Search NASA⌕ Search

SEARCH · Search NASA

Results for “small lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Ablation loading of barium ions into a surface-electrode trap

Trapped-ion quantum information processing may benefit from qubits encoded in isotopes that are practically available in only small quantities, e.g., due to low natural abundance or radioactivity. Laser ablation provides a method of controllably liberating neutral atoms or ions from low-volume targets, but energetic ablation products can be difficult to confine in the small ion-electrode distance, micron-scale microfabricated traps amenable to high-speed, high-fidelity manipulation of ion arrays. Here, we investigate ablation-based ion loading into surface-electrode traps of different sizes to test a model describing ion loading probability as a function of effective trap volume and other trap parameters. We characterize loading of ablated barium from a metallic source in two cryogenic surface-electrode traps with 730 and 50 μm ion-electrode distances. Furthermore, our loading rate agrees with a predictive analytical model, providing insight for the confinement of limited-quantity species of interest for quantum computing, simulation, and sensing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Laser-driven x-ray and proton micro-source and application to simultaneous single-shot bi-modal radiographic imaging

Radiographic imaging with x-rays and protons is an omnipresent tool in basic research and applications in industry, material science and medical diagnostics. The information contained in both modalities can often be valuable in principle, but difficult to access simultaneously. Laser-driven solid-density plasma-sources deliver both kinds of radiation, but mostly single modalities have been explored for applications. Their potential for bi-modal radiographic imaging has never been fully realized, due to problems in generating appropriate sources and separating image modalities. Here, we report on the generation of proton and x-ray micro-sources in laser-plasma interactions of the focused Texas Petawatt laser with solid-density, micrometer-sized tungsten needles. We apply them for bi-modal radiographic imaging of biological and technological objects in a single laser shot. Thereby, advantages of laser-driven sources could be enriched beyond their small footprint by embracing their additional unique properties, including the spectral bandwidth, small source size and multi-mode emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mapping the Topography of Mercury with MESSENGER Laser Altimetry

The Mercury Laser Altimeter onboard MESSENGER involves unique design elements that deal with the challenges of being in orbit around Mercury. The Mercury Laser Altimeter (MLA) is one of seven instruments on NASA's MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) spacecraft. MESSENGER was launched on 3 August 2004, and entered into orbit about Mercury on 18 March 2011 after a journey through the inner solar system. This involved six planetary flybys, including three of Mercury. MLA is designed to map the topography and landforms of Mercury's surface. It also measures the planet's forced libration (motion about the spin axis), which helps constrain the state of the core. The first science measurements from orbit taken with MLA were made on 29 March 2011 and continue to date. MLA had accumulated about 8.3 million laser ranging measurements to Mercury's surface, as of 31 July 2012, i.e., over six Mercury years (528 Earth days). Although MLA is the third planetary lidar built at the NASA Goddard Space Flight Center (GSFC), MLA must endure a much harsher thermal environment near Mercury than the previous instruments on Mars and Earth satellites. The design of MLA was derived in part from that of the Mars Orbiter Laser Altimeter on Mars Global Surveyor. However, MLA must range over greater distances and often in off-nadir directions from a highly eccentric orbit. In MLA we use a single-mode diode-pumped Nd:YAG (neodymium-doped yttrium aluminum garnet) laser that is highly collimated to maintain a small footprint on the planet. The receiver has both a narrow field of view and a narrow spectral bandwidth to minimize the amount of background light detected from the sunlit hemisphere of Mercury. We achieve the highest possible receiver sensitivity by employing the minimum receiver detection threshold.

