Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Local and Global Sensitivity Analysis of a Reactive Transport Model Simulating Floodplain Redox Cycling

Reactive transport models (RTMs) are essential tools that simulate the coupling of advective, diffusive, and reactive processes in the subsurface, but their complexity makes them difficult to understand, develop and improve without accompanying statistical analyses. Although global sensitivity analysis (SA) can address these issues, the computational cost associated with most global SA techniques limits their use with RTMs. In this study, we apply distance-based generalized sensitivity analysis (DGSA), a novel and computationally efficient method of global SA, to a floodplain-scale RTM and compare DGSA results to those from local SA. Our test case focuses on the impact of 17 uncertain environmental parameters on spatially and temporally variable redox conditions within a floodplain aquifer. The input parameters considered include flow and diffusion rates, geochemical reaction rates, and the spatial distribution of sediment facies. Sensitivity was evaluated for three distinct components of the model response, encompassing both multidimensional and categorical output. Parameter rankings differ between local SA and DGSA, due to nonlinear effects of individual parameters and interaction effects between parameters. DGSA results show that fluid residence time, which is controlled by aquifer permeability, generally exerts a stronger control on redox conditions than do geochemical reaction rates. Sensitivity indices also demonstrate that sulfate reduction is key for establishing and maintaining reducing conditions throughout the aquifer. Furthermore, these results provide insights into the key drivers of heterogeneous redox processes within floodplain aquifers, as well as the main sources of uncertainty when modeling complex subsurface systems.

54 ENVIRONMENTAL SCIENCES↗

Hydropower expansion in eco-sensitive river basins under global energy-economic change

Vast hydropower resources remain untapped globally, the deployment of which could provide energy-economic benefits but impact riverine ecosystems. Across eco-sensitive river basins, it is unclear how drivers of hydropower expansion, such as rapid economic growth and a low-carbon energy transition, could interact with countervailing forces, such as increasingly cost-competitive variable renewable energy (VRE). Using an integrated energy-water-economy model, we explore the effects of these forces on long-term hydropower expansion in the world’s 20 most eco-sensitive basins, which have high ecological richness and untapped hydropower potential. Here, we find that a low-carbon transition exerts the strongest development pressure, causing deployment exceeding 80% of exploitable potential in more than 72% of eco-sensitive basins by 2050, most of which have limited deployment today. Rapid economic growth induces such extensive deployment in only 44% of eco-sensitive basins. Enhanced integration of VRE reduces deployment, alleviating the impacts of rapid economic growth but not the low-carbon transition.

13 HYDRO ENERGY↗

Electrospun porous La–Sr–Co–Ni–O nanofibers for highly sensitive non-enzymatic glucose detection

Glucose biosensors are widely used for clinical, industrial, and environmental applications. Nonenzymatic electrochemical glucose biosensors based on metal oxides with a perovskite structure have exhibited high sensitivity, excellent stability, and cost efficiency. In this work, porous La–Sr–Co–Ni–O (LSCNO) nanofibers, with an ABO 3 -type perovskite structure, were prepared through optimizing the A-site and B-site elements by electrospinning, followed with calcination at 700 °C for 5 h. Characterized by scanning and transmission electron microscopy, X-ray diffraction, and X-ray photoelectron spectroscopy, fabricated nanofibers were confirmed to be porous and nanosized polycrystalline grains with high crystallinity. A novel La 0.75 Sr 0.25 Co 0.5 Ni 0.5 O 3 -based nonenzymatic electrochemical biosensor was developed, which is sensitive to glucose because of an electrochemically catalytic mechanism, a mediated electron transfer involving Ni(II)/Ni(III) or Co(II)/Co(III), accompanying with gluconic acid complexation. The glucose biosensor presented a linear response in the range of 0.1–1.0 mM with a calibration sensitivity of 924 ± 28 μA mM –1 , a proportion of the variance of 0.9926, and a lower limit of detection of 0.083 mM, respectively, demonstrating an outstanding analytical performance. The biosensor showed no response to the most widely used anionic surfactant, sodium dodecyl sulfate, and low sensitivity to other biomolecules, such as fructose, lactose, galactose, mannose, dopamine, and ascorbic acid. A urine sample was tested by this novel nonenzymatic electrochemical biosensor by standard addition method, suggesting a potential application for clinical test.

