗

Simulation of CEFR neutronic start-up tests with FENNECS

This paper presents simulation results of selected Neutronic Start-up Tests of the China Experimental Fast Reactor (CEFR) obtained by the neutronics code FENNECS that have been performed within the frame of the IAEA Coordinated Research Program I31032. The Finite Element Neutronics code FENNECS is developed at GRS and solves the few-group steady-state and transient diffusion equation using a Galerkin-based finite element approach. Its main purpose is the safety assessment of Small Modular Reactors and Micro Reactors with complex geometry (e.g., rotating control drums) which gain increased interest internationally. Serpent has been applied to create reference models of the CEFR and cross-section libraries in 10 energy groups for FENNECS. Using these libraries, the following experiments have been simulated with FENNECS: net criticality, control rod integral and differential worth, void reactivity effect, subassembly exchange reactivity effects and reaction rate distribution. The obtained satisfactory agreements with the measurements represent a valuable contribution to the validation of FENNECS. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Status and Promise of Advanced M&V: An Overview of “M&V 2.0” Methods, Tools, and Applications

Advanced measurement and verification (M&V) of energy efficiency savings, often referred to as M&V 2.0 or advanced M&V, is currently an object of much industry attention. Thus far, however, there has been a lack of clarity about what techniques M&V 2.0 includes, how those techniques differ from traditional approaches, what the key considerations are for their use, and what value propositions M&V 2.0 presents to different stakeholders. The objective of this paper is to provide background information and frame key discussion points related to advanced M&V. The paper identifies the benefits, methods, and requirements of advanced M&V and outlines key technical issues for applying these methods. It presents an overview of the distinguishing elements of M&V 2.0 tools and of how the industry is addressing needs for tool testing, consistency, and standardization, and it identifies opportunities for collaboration. In this paper, we consider two key features of M&V 2.0: (1) automated analytics that can provide ongoing, near-real-time savings estimates, and (2) increased data granularity in terms of frequency, volume, or end-use detail. Greater data granularity for large numbers of customers, such as that derived from comprehensive implementation of advanced metering infrastructure (AMI) systems, leads to very large data volumes. This drives interest in automated processing systems. It is worth noting, however, that automated processing can provide value even when applied to less granular data, such as monthly consumption data series. Likewise, more granular data, such as interval or end-use data, delivers value with or without automated processing, provided the processing is manageable. But it is the combination of greater data detail with automated processing that offers the greatest opportunity for value. Using M&V methods that capture load shapes together with automated processing1 can determine savings in near-real time to provide stakeholders with more timely and detailed information. This information can be used to inform ongoing building operations, provide early input on energy efficiency program design, or assess the impact of efficiency by location and time of day. Stakeholders who can make use of such information include regulators, energy efficiency program administrators, program evaluators, contractors and aggregators, building owners, the investment community, and grid planners. Although each stakeholder has its own priorities and challenges related to savings measurement and verification, the potential exists for all to draw from a single set of efficiency valuation data. Such an integrated approach could provide a base consistency across stakeholder uses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TEM Video Compressive Sensing

One of the main limitations of imaging at high spatial and temporal resolution during in-situ TEM experiments is the frame rate of the camera being used to image the dynamic process. While the recent development of direct detectors has provided the hardware to achieve frame rates approaching 0.1ms, the cameras are expensive and must replace existing detectors. In this paper, we examine the use of coded aperture compressive sensing methods [1, 2, 3, 4] to increase the framerate of any camera with simple, low-cost hardware modifications. The coded aperture approach allows multiple sub-frames to be coded and integrated into a single camera frame during the acquisition process, and then extracted upon readout using statistical compressive sensing inversion. Our simulations show that it should be possible to increase the speed of any camera by at least an order of magnitude. Compressive Sensing (CS) combines sensing and compression in one operation, and thus provides an approach that could further improve the temporal resolution while correspondingly reducing the electron dose rate. Because the signal is measured in a compressive manner, fewer total measurements are required. When applied to TEM video capture, compressive imaging couled improve acquisition speed and reduce the electron dose rate. CS is a recent concept, and has come to the forefront due the seminal work of Candès [5]. Since the publication of Candès, there has been enormous growth in the application of CS and development of CS variants. For electron microscopy applications, the concept of CS has also been recently applied to electron tomography [6], and reduction of electron dose in scanning transmission electron microscopy (STEM) imaging [7]. To demonstrate the applicability of coded aperture CS video reconstruction for atomic level imaging, we simulate compressive sensing on observations of Pd nanoparticles and Ag nanoparticles during exposure to high temperatures and other environmental conditions. Figure 1 highlights the results from the Pd nanoparticle experiment. On the left, 10 frames are reconstructed from a single coded frame—the original frames are shown for comparison. On the right a selection of three frames are shown from reconstructions at compression levels 10,20,30. The reconstructions, which are not post-processed, are true to the original and degrade in a straightforward manner. The final choice of compression level will obviously depend on both the temporal and spatial resolution required for a specific imaging task, but the results indicate that an increase in speed of better than an order of magnitude should be possible for all experiments. References: [1] P Llull, X Liao, X Yuan et al. Optics express 21(9), (2013), p. 10526. [2] J Yang, X Yuan, X Liao et al. Image Processing, IEEE Trans 23(11), (2014), p. 4863. [3] X Yuan, J Yang, P Llull et al. In ICIP 2013 (IEEE), p. 14. [4] X Yuan, P Llull, X Liao et al. In CVPR 2014. p. 3318. [5] EJ Candès, J Romberg and T Tao. Information Theory, IEEE Trans 52(2), (2006), p. 489. [6] P Binev, W Dahmen, R DeVore et al. In Modeling Nanoscale Imaging in Electron Microscopy, eds. T Vogt, W Dahmen and P Binev (Springer US), Nanostructure Science and Technology (2012). p. 73. [7] A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41.

