Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Two-photon-induced x-ray emission in neon atoms

We investigated the resonant x-ray emission from a neon atom induced by the two-photon population of a double-core-hole excited state. Two qualitatively different schemes of this process are studied: The first one involves an off-resonant intermediate single-core-hole state; the second scheme passes through a resonant core-ionized intermediate state. The numerical simulations of the resonant x-ray emission performed for different peak intensities and pulse durations show significant population of the double-core-hole final states. Therefore, rather strong two-photon absorption-induced x-ray emission is predicted for both studied schemes. Thus, high counting rates in experimental measurements are expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in Small Animal Imaging Systems

The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to an increased interest in in vivo laboratory animal imaging during the past few years. For this purpose, new instrumentation, data acquisition strategies, and image processing and reconstruction techniques are being developed, researched and evaluated. The aim of this article is to give a short overview of the state of the art technologies for high resolution and high sensitivity molecular imaging techniques, primarily positron emission tomography (PET) and single photon emission computed tomography (SPECT). The basic needs of small animal imaging will be described. The evolution in instrumentation in the past two decades, as well as the commercially available systems will be overviewed. Finally, the new trends in detector technology and preliminary results from challenging applications will be presented. For more details a number of references are provided.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Triangular cross-section beam splitters in silicon carbide for quantum information processing

Abstract Triangular cross-section color center photonics in silicon carbide is a leading candidate for scalable implementation of quantum hardware. Within this geometry, we model low-loss beam splitters for applications in key quantum optical operations such as entanglement and single-photon interferometry. We consider triangular cross-section single-mode waveguides for the design of a directional coupler. We optimize parameters for a 50:50 beam splitter. Finally, we test the experimental feasibility of the designs by fabricating triangular waveguides in an ion beam etching process and identify suitable designs for short-term implementation.

42 ENGINEERING↗

Spin-orbit–coupled exciton-polariton condensates in lead halide perovskites

Spin-orbit coupling (SOC) is responsible for a range of spintronic and topological processes in condensed matter. Here, we show photonic analogs of SOCs in exciton-polaritons and their condensates in microcavities composed of birefringent lead halide perovskite single crystals. The presence of crystalline anisotropy coupled with splitting in the optical cavity of the transverse electric and transverse magnetic modes gives rise to a non-Abelian gauge field, which can be described by the Rashba-Dresselhaus Hamiltonian near the degenerate points of the two polarization modes. With increasing density, the exciton-polaritons with pseudospin textures undergo phase transitions to competing condensates with orthogonal polarizations. Unlike their pure photonic counterparts, these exciton-polaritons and condensates inherit nonlinearity from their excitonic components and may serve as quantum simulators of many-body SOC processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging in Diagnostic Nuclear Medicine

Single-photon emission computed tomography (SPECT) and positron emission tomography (PET) are modern methods for visualization in diagnostic nuclear medicine. SPECT is known as a workhorse in cardiology, and PET is the gold standard in oncology. The development of nuclear medicine is provided by cooperation of physicists, mathematicians, biologists, medical doctors, and radio-chemists. In spite of extensive clinical applications, several problems may lead to false diagnoses. In particular, the correction of attenuation of gamma radiation in human organs must be taken into account. For interpretation and evaluation of such an effect on the clinical results, we perform physico-mathematical simulation of the SPECT diagnostics in cardiology in the absence and presence of the correction of attenuation. A brief review of the state-of-the art is presented. The simulation employs the first Russian anthropomorphic mathematical phantom that describes the distribution of radio-pharmacological agent ({sup 99m }Tc-methoxyisobutylisonitrile) in chest organs of a typical male patient. A model for calculation of raw images is developed with allowance for attenuation of radiation in biological tissues and the effect of collimator and detector. The results of the proposed models and calculated images are compared with clinical images obtained at the Meshalkin Institute of Circulation Pathology (Novosibirsk) and Myasnikov Institute of Clinical Cardiology (Moscow). Statistical algorithms are developed for the solution of the inverse problem of image reconstruction based on the entropy principle. The clinical and physico-mathematical approaches are compared in the evaluation of the effect of correction on the quality of reconstructed images of the left ventricle of myocardium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Results of a New Deterministic Iterative Image Reconstruction Algorithm - Paper 117

