Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Comparing Designed Training Sets to Optimize Multivariate Regression Models for Pr, Nd, and Nitric Acid Using Spectrophotometry

Chemometric regression models were developed for the quantification of praseodymium (Pr, 0–1000 µg/mL), neodymium (Nd, 0–1000 µg/mL), and nitric acid (HNO 3 , 0.1–5 M) using spectrophotometry. Designed calibration sets were composed of 20 samples each: 10 model points and 10 lack-of-fit (LOF) points. The D-optimal designs effectively minimized the number of samples required to build models, and each design resulted in similar prediction performance, suggesting that statistical design of experiments can provide a reliable framework for selecting training set samples in three-variable systems. Partial least squares regression (PLSR) models were validated against a one-factor-at-a-time validation set composed of 125 samples (three variables, five levels). The top PLS-1 models resulted in average percent root mean square error of prediction error values of 3.5%, 1.7%, and 1.2% for Pr(III), Nd(III), and HNO 3 , respectively. Power set augmentations of the model and LOF samples were investigated to optimize the number of training set samples. PLSR models built using just required model points (10) had similar predictive capabilities as models including the LOF points (20) but with fewer samples. The number of validation samples was also varied systematically to learn how many samples are needed to validate regression models. This work addresses long-standing questions in the field of chemometrics to help make this approach amenable to the near-real-time quantification of hazardous species in remote settings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel rapid oxidizing fusion method to determine Polonium-210 in air filters

A rapid method for the determination of polonium-210 in air filters has been created for use following a radiological event and for routine environmental monitoring. Air filter samples, including cellulose and glass fiber, are fused with a sodium or potassium nitrate/sodium hydroxide flux material. The alkaline matrix minimizes polonium volatility during sample digestion steps, while efficiently dissolving the air filter and inorganic matter implanted on the filter. The addition of nitrate to the flux destroys organic material which can decrease Polonium recovery during precipitation, extraction and source preparation steps. Polonium is concentrated and separated from the sample matrix using an iron hydroxide precipitation and extraction chromatography with DGA Resin. Polonium-210 is subsequently measured by alpha spectrometry following rapid microprecipitation with bismuth phosphate. The new method employs extraction chromatographic purification to remove alpha emitting interferences and sample matrix constituents which can interfere with 210 Po measurements using alpha spectrometry. The novel blend of sodium hydroxide and alkali metal nitrate digests the air filters quickly and effectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Efficient sampling of constrained high-dimensional theoretical spaces with machine learning

Abstract Models of physics beyond the Standard Model often contain a large number of parameters. These form a high-dimensional space that is computationally intractable to fully explore. Experimental results project onto a subspace of parameters that are consistent with those observations, but mapping these constraints to the underlying parameters is also typically intractable. Instead, physicists often resort to scanning small subsets of the full parameter space and testing for experimental consistency. We propose an alternative approach that uses generative models to significantly improve the computational efficiency of sampling high-dimensional parameter spaces. To demonstrate this, we sample the constrained and phenomenological Minimal Supersymmetric Standard Models subject to the requirement that the sampled points are consistent with the measured Higgs boson mass. Our method achieves orders of magnitude improvements in sampling efficiency compared to a brute force search.

Hollingsworth, Jacob↗

Dialysis Extraction for Chromatography

Chromatographic-sample pretreatment by dialysis detects traces of organic contaminants in water samples analyzed in field with minimal analysis equipment and minimal quantities of solvent. Technique also of value wherever aqueous sample and solvent must not make direct contact.

Jahnsen, V. J.↗

Non-Contact Conductivity Measurement for Automated Sample Processing Systems

A new method has been developed for monitoring and control of automated sample processing and preparation especially focusing on desalting of samples before analytical analysis (described in more detail in Automated Desalting Apparatus, (NPO-45428), NASA Tech Briefs, Vol. 34, No. 8 (August 2010), page 44). The use of non-contact conductivity probes, one at the inlet and one at the outlet of the solid phase sample preparation media, allows monitoring of the process, and acts as a trigger for the start of the next step in the sequence (see figure). At each step of the muti-step process, the system is flushed with low-conductivity water, which sets the system back to an overall low-conductivity state. This measurement then triggers the next stage of sample processing protocols, and greatly minimizes use of consumables. In the case of amino acid sample preparation for desalting, the conductivity measurement will define three key conditions for the sample preparation process. First, when the system is neutralized (low conductivity, by washing with excess de-ionized water); second, when the system is acidified, by washing with a strong acid (high conductivity); and third, when the system is at a basic condition of high pH (high conductivity). Taken together, this non-contact conductivity measurement for monitoring sample preparation will not only facilitate automation of the sample preparation and processing, but will also act as a way to optimize the operational time and use of consumables

