Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

New Insertion Device Control System for the APS Upgrade

New Hybrid Permanent Magnet Undulators (HPMUs) have been designed and manufactured using servo motors for precise and reliable gap motion control for the Advanced Photon Source Upgrade (APS-U) project. Meanwhile, existing HPMUs equipped with legacy stepper motors are systematically replaced with servo motors. In parallel with mechanical modifications of the undulators, a comprehensive upgrade has been implemented for the control of the devices. This upgrade includes integration of standardized industrial components for replacement of motor controllers and motor drives using the Kollmorgen Programmable Controller Multi-axis Master (PCMM) controllers and the AKD2G series servo drives. Soft Input Output Controllers (IOCs) are developed and deployed to replace the legacy VME-based IOCs for both single-period undulators and Revolver undulators. In this paper, we will present the architecture of the new insertion device control system, including control mechanisms, interlock protocols, and tools for diagnostics and troubleshooting.

Li, W.↗

A balloon-borne Ge/Li/ spectrometer for gamma-ray astronomy

On June 10, 1974, a new high-resolution gamma ray spectrometer operating in the energy range of 0.05 to 10 MeV was successfully balloon-flight tested. This system uses four 40 cu cm Ge(Li) crystals in a single cryostat as prime sensors. A 6.35 cm thick CsI (Na) shield provides background rejection and collimation, defining a solid angle of 0.095 sr. Cooling is provided by a liquid-nitrogen dewar. The system was highly stable with spectral resolution of better than 2.5 keV at 1 MeV for the flight duration. The background total count rate was about 20 counts/sec. Numerous lines were observed, most of which originated from secondary neutron interactions in the spectrometer. The sensitivity of the system to line emissions originating in cosmic point sources is 0.0001 to 0.001 photons per sq cm s over the energy range.

Jacobson, A. S.↗

Gravitational analog of the canonical acoustic black hole in Einstein-scalar-Gauss-Bonnet theory

In this work, in the context of modified gravity, a curved spacetime analogous to the 'canonical acoustic black hole (CABH)' is constructed. The source is a self-interacting scalar field which is non-minimally coupled to gravity through the Gauss–Bonnet invariant. The scalar-Gauss–Bonnet coupling function is characterized by three positive parameters: σ with units of (length), μ with units of (length)4, and a dimensionless parameter s, thus defining a three-parameter model for which the line element of CABH is a solution. The spacetime is equipped with spherical and static symmetry and has a single horizon determined in Schwarzschild coordinates by the region r = μ^(1/4). The solution admits a photon sphere at r = (3μ)^(1/4), and it is shown that in the region (3μ)^(1/4) ⩽ r < ∞ the scalar field satisfies the null, weak, and strong energy conditions. Nonetheless, the model with s = 1 has major physical relevance since for this case the scalar field is well defined in the entire region r ⩾ μ^(1/4), while for s ≠ 1 the scalar field blows up on the horizon.

