Search NASA⌕ Search

SEARCH · Search NASA

Results for “reliability estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

behind-the-meter↗

In-Home Mobility Frequency and Stability in Older Adults Living Alone With or Without MCI: Introduction of New Metrics

Background: Older adults spend a considerable amount of time inside their residences; however, most research investigates out-of-home mobility and its health correlates. We measured indoor mobility using room-to-room transitions, tested their psychometric properties, and correlated indoor mobility with cognitive and functional status. Materials and Methods: Community-dwelling older adults living alone ( n = 139; age = 78.1 ± 8.6 years) from the Oregon Center for Aging & Technology (ORCATECH) and Minority Aging Research Study (MARS) were included in the study. Two indoor mobility features were developed using non-parametric parameters (frequency; stability): Indoor mobility frequency (room-to-room transitions/day) was detected using passive infrared (PIR) motion sensors fixed on the walls in four geographic locations (bathroom; bedroom; kitchen; living room) and using door contact sensors attached to the egress door in the entrance. Indoor mobility stability was estimated by variances of number of room-to-room transitions over a week. Test-retest reliability (Intra-class coefficient, ICC) and the minimal clinically important difference (MCID) defined as the standard error of measurement (SEM) were generated. Generalized estimating equations models related mobility features with mild cognitive impairment (MCI) and functional status (gait speed). Results: An average of 206 days (±127) of sensor data were analyzed per individual. Indoor mobility frequency and stability showed good to excellent test-retest reliability (ICCs = 0.91[0.88–0.94]; 0.59[0.48–0.70]). The MCIDs of mobility frequency and mobility stability were 18 and 0.09, respectively. On average, a higher indoor mobility frequency was associated with faster gait speed (β = 0.53, p = 0.04), suggesting an increase of 5.3 room-to-room transitions per day was associated with an increase of 10 cm/s gait speed. A decrease in mobility stability was associated with MCI (β = −0.04, p = 0.03). Discussion: Mobility frequency and stability in the home are clinically meaningful and reliable features. Pervasive-sensing systems deployed in homes can objectively reveal cognitive and functional status in older adults who live alone.

Wu, Chao-Yi↗

Consensus-Based Approach for Active Power Control and Reserve Estimation in Distributed PV Systems: Preprint

With the increased adoption of distributed energy resources (DER), they are expected to contribute to power system reliability services and enhance power system stability. This paper presents a distributed consensus control approach for the real-time active power reserve estimation and power management in distributed PV (photovoltaic) systems. The proposed method estimates the cumulative active power reserve from numerous PV generators using only the sparse communication network for a DER aggregator to provide active power regulation services. The real-time active power reserve estimation using the proposed approach can be used by DER aggregators to manage curtailment in distributed PV systems to maintain stipulated reserves and further to provide power system frequency regulation. Using the proposed approach, the DER aggregator only requires measurements at the feeder substation and it does not require information from individual DER units, thereby improving system resiliency. The proposed distributed consensus control method is validated on IEEE 123 testbed using PSCAD simulations.

active power reserve↗

Detection of significant antiviral drug effects on COVID-19 with reasonable sample sizes in randomized controlled trials: A modeling study

Development of an effective antiviral drug for Coronavirus Disease 2019 (COVID-19) is a global health priority. Although several candidate drugs have been identified through in vitro and in vivo models, consistent and compelling evidence from clinical studies is limited. The lack of evidence from clinical trials may stem in part from the imperfect design of the trials. We investigated how clinical trials for antivirals need to be designed, especially focusing on the sample size in randomized controlled trials. A modeling study was conducted to help understand the reasons behind inconsistent clinical trial findings and to design better clinical trials. We first analyzed longitudinal viral load data for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) without antiviral treatment by use of a within-host virus dynamics model. The fitted viral load was categorized into 3 different groups by a clustering approach. Comparison of the estimated parameters showed that the 3 distinct groups were characterized by different virus decay rates (p-value < 0.001). The mean decay rates were 1.17 d -1 (95% CI: 1.06 to 1.27 d -1 ), 0.777 d -1 (0.716 to 0.838 d -1 ), and 0.450 d -1 (0.378 to 0.522 d -1 ) for the 3 groups, respectively. Such heterogeneity in virus dynamics could be a confounding variable if it is associated with treatment allocation in compassionate use programs (i.e., observational studies). Subsequently, we mimicked randomized controlled trials of antivirals by simulation. An antiviral effect causing a 95% to 99% reduction in viral replication was added to the model. To be realistic, we assumed that randomization and treatment are initiated with some time lag after symptom onset. Using the duration of virus shedding as an outcome, the sample size to detect a statistically significant mean difference between the treatment and placebo groups (1:1 allocation) was 13,603 and 11,670 (when the antiviral effect was 95% and 99%, respectively) per group if all patients are enrolled regardless of timing of randomization. The sample size was reduced to 584 and 458 (when the antiviral effect was 95% and 99%, respectively) if only patients who are treated within 1 day of symptom onset are enrolled. We confirmed the sample size was similarly reduced when using cumulative viral load in log scale as an outcome. We used a conventional virus dynamics model, which may not fully reflect the detailed mechanisms of viral dynamics of SARS-CoV-2. The model needs to be calibrated in terms of both parameter settings and model structure, which would yield more reliable sample size calculation. In this study, we found that estimated association in observational studies can be biased due to large heterogeneity in viral dynamics among infected individuals, and statistically significant effect in randomized controlled trials may be difficult to be detected due to small sample size. The sample size can be dramatically reduced by recruiting patients immediately after developing symptoms. We believe this is the first study investigated the study design of clinical trials for antiviral treatment using the viral dynamics model.

