Search NASA⌕ Search

SEARCH · Search NASA

Results for “semiconductor detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Design and Performance of a Miniature Lidar Wind Profiler (MLWP)

The directional velocity of the wind is one of the most critical components for understanding meteorological and other dynamic atmospheric processes. Altitude-resolved wind velocity measurements, also known as wind profiles or soundings, are especially necessary for providing data for meteorological forecasting and overall global circulation models (GCM's). Wind profiler data are also critical in identifying possible dangerous weather conditions for aviation. Furthermore, a system has yet to be developed for wind profiling from the surface of Mars which could also meet the stringent requirements on size, weight, and power of such a mission. Obviously, a novel wind profiling approach based on small and efficient technology is required to meet these needs. A lidar system based on small and highly efficient semiconductor lasers is now feasible due to recent developments in the laser and detector technologies. The recent development of high detection efficiency (50%), silicon-based photon-counting detectors when combined with high laser pulse repetition rates and long receiver integration times has allowed these transmitter energies to be reduced to the order of microjoules per pulse. Aerosol lidar systems using this technique have been demonstrated for both Q-switched, diode-pumped solid-state laser transmitters (lambda = 523 nm) and semiconductor diode lasers (lambda = 830 nm); however, a wind profiling lidar based on this technique has yet to be developed. We will present an investigation of a semiconductor-laser-based lidar system which uses the "edge-filter" direct detection technique to infer Doppler frequency shifts of signals backscattered from aerosols in the planetary boundary layer (PBL). Our investigation will incorporate a novel semiconductor laser design which mitigates the deleterious effects of frequency chirp in pulsed diode lasers, a problem which has limited their use in such systems in the past. Our miniature lidar could be used on a future Mars lander and perhaps find its own niche in terrestrial applications due to its potential low cost an small size.

Cornwell, Donald M., Jr.↗

Physical Properties of Candidate X-ray Detector Material Rb 4 Ag 2 BiBr 9

Recently, metal halide perovskites have emerged as promising semiconductor candidates for sensitive X-ray photon detection due to their suitable band gap energies, excellent charge transport properties, and low material cost afforded by their low-temperature solution-processing preparation. Furthermore, we report an improved methodology for single crystal growth and thermal and electrical properties of a two-dimensional (2D) layered halide material Rb 4 Ag 2 BiBr 9 , which has been identified as a potential candidate for X-ray radiation detection applications. The measured heat capacity for Rb 4 Ag 2 BiBr 9 implies that there are no structural phase transitions upon cooling. Temperature dependence of thermal transport measurements further suggests remarkably low thermal conductivities of Rb 4 Ag 2 BiBr 9 that are comparable to the lowest reported in literature. The bulk crystal resistivity is determined to be 2.59 × 10 9 Ω·cm from the current–voltage (I–V) curve. Density of trap states is estimated to be ~10 10 cm –3 using the space-charge-limited-current measurements. The fabricated Rb 4 Ag 2 BiBr 9 -based X-ray detector shows good operational stability with no apparent current drift, which may be ascribed to the 2D crystal structure of Rb 4 Ag 2 BiBr 9 . Finally, by varying the X-ray tube current to change the corresponding dose rate, the Rb4Ag2BiBr9 X-ray detector sensitivity is determined to be 222.03 μC Gy –1 cm –2 (at an electric field of E = 24 V/mm).