Stevens, Andrew↗

NEXAFS Spectroscopy of P3HT and PBTTT at the Sulfur K-Edge

The sulfur K-edge near-edge X-ray absorption fine-structure (NEXAFS) spectra of the common conjugated polymers P3HT and PBTTT are studied from both experimental and theoretical perspectives. Experimental angle-resolved spectra are measured to characterize both the dominant peaks and the dichroism of the polymers. First-principles calculations using the density functional theory-based many-body X-ray absorption spectroscopy (MBXAS) method are performed for the two polymers as well as for the thiophene and thienothiophene units that make up the conjugated backbones of these polymers. Through this combined approach, we are able to confidently assign the observed peaks to specific molecular orbitals and identify the orientation of their transition dipole moments (TDMs) with respect to the coordinate frame of the polymer backbone. Here, in particular, we are able to establish the character and orthogonal nature of the three main low-energy peaks at: (i) 2473.5 eV, 1s → (S–C)­π* with TDM along the π-stacking direction; (ii) 2474.1 eV, 1s → (S–C)­σ* with TDM along the backbone; and (iii) 2475.4 eV, 1s → (S–C)­σ* with TDM perpendicular to the first two. By performing both gas-phase and solid-state simulations, and with reference to the NEXAFS spectra of thiophene and thienothiophene building blocks, the influences of polymerization and molecular packing are also explored.

Chantler, Paul Alexander [Monash University, Clayt↗

Introducing a risk aggregation rationale for mapping risks to aquifers from point- and diffuse-sources–proof-of-concept using contamination data from industrial lagoons

Highlights: • Aquifer risk mapping is introduced for contaminants acting as point/diffuse-sources. • Innovations are framed by risk cells based on Source-Pathway-Receptor-Source (SPRC). • Point-source (Risk Cell 1) and diffuse-source (Risk Cell 2) use sets of algorithms. • Algorithms include MODPATH, DRASTIC, GWPI and are integrated on a modular basis. • Risk Cells 1/2 are aggregated giving fit-for-purpose results as proof-of-concept. - Abstract: Proof-of-concept for a methodology is presented on mapping risks to aquifers impacted from point- and diffuse-sources, where mapping or indexing refers to relative but not absolute values. The methodology is generic but tested by investigating impacts of a risk exposure from industrial wastewater lagoons. The methodology is innovative for using the qualitative Source-Pathways-Receptors-Consequences (SPRC) framework to aggregate risks from both point-sources and diffuse-sources through breaking down a study area into SPRC risk cells. In this paper, two risk cells are required as: (i) Cell 1 is directly impacted from a point-source; and (ii) Cell 2 is impacted by diffuse-sources to slowly contaminate the aquifer by infiltration over a large area. Indexing both types of risk cells generically comprise three tiered processes: (i) binary indexing establishes if a grid cell is at a potential risk or not; (ii) graded indexing measures the strength of the risk pathways from source to receptors; and (iii) local indexing measures intrinsic potentials at the grid cell to propagate the risk. These three processes apply to both point- and diffuse-sources but with different mathematical formulations. The proof-of-concept for the methodology of risk aggregation using the SPRC framework is supported by results of a study area, in which a set of performance metrics are used by comparing with the measurements. The results are found to be fit-for-purpose for serving as proactive management tools and to provide a deeper insight into potential impacts of adverse effects.