Iterative reconstruction techniques have become the standard for Single Photon Emission Computed Tomography (SPECT). Advances in computing have allowed these techniques to incorporate more and more detail; however, computation time must be balanced against increased detail. Monte Carlo methods are generally used for modeling the physics of a SPECT study, but can have long computation times. Advances in Monte Carlo-based scatter correction have shown reasonable results, but scatter estimation by measuring narrow energy windows remains more common. An iterative reconstruction technique using a deterministic transport code has been proposed as an alternative. This paper presents preliminary results of the new technique in which the TITAN deterministic code completes the forward projection step in a maximum likelihood expectation maximization (ML-EM) reconstruction of SPECT data. The effectiveness of the deterministic algorithm is examined for a 2-dimensional phantom. This work demonstrates the feasibility of using the TITAN code in an iterative reconstruction algorithm. The appropriate deterministic parameters were chosen by comparing sinograms produced with different mesh sizes, quadrature sets, and anisotropic scattering orders. The TITAN code was then successfully used as the forward projection step in an iterative reconstruction algorithm with a 2-dimensional homogeneous phantom. The impact of deterministic parameters on reconstruction quality is being investigated, along with the incorporation of a smoothing filter. The TITAN source code is being modified to include the ML-EM algorithm and iteration steps. This will significantly improve computation time by eliminating the repeated reading and writing of files for each iteration and allowing some steps to be completed in parallel. Further testing of the new reconstruction algorithm for more realistic phantoms is also underway. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Advances in the photon avalanche luminescence of inorganic lanthanide-doped nanomaterials

Photon avalanche (PA)—where the absorption of a single photon initiates a ‘chain reaction’ of additional absorption and energy transfer events within a material—is a highly nonlinear optical process that results in upconverted light emission with an exceptionally steep dependence on the illumination intensity. Over 40 years following the first demonstration of photon avalanche emission in lanthanide-doped bulk crystals, PA emission has been achieved in nanometer-scale colloidal particles. The scaling of PA to nanomaterials has resulted in significant and rapid advances, such as luminescence imaging beyond the diffraction limit of light, optical thermometry and force sensing with (sub)micron spatial resolution, and all-optical data storage and processing. In this review, we discuss the fundamental principles underpinning PA and survey the studies leading to the development of nanoscale PA. Finally, we offer a perspective on how this knowledge can be used for the development of next-generation PA nanomaterials optimized for a broad range of applications, including mid-IR imaging, luminescence thermometry, (bio)sensing, optical data processing and nanophotonics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fault tolerant filtering and fault detection for quantum systems driven by fields in single photon states

The purpose of this paper is to solve the fault tolerant filtering and fault detection problem for a class of open quantum systems driven by a continuous-mode bosonic input field in single photon states when the systems are subject to stochastic faults. Optimal estimates of both the system observables and the fault process are simultaneously calculated and characterized by a set of coupled recursive quantum stochastic differential equations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PHOTON-INDUCED FORMATION OF MOLECULAR HYDROGEN FROM A NEUTRAL POLYCYCLIC AROMATIC HYDROCARBON: 9,10-DIHYDROANTHRACENE

Experimental results from infrared spectroscopy and mass spectrometry provide compelling evidence that UV irradiation of the neutral polycyclic aromatic hydrocarbon (PAH) 9,10-dihydroanthracene (DHA), trapped in solid argon (12 K), results in efficient (i.e., 90% yield) conversion to anthracene and molecular hydrogen. A number of dissociation pathways involving single or double hydrogen loss are investigated computationally. Among these, two mechanisms are most credible for a one-photon dissociation process involving UV photons <5.5 eV. For the lowest-energy pathway (2.3 eV), a simultaneous lengthening of the C-H bonds of H9 and H10 gives rise to an anthracene-H{sub 2} complex. A higher-energy mechanism (3.4 eV) involves an initial lengthening of the H9 C-H bond, followed by this hydrogen 'grabbing' H10, and forming H{sub 2}. The high yield of this photolysis reaction suggests that similar reactions may take place for other neutral PAHs, with implications for the formation of molecular hydrogen in regions of low UV exposure, such as in dark clouds.