Beegle, Luther W.↗

Measurement of the orthopositronium confinement energy in mesoporous thin films

In this paper, we present measurements of the ortho-positronium (ortho-Ps) emission energy in vacuum from mesoporous films using the time-of-flight technique. We show evidence of quantum mechanical confinement in the mesopores that defines the minimal energy of the emitted Ps. Two samples with different effective pore sizes, measured with positron annihilation lifetime spectroscopy, are compared for the data collected in the temperature range 50-400 K. The sample with smaller pore size exhibits a higher minimal energy (73{+-}5 meV), compared to the sample with bigger pores (48{+-}5 meV), due to the stronger confinement. The dependence of the emission energy with the temperature of the target is modeled as ortho-Ps being confined in rectangular boxes in thermodynamic equilibrium with the sample. We also measured that the yield of positronium emitted in vacuum is not affected by the temperature of the target.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evolution of the Lunar Receiving Laboratory to the Astromaterial Sample Curation Facility: Technical Tensions Between Containment and Cleanliness, Between Particulate and Organic Cleanliness

The Lunar Receiving Laboratory (LRL) was planned and constructed in the 1960s to support the Apollo program in the context of landing on the Moon and safely returning humans. The enduring science return from that effort is a result of careful curation of planetary materials. Technical decisions for the first facility included sample handling environment (vacuum vs inert gas), and instruments for making basic sample assessment, but the most difficult decision, and most visible, was stringent biosafety vs ultra-clean sample handling. Biosafety required handling of samples in negative pressure gloveboxes and rooms for containment and use of sterilizing protocols and animal/plant models for hazard assessment. Ultra-clean sample handling worked best in positive pressure nitrogen environment gloveboxes in positive pressure rooms, using cleanable tools of tightly controlled composition. The requirements for these two objectives were so different, that the solution was to design and build a new facility for specific purpose of preserving the scientific integrity of the samples. The resulting Lunar Curatorial Facility was designed and constructed, from 1972-1979, with advice and oversight by a very active committee comprised of lunar sample scientists. The high precision analyses required for planetary science are enabled by stringent contamination control of trace elements in the materials and protocols of construction (e.g., trace element screening for paint and flooring materials) and the equipment used in sample handling and storage. As other astromaterials, especially small particles and atoms, were added to the collections curated, the technical tension between particulate cleanliness and organic cleanliness was addressed in more detail. Techniques for minimizing particulate contamination in sample handling environments use high efficiency air filtering techniques typically requiring organic sealants which offgas. Protocols for reducing adventitious carbon on sample handling surfaces often generate particles. Further work is needed to achieve both minimal particulate and adventitious carbon contamination. This paper will discuss these facility topics and others in the historical context of nearly 50 years' curation experience for lunar rocks and regolith, meteorites, cosmic dust, comet particles, solar wind atoms, and asteroid particles at Johnson Space Center.

Allton, J. H.↗

Relativistic beaming and the nuclei of double-lobed quasars

If the simple relativistic beaming model for extragalactic radio sources is at all correct, Doppler boosting may bias us toward choosing those objects pointing nearly at us in flux-density limited samples. In order to minimize any such effects in statistical tests of physical theories of these objects, an attempt is made to define a complete sample of sources with random orientations. For a sample of 26 double-lobed quasars, the dependence of a number of observable features on the angle to the line of sight and on the superluminal velocity is examined, and the distribution of superluminal velocities for the sources is measured. Two new superluminals are reported, and their apparent velocities and nuclear strengths are discussed.