54 ENVIRONMENTAL SCIENCES↗

Research on Deformation Law of Deep Foundation Pit of Station in Core Region of Saturated Soft Loess Based on Monitoring

Saturated soft loess has a large pore structure, high compressibility, low strength, fluid plastic state, and poor engineering properties. It is still one of the key problems that engineering needs to solve. In order to study the influence of deep foundation pit excavation in the saturated soft loess area on the deformation of foundation pits, the deformation laws of ground settlement, enclosure structure, and supporting axial force were clarified based on the field tests on the deformation characteristics of deep foundation pits in areas with the high-water level in saturated soft loess, combined with geological conditions and on-site construction procedures. The results indicate the following: water supply and construction process were found to be the main factor in changing the surface settlement curve of deep foundation pits in saturated soft loess; increasing the construction speed of the pit bottom floor, inverted braces, floor frame beams, and sidewall frame beams to close the structure, which is conducive to restraining the deformation of the continuous underground wall and foundation pits in similar areas. In the initial stage of support layout, the axial force of steel support tends to increase too fast or even exceed the standard control value. Therefore, a reasonable preadding axial force is an effective means to control the deformation of the continuous underground wall and the axial force of the steel support. The current research results may provide a reference for constructing deep foundation pits in similar areas.

Wang, Xueyan↗

Experimental Investigation of Laws during Deformation of Circular Roadway in 10° Inclined Layered Rock

In order to analyze the deformation characteristics and mechanisms caused by high tectonic stress in gentle dip strata, a physical modeling with circular tunnel was designed. The model was constructed by the so-called “Physically Finite Elemental Slab Assemblage (PFESA)” to bring about the structural effect of the deep strata. The gravity was fixed while the lateral pressure increased step by step to mimic high tectonic stress. In order to observe the displacement in different area, the sketches of monitoring points and frame in the model surface were drawn down through video pictures in different periods and to be compared. For the sake of analyzing the deformation and failure mechanism of layers, rock structural mechanics models were set up for the left side and right side in the same stratum, respectively. For verifying the experimental phenomenon and its mechanism, infrared images were utilized based on the temperature variation mechanisms of material. Through systematic study, this paper enriches the research methods of model test and can provide a certain reference for practical engineering of similar conditions.

42 ENGINEERING↗

Providing Experimental Infrastructure for Accelerating Advanced Reactor Demonstrations through the National Reactor Innovation Center

A suite of experimental infrastructure projects has been developed by the National Reactor Innovation Center to accelerate advanced reactor demonstrations and facilitate their development, addressing crucial gaps in data, materials characterization, and modeling. First, the Molten Salt Thermophysical Examination Capability (MSTEC) provides a specialized platform for post-irradiation characterization of molten salt reactor fuel, coolant salts, and structural materials, essential for supporting the design and operation of advanced reactors and future commercial molten salt reactor development and licensing. The Virtual Test Bed (VTB) complements these efforts by leveraging advanced modeling and simulation tools to evaluate reactor performance and safety. Serving as a library of reference models, the VTB offers a database of multiphysics reactor models, facilitating rapid safety evaluations and includes continuous software quality assurance, crucial for accelerating deployment while maintaining reliability. Additionally, the Helium Component Test Facility (HeCTF) addresses the need for high-temperature helium-cooled reactor component testing. As the first-of-its-kind facility in the United States, HeCTF emulates high-temperature gas reactor conditions, reducing time and cost associated with component validation, thereby accelerating reactor development. Finally, In-cell Thermal Creep Frames provide a unique solution for obtaining thermal creep data from irradiated materials, critical for materials qualification and licensing. Developed by the National Reactor Innovation Center, these compact frames enable the examination of previously irradiated materials, overcoming traditional limitations and enhancing the understanding of mechanical properties crucial for reactor development. Collectively, these experimental infrastructure projects form a comprehensive framework aimed at expediting advanced reactor demonstrations, fostering innovation, and ensuring the viability of next-generation nuclear energy solutions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A water-based fast integrated mobility spectrometer (WFIMS) with enhanced dynamic size range

We developed a water-based fast integrated mobility spectrometer (WFIMS) with enhanced dynamic size range. The WFIMS builds on two established technologies: the fast integrated mobility spectrometer and laminar flow water-based condensation methodology. Inside WFIMS, particles of differing electrical mobility are separated in a drift tube and subsequently enlarged through water condensation. Particle size and concentration are measured via digital imaging at a frame rate of 10 Hz. When we measure particles of different mobilities simultaneously, the WFIMS resolves particle diameters ranging from 8 to 580 nm within 1 s or less. The performance of WFIMS was characterized with differential mobility analyzer (DMA) classified (NH 4 ) 2 SO 2 particles with diameters ranging from 8 to 265 nm. The mean particle diameters measured by WFIMS were found to be in excellent agreement with DMA centroid diameters. Furthermore, detection efficiency of WFIMS was characterized using a condensation particle counter as a reference and is nearly 100% for particles with diameter greater than 8 nm. In general, measured and simulated WFIMS mobility resolutions are in good agreement. But, some deviations are observed at low particle mobilities, likely due to the non-idealities of the WFIMS electric field.

