Search NASA⌕ Search

SEARCH · Search NASA

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Laser ion source with a double pulse laser system

To extend an ion beam pulse of a laser ion source, multiple laser shots could be used. To check the feasibility of this idea, we tested double laser irradiations on an iron target. When the interval of the two laser shots is longer than 10 {mu}s, the obtained ion current profile was expressed as a sum of two individual expanded laser plasmas. However, if the interval is too close, a current reduction was observed. This technique can be effectively applied to low charge state ion production.

43 PARTICLE ACCELERATORS↗

R and D toward a compact high-brilliance X-ray source based on channeling radiation

X-rays have been valuable to a large number of fields including Science, Medicine, and Security. Yet, the availability of a compact high-spectral brilliance X-ray sources is limited. A technique to produce X-rays with spectral brilliance B{approx} 10{sup 12} photons.(mm-mrd){sup -2}. (0.1% BW){sup -1}.s{sup -1} is discussed. The method is based on the generation and acceleration of a low-emittance field-emitted electron bunches. The bunches are then focused on a diamond crystal thereby producing channeling radiation. In this paper, after presenting the overarching concept, we discuss the generation, acceleration and transport of the low-emittance bunches with parameters consistent with the production of high-brilliance X-rays through channeling radiation. We especially consider the example of the Advanced Superconducting Test Accelerator (ASTA) currently in construction at Fermilab where a proof-of-principle experiment is in preparation.

43 PARTICLE ACCELERATORS↗

A comparison of four direct geometry time-of-flight spectrometers at the Spallation Neutron Source

The Spallation Neutron Source at Oak Ridge National Laboratory now hosts four direct geometry time-of-flight chopper spectrometers. These instruments cover a range of wave-vector and energy transfer space with varying degrees of neutron flux and resolution. The regions of reciprocal and energy space available to measure at these instruments are not exclusive and overlap significantly. We present a direct comparison of the capabilities of this instrumentation, conducted by data mining the instrument usage histories, and specific scanning regimes. In addition, one of the common science missions for these instruments is the study of magnetic excitations in condensed matter systems. We have measured the powder averaged spin wave spectra in one particular sample using each of these instruments, and use these data in our comparisons.

07 ISOTOPE AND RADIATION SOURCES↗

Investigation on the electron flux to the wall in the VENUS ion source

The long-term operation of high charge state electron cyclotron resonance ion sources fed with high microwave power has caused damage to the plasma chamber wall in several laboratories. Porosity, or a small hole, can be progressively created in the chamber wall which can destroy the plasma chamber over a few year time scale. A burnout of the VENUS plasma chamber is investigated in which the hole formation in relation to the local hot electron power density is studied. First, the results of a simple model assuming that hot electrons are fully magnetized and strictly following magnetic field lines are presented. The model qualitatively reproduces the experimental traces left by the plasma on the wall. However, it is too crude to reproduce the localized electron power density for creating a hole in the chamber wall. Second, the results of a Monte Carlo simulation, following a population of scattering hot electrons, indicate a localized high power deposited to the chamber wall consistent with the hole formation process. Finally, a hypervapotron cooling scheme is proposed to mitigate the hole formation in electron cyclotron resonance plasma chamber wall.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerogel Cherenkov detector for characterizing the intense flash x-ray source, Cygnus, spectrum

An aerogel Cherenkov detector is proposed to measure the X-ray energy spectrum from the Cygnus—intense flash X-ray source operated at the Nevada National Security Site. An array of aerogels set at a variety of thresholds between 1 and 3 MeV will be adequate to map out the bremsstrahlung X-ray production of the Cygnus, where the maximum energy of the spectrum is normally around 2.5 MeV. In addition to the Cherenkov radiation from aerogels, one possible competing light-production mechanism is optical transition radiation (OTR), which may be significant in aerogels due to the large number of transitions from SiO{sub 2} clusters to vacuum voids. To examine whether OTR is a problem, four aerogel samples were tested using a mono-energetic electron beam (varied in the range of 1–3 MeV) at NSTec Los Alamos Operations. It was demonstrated that aerogels can be used as a Cherenkov medium, where the rate of the light production is about two orders magnitude higher when the electron beam energy is above threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-accuracy {sup 233}U(n,f) cross-section measurement at the white-neutron source n{sub T}OF from near-thermal to 1 MeV neutron energy

The {sup 233}U(n,f) cross section has been measured at the white neutron source n{sub T}OF in a wide energy range with a dedicated fission ionization chamber. We report here the results from {approx}30 meV to 1 MeV neutron energy. The {sup 233}U(n,f) cross section has been determined relative to a reference sample of {sup 235}U(n,f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n{sub T}OF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross section by means of R-matrix analysis over a wide energy range. The results are, in general, in good agreement with the most recent high-accuracy measurement of this fission cross section, over the more limited range of the previous measurements, and indicated that even the latest evaluations underestimate the cross section in the epithermal region. The present high-quality data provide the basis for a more precise evaluation of the {sup 233}U fission cross section and for improving the reliability of databases needed for the design of new energy systems based on the Th/U cycle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Regulation of Renewable Energy Sources to Optimal Power Flow Solutions Using ADMM