planetary lidar↗

NASA Tech Briefs, July 2004

Topics: Optoelectronic Sensor System for Guidance in Docking; Hybrid Piezoelectric/Fiber-Optic Sensor Sheets; Multisensor Arrays for Greater Reliability and Accuracy; Integrated-Optic Oxygen Sensors; Ka-Band Autonomous Formation Flying Sensor; CMOS VLSI Active-Pixel Sensor for Tracking; Lightweight, Self-Deploying Foam Antenna Structures; Electrically Small Microstrip Quarter-Wave Monopole Antennas; A 2-to-28-MHz Phase-Locked Loop; Portable Electromyograph; Open-Source Software for Modeling of Nanoelectronic Devices; Software for Generating Strip Maps from SAR Data; Calibration Software for use with Jurassicprok; Software for Probabilistic Risk Reduction; Software Processes SAR Motion-Measurement Data; Improved Method of Purifying Carbon Nanotubes; Patterned Growth of Carbon Nanotubes or Nanofibers; Lightweight, Rack-Mountable Composite Cold Plate/Shelves; SiC-Based Miniature High-Temperature Cantilever Anemometer; Inlet Housing for a Partial-Admission Turbine; Lightweight Thermoformed Structural Components and Optics; Growing High-Quality InAs Quantum Dots for Infrared Lasers; Selected Papers on Protoplanetary Disks; Module for Oxygenating Water without Generating Bubbles; Coastal Research Imaging Spectrometer; Rapid Switching and Modulation by use of Coupled VCSELs; Laser-Induced-Fluorescence Photogrammetry and Videogrammetry; Laboratory Apparatus Generates Dual-Species Cold Atomic Beam; Laser Ablation of Materials for Propulsion of Spacecraft; Small Active Radiation Monitor; Hybrid Image-Plane/Stereo Manipulation; Partitioning a Gridded Rectangle into Smaller Rectangles; Digital Radar-Signal Processors Implemented in FPGAs; Part 1 of a Computational Study of a Drop-Laden Mixing Layer; and Some Improvements in Signal-Conditioning Circuits.

Source record↗

Application of High-Spatial Resolution LA-MC-ICP-MS in Planetary Materials

High-precision stable and radiogenic isotopic measurements of planetary materials can help elucidate processes taking place during early Solar System formation, as well as during subsequent planetary differentiation. Laser Ablation Multi Collector Inductively Coupled Plasma Mass Spectrometry (LA-MC-ICP-MS) adds the valuable ability of preserving the spatial context of these isotopic measurements, by sampling small sample volumes (~10 – 60 um diameter) using a pulsed laser system. In the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center, these in-situ isotopic measurements are primarily made using the Applied SpectraTM iX-fs-Tandem LA-LIBS Instrument coupled to the Nu InstrumentsTM SP1700 MC-ICP-MS. The instrumental set-up also provides simultaneous Laser Induced Breakdown Spectroscopy (LIBS) measurements and the potential use of a low energy path with a collision/reaction cell for additional interference removal, though we focus here on the typical high-energy LA-MC-ICP-MS operation. We will provide examples of stable (e.g., Mg) and radiogenic (e.g., Lu-Hf) isotopic systems measured in planetary materials and their terrestrial analogs. The measurement of mass dependent Mg isotopic variations is an important tool for reconstructing processes such as evaporation and condensation of solids in the solar nebula. For early Solar System samples, Mg isotope measurements are also important for the short-lived (t1/2 = 0.7 Ma) Al-Mg chronometer. During laser ablation analyses, the measurement of the Al-Mg isotopic system is made in medium mass resolution (RP ~9500 at ~20% transmission) to limit interferences from 48Ti2+ and 48Ca2+ on 24Mg+, in addition to 52Cr2+ and 12C14N+ on 26Mg+. Measured in the mineral zircon, the 176Lu-176Hf decay system is often used for understanding the growth of continents on Earth, and is also a vital aid in deciphering early large-scale planetary differentiation processes, such as the crystallization of the lunar magma ocean, which is thought to be responsible for much of the Moon’s crust. Lu-Hf measurements are made in low resolution mode (RP <2000), with 10 ion masses (from 171Yb to 180Hf) measured simultaneously to facilitate corrections for isobaric interferences from 176Yb and 176Lu on 176Hf.

Jacob B Setera↗

Processing of the laser Doppler velocimeter signals

The laser Doppler velocimeter (LDV) is a probeless technique that provides a remote measurement of mean and fluctuating velocities. The measurement is actually obtained from small particles embedded in the flow which scatter light from an illuminating laser beam interference pattern. A portion of this scattered light is collected by a photomultiplier which yields an electronic signal whose frequency is directly proportional to the velocity of the small particles. The purpose of this paper is to describe and critically compare three techniques most used to process this electronic signal. These techniques are: (1) spectrum analyzer - a frequency scanning filter (frequency domain instrument), (2) wide-band frequency tracker - a frequency lock loop (frequency domain instrument), and (3) high-speed frequency counter - an interval timer (time domain instrument). The study determines the ability of each technique to process the LDV signal and yield velocity data to be used in determining the flow characteristics.

Meyers, J. F.↗

Laser extensometer

Drift-compensated and intensity-averaged laser-based system uses optical and photoelectric effects for precise measurement of small thermally-induced size changes. Final output signal is directly proportional to size of sample shadow and independent of laser intensity, detector dark current, and lateral motion of sample.