36 MATERIALS SCIENCE↗

An Acoustic Charge Transport Imager for High Definition Television

This project, over its term, included funding to a variety of companies and organizations. In addition to Georgia Tech these included Florida Atlantic University with Dr. William E. Glenn as the P.I., Kodak with Mr. Mike Richardson as the P.I. and M.I.T./Polaroid with Dr. Richard Solomon as the P.I. The focus of the work conducted by these organizations was the development of camera hardware for High Definition Television (HDTV). The focus of the research at Georgia Tech was the development of new semiconductor technology to achieve a next generation solid state imager chip that would operate at a high frame rate (I 70 frames per second), operate at low light levels (via the use of avalanche photodiodes as the detector element) and contain 2 million pixels. The actual cost required to create this new semiconductor technology was probably at least 5 or 6 times the investment made under this program and hence we fell short of achieving this rather grand goal. We did, however, produce a number of spin-off technologies as a result of our efforts. These include, among others, improved avalanche photodiode structures, significant advancement of the state of understanding of ZnO/GaAs structures and significant contributions to the analysis of general GaAs semiconductor devices and the design of Surface Acoustic Wave resonator filters for wireless communication. More of these will be described in the report. The work conducted at the partner sites resulted in the development of 4 prototype HDTV cameras. The HDTV camera developed by Kodak uses the Kodak KAI-2091M high- definition monochrome image sensor. This progressively-scanned charge-coupled device (CCD) can operate at video frame rates and has 9 gm square pixels. The photosensitive area has a 16:9 aspect ratio and is consistent with the "Common Image Format" (CIF). It features an active image area of 1928 horizontal by 1084 vertical pixels and has a 55% fill factor. The camera is designed to operate in continuous mode with an output data rate of 5MHz, which gives a maximum frame rate of 4 frames per second. The MIT/Polaroid group developed two cameras under this program. The cameras have effectively four times the current video spatial resolution and at 60 frames per second are double the normal video frame rate.

Hunt, William D.↗

Compact Full-Field Ion Detector System for CubeSat Science Beyond LEO

NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop a Compact Full-Field Ion Detector System (CFIDS). The CFIDS is designed to be an extremely compact, low cost instrument, capable of being flown on a wide variety of deep space platforms, to provide comprehensive (composition, velocity, and direction) in situ measurements of heavy ions in space plasma environments with higher fidelity, than previously available.

Extraterrestrial Radiation↗

Slicing Newton spheres with a two-camera 3D imaging system

We demonstrate a simple approach to achieve three-dimensional ion momentum imaging. The method employs two complementary metal–oxide–semiconductor cameras in addition to a standard microchannel plates/phosphor screen imaging detector. The two cameras are timed to measure the decay of luminescence excited by ion hits to extract the time of flight. The achieved time resolution is better than 10 ns, which is mainly limited by camera jitters. A better than 5 ns resolution can be achieved when the jitter is suppressed.

Chemistry↗

Purification and Crystal Growth of Lead Iodide by Physical Vapor Transport Method

Lead iodide (PbI2) is a layered compound semiconductor being developed as room temperature x- and gamma-ray detector. Compared to the more studied material, mercuric iodide, PbI2 has a higher melting temperature and no phase transition until liquid phase which are indications of better mechanical properties. In this study, the source material was purified by the zone-refining process, and the purest section was extracted from center of the the zone-refined ingot to be grown by physical vapor transport (PVT) method. The zone-refined material and as-grown crystals were characterized by optical microscopy and differential scanning calorimetry (DSC) to reveal the surface morphology, purity and stoichiometry. The results shows that both materials are near-stoichiometric composition, with the purity of the as-grown crystals higher than zone-refined materials. The resistivity of the as-grown crystal (10" Omega-cm) was derived from current-voltage (I-V) measurement, and is 10 times higher than the zone-refined materials. Detail results will be presented and discussed.

Wright, G. W.↗

Tunable-Quantum-Well Infrared Detector

Proposed detector of infrared photons based on photon-assisted, resonant quantum-mechanical tunneling between adjacent energy wells in its semiconductor structure. Wavelength adjusted by changing applied voltage. Device contains alternating layers of different seminconductors which form double-quantum-well electron-energy structure. Tunable-quantum-well detectors made on single chip constitutes line imager. Many such devices stacked to form two-dimensional imaging device. Signal-processing circuitry integrated into chip at its lower end. Potential barriers and wells produced by alternating layers of different semiconductor materials. Steepness of slope proportional to applied electric field. Electric field and thicknesses and heights of barriers selected to favor photon-assisted, resonant quantum-mechanical tunneling at chosen photon frequency.