60 APPLIED LIFE SCIENCES↗

GenAI4UQ: A software for forward and inverse uncertainty quantification using conditional generative AI

We introduce GenAI4UQ, a software package for forward and inverse uncertainty quantification in model calibration, parameter estimation, and ensemble forecasting. GenAI4UQ leverages a generative AI-based conditional modeling framework to address limitations of traditional inverse modeling techniques, such as Markov Chain Monte Carlo (MCMC) methods. By replacing computationally intensive iterative processes with a direct, learned mapping, GenAI4UQ enables efficient calibration of input parameters and generation of predictions directly from observations. The software supports rapid ensemble forecasting with robust uncertainty quantification while maintaining computational and storage efficiency. Built-in auto-tuning of hyperparameters simplifies model training, ensuring accessibility for users with varying expertise. Its versatile conditional generative framework is applicable across diverse scientific domains. While GenAI4UQ offers significant advantages in flexibility and efficiency, users should interpret its uncertainty estimates with caution in data-sparse scenarios, as the model may overestimate uncertainty—an effect common to all surrogate-based approaches including MCMC with surrogate models. Despite this, GenAI4UQ transforms inverse modeling by providing a fast, reliable, and user-friendly solution. It empowers researchers and practitioners to quickly estimate parameter distributions and generate model predictions for new observations, facilitating efficient decision-making and advancing the state of uncertainty quantification in computational modeling.

97 MATHEMATICS AND COMPUTING↗

The influence of cloud cover on the reliability of satellite-based solar resource data

Satellite-based solar resource data are often developed and validated by using binary cloudiness categories: clear sky or overcast cloudy sky. To investigate the reliability of solar resource data in partially cloudy conditions, we estimate cloud fraction using two distinct algorithms: a physical retrieval model using surface observed global horizontal irradiance (GHI) and direct normal irradiance (DNI) and a temporal average of cloud mask data estimated by the observed DNI. Our analysis reveals a significant presence of scattered clouds, broken clouds, and mismatches between satellite- and surface-based cloud data at 17 surface sites across the contiguous United States, though confidently clear and cloudy conditions collectively account for more than 70 % of the data. Solar radiation is computed using the National Solar Radiation Database (NSRDB) algorithm and validated using surface observations. Here, our findings suggest that, in the presence of scattered clouds, NSRDB data for clear-sky conditions can be subject to significant overestimation. In cloudy-sky conditions classified by satellite data, DNI computed by the Fast All-sky Radiation Model for Solar applications with DNI (FARMS-DNI) can be underestimated when limited clouds are detected by surface observations. The bias observed in several cloudiness categories indicates that the NSRDB is exceptionally accurate in confidently clear conditions. However, clear-sky conditions with scattered clouds and mismatched cloud data contribute significantly to the overall uncertainties in the NSRDB. Therefore, future improvements in solar resource data should involve development and implementation of satellite-derived cloud fraction and should consider a novel radiative transfer model accounting for amplified cloud reflection. The evaluation within cloudiness categories also provides a physical rationale for the superior performance of FARMS-DNI compared to the Direct Insolation Simulation Code (DISC) in both cloudy-sky and all-sky conditions.