Hough, David H.↗

Installing Deep Groundwater Monitoring Wells in a Volcanic Dominated Rift Basin: Los Alamos National Laboratory, New Mexico - 17594

Los Alamos National Laboratory (LANL, or the Laboratory) is located in northern New Mexico near the west margin of the Espanola Basin. LANL is underlain by a complex basin-fill sequence of alluvial fan deposits, volcanic tuff, basaltic and dacitic lavas, and riverine deposits. On-going environmental remediation and characterization activities have evolved to improve the performance of groundwater monitoring wells, ensuring they yield representative groundwater and core samples. Groundwater occurs as canyon-fill alluvial water, perched intermediate-depth water associated with the basalts and other local-scale perching horizons, and as a regional-scale aquifer that is the main water supply for the area. Anthropogenic contaminants are found in all three groundwater zones. The regional aquifer below LANL is nominally 1000-1400 feet below ground surface (bgs). Monitoring wells at the Laboratory, are therefore, among the deepest routinely installed in the US. Logistical challenges at LANL include steep terrain, widespread cultural sites, and threatened and endangered species habitat restrictions. Additionally, the cost of installing monitoring wells is high because of groundwater depths and the variable drilling techniques that are required to characterize and install wells in a complex geologic environment. A major challenge to the characterization approach at LANL has been to meet sample quality requirements while minimizing drilling costs. In the late 1990's threaded drill-casing was advanced by rotary drilling methods using compressed air as the only circulation fluid. This resulted in relatively low impacts to the geochemical integrity of rock and groundwater samples, but led to frequent episodes of stuck casing. Additional fluids were introduced to the air-rotary program, improving penetration rates, but also resulting in non-representative groundwater samples due to long-term impacts to the aquifer in the vicinity of the well screen. Mud-rotary drilling was incorporated into the program, but it also had significant long-term impacts on groundwater quality, and often inhibited identification of perched groundwater zones and accurate identification of the water table in the regional aquifer. Current drilling practice makes limited use of fluid additives (e.g. foam) to supplement air circulation methods in order to advance drill casing through the vadose zone. Starting about 100 feet above the water table, drill casing is advanced to the target horizon in the regional aquifer using only air and municipal water (when needed) for circulation. Additionally, the threaded drill casing couplings have been replaced with welded connections, significantly reducing the occurrence of stuck casing. Careful observations of water production and water levels during drilling, coupled with the ability to retract casing for video and geophysical logs, now allows for robust characterization of perched groundwater systems and accurate definition of the top of regional saturation. Recent advances in the drilling program include combined dual-rotary/sonic drilling to depths up to 1150 feet and dual-rotary casing advance at angles up to 25 deg. from vertical. The former allows for core collection with minimal fluid addition, thereby preserving pore water chemistry. The latter method allows for well installation into portions of the aquifer otherwise inaccessible due to constraints at the surface (e.g., cultural sites or topography). Similar to the development of drilling techniques, both well design and groundwater sampling system design have evolved throughout the program. Current well design emphasizes a minimal annulus of filter pack, maximum screen slot size based on formation sieve analyses, and thorough well development to mitigate formation damage due to drilling. To sample groundwater at multiple levels in the same well, earlier sampling systems included Westbay{sup R} multi-zone systems and dual-screen single-pump and dual-screen dual-pump systems designed in collaboration with Baski, Inc. These multi-zone sampling systems proved difficult to develop and maintain given the depth to groundwater, and most current well installations are configured with a single screen and a submersible pump. The ability to purge from a well-developed single-screen well has substantially improved the collection of representative groundwater samples. A carefully crafted groundwater characterization program in target aquifers at depths ranging from 1,000 to 1,400 feet bgs within a complex geologic setting, while also retaining the ability to collect representative core and groundwater samples, may have application at a number of sites throughout the environmental industry. Optimizing each well to meet program objectives while reducing total project costs benefits all environmental investigations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ensemble Grouping Strategies for Embedded Stochastic Collocation Methods Applied to Anisotropic Diffusion Problems