54 ENVIRONMENTAL SCIENCES↗

Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy

Purpose: To develop an efficient and robust tool for output measurement and absolute dose verification of electron beam therapy by using a high spatial-resolution and high frame-rate amorphous silicon flat panel electronic portal imaging device (EPID). Methods: The dosimetric characteristics of the EPID, including saturation, linearity, and ghosting effect, were first investigated on a Varian Clinac 21EX accelerator. The response kernels of the individual pixels of the EPID to all available electron energies (6, 9, 12, 16, and 20 MeV) were calculated by using Monte Carlo (MC) simulations, which formed the basis to deconvolve an EPID raw images to the incident electron fluence map. The two-dimensional (2D) dose distribution at reference depths in water was obtained by using the constructed fluence map with a MC simulated pencil beam kernel with consideration of the geometric and structural information of the EPID. Output factor measurements were carried out with the EPID at a nominal source–surface distance of 100 cm for 2 × 2, 3 × 3, 6 × 6, 10 × 10, and 15 × 15 cm{sup 2} fields for all available electron energies, and the results were compared with that measured in a solid water phantom using film and a Farmer-type ion chamber. The dose distributions at a reference depth specific to each energy and the flatness and symmetry of the 10 × 10 cm{sup 2} electron beam were also measured using EPID, and the results were compared with ion chamber array and water scan measurements. Finally, three patient cases with various field sizes and irregular cutout shapes were also investigated. Results: EPID-measured dose changed linearly with the monitor units and showed little ghosting effect for dose rate up to 600 MU/min. The flatness and symmetry measured with the EPID were found to be consistent with ion chamber array and water scan measurements. The EPID-measured output factors for standard square fields of 2 × 2, 3 × 3, 6 × 6, 10 × 10, 15 × 15 cm{sup 2} agreed with film and ion chamber measurements. The average discrepancy between EPID and ion chamber/film measurements was 0.81% ± 0.60% (SD) and 1.34% ± 0.75%, respectively. For the three clinical cases, the difference in output between the EPID- and ion chamber array measured values was found to be 1.13% ± 0.11%, 0.54% ± 0.10%, and 0.74% ± 0.11%, respectively. Furthermore, the γ-index analysis showed an excellent agreement between the EPID- and ion chamber array measured dose distributions: 100% of the pixels passed the criteria of 3%/3 mm. When the γ-index was set to be 2%/2 mm, the pass rate was found to be 99.0% ± 0.07%, 98.2% ± 0.14%, and 100% for the three cases. Conclusions: The EPID dosimetry system developed in this work provides an accurate and reliable tool for routine output measurement and dosimetric verification of electron beam therapy. Coupled with its portability and ease of use, the proposed system promises to replace the current film-based approach for fast and reliable assessment of small and irregular electron field dosimetry.

60 APPLIED LIFE SCIENCES↗

WE-D-204-07: Development of An ImageJ Plugin for Renal Function Quantification: RenalQuant

Purpose: Commercial workstations usually have their own software to calculate dynamic renal functions. However, usually they have low flexibility and subjectivity on delimiting kidney and background areas. The aim of this paper is to present a public domain software, called RenalQuant, capable to semi-automatically draw regions of interest on dynamic renal scintigraphies, extracting data and generating renal function quantification parameters. Methods: The software was developed in Java and written as an ImageJ-based plugin. The preprocessing and segmentation steps include the user’s selection of one time frame with higher activity in kidney’s region, compared with background, and low activity in the liver. Next, the chosen time frame is smoothed using a Gaussian low pass spatial filter (σ = 3) for noise reduction and better delimitation of kidneys. The maximum entropy thresholding method is used for segmentation. A background area is automatically placed below each kidney, and the user confirms if these regions are correctly segmented and positioned. Quantitative data are extracted and each renogram and relative renal function (RRF) value is calculated and displayed. Results: RenalQuant plugin was validated using retrospective 20 patients’ 99mTc-DTPA exams, and compared with results produced by commercial workstation software, referred as reference. The renograms intraclass correlation coefficients (ICC) were calculated and false-negative and false-positive RRF values were analyzed. The results showed that ICC values between RenalQuant plugin and reference software for both kidneys’ renograms were higher than 0.75, showing excellent reliability. Conclusion: Our results indicated RenalQuant plugin can be trustingly used to generate renograms, using DICOM dynamic renal scintigraphy exams as input. It is user friendly and user’s interaction occurs at a minimum level. Further studies have to investigate how to increase RRF accuracy and explore how to solve limitations in the segmentation step, mainly when background region has higher activity compared to kidneys. Financial support by CAPES.

60 APPLIED LIFE SCIENCES↗