79 ASTRONOMY AND ASTROPHYSICS↗

HiSPoD : a program for high-speed polychromatic X-ray diffraction experiments and data analysis on polycrystalline samples

Here, a high-speed X-ray diffraction technique was recently developed at the 32-ID-B beamline of the Advanced Photon Source for studying highly dynamic, yet non-repeatable and irreversible, materials processes. In experiments, the microstructure evolution in a single material event is probed by recording a series of diffraction patterns with extremely short exposure time and high frame rate. Owing to the limited flux in a short pulse and the polychromatic nature of the incident X-rays, analysis of the diffraction data is challenging. Here, HiSPoD , a stand-alone Matlab-based software for analyzing the polychromatic X-ray diffraction data from polycrystalline samples, is described. With HiSPoD , researchers are able to perform diffraction peak indexing, extraction of one-dimensional intensity profiles by integrating a two-dimensional diffraction pattern, and, more importantly, quantitative numerical simulations to obtain precise sample structure information.

36 MATERIALS SCIENCE↗

Phantom experiments to improve parathyroid lesion detection

This investigation tested the hypothesis that visual analysis of iteratively reconstructed tomograms by ordered subset expectation maximization (OSEM) provides the highest accuracy for localizing parathyroid lesions using {sup 99m}Tc-sestamibi SPECT data. From an Institutional Review Board approved retrospective review of 531 patients evaluated for parathyroid localization, image characteristics were determined for 85 {sup 99m}Tc-sestamibi SPECT studies originally read as equivocal (EQ). Seventy-two plexiglas phantoms using cylindrical simulated lesions were acquired for a clinically realistic range of counts (mean simulated lesion counts of 75{+-}50 counts/pixel) and target-to-background (T:B) ratios (range=2.0 to 8.0) to determine an optimal filter for OSEM. Two experienced nuclear physicians graded simulated lesions, blinded to whether chambers contained radioactivity or plain water, and two observers used the same scale to read all phantom and clinical SPECT studies, blinded to pathology findings and clinical information. For phantom data and all clinical data, T:B analyses were not statistically different for OSEM versus FB, but visual readings were significantly more accurate than T:B (88{+-}6% versus 68{+-}6%, p=0.001) for OSEM processing, and OSEM was significantly more accurate than FB for visual readings (88{+-}6% versus 58{+-}6%, p<0.0001). These data suggest that visual analysis of iteratively reconstructed MIBI tomograms should be incorporated into imaging protocols performed to localize parathyroid lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of quantitative imaging methods for organ activity and residence time estimation using a population of phantoms having realistic variations in anatomy and uptake

Estimating organ residence times is an essential part of patient-specific dosimetry for radioimmunotherapy (RIT). Quantitative imaging methods for RIT are often evaluated using a single physical or simulated phantom but are intended to be applied clinically where there is variability in patient anatomy, biodistribution, and biokinetics. To provide a more relevant evaluation, the authors have thus developed a population of phantoms with realistic variations in these factors and applied it to the evaluation of quantitative imaging methods both to find the best method and to demonstrate the effects of these variations. Using whole body scans and SPECT/CT images, organ shapes and time-activity curves of 111In ibritumomab tiuxetan were measured in dosimetrically important organs in seven patients undergoing a high dose therapy regimen. Based on these measurements, we created a 3D NURBS-based cardiac-torso (NCAT)-based phantom population. SPECT and planar data at realistic count levels were then simulated using previously validated Monte Carlo simulation tools. The projections from the population were used to evaluate the accuracy and variation in accuracy of residence time estimation methods that used a time series of SPECT and planar scans. Quantitative SPECT (QSPECT) reconstruction methods were used that compensated for attenuation, scatter, and the collimator-detector response. Planar images were processed with a conventional (CPlanar) method that used geometric mean attenuation and triple-energy window scatter compensation and a quantitative planar (QPlanar) processing method that used model-based compensation for image degrading effects. Residence times were estimated from activity estimates made at each of five time points. The authors also evaluated hybrid methods that used CPlanar or QPlanar time-activity curves rescaled to the activity estimated from a single QSPECT image. The methods were evaluated in terms of mean relative error and standard deviation of the relative error in the residence time estimates taken over the phantom population. The mean errors in the residence time estimates over all the organs were <9.9% (pure QSPECT), <13.2% (pure QPLanar), <7.2% (hybrid QPlanar/QSPECT), <19.2% (hybrid CPlanar/QSPECT), and 7%-159% (pure CPlanar). The standard deviations of the errors for all the organs over all the phantoms were <9.9%, <11.9%, <10.8%, <22.0%, and <107.9% for the same methods, respectively. The processing methods differed both in terms of their average accuracy and the variation of the accuracy over the population of phantoms, thus demonstrating the importance of using a phantom population in evaluating quantitative imaging methods. Hybrid CPlanar/QSPECT provided improved accuracy compared to pure CPlanar and required the addition of only a single SPECT acquisition. The QPlanar or hybrid QPlanar/QSPECT methods had mean errors and standard deviations of errors that approached those of pure QSPECT while providing simplified image acquisition protocols, and thus may be more clinically practical.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design and assessment of a novel SPECT system for desktop open-gantry imaging of small animals: A simulation study