Previous work has demonstrated that propagating groups of samples, called ensembles, together through forward simulations can dramatically reduce the aggregate cost of sampling-based uncertainty propagation methods [E. Phipps, M. D'Elia, H. C. Edwards, M. Hoemmen, J. Hu, and S. Rajamanickam, SIAM J. Sci. Comput., 39 (2017), pp. C162--C193]. However, critical to the success of this approach when applied to challenging problems of scientific interest is the grouping of samples into ensembles to minimize the total computational work. For example, the total number of linear solver iterations for ensemble systems may be strongly influenced by which samples form the ensemble when applying iterative linear solvers to parameterized and stochastic linear systems. In this paper we explore sample grouping strategies for local adaptive stochastic collocation methods applied to PDEs with uncertain input data, in particular canonical anisotropic diffusion problems where the diffusion coefficient is modeled by truncated Karhunen--Loève expansions. Finally, we demonstrate that a measure of the total anisotropy of the diffusion coefficient is a good surrogate for the number of linear solver iterations for each sample and therefore provides a simple and effective metric for grouping samples.

97 MATHEMATICS AND COMPUTING↗

Improved Infrared Optical Constants from Pressed Pellets: II. Ellipsometric n and k Values for Ammonium Sulfate with Variability Analysis

Infrared spectral imaging is facilitated via the comparison of spectra recorded in situ to a databank of actual or synthetic infrared reflectance spectra. It has recently been shown that reference spectra corresponding to the many different morphological forms of the same chemical can be generated synthetically using the imaginary, k, and real, n, components of the complex refractive index, n~ = n + ik. One method to obtain the n and k vectors is infrared ellipsometry, which measures the changes in amplitude, tan ?, and phase, ?, of polarized light reflected from the sample both as a function of wavenumber and angle of incidence. The method requires specularly reflected light so best results are usually obtained with polished planar samples of large surface area. Due to the difficulties of obtaining such samples, however, we investigate the possibility of pressing powders of neat materials and obtaining the corresponding optical constants from the pellets. In this paper, variability in the sample pellet and preparation method is investigated, as is variability in the fitting procedure for the derived optical constants. The n/k vectors are derived from the measured ellipsometric parameters, tan ? and ?, as they are fit by an oscillator model which yield n(?) and k(?) vectors as a function of wavenumber, ?. Construction of the oscillator model is not automatic and depends on significant input from the analyst as well as the sample’s physical characteristics. For the pellet pressing, the experimental variability was found to be minimized for size-selected powdered samples as gauged by the minimal variance in ? and ? for three different pellets; similarly, the analytical precision for multiple measurements of the same pellet was also quite good, suggesting that a pressed pellet is a viable sample preparation method. The greatest variability came in the analytic fitting procedure with differences up to 20% arising from four different fits to the same data set. The final ellipsometric n/k data are compared to literature values obtained from crystalline (NH4)2SO4 samples as well as single-angle reflectance measurements that also used pressed pellets. Comparison with the previous literature values shows generally good agreement although higher k-values are observed for the independent sets of data derived from pressed pellets. These data are suggested as an improved set of optical constants for (NH4)2SO4.

optical constants, ellipsometry, ammonium sulfate,↗

Combined Falling Drop/Open Port Sampling Interface System for Automated Flow Injection Mass Spectrometry

The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on the sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.

47 OTHER INSTRUMENTATION↗

International Space Station Urine Monitoring System Functional Integration and Science Testing

Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.

Rodriquez, Branelle R.↗

Shock compression of liquid helium and helium-hydrogen mixtures : development of a cryogenic capability for shock compression of liquid helium on Z, final report for LDRD Project 141536.

This final report on SNL/NM LDRD Project 141536 summarizes progress made toward the development of a cryogenic capability to generate liquid helium (LHe) samples for high accuracy equation-of-state (EOS) measurements on the Z current drive. Accurate data on He properties at Mbar pressures are critical to understanding giant planetary interiors and for validating first principles density functional simulations, but it is difficult to condense LHe samples at very low temperatures (<3.5 K) for experimental studies on gas guns, magnetic and explosive compression devices, and lasers. We have developed a conceptual design for a cryogenic LHe sample system to generate quiescent superfluid LHe samples at 1.5-1.8 K. This cryogenic system adapts the basic elements of a continuously operating, self-regulating {sup 4}He evaporation refrigerator to the constraints of shock compression experiments on Z. To minimize heat load, the sample holder is surrounded by a double layer of thermal radiation shields cooled with LHe to 5 K. Delivery of LHe to the pumped-He evaporator bath is controlled by a flow impedance. The LHe sample holder assembly features modular components and simplified fabrication techniques to reduce cost and complexity to levels required of an expendable device. Prototypes have been fabricated, assembled, and instrumented for initial testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of deflector mode for spin-resolved time-of-flight photoemission spectroscopy