36 MATERIALS SCIENCE↗

Can a shock-induced phonon up-pumping model relate to impact sensitivity of molecular crystals, polymorphs and cocrystals?

Impact sensitivity engineering of high-energy molecular crystals requires accurate predictive models. For this purpose, the promising multi-phonon based approach is selected, assessing a bit more its strengths and weaknesses. Presently used with high-quality phonon calculations of 22 molecular crystals, using a physics-based criterion to determine the phonon bath extent, the resulting intrinsic shock sensitivity index (SSI) is compared to the most common marker of impact sensitivity, h 50 , as determined from drop-weight impact tests. Selecting a data subset from experiments performed under very similar conditions (2.5 kg hammer with grit and 30–40 mg samples), the model can predict h 50 values for mono-molecular crystals with very good accuracy, including the ability to discriminate the polymorphs of HMX and CL20. This very good agreement validates an initial indirect up-pumping mechanism occurring under these conditions, where the doorway modes also interact with the phonon bath. However, the phonon bath criterion for mono-molecular crystals does not transfer well to cocrystals. Owing to the vibrational coupling of the co-molecules, it seems a broader phonon bath should be considered. Additionally recalling experimental uncertainty and various experimental factors affecting h 50 values for a given compounds, we recommend that the density of the sample, granularity and morphology be systematically considered and reported along with measurements, which will in turn allow for more systematic data and predictive capabilities for sensitivity models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A portable and reusable sensor system based on graphene for real-time and sensitive detection of lead ions in water

Long-term exposure to Pb 2+ can cause irreversible damage to the nervous, cardiovascular, and reproductive systems. Therefore, developing a fast and sensitive detection system capable of monitoring minuscule concentrations of Pb 2+ is essential. In this study, we demonstrated a fully portable sensor system enabling rapid, sensitive, and real-time monitoring of Pb 2+ . The sensor system adopted the remote-gate field-effect transistor (RGFET) detection scheme and was easy to operate, even for non-experts. The sensor system comprised two printed circuit boards (PCBs): a sensor PCB with a remote-gate electrode and an analyzer PCB with a metal-oxide-semiconductor field-effect transistor (MOSFET) transducer and peripheral electronics to manage sensor signals. To achieve a high sensitivity for Pb 2+ , we utilized graphene ink drop-casted on the sensor PCB as a sensing membrane. The graphene film was easy to deposit and remove, enabling the sensor PCB to be reused multiple times. The sensor system was further linked to a smartphone application that instantly monitors the sensor response, allowing for rapid point-of-use detection. The sensor exhibited a high sensitivity of 21.7% when the limit of detection (LOD) value of 1 nM (∼0.2 ppb) was detected, and the typical detection time for each sample was approximately 60 seconds. This portable sensor system advances sensing technologies and could potentially supplement expensive, laborious conventional sensing equipment.

54 ENVIRONMENTAL SCIENCES↗

Prediction of impact sensitivity, heat of formation and heat of explosion using atomic connectivity

In these proceedings we revisit a large collection of explosives and explosive descriptors with the goal of predicting impact sensitivity using only local atomic environments that can be deciphered from molecular SMILES strings as descriptors without utilizing empirically measured values or computationally expensive electronic structure calculations. From the original database of nearly 500 descriptors, removing empirically measured and electronic structure values decreased the number of descriptors to 135, which we reduced to 18 the most important descriptors using Random Forests. The condensed model predicted impact sensitivity with essentially the same accuracy as the existing, more complex model (R 2 = 0.788 and RSME = 0.312), while remaining applicable to all types of explosives (Peroxides, azides, C-Nitros, Nitroamines, Nitrate Esters, etc.). In addition to impact sensitivity, we proposed similar models to accurately predict values heat of formation (ΔH f ) and heat of explosion (Q), with R 2 = 0.966 and 0.916, respectively. In conclusion, the work in these proceedings allows for prediction of explosive performance and sensitivity with only chemical structure information and an estimate of density.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A robust high sensitivity scanning thermal probe for simultaneous microscale thermal and thermoelectric property mapping