Pedro Cañate↗

Density scaling approximation for Monte-Carlo simulations of radioactive plumes

The release of radioactive gas into the atmosphere can diffuse into large volumes of air downwind from the point of release. The extent of radioactivity can cover thousands of cubic meters of air. For such large volumes, the weather models used to predict the down-wind distribution of the plume and the radiation transport models used to predict the radiation reaching ground-level from the plume can take tens of hours of computer time on multi-node institutional High-Performance Computing facilities. In this paper we focus on the radiation transport aspect of plume modeling. Here, we describe a phenomenological method for approximating the amounts of radiation that reach ground level from large volumes of a static radioactive plume that can be calculated on a stand-alone personal computer in much shorter computation times than those usually needed for such large volume evaluations. We refer to this method as the Density Scaling Approximation (DSA). Its ability to approximate ground-level count rates of large plumes comes from using a small-plume volume with a scaled-up value of air density to simulate the same number of scatterings that occur during transport in larger plume volumes at normal air density. We demonstrate the DSA by using a 100 m-diameter air-filled hemispherical dome geometry with a uniform volumetric activity of 135 Xe gas throughout the air-filled volume. The DSA for a larger dome diameter is obtained by evaluating the 100 m dome with an air density scaled up by the linear ratio of the larger diameter to the 100 m diameter. We find that this approximation works well for dome diameters up to 1200 m – the largest diameter studied and a size more than sufficient for accounting for all the radiation from 135 Xe. Moreover, most of our DSA results can be calculated over 500 times faster than corresponding full-sized geometry with normal air density. To help evaluate the accuracy of the DSA and gain insight into how well it can reproduce different regions of the spectra, we use three, easily understood regions of interest to compare the DSA results to the full-sized geometry at normal air density results. These regions are the full-energy peak, the region of single-Compton scattering, and the region of multiple-Compton scattering. We show how the dominance of the Compton scattering mechanism determines this division and thus provides insight into how Compton scattering is manifested in spectra from photon scattering through air in general, and how well the DSA approximation works.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IRAS surface brightness maps of visible reflection nebulae: Evidence for non-equilibrium infrared emission

Surface brightness maps at 12, 25, 60, and 100 microns of 16 visible reflection nebulae were extracted from the Infrared Astronomy Satellite (IRAS) database. The maps were produced by coadding IRAS survey scans over areas centered on the illuminating stars, and have spatial resolutions of 0.9' x 4' at 12 and 25 microns, 1.8' x 4.5' at 60 microns, and 3.6' x 5' at 100 microns. Extended emission in the four IRAS bandpasses was detected in fourteen of the reflection nebulae. The IRAS data were used to measure the flux of the infrared emission associated with each source. The energy distributions show that the 12 micron flux is greater than the 25 micron flux in 11 of the nebulae, and the peak flux occurs in the 60 or 100 micron bandpass in all 16 nebular. The 60 and 100 micron flux can be approximated by blackbodies with temperatures between 30 and 50 K, consistent with temperatures expected from extrapolation of greybody fits to the 60 and 100 micron data. The excess 12 and 25 micron emission is attributed to a nonequilibrium process such as emission from thermal fluctuations of very small grains excited by single ultraviolet photons, or emission from polycyclic aromatic hydrocarbons (PAHs) excited by ultraviolet radiation. The common features of the energy distributions of the 16 reflection nebulae, also seen in the reflection nebulae associated with the Pleiades, suggest that PAHs or very small grains may be found in most reflection nebulae.

Castelaz, M. W.↗

High-energy X-ray radiography with apodized petawatt laser beams

We have produced laser wakefield-accelerated electron beams with energies of 2 GeV in Target Area 1 of the ZEUS facility. These electron beams oscillate in the accelerating structure that is produced in the wake of an ultrashort laser pulse (25 fs). These ’betatron’ oscillations result in the emission of a collimated (4 mrad divergence) beam of high-energy X-ray/gamma photons (on the order of several hundred keV). In this work, we demonstrate the capabilities of the ZEUS laser system by showing that apodizing the laser beam in the near field allows for the production of high-quality betatron X-rays for radiography purposes. This demonstrates that a high-power, large-aperture laser beam could be split into multiple parts to drive betatron X-ray sources from multiple angles or temporal delays into a High Energy Density (HED) target to be probed, enabling pump-probe measurements at multiple temporal delays or tomography on a single shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diffraction data from aerosolized Coliphage PR772 virus particles imaged with the Linac Coherent Light Source

Single Particle Imaging (SPI) with intense coherent X-ray pulses from X-ray free-electron lasers (XFELs) has the potential to produce molecular structures without the need for crystallization or freezing. Here we present a dataset of 285,944 diffraction patterns from aerosolized Coliphage PR772 virus particles injected into the femtosecond X-ray pulses of the Linac Coherent Light Source (LCLS). Additional exposures with background information are also deposited. The diffraction data were collected at the Atomic, Molecular and Optical Science Instrument (AMO) of the LCLS in 4 experimental beam times during a period of four years. The photon energy was either 1.2 or 1.7 keV and the pulse energy was between 2 and 4 mJ in a focal spot of about 1.3 μm x 1.7 μm full width at half maximum (FWHM). The X-ray laser pulses captured the particles in random orientations. The data offer insight into aerosolised virus particles in the gas phase, contain information relevant to improving experimental parameters, and provide a basis for developing algorithms for image analysis and reconstruction.