Purpose: Given increasing efforts in biomedical research utilizing molecular imaging methods, development of dedicated high-performance small-animal SPECT systems has been growing rapidly in the last decade. In the present work, we propose and assess an alternative concept for SPECT imaging enabling desktop open-gantry imaging of small animals. Methods: The system, PERSPECT, consists of an imaging desk, with a set of tilted detector and pinhole collimator placed beneath it. The object to be imaged is simply placed on the desk. Monte Carlo (MC) and analytical simulations were utilized to accurately model and evaluate the proposed concept and design. Furthermore, a dedicated image reconstruction algorithm, finite-aperture-based circular projections (FABCP), was developed and validated for the system, enabling more accurate modeling of the system and higher quality reconstructed images. Image quality was quantified as a function of different tilt angles in the acquisition and number of iterations in the reconstruction algorithm. Furthermore, more complex phantoms including Derenzo, Defrise, and mouse whole body were simulated and studied. Results: The sensitivity of the PERSPECT was 207 cps/MBq. It was quantitatively demonstrated that for a tilt angle of 30°, comparable image qualities were obtained in terms of normalized squared error, contrast, uniformity, noise, and spatial resolution measurements, the latter at ∼0.6 mm. Furthermore, quantitative analyses demonstrated that 3 iterations of FABCP image reconstruction (16 subsets/iteration) led to optimally reconstructed images. Conclusions: The PERSPECT, using a novel imaging protocol, can achieve comparable image quality performance in comparison with a conventional pinhole SPECT with the same configuration. The dedicated FABCP algorithm, which was developed for reconstruction of data from the PERSPECT system, can produce high quality images for small-animal imaging via accurate modeling of the system as incorporated in the forward- and back-projection steps. Meanwhile, the developed MC model and the analytical simulator of the system can be applied for further studies on development and evaluation of the system.

60 APPLIED LIFE SCIENCES↗

Fast quantum ghost imaging with a single-photon-sensitive time-stamping camera

Quantum ghost imaging (QGI) leverages correlations between entangled photon pairs to reconstruct an image using light that has never physically interacted with an object. Despite extensive research interest, this technique has long been hindered by slow acquisition speeds, due to the use of raster-scanned detectors or the slow response of intensified cameras. Here, we utilize a single-photon-sensitive time-stamping camera to perform QGI at ultra-low-light levels with rapid data acquisition and processing times, achieving high-resolution and high-contrast images in under 1 min. Our work addresses the trade-off between image quality, optical power, data acquisition time, and data processing time in QGI, paving the way for practical applications in biomedical and quantum-secured imaging.

Mavian, Alex (ORCID:0000000279448830)↗

Quantum-enhanced photoprotection in neuroprotein architectures emerges from collective light-matter interactions