This paper considers power distribution systems featuring renewable energy sources (RESs), and develops a distributed optimization method to steer the RES output powers to solutions of AC optimal power flow (OPF) problems. The design of the proposed method leverages suitable linear approximations of the AC-power flow equations, and is based on the Alternating Direction Method of Multipliers (ADMM). Convergence of the RES-inverter output powers to solutions of the OPF problem is established under suitable conditions on the stepsize as well as mismatches between the commanded setpoints and actual RES output powers. In a broad sense, the methods and results proposed here are also applicable to other distributed optimization problem setups with ADMM and inexact dual updates.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Test of High Efficiency Residential Buildings with Ground-source and Air-source Heat Pump Systems

This paper describes the field performance of space conditioning and water heating equipment in four single-family residential structures with advanced thermal envelopes. Each structure features a different, advanced thermal envelope design: structural insulated panel (SIP); optimum value framing (OVF); insulation with embedded phase change materials (PCM) for thermal storage; and exterior insulation finish system (EIFS). Three of the homes feature ground-source heat pumps (GSHPs) for space conditioning and water heating while the fourth has a two-capacity air-source heat pump (ASHP) and a heat pump water heater (HPWH). Two of the GCHP-equipped homes feature horizontal ground heat exchange (GHX) loops that utillize the existing foundation and utility service trenches while the third features a vertical borehole with vertical u-tube GHX. All of the houses were operated under the same simulated occupancy conditions. Operational data on the house HVAC/Water heating (WH) systems are presented and factors influencing overall performance are summarized.

air-source heat pumps↗

An independent analysis of bias sources and variability in wind plant pre-construction energy yield estimation methods

The wind resource assessment community has long had the goal of reducing the bias between wind plant pre-construction energy yield assessment (EYA) and the observed annual energy production (AEP). This comparison is typically made between the 50% probability of exceedance (P50) value of the EYA and the long-term corrected operational AEP (hereafter OA P50), and is known as the P50 bias. The industry has critically lacked an independent analysis of bias reduction investigated across multiple consultants to identify the greatest sources of uncertainty and variance in the EYA process and the best opportunities for uncertainty reduction. The present study addresses this gap by benchmarking consultant methodologies against each other and against operational data at a scale not seen before in industry collaborations. We consider data from 10 wind plants and evaluate discrepancies between eight consultancies in the steps taken from estimates of gross to net energy. Consultants tend to overestimate the gross energy produced at the turbines and then compensate by further overestimating downstream losses, leading to a mean P50 bias near zero, still with significant variability among the individual wind plants. Within our data sample, we find that consultant estimates of all loss categories, except environmental losses, tend to reduce the project-to-project variability of the P50 bias. The disagreement between consultants, however, remains flat throughout the addition of losses. Finally, we find that differences in consultants’ estimates of project performance can lead to differences up to $10/MWh in the levelized cost of energy for a wind plant.

Todd, Austin C.↗

Atmospheric mercury in Changbai Mountain area, northeastern China I. The seasonal distribution pattern of total gaseous mercury and its potential sources

An intensive field campaign for the measurement of total gaseous mercury (TGM) concentrations in ambient air was conducted in Changbai Mountain area from 5 August 2005 to 5 July 2006 using an automatic atmospheric mercury analyzer (Tekran 2537A), which was the first time TGM was monitored at a remote area in northeastern China. 99% of the hourly TGM concentrations fell between 1.28 and 9.49 ng m{sup -3} with an annual arithmetic mean of 3.58 {+-} 1.78 ng m{sup -3}, which was significantly elevated compared to values obtained in remote areas of Europe and North America. Seasonal mean TGM concentrations displayed a descending trend as follows: winter, spring, fall, and summer. Compared to spring/winter, TGM concentrations were lower in the summer/fall but the standard deviation (SD) of TGM levels was higher and indicated a correlation with anthropogenic emissions. TGM concentrations showed seasonal differences with respect to meteorological parameters: TGM levels in spring/winter were most correlated with wind speed, and correlated with solar radiation only in the winter, while TGM levels in summer/fall periods were most correlated with air temperature. There was a strong diurnal variation of seasonal TGM with significantly higher concentrations in daytime/nighttime compared to the early morning. The seasonal diel TGM pattern indicated regional biofuel and coal combustion were the primary mercury sources.