14 SOLAR ENERGY↗

Intra-Specific Variability in Plant Hydraulic Parameters Inferred From Model Inversion of Sap Flux Data

Understanding plant hydraulic regulation is critical for predicting plant and ecosystem responses to projected increases in drought stress. Plant hydraulic regulation is controlled by observable, diverse plant hydraulic traits that can vary as much across individuals of the same species as they do across different species. Direct measurements of plant hydraulic traits from a range of ecosystems remain limited in comparison to other, more readily measured traits (e.g., specific leaf area). Furthermore, plant hydraulic trait measurements, often made at leaf or branch levels, are not easily scaled to whole-plant values that are typically used to predict plant and ecosystem fluxes. In this study, multiple whole-plant hydraulic parameters are inferred from observations of plant water use (i.e., sap flow), soil properties, and meteorological data. We use a Markov Chain Monte Carlo model inversion approach to obtain the best estimates and uncertainty of plant hydraulic parameters that capture whole-plant effective embolism resistance and stomatal sensitivity to decreasing plant water potential. We then use the inferred values in the model to estimate whole-tree water use and isohydricity. This approach reliably infers whole-plant parameter values with enough specificity to resolve inter- and intra-specific differences, and thus supplements time- and labor-intensive direct measurements of traits.

54 ENVIRONMENTAL SCIENCES↗

Impacts of climate change, population growth, and power sector decarbonization on urban building energy use

Climate, technologies, and socio-economic changes will influence future building energy use in cities. However, current low-resolution regional and state-level analyses are insufficient to reliably assist city-level decision-making. Here we estimate mid-century hourly building energy consumption in 277 U.S. urban areas using a bottom-up approach. The projected future climate change results in heterogeneous changes in energy use intensity (EUI) among urban areas, particularly under higher warming scenarios, with on average 10.1–37.7% increases in the frequency of peak building electricity EUI but over 110% increases in some cities. For each 1 °C of warming, the mean city-scale space-conditioning EUI experiences an average increase/decrease of ~14%/ ~ 10% for space cooling/heating. Heterogeneous city-scale building source energy use changes are primarily driven by population and power sector changes, on average ranging from –9% to 40% with consistent south–north gradients under different scenarios. Across the scenarios considered here, the changes in city-scale building source energy use, when averaged over all urban areas, are as follows: –2.5% to –2.0% due to climate change, 7.3% to 52.2% due to population growth, and –17.1% to –8.9% due to power sector decarbonization. Our findings underscore the necessity of considering intercity heterogeneity when developing sustainable and resilient urban energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measuring magnetic fields in laser-driven coils with dual-axis proton deflectometry

Abstract By driving hot electrons between two metal plates connected by a wire loop, high power lasers can generate multi-tesla, quasi-static magnetic fields in miniature coil targets. Many experiments involving laser-coil targets rely on proton deflectometry directed perpendicular to the coil axis to extract a measurement of the magnetic field. In this paper, we show that quantitative measurements using perpendicular probing are complicated by the presence of GV m −1 electric fields in the target that develop on sub-ns timescales. Probing parallel to the coil axis with fiducial grids is shown to reliably separate the electric and magnetic field measurements, giving current estimates of I ≈ 5 kA in 1 mm- and 2 mm-diameter wire loops. An analytic model of proton deflection in electric and magnetic fields is used to benchmark results from the particle-in-cell code and help deconvolve the magnetic and electric field deflections. Results are used to motivate a new experimental scheme that combines a single-plate target with axial proton probing and direct current measurements. This scheme has several important advantages over the traditional target and diagnostic set-up, enabling the robust measurement of coil magnetic fields and plasma properties, as well as making it easier to validate different theoretical models at a range of laser intensities.

Bradford, P. (ORCID:0000000296186342)↗

Structure Factors for Hot Neutron Matter from Ab Initio Lattice Simulations with High-Fidelity Chiral Interactions

We present the first ab initio lattice calculations of spin and density correlations in hot neutron matter using high-fidelity interactions at next-to-next-to-next-to-leading order in chiral effective field theory. These correlations have a large impact on neutrino heating and shock revival in core-collapse supernovae and are encapsulated in functions called structure factors. Unfortunately, calculations of structure factors using high-fidelity chiral interactions were well out of reach using existing computational methods. In this Letter, we solve the problem using a computational approach called the rank-one operator (RO) method. The RO method is a general technique with broad applications to simulations of fermionic many-body systems. It solves the problem of exponential scaling of computational effort when using perturbation theory for higher-body operators and higher-order corrections. Using the RO method, we compute the vector and axial static structure factors for hot neutron matter as a function of temperature and density. Here, the ab initio lattice results are in good agreement with virial expansion calculations at low densities but are more reliable at higher densities. Random phase approximation codes used to estimate neutrino opacity in core-collapse supernovae simulations can now be calibrated with ab initio lattice calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recursive Dynamic Compressive Sensing in Smart Distribution Systems