Scanning Thermal Microscopy (SThM) provides efficient thermal property measurement with micro- or nanoscale spatial resolution. However, the sensitivity and accuracy of state-of-the-art thermal probes have been limited by excessive thermal contact resistance between the probe and sample. Introduced herein is a robust thermal microprobe that can increase the probe-sample contact force by more than two orders of magnitude, thereby reducing the probe-sample thermal contact resistance by as much as 96% and increasing measurement sensitivity by more than 240% compared to a commercial thermal probe with the same dimensions and measurement principle. The relationship between the probe-sample thermal contact resistance, thermal exchange radius, and sample thermal conductivity is determined experimentally. Simultaneous measurement of thermal conductivity and Seebeck coefficient with unprecedented sensitivity is demonstrated using the enhanced scanning thermal microprobe on samples of an extended range of thermal conductivity up to 18 W/m K, increasing the range of samples applicable to SThM when compared to the conventional commercial probe with diminished measurement sensitivity above ~10 W/m K. The probe is further demonstrated by simultaneously mapping thermal conductivity and Seebeck coefficient as a function of depth from the irradiated surface of an ion-irradiated bulk nanostructured thermoelectric material. In addition to enabling microscale thermal conductivity and Seebeck coefficient measurement of materials previously not applicable to SThM, the probe can also facilitate high-throughput characterization of combinatorial materials to aid the rapid discovery of compositions and processing conditions that yield highly desired thermal and thermoelectric properties.

36 MATERIALS SCIENCE↗

Electric field sensitivity of molecular color centers

Molecular color centers with S=1 ground states are promising candidates for quantum sensing of electric fields. These molecules have an electronic structure similar to solid state color centers, but they allow for processing modalities that permit direct interfacing with an analyte. Currently, it is unknown how sensitive these molecules are to electric fields and what molecular properties affect their sensitivity. We perform density functional theory calculations to understand the impact of electric fields on the electronic structure of five nominally tetrahedral molecular color centers exhibiting variable transition metal chemistry and ligand densities. We then extract the Stark parameters from each of these molecules and compare them to molecular properties such as the dipole moment and inner shell stiffness and find that the dipole moment of the molecule largely governs sensitivity. We predict that polar heteroleptic molecules may have electric field sensitivities comparable to solid state color centers such as nitrogen-vacancy centers in diamond.

Physics↗

New high-sensitivity searches for neutrons converting into antineutrons and/or sterile neutrons at the HIBEAM/NNBAR experiment at the European Spallation Source

The violation of baryon number, , is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the Universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR program is a proposed two-stage experiment at the European Spallation Source to search for baryon number violation. The program will include high-sensitivity searches for processes that violate baryon number by one or two units: free neutron–antineutron oscillation () via mixing, neutron–antineutron oscillation via regeneration from a sterile neutron state (), and neutron disappearance (n → n′); the effective process of neutron regeneration () is also possible. The program can be used to discover and characterize mixing in the neutron, antineutron and sterile neutron sectors. The experiment addresses topical open questions such as the origins of baryogenesis and the nature of dark matter, and is sensitive to scales of new physics substantially in excess of those available at colliders. A goal of the program is to open a discovery window to neutron conversion probabilities (sensitivities) by up to three orders of magnitude compared with previous searches. The opportunity to make such a leap in sensitivity tests should not be squandered. The experiment pulls together a diverse international team of physicists from the particle (collider and low energy) and nuclear physics communities, while also including specialists in neutronics and magnetics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing spin dressing sensitivity for the nEDMSF experiment

nEDMSF aims to measure the neutron electric dipole moment (d n ) with unprecedented precision. In this paper we explore the experiment's sensitivity when operating with an implementation of the critical dressing method in which the angle between the neutron and Helium-3 spins (ϕ 3n ) is subjected to a square modulation by an amount ϕ d (the “dressing angle”). Several parameters can be tuned to optimize sensitivity. We find roughly 10% improvement over a previous estimate, resulting primarily from the addition of a waiting period between the π/2 pulse that initiates d n -driven ϕ 3n growth and the start of ϕ3n modulation. We find negligible further improvement by allowing ϕ d to vary continuously over the course of a run, and no degradation resulting from the addition of an in situ background measurement into each ϕ3n modulation sequence. A complete simulation confirms a 300 live-day sensitivity ofσ = 1.45×10 -28 e ·cm. At this level of sensitivity, σ ϕ3n0 = 1 mrad precision on the initial n/ 3 He angle difference is not negligible.