01 COAL, LIGNITE, AND PEAT↗

Deduction of edge electron density with multiply charged ions in ORNL volume-type electron cyclotron resonance ion source

The electron densities in the argon plasmas of the ORNL 6 GHz electron cyclotron resonance (ECR) ion source with a flat central magnetic field have been deduced from the ion branches of the electric probe current-voltage curves measured in the edge region of the plasmas. To overcome the difficulties due to unknown velocities of multiply charged ions at the sheath edge, a modified generalized Bohm criterion for the ion sheath velocity is introduced and the mean velocity of all ionic charge states at the sheath edge is assumed to be equal to the sound velocity of the system of particles. The calculated electron densities and temperatures for different plasmas optimized for four charge state distributions are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Summary Report of PESP2008 - The Workshop on Polarized Electron Sources and Polarimeters

The Workshop on Polarized Electron Sources and Polarimeters (PESP2008) was hosted by Jefferson Lab October 1-3, 2008, in association with SPIN2008, continuing a tradition since 1983. The workshop was well attended with 84 registrants, 38 oral presentations and 17 posters. The usual topics were covered: DC and RF photoguns, high voltage issues, photocathodes, drive lasers, vacuum and polarimetry. Detailed accounts of each contribution (oral and poster) appear within these Proceedings. This submission summarizes some of the highlights of the workshop.

43 PARTICLE ACCELERATORS↗

Optimizing the operation of a high resolution vertical Johann spectrometer using a high energy fluorescer x-ray source

This paper describes the operation and testing for a vertical Johann spectrometer (VJS) operating in the 13 keV range. The spectrometer is designed to use thin curved mica crystals or thick germanium crystals. The VJS must have a resolution of E/{Delta}E=3000 or better to measure the Doppler broadening of highly ionized krypton and operate at a small x-ray angle in order to be used as a diagnostic in a laser plasma target chamber. The VJS was aligned, tested, and optimized using a fluorescer type high energy x-ray (HEX) source located at National Security Technologies (NSTec), LLC, in Livermore, CA. The HEX uses a 160 kV x-ray tube to excite fluorescence from various targets. Both rubidium and bismuth fluorescers were used for this effort. This presentation describes the NSTec HEX system and the methods used to optimize and characterize the VJS performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and operation of the wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source

The wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source (SNS) is optimized to provide a high neutron flux at the sample position with a large solid angle of detector coverage. The instrument incorporates modern neutron instrumentation, such as an elliptically focused neutron guide, high speed magnetic bearing choppers, and a massive array of {sup 3}He linear position sensitive detectors. Novel features of the spectrometer include the use of a large gate valve between the sample and detector vacuum chambers and the placement of the detectors within the vacuum, both of which provide a window-free final flight path to minimize background scattering while allowing rapid changing of the sample and sample environment equipment. ARCS views the SNS decoupled ambient temperature water moderator, using neutrons with incident energy typically in the range from 15 to 1500 meV. This range, coupled with the large detector coverage, allows a wide variety of studies of excitations in condensed matter, such as lattice dynamics and magnetism, in both powder and single-crystal samples. Comparisons of early results to both analytical and Monte Carlo simulation of the instrument performance demonstrate that the instrument is operating as expected and its neutronic performance is understood. ARCS is currently in the SNS user program and continues to improve its scientific productivity by incorporating new instrumentation to increase the range of science covered and improve its effectiveness in data collection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source effects in analyzer-based X-ray phase contrast imaging with conventional sources

Several recent papers have shown the implementation of analyzer based X-ray phase contrast imaging (ABI) with conventional X-ray sources. The high flux is always a requirement to make the technique useful for bio-medical applications. Here, we present and discuss three important parameters, which need to be taken into account, when searching for the high flux ABI: anisotropic magnification, double image, and source size spread due to intrinsic dispersive diffraction by asymmetrically cut crystals. These parameters, if not well optimized, may cause important features in the acquired images which can mislead the interpretation. A few ways to minimize these effects are implemented and discussed, including some experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A large-acceptance beam-deceleration module for retrofitting into ion-source beam lines

We describe a large-acceptance deceleration module capable of decelerating large-emittance full-intensity ion beams typical of ECR ion sources to very low energies with high efficiency. The deceleration module is designed to permit convenient retrofitting into an existing beam line to replace, e.g., the first Faraday cup after magnetic analysis of the beam extracted from the ion source. For starting energies of 10 keV, and incident ion currents as large as 300 {mu}A, deceleration efficiencies have been measured to be greater than 80% for final energies as low as 70 eV. The decelerated beam intensity can be monitored either by insertion of a beam catcher floating at the final deceleration voltage or from the current to the exit grid itself, with suitable correction applied for the grid transparency factor. The behavior of the deceleration optics was modeled using SIMION, incorporating the effects of intra-beam space charge repulsion. We describe a recent application of this deceleration module to study near-surface He bubble and blister formation of a W target heated to 1250 K and irradiated with a 98 eV He ion beam with a flux of {approx}10{sup 16} cm{sup -2} s{sup -1}.

43 PARTICLE ACCELERATORS↗