With a transition to a smarter grid, we are witnessing a significant growth in smart metering infrastructure and sensor deployment in the distribution system. The underlying communication infrastructure is stressed due to the large volume of data that is generated by the smart meters/sensors. Furthermore, real time operations such as state estimation and control are impaired due to the lack of reliable aggregation of the data. In this paper, we exploit the underlying sparsity in grid data to implement two recursive dynamic compressive sensing (CS) approaches-streaming modified weighted-`1 CS and Kalman filtered CS. These approaches aim to reconstruct the sparse signal using the current underdetermined measurements and the prior information about the sparse signal and its support set. Slow signal and support change is in distribution grid data is validated using Pecan Street data. Both the IEEE 34 node test feeder system and PecanStreet data are considered as two examples to validate the superior performance of the two recursive CS techniques relative to classic CS.

Karimi, Hazhar Sufi↗

Beyond Point Estimates: Benchmarking Uncertainty Quantification Methods on the AION-1 Astronomical Foundation Model

Foundation models for astronomical surveys offer powerful learned representations that can be transferred to downstream regression tasks such as galaxy property estimation. However, point predictions alone are insufficient for scientific inference; reliable uncertainty quantification (UQ) is essential. We compare seven UQ methods on galaxy property regression using frozen AION-1 foundation-model embeddings, predicting redshift, stellar mass, stellar-population age, gas-phase metallicity, and specific star-formation rate, from Legacy Survey photometry/imaging and DESI spectra, with PROVABGS-derived labels. Distribution-free conformal methods achieve marginal coverage within $\sim$1 pp of the nominal 90% across all properties, while non-conformal baselines (Deep Ensembles, MC~Dropout) fail to calibrate reliably. Among conformal approaches, Conformalized Quantile Regression (CQR) delivers the best coverage in the bin with the poorest model predictions. More importantly, only the Locally Valid and Discriminative (LVD) framework -- particularly when operating on AION-1 embeddings -- also provides finite-sample \emph{local validity}, producing intervals that adapt to each galaxy's local prediction difficulty rather than relying on marginal guarantees alone. These results establish conformal prediction, and LVD in particular, as the preferred UQ framework for uncertainty-aware inference on foundation-model embeddings in astrophysics.

Tame-Narvaez, Karla [Fermilab] (ORCID:000000022249↗

Improvement of Drop‐Hammer Impact Testing for Safety Assessment of High Explosives Using 10‐mg Samples

Here, in this study, we established an improved method for drop-hammer impact testing of small quantities of high explosives (10 mg). We performed about seven hundred impact tests under various experimental conditions (e.g., sandpaper vs bare anvil, different sample masses, drop-weights, and striker diameters) to determine an optimal set of conditions and reaction detection methods (e.g., gas analysis, video, and sound recordings) that give the most statistically reliable results with 10 mg samples. We used both Frequentist and Bayesian statistical approaches to compare estimates of the drop height (DH50) that initiates a reaction 50% of the time, and to quantify the associated uncertainty. Gas analysis proved to be the most reliable reaction detection method, showing unambiguous rises in HE decomposition products (e.g., CO 2 ) even when the other indicators (e.g., sound, video) were inconclusive. The impact tests performed with a bare anvil showed much better reproducibility than those conducted with sandpaper, reducing the largest uncertainty observed in the data sets by a factor of 1.7. The DH 50 values obtained from three different sample masses (10, 20, and 35 mg) fell within the uncertainties of the measurements. We demonstrated the improved procedure (i.e., 10-mg samples, gas analysis, bare anvil, and Bayesian approach) on a variety of PETN samples having different surface areas and thermal histories.