47 OTHER INSTRUMENTATION↗

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators↗

Sensitivity Analysis of Genome-Scale Metabolic Flux Prediction

TRIMER, Transcription Regulation Integrated with MEtabolic Regulation, is a genome-scale modeling pipeline targeting at metabolic engineering applications. Using TRIMER, regulated metabolic reactions can be effectively predicted by integrative modeling of metabolic reactions with a Transcription Factor (TF)-gene regulatory network (TRN), which is modeled via a Bayesian network (BN). In this paper, we focus on sensitivity analysis of metabolic flux prediction for uncertainty quantification of BN structures for TRN modeling in TRIMER. We propose a computational strategy to construct the uncertainty class of TRN models based on the inferred regulatory order uncertainty given transcriptomic expression data. With that, we analyze the prediction sensitivity of the TRIMER pipeline for the metabolite yields of interest. The obtained sensitivity analyses can guide Optimal Experimental Design (OED) to help acquire new data that can enhance TRN modeling and achieve specific metabolic engineering objectives, including metabolite yield alterations. Here we have performed small- and large-scale simulated experiments, demonstrating the effectiveness of our developed sensitivity analysis strategy for BN structure learning to quantify the edge importance in terms of metabolic flux prediction uncertainty reduction and its potential to effectively guide OED.

59 BASIC BIOLOGICAL SCIENCES↗

Analytical Voltage Sensitivity Analysis for Unbalanced Power Distribution System

Large scale integration of distributed energy resources and electric vehicles in a transactive energy environment present new challenges in terms of voltage stability and fluctuations in a power distribution system. The impact of different level of DER/EV penetration on the voltages across the network is typically quantified through voltage sensitivity analyses. Existing methods of voltage sensitivity analysis are computationally expensive and prior efforts to develop analytical approximation lacks generality and have not been effectively validated. The objective of this work is to provide a new analytical method of voltage sensitivity analysis that has low computational cost and also allows for stochastic analysis of voltage change. This paper first derives an analytical approximation of change in voltage at a particular bus due to change in power consumption at other bus in a radial three phase unbalanced power distribution system. Then, the proposed method is shown to be valid for different load configurations, which demonstrates its generality. The results from our analytical approach is validated via classical load flow simulation of the test system based on IEEE 37 bus network. The proposed method is shown to have good accuracy, and computation complexity is of order O(1), compared to O(n3) in classical sensitivity analysis approaches.

Munikoti, Sai↗

A Comparative Study of the Perceptual Sensitivity of Topological Visualizations to Feature Variations

Color maps are a commonly used visualization technique in which data are mapped to optical properties, e.g., color or opacity. Color maps, however, do not explicitly convey structures (e.g., positions and scale of features) within data. Topology-based visualizations reveal and explicitly communicate structures underlying data. Although our understanding of what types of features are captured by topological visualizations is good, our understanding of people's perception of those features is not. Further, this paper evaluates the sensitivity of topology-based isocontour, Reeb graph, and persistence diagram visualizations compared to a reference color map visualization for synthetically generated scalar fields on 2-manifold triangular meshes embedded in 3D. In particular, we built and ran a human-subject study that evaluated the perception of data features characterized by Gaussian signals and measured how effectively each visualization technique portrays variations of data features arising from the position and amplitude variation of a mixture of Gaussians. For positional feature variations, the results showed that only the Reeb graph visualization had high sensitivity. For amplitude feature variations, persistence diagrams and color maps demonstrated the highest sensitivity, whereas isocontours showed only weak sensitivity. These results take an important step toward understanding which topology-based tools are best for various data and task scenarios and their effectiveness in conveying topological variations as compared to conventional color mapping.