59 BASIC BIOLOGICAL SCIENCES↗

Low-loss superconducting titanium nitride grown using plasma-assisted molecular beam epitaxy

Titanium nitride (TiN) is a known superconducting material that is attractive for use as passive components in superconducting circuits for both conventional and quantum information devices. In contrast to conventional synthesis techniques, here, plasma-assisted molecular beam epitaxy is reported to produce high-quality TiN on bare silicon wafers. Using a rf-plasma source to crack the nitrogen molecules and a conventional high-temperature effusion cell for titanium, TiN growth is completed under nitrogen-rich conditions. The growth and nucleation is monitored in situ, while the structure and composition are characterized using x-ray diffraction, atomic force microscopy, x-ray photoelectron spectroscopy, secondary ion mass spectroscopy, and scanning transmission electron microscopy. The stoichiometric TiN (111) films sit on an amorphous nitride layer with low impurity concentrations. The films superconduct with Tc=5.4 K, and coplanar waveguide resonators are fabricated with a small center width of 6 μm that demonstrate single-photon quality factors approaching 1M and high-power quality factors over 5M without observing saturation.

Richardson, C. J. K. (ORCID:0000000188175347)↗

Impact Testing of Heat Source Exemplars

This report details the heat source impact testing performed at the Shock Thermodynamics Applied Research Facility (STAR). The purpose of these tests were to measure the impact behavior of a heated Ta-10W tantalum/tungsten alloy heat source exemplar. Each exemplar resembled a cylinder with a rectangular through-hole orthogonal to the cylinder axis-of-symmetry. In each test, the exemplar was impacted by a hardened steel impactor accelerated using the STAR air gun. The exemplars were impacted perpendicular to the through-hole and at an an angle to the cylindrical axis-of-symmetry. The exemplar bar stock source, impact angle, and impact velocity were varied throughout the testing series. High-speed video was used to measure dynamic impact behavior while photon doppler velocimetry (PDV) and shorting pins were used to measure the impact velocity. Foam support structures were used to thermally isolate the exemplar and provide a support structure which was non-perturbative to the impact event. Soft-catch techniques were used to minimize secondary impacts and enable recovery for detailed post-shot analysis. Results indicate positive correlation between exemplar fracture and the variables of impact velocity and impact angle. Exemplar fracture occurred consistently along a single corner of the through-hole.

36 MATERIALS SCIENCE↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

Ultra-high dose rate FLASH irradiator at the radiological research accelerator facility

The Radiological Research Accelerator Facility has modified a decommissioned Varian Clinac to deliver ultra-high dose rates: operating in 9 MeV electron mode ( FLASH mode), samples can be irradiated at a Source-Surface Distance (SSD) of 20 cm at average dose rates of up to 600 Gy/s (3.3 Gy per 0.13 µs pulse, 180 pulses per second). In this mode multiple pulses are required for most irradiations. By modulating pulse repetition rate and irradiating at SSD = 171 cm, dose rates below 1 Gy/min can be achieved, allowing comparison of FLASH and conventional irradiations with the same beam. Operating in 6 MV photon mode, with the conversion target removed ( SuperFLASH mode), samples are irradiated at higher dose rates (0.2–150 Gy per 5 µs pulse, 360 pulses per second) and most irradiations can be performed with a single very high dose rate pulse. In both modes we have seen the expected inverse relation between dose rate and irradiated area, with the highest dose rates obtained for beams with a FWHM of about 2 cm and ± 10% uniformity over 1 cm diameter. As an example of operation of the ultra-high dose rate FLASH irradiator, we present dose rate dependence of dicentric chromosome yields.