PETN↗

The mechanical behavior of metal-halide perovskites: Elasticity, plasticity, fracture, and creep

Wide ranging mechanical properties — elasticity, plasticity, fracture, and creep — most relevant to the mechanical reliability of perovskite solar cells (PSCs) are systematically investigated. High quality bulk single-crystals of the commonly studied metal-halide perovskites (MHPs) relevant to PSCs are fabricated and studied: CH 3 NH 3 PbBr 3 (MAPbBr 3 ) and CH 3 NH 3 PbI 3 (MAPbI 3 ). The first direct measurement of MHP Young's modulus (E) using uniaxial compression reveals E <100> of 13.1 ± 1.3 and 10.6 ± 1.0 GPa for MAPbBr 3 and MAPbI 3 , respectively. Further, the Vickers micro-hardness H (100) of MAPbBr 3 and MAPbI 3 is 0.54±0.02 GPa and 0.76±0.05 GPa, respectively. The Vickers micro-indentation fracture toughness K IC of MAPbBr 3 and MAPbI 3 is estimated at 0.20±0.03 MPa∙m 0.5 and 0.18±0.03 MPa∙m 0.5 , respectively. The stress-exponent, n, extracted from nanoindentation creep data is ~8 and ~10 for MAPbBr 3 and MAPbI 3 , respectively. The trends in these properties are discussed. These properties are best estimates and are recommended for use in future mechanical behavior and reliability analyses of MHPs and PSCs.

36 MATERIALS SCIENCE↗

Structure-aware Initialization via Numerical Continuation and Informed Priors

Scientific machine learning (SciML) often operates in ill-conditioned, weakly identifiable regimes due to limited data or indirect observations. In such settings, optimization and inference are highly sensitive to the starting point, making initialization--often under-reported--a consequential degree of freedom. Random initialization is not a neutral default as it induces an implicit prior over candidate solutions and can systematically bias the result, producing large run-to-run variability. Here, we formalize this view by treating initialization as a hidden confounder in SciML and develop a unifying theory for structure-aware initialization via numerical continuation, constructing warm starts from related problem instances. Across representative tasks, including physics-informed neural networks, maximum likelihood estimation, and variational inference, warm starts have been shown to consistently reduce optimization effort and improve reliability.

Data integrity↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Efficient Reliability Analysis using Generalized Multifidelity Modeling and Explainable Active Learning

To assess the reliability of critical technologies like nuclear plants and infrastructure systems and improve the robustness of design, engineers have to quantify the uncertainties surrounding the system behavior accurately. However, the complexity of the problem can make standard reliability analysis algorithms prohibitively expensive, primarily due to the high computational cost of estimating the system response at each iteration. This cost can be greatly reduced by using multi-fidelity modeling and machine learning to build a surrogate model to replace the expensive response function. We propose a general and robust method for building surrogates from multiple Low Fidelity (LF) models coupled with machine learning to retain accuracy. Our framework first constructs “Corrected Low Fidelity models” (CLFs) by coupling a High Fidelity (HF) model inferred Gaussian Process correction term with each of the LF models. It then uses the correction terms to assign model probabilities to each of these CLFs in an explainable way before using them to assemble the final surrogate. No assumptions are made about the type of the LF models or their correlation with the HF model. The proposed surrogate modeling framework is used within the subset simulation algorithm (a variance-reduced MCMC-based reliability analysis algorithm) for enhanced efficiency. Additionally, an active learning step is added to the algorithm to adaptively decide when the surrogate is not sufficiently accurate, at which point the HF model is called and used to refine the surrogate. Through a frame buckling example, our method is shown to be highly efficient at reducing the expensive HF model calls while accurately estimating the failure probability.

97 MATHEMATICS AND COMPUTING↗

Velocity- and pressure-based metrics for estimating strike injuries during fish passage through hydro turbines

Hydropower is a crucial source of clean and reliable energy worldwide, and its importance will continue to grow. To enhance the environmental sustainability of hydropower development and operations, it is essential to predict the strike injury rates of fish passing through turbines accurately and cost-effectively. However, conventional experiments involving a large number of live fish are still commonly conducted in practice, and previous attempts mainly focused on the dose-response relationships at an individual level or relative comparisons of biological characterization between different conditions. Thus, this study proposes two novel strike metrics based on velocity and pressure (M V and M P ) measured by the cutting-edge Sensor Fish (SF) technology, designed to quantify the biological effects of strikes and collisions between fish and rigid hydraulic structures. SF measurements and 48-hour survival rates of live fish from a study conducted at the Ice Harbor Dam on the Snake River were used to establish thresholds for the two proposed metrics. These metrics and thresholds were then applied to three additional SF studies conducted at hydropower facilities featuring Kaplan turbines within the Columbia River basin. Results from the application of the strike metrics indicate that the estimated survival rates derived from both metrics agree well with previously reported live fish survival rates. Furthermore, the study identified specific passage regions with elevated risks of fish mortality due to strikes and collisions. Overall, the proposed strike metrics present a reliable and cost-effective approach to reducing reliance on live fish and lowering costs in fish passage studies.

Biological characterization↗