Stocker, P. L.↗

Particle and flow field measurements by laser holography

Holograms make transmission recordings of aerodynamic events which are real-illuminated with ground-glass light diffusers and with no requirements for precision. The three-dimensional interferograms can be recorded by stored-beam, double-exposure, and double-plate techniques. Weak traveling shock waves, generated by rotating blade rows of an aircraft fan compressor, can be visualized by rapid double-exposure holograms recorded with a ruby laser. The same laser technique can also determine flow velocities from holograms of small flow-entrained particles. Particles larger than one-quarter millimeter are recorded under rear diffuse illumination conditions. Smaller particles can be recorded by their own forward scattering of laser light through the sensitivity of the holographic process for weak signals. Since the holographic apparatus can be path-matched, both particle and flow interferograms can be recorded with lasers of short coherence length.

Wuerker, R. F.↗

Pseudo-Random Modulation of a Laser Diode for Generating Ultrasonic Longitudinal Waves

Laser generated ultrasound systems have historically been more complicated and expensive than conventional piezoelectric based systems, and this fact has relegated the acceptance of laser based systems to niche applications for which piezoelectric based systems are less suitable. Lowering system costs, while improving throughput, increasing ultrasound signal levels, and improving signal-to-noise are goals which will help increase the general acceptance of laser based ultrasound. One current limitation with conventional laser generated ultrasound is a material s damage threshold limit. Increasing the optical power to generate more signal eventually damages the material being tested due to rapid, high heating. Generation limitations for laser based ultrasound suggests the use of pulse modulation techniques as an alternate generation method. Pulse modulation techniques can spread the laser energy over time or space, thus reducing laser power densities and minimizing damage. Previous experiments by various organizations using spatial or temporal pulse modulation have been shown to generate detectable surface, plate, and bulk ultrasonic waves with narrow frequency bandwidths . Using narrow frequency bandwidths improved signal detectability, but required the use of expensive and powerful lasers and opto-electronic systems. The use of a laser diode to generate ultrasound is attractive because of its low cost, small size, light weight, simple optics and modulation capability. The use of pulse compression techniques should allow certain types of laser diodes to produce usable ultrasonic signals. The method also does not need to be limited to narrow frequency bandwidths. The method demonstrated here uses a low power laser diode (approximately 150 mW) that is modulated by controlling the diode s drive current and the resulting signal is recovered by cross correlation. A potential application for this system which is briefly demonstrated is in detecting signals in thick composite materials where attenuation is high and signal amplitude and bandwidth are at a premium.

Madaras, Eric I.↗

Low Power Consumption Lasers for Miniature Optical Spectrometers for Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 micron wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micron and quantum cascade (QC) lasers in the 4.0-5.0 micron range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

Distributed Feedback (DFB) Diode Lasers↗

Low Power Consumption Laser for Next Generation Miniature Optical Spectrometers for Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 mu m wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 mu m and quantum cascade (QC) lasers in the 4.0-5.0 mu m range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft

distributed feedback laser (DFB↗

Whispering Gallery Mode Resonators as Optical Reference Cavities

Highly stabilized lasers are an increasingly valuable tool for metrology. For many applications, however, existing Fabry Perot systems are too bulky and cumbersome. We are investigating the use of miniature monolithic whispering gallery mode resonators as reference cavities for laser stabilization. We seek to exploit the benefit of small size and vibration resistance by suppressing thermally induced frequency fluctuations. We have theoretically investigated the viability of using a thin-film coating to achieve temperature compensation. We have experimentally investigated an active temperature stabilization scheme based on birefringence in a crystalline resonator. We also report progress of laser locking to the resonators.

optical frequency↗

Signature of Collective Plasma Effects in Beam-Driven QED Cascades

QED cascades play an important role in extreme astrophysical environments like magnetars. Furthermore, they can also be produced by passing a relativistic electron beam through an intense laser field. Signatures of collective pair plasma effects in these QED cascades are shown to appear, in exquisite detail, through plasma-induced frequency upshifts in the laser spectrum. Remarkably, these signatures can be detected even in small plasma volumes moving at relativistic speeds. Strong-field quantum and collective pair plasma effects can thus be explored with existing technology, provided that ultradense electron beams are colocated with multipetawatt lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ground-to-orbit laser propulsion: Advanced applications