Background Superradiance is the phenomenon of many identical quantum systems absorbing and/or emitting photons collectively at a higher rate than any one system can individually. This phenomenon has been studied analytically in idealized distributions of electronic two-level systems (TLSs), each with a ground and excited state, as well as numerically in realistic photosynthetic nanotubes and cytoskeletal architectures. Methods Superradiant effects are studied here in idealized toy model systems and realistic biological mega-networks of tryptophan (Trp) molecules, which are strongly fluorescent amino acids found in many proteins. Each Trp molecule acts as a chromophore absorbing in the ultraviolet spectrum and can be treated approximately as a TLS, with its 1 L a excited singlet state; thus, organized Trp networks can exhibit superradiance. Such networks are found, for example, in microtubules, actin filaments, and amyloid fibrils. Microtubules and actin filaments are spiral-cylindrical protein polymers that play significant biological roles as primary constituents of the eukaryotic cytoskeleton, while amyloid fibrils have been targeted in a variety of neurodegenerative diseases. We treat these proteinaceous Trp networks as open quantum systems, using a non-Hermitian Hamiltonian to describe interactions of the chromophore network with the electromagnetic field. We numerically diagonalize the Hamiltonian to obtain its complex eigenvalues, where the real part is the energy and the imaginary part is its associated enhancement rate. We also consider multiple realizations of increasing static disorder in either the site energies or the decay rates. Results We obtained the energies and enhancement rates for realistic microtubules, actin filament bundles, and amyloid fibrils of differing lengths, and we use these values to calculate the quantum yield, which is the ratio of the number of photons emitted to the number of photons absorbed. We find that all three of these structures exhibit highly superradiant states near the low-energy portion of the spectrum, which enhances the magnitude and robustness of the quantum yield to static disorder and thermal noise. Conclusion The high quantum yield and stable superradiant states in these biological architectures may play a photoprotective rolein vivo, downconverting energetic ultraviolet photons—absorbed from those emitted by reactive free radical species—to longer, safer wavelengths and thereby mitigating biochemical stress and photophysical damage. Contrary to conventional assumptions that quantum effects cannot survive in large biosystems at high temperatures, our results suggest that macropolymeric collectives of TLSs in microtubules, actin filaments, and amyloid fibrils exhibit increasingly observable and robust effects with increasing length, up to the micron scale, due to quantum coherent interactions in the single-photon limit. Superradiant enhancement and high quantum yield exhibited in neuroprotein polymers could thus play a crucial role in information processing in the brain, the development of neurodegenerative diseases such as Alzheimer’s and related dementias, and a wide array of other pathologies characterized by anomalous protein aggregates.

Physics↗

Ultralow Energy Electron Attachment at Sub-Millielectron Volt Resolution

The technique of rare-gas photoionization has been extended by use of direct laser ionization to electron energies epsilon in the range 0-100 meV, with a resolution Delta(epsilon) of 0.4-0.5 meV (FWHM). Tunable UV light at (Lambda)276 nm is produced using a pulsed Nd:YAG laser and nonlinear mixing techniques. The beam is frequency tripled in a pulsed jet of xenon. The VUV radiation, tunable at (Lambda)92 nm, is then used to photoionize Xe at its 2P(sub 1/2) threshold (single-photon ionization). The photoelectrons produced interact with admixed target gas to generate negative ions through the s-wave capture process. Recent results in electron attachment to SF(sub 6) will be reported which show resonance structure at the opening of the ground-state vibrational channels. This structure corresponds to the process of vibrational excitation + attachment, which is superimposed on the underlying s-wave (direct) capture process. It should be a general phenomenon, present in a wide variety of zero-energy electron attaching molecules.

Chutjian, A.↗

Efficient Source of Shaped Single Photons Based on an Integrated Diamond Nanophotonic System

An efficient, scalable source of shaped single photons that can be directly integrated with optical fiber networks and quantum memories is at the heart of many protocols in quantum information science. We demonstrate a deterministic source of arbitrarily temporally shaped single-photon pulses with high efficiency [detection efficiency = 14.9 %] and purity [g (2) (0) = 0.0168] and streams of up to 11 consecutively detected single photons using a silicon-vacancy center in a highly directional fiber-integrated diamond nanophotonic cavity. Finally, combined with previously demonstrated spin-photon entangling gates, this system enables on-demand generation of streams of correlated photons such as cluster states and could be used as a resource for robust transmission and processing of quantum information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon statistics in the macroscopic realm measured without photon counters

In a macroscopic realm, in which photons are too many to be counted by any photon-counting detector, photon statistics can be measured by using detectors simply endowed with linear response. We insert one of such detectors in a conventional photon-counting apparatus, which returns a voltage every time the detector responds to light by generating a number of elementary charges via its primary photodetection process. We only assume that, when a single charge is photogenerated, the probability density of the voltages is a distribution that is narrow with respect to its mean value. Under this hypothesis the output voltages can be suitably binned so that their probability distribution is the same as that of the photogenerated charges, that is, of the detected photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