Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Temporal and spatial characterization of a thermogenic, fault-controlled gas hydrate system, Woolsey Mound, Gulf of Mexico

Woolsey Mound, located at Mississippi Canyon Lease Block 118 (MC118), is the site of the Gulf of Mexico hydrate research consortium’s seafloor observatory, where gas hydrates outcrop at the seafloor. The presence of gas hydrates in the mound is confirmed directly by coring and indirectly by 3D seismic reflection data. Craters, pockmarks, chemosynthetic communities, and authigenic carbonates populate the seafloor at Woolsey Mound. Each crater is characterized by a network of shallow crestal faults that connect the hydrate mound to the underlying allochthonous salt body. We characterize the temporal and spatial evolution of gas hydrates at Woolsey Mound under natural perturbations using four collocated 3D seismic reflection data sets that span over 14 years. Data acquisition differences embedded in the data sets arising from variation in geometry, sample rate, and phase are minimized using the “cross-equalization” method. Our results indicate that hydrate formation and dissociation vary temporally and spatially in close connection to the shallow crestal faults. Evidence of gas hydrate dissociation is observed over a period of three years (2000–2003), where major dissociation occurred along the southern portion of the crestal fault in the southeast crater. The dissociation is less prominent in the southwest crater. Evidence of methane venting is observed between 2000 and 2010, which is mostly concentrated in the southeast crater. The residual amplitude anomalies observed between 2000 and 2014 in the mound are mostly positive, implying that the methane venting had increased significantly. The positive anomalies are correlated with the methane seepage recorded in 2011. Our results indicate the evolution of a fault-controlled gas hydrate system in the northern Gulf of Mexico, which would aid in assessing its impact on the seafloor.

Geochemistry & Geophysics↗

Process R&D for Particle Size Control of Molybdenum Oxide

The primary goal of this study was to produce MoO 3 powder with a particle size range of 50 to 200 μm for use in targets for production of the medical isotope 99 Mo. Molybdenum metal powder is commercially produced by thermal reduction of oxides in a hydrogen atmosphere. The most common source material is MoO 3 , which is derived by the thermal decomposition of ammonium heptamolybdate (AHM). However, the particle size of the currently produced MoO 3 is too small, resulting in Mo powder that is too fine to properly sinter and press into the desired target. In this study, effects of heating rate, heating temperature, gas type, gas flow rate, and isothermal heating were investigated for the decomposition of AHM. The main conclusions were as follows: lower heating rate (2-10°C/min) minimizes breakdown of aggregates, recrystallized samples with millimeter-sized aggregates are resistant to various heat treatments, extended isothermal heating at >600°C leads to significant sintering, and inert gas and high gas flow rate (up to 2000 ml/min) did not significantly affect particle size distribution or composition. In addition, attempts to recover AHM from an aqueous solution by several methods (spray drying, precipitation, and low temperature crystallization) failed to achieve the desired particle size range of 50 to 200 μm. Further studies are planned.

36 MATERIALS SCIENCE↗

Experimental Measurements of Soot and Soot Precursors of Sustainable Aviation Fuels