43 PARTICLE ACCELERATORS↗

Unraveling sources of emission heterogeneity in Silicon Vacancy color centers with cryo-cathodoluminescence microscopy

Diamond color centers have proven to be versatile quantum emitters and exquisite sensors of stress, temperature, electric and magnetic fields, and biochemical processes. Among color centers, the silicon-vacancy (SiV - ) defect exhibits high brightness, minimal phonon coupling, narrow optical linewidths, and high degrees of photon indistinguishability. Yet the creation of reliable and scalable SiV - -based color centers has been hampered by heterogeneous emission, theorized to originate from surface imperfections, crystal lattice strain, defect symmetry, or other lattice impurities. Here, we advance high-resolution cryo-electron microscopy combined with cathodolumines cence spectroscopy and 4D scanning transmission electron microscopy (STEM) to elucidate the structural sources of heterogeneity in SiV - emission from nanodiamond with sub-nanometer-scale resolution. Our diamond nanoparticles are grown directly on TEM membranes from molecular-level seedings, representing the natural formation conditions of color centers in diamond. We show that individual subcrystallites within a single nanodiamond exhibit distinct zero-phonon line (ZPL) energies and differences in brightness that can vary by 0.1 meV in energy and over 70% in brightness. These changes are correlated with the atomic-scale lattice structure. We find that ZPL blue shifts result from tensile strain, while ZPL red shifts are due to compressive strain. We also find that distinct crystallites host distinct densities of SiV - emitters and that grain boundaries impact SiV - emission significantly. Finally, we interrogate nanodiamonds as small as 40 nm in diameter and show that these diamonds exhibit no spatial change to their ZPL energy. Our work provides a foundation for atomic-scale structure-emission correlation, e.g., of single atomic defects in a range of quantum and two-dimensional materials.

36 MATERIALS SCIENCE↗

Photon energy-resolved velocity map imaging from spectral domain ghost imaging

Abstract We present an approach that combines photon spectrum correlation analysis with the reconstruction of three-dimensional momentum distribution from velocity map images in an efficient, single-step procedure. We demonstrate its efficacy with the results from the photoionization of the 2 p -shell of argon using the Free-electron LASer in Hamburg free-electron laser (FEL). Distinct spectral features due to the spin-orbit splitting of Ar + ( 2 p − 1 ) are resolved, despite the large average bandwidth of the ionizing pulses from the FEL. This demonstrates a clear advantage over the conventional analysis method, and it will be broadly beneficial for velocity map imaging experiments with FEL sources. The retrieved linewidth of the binding energy spectrum approaches the resolution limitation prescribed by the spectrometers used to collect the data. Our approach presents a path to extend spectral-domain ghost imaging to the case where the photoproduct observable is high-dimensional.

47 OTHER INSTRUMENTATION↗

Prediction Accuracy of Error Rates for MPTB Space Experiment

This paper addresses the accuracy of radiation-induced upset-rate predictions in space using the results of ground-based measurements together with standard environmental and device models. The study is focused on two part types - 16 Mb NEC DRAM's (UPD4216) and 1 Kb SRAM's (AMD93L422) - both of which are currently in space on board the Microelectronics and Photonics Test Bed (MPTB). To date, ground-based measurements of proton-induced single event upset (SEM cross sections as a function of energy have been obtained and combined with models of the proton environment to predict proton-induced error rates in space. The role played by uncertainties in the environmental models will be determined by comparing the modeled radiation environment with the actual environment measured aboard MPTB. Heavy-ion induced upsets have also been obtained from MPTB and will be compared with the "predicted" error rate following ground testing that will be done in the near future. These results should help identify sources of uncertainty in predictions of SEU rates in space.