Spin- and angle-resolved photoemission spectroscopy (“spin-ARPES”) is a powerful technique for probing the spin degree-of-freedom in materials with nontrivial topology, magnetism, and strong correlations. Spin-ARPES faces severe experimental challenges compared to conventional ARPES attributed to the dramatically lower efficiency of its detection mechanism, making it crucial for instrumentation developments that improve the overall performance of the technique. Here in this paper, we demonstrate the functionality of our spin-ARPES setup based on time-of-flight spectroscopy and introduce our recent development of an electrostatic deflector mode to map out spin-resolved band structures without sample rotation. We demonstrate the functionality by presenting the spin-resolved spectra of the topological insulator Bi2Te3 and describe in detail the spectrum calibrations based on numerical simulations. By implementing the deflector mode, we minimize the need for sample rotation during measurements, hence improving the overall efficiency of experiments on small or inhomogeneous samples.

47 OTHER INSTRUMENTATION↗

Development of an In Situ Fission Gas Release Instrument for Fuel Sample Irradiations in the High Flux Isotope Reactor

Experimental measurement of gaseous fission product release with respect to temperature and burnup is a critical aspect of understanding nuclear fuel performance, validating predictive models, and qualifying new fuels. To measure this phenomenon in real-time, Oak Ridge National Laboratory has developed an instrument for measuring in situ fission gas release from small-scale fuel samples irradiated in the High Flux Isotope Reactor (HFIR). The instrument uses a continuous flow of Heover the fuel samples to sweep gaseous fission products from a sealed capsule in the HFIR Be reflector to an instrument station adjacent to the reactor. The instrument station houses two high-purity germanium (HPGe) detectors that measure decay gamma rays from fission products passing through a room temperature dwell chamber placed over the detector crystal. The sealed capsules in the reactor are designed to modulate fuel sample temperatures between 700 and 1,100°C by changing the Ar/He gas mixture surrounding the capsules during irradiation. N-type thermocouples are incorporated into the capsule housing to record real-time fuel temperatures. The capsules are heated primarily by prompt gamma rays emitted from the HFIR core with minimal heat contributions from fission in the fuel samples to minimize temperature gradients in the specimens for separate-effects characterization of the material. This paper describes modeling of time-dependent nuclear heating and fission product formation in fuel samples, thermal characteristics of the in-core capsules, and expected gaseous fission product gamma spectra at the HPGe instrument station.

Mulligan, Padhraic L [ORNL] (ORCID:000000025826540↗

Spectral consequences of photoreceptor sampling in the rhesus retina

Optical transforms were used to compute the power spectra of rhesus cones treated as arrays of image sampling points. Spectra were obtained for the central fovea, parafovea, periphery, and far periphery. All were consistent with a novel spatial sampling principle that introduces minimal noise for spatial frequencies below the Nyquist limits implied by local receptor densities, while frequencies above the nominal Nyquist limits are not converted into conspicuous moiree patterns, but instead are scattered into broadband noise. This sampling scheme allows the visual system to escape aliasing distortion despite a large mismatch between retinal image bandwidth and the Nyquist limits implied by extrafoveal cone densities.

Yellott, J. I., Jr.↗

SEM/XPS analysis of fractured adhesively bonded graphite fibre-reinforced polyimide composites

The surfaces of the graphite fiber-reinforced polyimide composites presently pretreated prior to bonding with polyimide adhesive contained variable amounts of a fluoropolymer, as determined by X-ray photoelectron spectroscopy. Lap shear strengths were determined for unaged samples and for those aged over 500- and 1000-hour periods at 177 and 232 C. Unaged sample lap strengths, which were the highest obtained, exhibited no variation with surface pretreatment, but a significant decrease is noted with increasing aging temperature. These thermally aged samples, however, had increased surface fluorine concentration, while a minimal concentration was found in unaged samples. SEM demonstrated a progressive shift from cohesive to adhesive failure for elevated temperature-aged composites.

Devilbiss, T. A.↗