Sustainable Aviation Fuels (SAFs) are promising for decarbonizing the challenging-to-electrify aerospace sector and reducing yearly greenhouse gas emissions by thousands of tons. Developing predictive detailed chemical kinetic models for SAF (and traditional) fuel mixtures necessitates a robust experimental database to elucidate the intricate pyrolysis and oxidation chemistry of SAF fuel blend components. Two critical components of SAF surrogate mixtures are iso-dodecane isomers and trans-decalin. This report characterizes the structure of three slightly sooting, laminar, non-premixed, nitrogen-diluted Planar Mixing Layer Flames (PMLFs) fueled by either pure ethylene, ethylene doped with 1500ppm of either 2,2,4,6,6-pentamethyl-heptane or trans-decalin. The flames have the same stoichiometric mixture fraction and total mole fraction of fuels in the fuel stream (X F,F = X C2H4,F + X Dopant,F = 0.26), resulting in approximately the same maximum temperature (T max ≈ 1800 K) to highlight the effect of doping on soot and its gaseous precursors. The PMLF is unconfined and established between adjacent planar jets of the fuel and oxidizer streams surrounded by annular shielding nitrogen. The flow is stabilized by exhausting the hot buoyant flame products through a slot in a downstream plate onto which the cold flow impinges. Importantly, any horizontal cross-section of the PMLF has a self-similar thermochemical structure of a reactive boundary layer that grows at increasing Height Above the Burner (HAB). Therefore, the horizontal cross-sections of a PMLF can be modeled as a One-Dimensional Counterflow Flame (1D-CF) with very low strain rates which are unachievable in traditional CFs and yield a structure that is several millimeters thick. In brief, the PMLF is ideal for performing spatially resolved measurements with minimal effects of the sampling-induced perturbations, to develop and validate detailed chemical kinetic models on time scales of a few tens of milliseconds that are relevant in aviation applications. The horizontal profiles of C0-C18 gaseous species at HAB = 50 mm and soot volume fraction at 25 and 50 mm are measured using capillary sampling followed by GC-MS analyses and Laser Induced Emission Spectroscopy (LIES), respectively. Additionally, the Elastic Laser Light Scattering (E-LLS) coefficient is measured at HAB = 50 mm and 25 mm to determine the strain rates of the 1D-CFs equivalent to the characterized PMLF horizontal cross sections and the profile of the E-LLS equivalent diameter of soot. The comparison of the results in the base PMLF fueled only by ethylene with those in either doped PMLF in which 1500 ppm of ethylene are replaced with 2,2,4,6,6-pentamethyl-heptane or trans-decalin, reveals that the doping increases the mole fraction of several Polycyclic Aromatic Hydrocarbons (PAHs) at both HABs by a factor of approximately 2.5, and the soot volume fraction at both HABs by factors of ~1.5 for 2,2,4,6,6-pentamethyl-heptane and ~1.25 for trans-decalin doping, respectively. Conversely, doping causes a near doubling of the soot equivalent diameter only at HAB = 50 mm, without significant effects at 25 mm. The experimental results partially validate the tested state-of-the-art detailed chemical kinetic model and also point toward the further improvement of its predictive capabilities.

10 SYNTHETIC FUELS↗

Solid-State Nuclear Magnetic Resonance as a Tool to Probe the Impact of Mechanical Preprocessing on the Structure and Arrangement of Plant Cell Wall Polymers

Efficient separation of the plant cell wall polymers during lignocellulose processing has been historically challenging due to insolubility of the polymers and their propensity for recalcitrant reassembly. Methods, such as “lignin first” extraction techniques, have advanced efficient biomass use, but the molecular mechanisms for recalcitrance remain enigmatic. Here, we discuss how solid-state Nuclear Magnetic Resonance (NMR) approaches report on the 3D organization of cellulose, xylan, and lignin in the plant cell wall. Recent results illustrate that the organization of these polymers varies across biomass sources and sample preparation methods, with even minimal physical processing causing significant effects. These structural differences contribute to variable extraction efficiencies for bioproducts after downstream processing. We propose that solid-state NMR methods can be applied to follow biomass processing, providing an understanding of the polymer rearrangements that can lead to poor yields for the desired bioproducts. The utility of the technique is illustrated for mechanical processing using lab-scale vibratory ball milling of Sorghum bicolor .

59 BASIC BIOLOGICAL SCIENCES↗

A Systematic Search for MeV–GeV Pulsar Wind Nebulae without Gamma-Ray Detected Pulsars

An increasing number of pulsar wind nebulae (PWNe) are being identified in the TeV band by ground-based Imaging Air Cherenkov Telescopes such that they constitute the dominant source class of Galactic TeV emitters. However, MeV–GeV PWN counterparts are still largely lacking. To date, only a dozen PWNe are identified by the Fermi–Large Area Telescope (LAT) in the MeV–GeV band. Most PWNe are located along the Galactic plane embedded within the prominent, diffuse Galactic γ-ray emission, which makes these sources difficult to disentangle from the bright diffuse background. We present a systematic search for γ-ray counterparts to known PWNe in the 300 MeV–2 TeV energy band using the Fermi–LAT. We target the locations of previously identified PWNe that lack detected Fermi–LAT pulsars to minimize associated pulsar contamination. The sample includes six previously identified Fermi PWNe and eight Fermi–LAT sources associated with PWNe. We report the analysis of 58 regions of interest and classify Fermi–LAT detected sources as either a likely PWN or a candidate PWN counterpart based on their morphological and spectral characteristics across the broadband spectrum. There are nine unidentified Fermi–LAT sources that we consider as likely PWN counterparts, which, if confirmed to be PWNe, would greatly increase the PWN population detected by the Fermi–LAT from 12 to 21. The remaining Fermi–LAT detected sources are considered weaker PWN candidates. A second approach in the systematic search for γ-ray emitting PWNe will involve studying the off-pulse phases of Fermi–LAT detected pulsars for the presence of an obscured PWN and will be reported in a subsequent paper.