Maserjian, Joseph↗

Synthesis of CdZnTeSe single crystals for room temperature radiation detector fabrication: mitigation of hole trapping effects using a convolutional neural network

In this article, we report the growth of Cd 0.9 Zn 0.1 Te 0.97 Se 0.03 (CZTS) wide bandgap semiconductor single crystals for room temperature gamma-ray detection using a modified vertical Bridgman method. Charge transport properties measured in the radiation detectors, fabricated from the grown CZTS crystals, indicated signs of hole trapping. Hole traps inhibit high-resolution radiation detection especially for energetic gamma rays. Machine learning (ML) applications are gaining tremendous mpetus in improving device and sensor performance by compensating for limi tations arising from such intrinsic material properties. In this article, we describe a deep convolutional neural network (CNN) that has demonstrated remarkable efficiency in identifying the energy of a gamma photon detected by a CZTS detector. The CNN has been trained using simulated data that resemble output pulses from actual CZTS detectors when exposed to 662-keV gamma photons. The device properties required for the simulation have been derived from radiation detection measurements on a real Cd 0.9 Zn 0.1 Te 0.97 Se 0.03 detector fabricated in our laboratory. The CNN has been trained with detector pulses arising through photoelectric (PE) and Compton scattering (CS) separately. The percentage error in predicting the detected energies, within an extremely small duration of 0.28 ms, was found to be lower than 0.1% for gamma energies above 50 keV and for training datasets con taining PE and CS events separately. The CNN was also validated for a mixed PE and CS dataset to obtain a prediction error of 1%. Additionally, the effect of detector resolution on the efficiency of the CNN was also explored.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing Boron Vacancy Complexes in h-BN Semi-Bulk Crystals Synthesized by Hydride Vapor Phase Epitaxy

Hexagonal BN (h-BN) has emerged as an important ultrawide bandgap (UWBG) semiconductor (Eg~6 eV). The crystal growth technologies for producing semi-bulk crystals/epilayers in large wafer sizes and understanding of defect properties lag decades behind conventional III-nitride wide bandgap (WBG) semiconductors. Here we report probing of boron vacancy (VB)-related defects in freestanding h-BN semi-bulk wafers synthesized by hydride vapor phase epitaxy (HVPE). A photocurrent excitation spectroscopy (PES) was designed to monitor the transport of photoexcited holes from deep-level acceptors. A dominant transition line at 1.66 eV with a side band near 1.62 eV has been directly observed, which matches well with the calculated energy levels of 1.65 for the VB-H deep acceptor in h-BN. The identification of VB complexes via PES measurement was further corroborated by the temperature-dependent dark resistivity and secondary ion mass spectrometry measurements. The results presented here suggested that it is necessary to focus on the optimization of V/III ratio during HVPE growth to minimize the generation of VB-related defects and to improve the overall material quality of h-BN semi-bulk crystals. The work also provided a better understanding of how VB complexes behave and affect the electronic and optical properties of h-BN.

36 MATERIALS SCIENCE↗

Coloring Tetrahedral Semiconductors: Synthesis and Photoluminescence Enhancement of Ternary II-III 2 -VI 4 Colloidal Nanocrystals

Ternary tetrahedral II-III 2 -VI 4 semiconductors, where II is Zn or Cd, III In or Ga, and VI S, Se, or Te, are of interest in UV radiation detectors in medicine and space physics as well as CO 2 photoreduction under visible light. We synthesize colloidal II-III 2 -VI 4 semiconductor nanocrystals from readily available precursors and ascertain their ternary nature by structural and spectroscopic methods, including 77 Se solid-state NMR spectroscopy. The pyramidally shaped nanocrystals range between 2 and 12 nm and exhibit optical gaps of 2–3.9 eV. In the presence of excess anions on the particle surface, treatment with Lewis acidic, Z-type ligands results in better passivation and enhanced photoluminescence. Electronic structure calculations reveal the most stable, lowest energy polymorphs and coloring patterns. This work will pave the way toward more environmentally friendly, ternary semiconductors for optoelectronics and electrocatalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving the method of calculating electronic properties of narrow bandgap semiconductors

A previously developed code for calculating the mobility of charge carriers in narrow bandgap semiconductors does not predict the correct temperature dependence in all cases. It is thought that this is due to the way the electronic screening of the carriers is treated in the model. The objective of this research is to improve the handling of the screening by going beyond the current first Born approximation. Much of this work is directly related to the alloy semiconductor Hg sub 1-xCd sub xTe which is important for infrared detectors and is a good candidate for microgravity crystal growth. The principal conclusion, so far, is that the major difficulty is probably the treatment of short range screening at higher temperatures.