Laser propulsion uses a large fixed laser to supply energy to heat an inert propellant in a rocket thruster. Such a system has two potential advantages: extreme simplicity of the thruster, and potentially high performance, particularly high exhaust velocity. By taking advantage of the simplicity of the thruster, it should be possible to launch small (10 to 1000 kg) payloads to orbit using roughly 1 MW of average laser power per kg of payload. The incremental cost of such launches would be of an order of $200/kg for the smallest systems, decreasing to essentially the cost of electricity to run the laser (a few times $10/kg) for larger systems. Although the individual payload size would be smaller, a laser launch system would be inherently high-volume, with the capacity to launch tens of thousands of payloads per year. Also, with high exhaust velocity, a laser launch system could launch payloads to high velocities - geosynchronous transfer, Earth escape, or beyond - at a relatively small premium over launches to LEO. The status of pulsed laser propulsion is briefly reviewed including proposals for advanced vehicles. Several applications appropriate to the early part of the next century and perhaps valuable well into the next millennium are discussed qualitatively: space habitat supply, deep space mission supply, nuclear waste disposal, and manned vehicle launching.

Kare, Jordin T.↗

Low Power Consumption Lasers for Next Generation Miniature Optical Spectrometers for Major Constituent and Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. The minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental frequency of the target gases which are mostly in the 3.0-5.0 micrometers wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micrometers and quantum cascade (QC) lasers in the 4.0-5.0 micrometers range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

semiconductor lasers↗

First study of Hohlraum x-ray preheat asymmetry inside an ICF capsule

In indirect drive inertial confinement fusion (ICF), laser induced Hohlraum preheat radiation (so-called M-band, >1.8 keV) asymmetry will lead to asymmetric ablation front and ablator–fuel interface hydrodynamic instability growth in an imploding capsule. First experiments to infer the M-band asymmetries at the capsule were performed on the National Ignition Facility for high density carbon (HDC) ICF capsules in low density fill (0.3 mg/cc 4 He) Au Hohlraums by time resolved imaging of 2.3 keV fluorescence emission of a smaller Mo sphere placed inside the capsule. In this study, the measured Mo emission is pole hot (P 2 > 0) since M-band is generated mainly by the outer laser beams as their irradiance at the Hohlraum wall is 5× higher than for the inner beams. P 2 has a greater negative than positive swing vs time [Δ(P 2 /P 0 )/Δt ~ 0.2/ns], giving insight into laser heated Hohlraum dynamics. P 4 asymmetry is small at the sphere due to efficient geometric smoothing of Hohlraum asymmetries at large Hohlraum -to-capsule ratios. The M-band P 2 history is qualitatively reproduced by radiation hydrodynamic HYDRA simulations. The smaller P 2 than that calculated earlier suggests either less outer beam spot motion and/or preheat emission. At late times, the observed P 2 swing is larger and P 4 is more negative than simulated, which could be due to inner beams being stopped more in the outer beams wall plasma bubble than simulated. Asymmetry at the HDC capsule inner surface (“ice–ablator interface”) is also inferred from the Mo emission asymmetry by an analytic viewfactor model, accounting for the Mo/HDC radius difference and HDC capsule opacity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation of functionally graded steel by laser powder bed fusion via in-situ carbon doping

Additive Manufacturing (AM) enables functional integration by combining multiple components into a single part to shorten assembly time, reduce weight, and improve performance. Laser Powder Bed Fusion (LPBF) is an important AM method due to excellent spatial resolution, surface finish, and material properties without the need for extensive post-processing. Functional integration could be enhanced by spatial tuning of properties, but LPBF cannot readily vary material composition. Here, this paper addresses a method to add spatial composition control by printing small quantities of dopants via liquid carrier prior to laser fusion. The impact of carbon black suspension added to select regions of a Stainless Steel 316 L powder bed on melt pool dimension, hardness, and porosity is reported. The distribution of the carbon between the doped and plain layers and the resulting spatial variation in hardness is measured. Optical microscopy and composition analysis show that the carbon dispersed uniformly within the layer of deposition and diffused as little as 50 μm in the build direction. Keyhole conditions dramatically increase the inter-layer transport of the dopant. The added carbon increased hardness by >50 %. Porosity increased in doped regions but remained below 1.5 % for the best processing parameters. These results demonstrate that the composition of LPBF parts could be controlled in 3-dimensions using a dopant that is soluble in the melt pool. Additional work will be required to evaluate different dopant materials and optimize processing conditions for full density, but microalloying with soluble dopants appears to be a plausible solution to enhance functional integration with LPBF.

36 MATERIALS SCIENCE↗