Acharyya, A. [Univ. of Southern Denmark, Odense (D↗

Low temperature magnetic structure of CeRhIn 5 by neutron diffraction on absorption-optimized samples

Here, two aspects of the ambient pressure magnetic structure of heavy fermion material CeRhIn 5 have remained under some debate since its discovery: whether the structure is indeed an incommensurate helix or a spin density wave, and what is the precise magnitude of the ordered magnetic moment. By using a single crystal sample optimized for hot neutrons to minimize neutron absorption by Rh and In, here we report an ordered moment of $m=0.54(2)\,{{\mu}_{\text{B}}}$. In addition, by using spherical neutron polarimetry measurements on a similar single crystal sample, we have confirmed the helical nature of the magnetic structure, and identified a single chiral domain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

SU-F-T-550: Radiochromic Plastic Thin Sheet Dosimeter: Initial Performance

Purpose: Thin sheets, of a high sensitivity formulation of radiochromic dosimeter, Presage were prepared and evaluated for optical readout. Methods: Sheets of radiochromic polyurethane, 12 cm long, 10 cm wide and 0.2 cm thick were prepared with leuco crystal violet as the reporter molecule. Sample transmission was evaluated at a wavelength of 590 nm with in-house constructed instruments: optical cone beam laser CT scanner, fixed and scanning spot densitometers. Sample sequential irradiations to a total dose of 40 Gy were conducted with a modified, Theratron 60, cobalt radiotherapy machine at dose rates of 1 or 0.25 Gy per minute. Exposure to ambient and readout light was minimized to limit background photochromic signals. Samples were stored at 4°C. Optical activity was assessed from linearly polarized transmission images. Comparison sensitivity measurements with EBT3 film were conducted. Results: Samples were transparent, smooth and pale purple before irradiation. Radiochromic reaction was completed in less than 5 minutes. A linear dose response with a sensitivity of 0.5 cm-1Gy-1 was observed. Micrometer measurements found sheet thickness variations up to 20%. Uniform dose, 2 Gy attenuation images, correlated with local sheet thicknesses. Comparable measurements with EBT3 film were 3 times more sensitive at 1 Gy but above 15 Gy, EBT3 film had lower sensitivity than 0.2 cm thick Presage sheet dosimeter due to its non-linear response. Conclusion: Dose sensitivity provided a 10% decrease in transmission for a 1 Gy dose. Improvements in mold design are expected to allow production of sheets with less than 5% variation in thickness. Above, 10 Gy, Presage sheet dosimeter performance expected to exceed EBT3 film based on linearity, sensitivity, transparency and smoothness of samples. J Adamovics is owner of Heuris Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mining the human urine proteome for monitoring renal transplant injury

The human urinary proteome reflects systemic and inherent renal injury perturbations and can be analyzed to harness specific biomarkers for different kidney transplant injury states. 396 unique urine samples were collected contemporaneously with an allograft biopsy from 396 unique kidney transplant recipients. Centralized, blinded histology on the graft was used to classify matched urine samples into categories of acute rejection (AR), chronic allograft nephropathy (CAN), BK virus nephritis (BKVN), and stable graft (STA). Liquid chromatography–mass spectrometry (LC-MS) based proteomics using iTRAQ based discovery (n=108) and global label-free LC-MS analyses of individual samples (n=137) for quantitative proteome assessment were used in the discovery step. Selected reaction monitoring (SRM) was applied to identify and validate minimal urine protein/peptide biomarkers to accurately segregate organ injury causation and pathology on unique urine samples (n=151). A total of 958 proteins were initially quantified by iTRAQ, 87% of which were also identified among 1574 urine proteins detected in LC-MS validation. 103 urine proteins were significantly (p<0.05) perturbed in injury and enriched for humoral immunity, complement activation, and lymphocyte trafficking. A set of 131 peptides corresponding to 78 proteins were assessed by SRM for their significance in an independent sample cohort. A minimal set of 35 peptides mapping to 33 proteins, were modeled to segregate different injury groups (AUC =93% for AR, 99% for CAN, 83% for BKVN). Urinary proteome discovery and targeted validation identified urine protein fingerprints for non-invasive differentiation of kidney transplant injuries, thus opening the door for personalized immune risk assessment and therapy.