97 MATHEMATICS AND COMPUTING↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Freestanding VO 2 membranes on epidermal nanomesh for ultra-sensitive correlated breathable sensors

The interest in highly sensitive sensors is rapidly increasing for detecting very tiny signals for Internet of Things devices. Here, we achieve ultra-sensitive correlated breathable sensors based on freestanding VO 2 membranes. We fabricate the membranes by growing VO 2 films onto sacrificial Sr 3 Al 2 O 6 layer grown on SrTiO 3 , selectively dissolving the Sr 3 Al 2 O 6 in water, and then rendering freestanding VO 2 membrane on nanomesh. The nanomeshes are extremely flexible, sweat permeable, and readily skin-adhesive. The resistance of the VO 2 membranes is reversibly tuned by human’s tiny mechanical stimuli and breath stimuli. The stimuli modulate the Peierls dimerization of one-dimensional V-V chains in the VO 2 lattice which concomitantly controls the electron correlation and hence resistivity. Since our breathable sensors operate based on quantum-mechanical correlation effects, their sensitivity is 1-2 orders of magnitude higher than conventional tactile and respiratory sensors based on other materials. Thus, the freestanding membranes of correlated oxides on epidermal nanomeshes are multifunctional platforms for developing ultra-sensitive correlated breathable sensors.

36 MATERIALS SCIENCE↗

Odor exposure during imprinting periods increases odorant-specific sensitivity and receptor gene expression in coho salmon ( Oncorhynchus kisutch )

ABSTRACT Pacific salmon are well known for their homing migrations; juvenile salmon learn odors associated with their natal streams prior to seaward migration, and then use these retained odor memories to guide them back from oceanic feeding grounds to their river of origin to spawn several years later. This memory formation, termed olfactory imprinting, involves (at least in part) sensitization of the peripheral olfactory epithelium to specific odorants. We hypothesized that this change in peripheral sensitivity is due to exposure-dependent increases in the expression of odorant receptor (OR) proteins that are activated by specific odorants experienced during imprinting. To test this hypothesis, we exposed juvenile coho salmon, Oncorhynchus kisutch, to the basic amino acid odorant l-arginine during the parr–smolt transformation (PST), when imprinting occurs, and assessed sensitivity of the olfactory epithelium to this and other odorants. We then identified the coho salmon ortholog of a basic amino acid odorant receptor (BAAR) and determined the mRNA expression levels of this receptor and other transcripts representing different classes of OR families. Exposure to l-arginine during the PST resulted in increased sensitivity to that odorant and a specific increase in BAAR mRNA expression in the olfactory epithelium relative to other ORs. These results suggest that specific increases in ORs activated during imprinting may be an important component of home stream memory formation and this phenomenon may ultimately be useful as a marker of successful imprinting to assess management strategies and hatchery practices that may influence straying in salmon.

Dittman, Andrew H. (ORCID:000000016482359X)↗

Sensitivity analysis of homogenized cross section in AP1000 lattices

The two-step method for light water reactor simulation consists of performing lattice-level calculations to determine homogenized properties of the lattice for a variety of configurations and burnups then performing a core-level calculation which relies on those pre-calculated lattice properties. Calculating the homogenized lattice properties for the specific conditions needed in the core-level calculation relies on interpolating from the pre-calculated lattice properties. Although many studies have explored different models that can be used for this interpolation, there is a need to explore how to appropriately parameterize the lattice for those interpolation models. The present study uses linear sensitivity methods to determine the sensitivity of homogenized cross sections to both instantaneous and historical values of state variables. The results from this study can be used to inform parameterizations which more appropriately capture history effects in homogenized cross section interpolation. Two different lattices are used for this analysis from the AP1000 reactor, one includes burnable absorbers. It was found that early in the cycle, the historical values of state variables have little effect on the instantaneous value of the homogenized cross sections explored here - especially in the case of the lattice containing burnable absorbers. However, it was found that later in the cycle, the thermal fission homogenized cross section was sensitive to the historic states of the lattice. In fact, using the average of a state variable as a predictor for interpolation models may be insufficient for capturing historic effects due to more recent states having larger sensitivity measures than less recent states. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