Patterson, James D.↗

Research on radiation detectors, boiling transients, and organic lubricants

The accomplishments of a space projects research facility are presented. The subjects discussed are: (1) a study of radiation resistant semiconductor devices, (2) synthesis of high temperature organic lubricants, (3) departure from phase equilibrium during boiling transients, (4) effects of neutron irradiation on defect state in tungsten, and (5) determination of photon response function of NE-213 liquid scintillation detectors.

Source record↗

The millimeter wave super-Schottky diode detector

The 31 and 92 GHz measurements of the superconductor-Schottky diode extended to millimeter wavelengths by a redesign of the semiconductor interface are reported. Diodes were fabricated by pulse electroplating Pb on 2 x 10 to the 19th/cu cm p-Ga-As etched with HCl; a thin Au overplate is deposited to protect the Pb film from degradation and to improve its lifetime. The noise performance was almost ideal at 31 and 92 GHz; it was concluded that this diode is a quantum-limited-detector at 31 GHz, with excessive parasitic losses at 92 GHz.

Silver, A. H.↗

Lithium source for focused ion beam implantation and analysis

In this work, we present a new Li source for focused ion beam applications. Based on an AuSi eutectic alloy, Li is added as an impurity to minimize effects from degradation when exposed to air. We show the source is stable over the course of an hour and spot sizes ≲10 nm can be achieved. The Li beam can achieve hundreds of nanometer ranges in semiconductors with minimal damage being generated along the path length. The source performance is evaluated through a high-resolution ion beam induced charge collection experiment on an Si-based detector. Further application of the source for ion beam analysis is numerically explored; the example investigated is based on probing a semiconductor heterostructure through a Rutherford backscattering experiment, where the Li beam can reveal information that is inaccessible with either low energy or high energy He projectiles used as probes.

36 MATERIALS SCIENCE↗

Defects of perovskite semiconductor CsPbBr3 investigated via photoluminescence and thermally stimulated current spectroscopies

Halide perovskites are essential materials for hard radiation detectors at ambient temperature. To improve detector performance, charge transport must be investigated and optimized. Using photoluminescence (PL) and thermally stimulated current (TSC) spectroscopies, we investigate photogenerated charge carriers in Bridgman-grown CsPbBr3 single crystals to understand the nature of charge transport. PL spectroscopy of these halide perovskites revealed the presence of strong emission bands at the band edge, which were attributed to free or bound excitons. It is shown that a wide broadening of the excitonic linewidth in these halide perovskites arises from strong exciton–phonon coupling, which is substantially dominated by longitudinal optical phonons via Fröhlich interaction. An additional contribution due to the presence of ionized impurities was also observed. Crystals with a detectable sensitivity to high-energy gamma radiation are characterized by a higher intensity and a narrower linewidth of the principal PL peak at 2.326 eV. Defect states beyond 2.214 eV have a negative impact on detector sensitivity to high-energy gamma radiation. TSC spectroscopy reveals an array of trap levels spanning 0.15–0.70 eV, attributed to intrinsic point defects and multiple extrinsic defects involving dopants or impurities. Defects identified included Cs and Br vacancies, as well as Pb interstitials with concentrations in the 1011–1016 cm−3 range. Understanding how the synthesis process impacts the types and concentrations of the defects present is currently under investigation. Elimination or suppression of the defect/trap states should result in halide perovskite materials with longer carrier diffusion lengths and improved detector characteristics.

Physics↗

Radiation Response of Emerging High Gain, Low Noise Detectors

Data illustrating the radiation response of emerging high gain, low noise detectors are presented. Ionizing dose testing of silicon internal discrete avalanche photodiodes, and 51-MeV proton testing of InGaAs/InAlAs avalanche photodiodes operated in Geiger mode are discussed.

avalanche photodiodes↗