Environmental Molecular Sciences Laboratory↗

Determining pseudoscalar meson photoproduction amplitudes from complete experiments

In preparation for a new generation of complete experiments with the goal of performing a high precision extraction of pseudoscalar meson photo-production amplitudes, we present expressions that allow the direct numerical calculation of matrix elements with arbitrary spin projections from Chew-Goldberger-Low-Nambu (CGLN) amplitudes. We use this numerical tool to verify the most general analytic form of the cross section, dependent upon the three polarization vectors of the beam, target and recoil baryon, including all single, double and triple-polarization terms involving 16 spin-dependent observables. Analytic expressions that determine the recoil baryon polarization are presented, together with examples of their potential use with quasi-4? detectors to deduce observables. We assemble the analytic equations relating the 16 experimental observables and the CGLN amplitudes and use our independent method of numerical evaluation to resolve sign differences that exist in the literature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Changing the Rules of the Game: Used Fuel Studies Outside of a Remote Handling Facility

Recent advances in micro-fabrication tools like the FEI Helios NanoLab 660 dual Focused Ion Beam (FIB) and Scanning Electron Microscope (SEM) now make it possible to easily and reliably prepare micron (or smaller) specimens for analyses or further experimentation. Pacific Northwest National Laboratory (PNNL) has leveraged this capability at the Category II Nuclear Facility, the Radiochemical Processing Laboratory, to facilitate nuclear materials analysis and experimentation of used nuclear fuel. Micron-scale specimens of un-irradiated UO2 fuel pellets of various enrichments from depleted to 4.95% enriched, relative to 235U, were prepared at PNNL and shipped to the University of Missouri’s Research Reactor (MURR) for irradiation. Prior to shipping, samples were attached to commercially available Transmission Electron Microscopy half-grids via ion deposition, which were then housed in specially designed aluminum sample holders approved for use at the reactor facility. This minimized handling and preparation requirements prior to materials analysis after irradiation. Samples were irradiated to a burnup equivalent of 8 – 3,700 MWd/MTU. Additionally, by reducing the size of the specimens, and therefore their emitted radiation dose, the required cooling time after irradiation and prior to analysis was greatly diminished, and handling of these samples could proceed outside of a hot cell facility. Results from these experiments provided insight into the initial production of noble metal phase particles in used nuclear fuel at extremely low burnup levels. Some incompatibility with the container was observed at higher burnup. Micro-scale irradiation experiments were performed at roughly 1/7th of the time, effort and expense a similar bulk-scale study requiring a shielded hot cell facility would require. Conducting nuclear materials analysis at the micron-scale holds the promise of enhancing collaboration and material accessibility to the broader research community, improving accessibility to cutting edge research tools by the nuclear materials science community, lowering the risk to the scientist by reducing radiation dose and exposure, reducing facility and research costs associated with the requirement to conduct nuclear materials science within glovebox or remote handling facilities, and minimizing waste.

Schwantes, Jon M.↗

Nanoscale biochemical sample preparation and analysis

Provided herein are methods and systems for biochemical analysis, including compositions and methods for processing and analysis of small cell populations and biological samples (e.g., a robotically controlled chip-based nanodroplet platform). In particular aspects, the methods described herein can reduce total processing volumes from conventional volumes to nanoliter volumes within a single reactor vessel (e.g., within a single droplet reactor) while minimizing losses, such as due to sample evaporation.