Buchner, S. P.↗

Perovskite CsPbBr 3 Single-Crystal Detector Operating at 10 10 Photons s -1 mm -2 for Ultra-High Flux X-ray Detection

Semiconductors for detecting hard radiation are confronted with considerable problems when operating at high photon fluxes. A perovskite CsPbBr 3 single-crystal detector capable of operating at X-ray fluxes of up to 10 10 photons s -1 mm -2 with beam area ≤ 0.25 mm 2 at 58.61 keV for current-mode X-ray detection is reported. The spectrometer-grade melt-grown CsPbBr 3 detectors show a gamma-ray energy resolution of ~7.5% at 122 keV for 57 Co and dark current as low as 4.3 nA (0.5 nA mm -2 ) at a reverse bias voltage of 200 V (118 V mm -1 ). The detector is tested at X-ray energies of 8.2, 10, and 58.61 keV at a synchrotron light source under a reverse bias voltage of up to 1000 V (588 V mm -1 ). Under a sufficiently high bias voltage and within several hundreds of seconds X-ray exposure, good photocurrent linearity (goodness of fit R 2 > 0.99) and reproducibility are obtained up to a flux of ≈10 10 photons s -1 mm -2 at beam area 0.25 mm 2 with Lower Limit of Detection of ≈10 5 photons s -1 mm -2 and Charge Collection Efficiency of ≈100% for 58.61 keV X-rays. Therefore, wide application of CsPbBr 3 detectors in high-flux X-ray detection is anticipated.

36 MATERIALS SCIENCE↗

Tunable x-ray free electron laser multi-pulses with nanosecond separation

X-ray Free Electron Lasers provide femtosecond x-ray pulses with narrow bandwidth and unprecedented peak brightness. Special modes of operation have been developed to deliver double pulses for x-ray pump, x-ray probe experiments. However, the longest delay between the two pulses achieved with existing single bucket methods is less than 1 picosecond, thus preventing the exploration of longer time-scale dynamics. We present a novel two-bucket scheme covering delays from 350 picoseconds to hundreds of nanoseconds in discrete steps of 350 picoseconds. Performance for each pulse can be similar to the one in a single pulse operation. The method has been experimentally tested with the Linac Coherent Light Source (LCLS-I) and the copper linac with LCLS-II hard x-ray undulators.

47 OTHER INSTRUMENTATION↗

A New Superconducting Undulator Cryostat for the APS Upgrade

The Advanced Photon Source (APS) is in the midst of a major facility upgrade including both a new electron storage ring (SR) and many new insertion devices ( IDs) providing x-ray photon beams to a new suite of experimental end stations. Included among the new IDs are four 4.8-meter superconducting undulator (SCU) cryostats, each containing two 1.8-meter planar undulator magnets operating at 4.2 K in either a phase shifted or canted configuration. We describe a new, compact cryocooler-based cryostat design which supports the magnets and associated subsystems and also fits the space constraints of the SR ID straight sections. The design is an evolution of earlier single-magnet 2-meter cryostats, retaining some subsystem commonality while incorporating lessons learned and several features unique to the challenge of supporting two independently operable undulator magnets in a single device.

Anliker, E.↗

The scattered solar X-ray background in low earth orbit

In order to interpret X-ray observations of the sun-lit earth obtained with the IPC, a detailed model is developed that treats the radiative transfer of solar X-rays in single scattering approximation and employs the relevant scattering processes (elastic Thomson scattering and inelastic fluorescent scattering). The X-ray-bright earth, one of the strongest soft X-ray sources seen by the IPC, can then be understood in terms of solar X-rays scattered in the upper atmosphere. Using the CIRA 1972 Reference Atmosphere, it is possible to account for the observed 'bright earth' X-ray light curves under a variety of different viewing geometries. It is argued that the observed changes in hardness ratio of the scattered radiation can be interpreted as an indication of a change in the ratio of Thomson and fluorescently scattered photons as a function of zenith angle. The relevance of bright earth X-ray observations is further discussed in the context of operating X-ray telescopes in low-earth orbit, as well as in a broader astrophysical context.

Fink, H. H.↗