Kelly, Ryan T.↗

Environmental associations of Ophidiomyces ophidiicola , the causative agent of ophidiomycosis in snakes

Emerging pathogenic fungi have become a topic of conservation concern due to declines observed in several host taxa. One emerging fungal pathogen, Ophidiomyces ophidiicola, is well documented as the causative agent of ophidiomycosis, otherwise known as snake fungal disease (SFD). O. ophidiicola has been found to cause disease in a variety of snake species across the United States, including the eastern massasauga (Sistrurus catenatus), a federally threatened rattlesnake species. Most work to date has involved detecting O. ophidiicola for diagnosis of infection through direct sampling of snakes, and attempts to detect O. ophidiicola in the abiotic environment to better understand its distribution, seasonality, and habitat associations are lacking. We collected topsoil and groundwater samples from four macrohabitat types across multiple seasons in northern Michigan at a site where Ophidiomyces infection has been confirmed in eastern massasauga. Using a quantitative PCR (qPCR) assay developed for O. ophidiicola, we detected Ophidiomyces DNA in topsoil but observed minimal to no detection in groundwater samples. Detection frequency did not differ between habitats, but samples grouped seasonally showed higher detection during mid-summer. We found no relationships of detection with hypothesized environmental correlates such as soil pH, temperature, or moisture content. Furthermore, the distribution of Ophidiomyces positive samples across the site was not linked to estimated space use of massasaugas. Our data suggests that season has some effect on the presence of Ophidiomyces. Differences in presence between habitats may exist but are likely more dependent on the time of sampling and currently uninvestigated soil or biotic parameters. These findings build on our understanding of Ophidiomyces ecology and epidemiology to help inform where and when snakes may be exposed to the fungus in the environment.

59 BASIC BIOLOGICAL SCIENCES↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

Design and operation of the wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source

The wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source (SNS) is optimized to provide a high neutron flux at the sample position with a large solid angle of detector coverage. The instrument incorporates modern neutron instrumentation, such as an elliptically focused neutron guide, high speed magnetic bearing choppers, and a massive array of {sup 3}He linear position sensitive detectors. Novel features of the spectrometer include the use of a large gate valve between the sample and detector vacuum chambers and the placement of the detectors within the vacuum, both of which provide a window-free final flight path to minimize background scattering while allowing rapid changing of the sample and sample environment equipment. ARCS views the SNS decoupled ambient temperature water moderator, using neutrons with incident energy typically in the range from 15 to 1500 meV. This range, coupled with the large detector coverage, allows a wide variety of studies of excitations in condensed matter, such as lattice dynamics and magnetism, in both powder and single-crystal samples. Comparisons of early results to both analytical and Monte Carlo simulation of the instrument performance demonstrate that the instrument is operating as expected and its neutronic performance is understood. ARCS is currently in the SNS user program and continues to improve its scientific productivity by incorporating new instrumentation to increase the range of science covered and improve its effectiveness in data collection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aggressive Sampling for Multi-class to Binary Reduction with Applications to Text Classification

We address the problem of multi-class classification in the case where the number of classes is very large. We propose a double sampling strategy on top of a multi-class to binary reduction strategy, which transforms the original multi-class problem into a binary classification problem over pairs of examples. The aim of the sampling strategy is to overcome the curse of long-tailed class distributions exhibited in majority of large-scale multi-class classification problems and to reduce the number of pairs of examples in the expanded data. We show that this strategy does not alter the consistency of the empirical risk minimization principle defined over the double sample reduction. As a result, experiments are carried out on DMOZ and Wikipedia collections with 10,000 to 100,000 classes where we show the efficiency of the proposed approach in terms of training and prediction time, memory consumption, and predictive performance with respect to state-of-the-art approaches.

97 MATHEMATICS AND COMPUTING↗

Compadre Toolkit

The Compadre Toolkit solves a minimization problem, that once solved allows a user to reconstruct a function from sample data collected from a cloud of data sites. The solution to this minimization can also be used to assemble a linear system that can be solved numerically using some other software. The minimization problem the toolkit solves is to find the optimal finite polynomial in a user specified finite dimensional space with regards to minimizing an objective function which measures a linear sampling functional applied to the polynomial, compared to the same sampling functional applied to the source function, weighted by a positive kernel that has compact support.

SciDAC↗