Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Laser beam coupling with capillary discharge plasma for laser wakefield acceleration applications

One of the most robust approaches, demonstrated to date, of accelerating electron beams by laser-plasma sources is the utilization of plasma channels generated by the capillary discharges. Although the spatial structure of the installation is simple in principle, there may be some important effects caused by the open ends of the capillary, by the supplying channels etc., which require a detailed 3D modeling of the processes. In the present work, such simulations are performed using the code MARPLE. First, the process of capillary filling with cold hydrogen before the discharge is fired, through the side supply channels is simulated. Second, the simulation of the capillary discharge is performed with the goal to obtain a time-dependent spatial distribution of the electron density near the open ends of the capillary as well as inside the capillary. Lastly, to evaluate the effectiveness of the beam coupling with the channeling plasma wave guide and of the electron acceleration, modeling of the laser-plasma interaction was performed with the code INF&RNO.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Monte Carlo synthetic-acceleration method for solving the thermal radiation diffusion equation

We present a novel synthetic-acceleration-based Monte Carlo method for solving the equilibrium thermal radiation diffusion equation in three spatial dimensions. The algorithm performance is compared against traditional solution techniques using a Marshak benchmark problem and a more complex multiple material problem. Our results show that our Monte Carlo method is an effective solver for sparse matrix systems. For solutions converged to the same tolerance, it performs competitively with deterministic methods including preconditioned conjugate gradient and GMRES. We also discuss various aspects of preconditioning the method and its general applicability to broader classes of problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gluon condensate, modified gravity, and the accelerating Universe

It has been suggested recently to study the dynamics of a gravitating gluon condensate q in the context of a spatially flat Friedmann-Robertson-Walker universe. The expansion of the Universe (or, more generally, the presence of a nonvanishing Ricci curvature scalar R) perturbs the gluon condensate and may induce a nonanalytic term h-tilde(R,q) in the effective gravitational action. The aim of this article is to explore the cosmological implications of a particular nonanalytic term h-tilde{proportional_to}{eta}|R|{sup 1/2}|q|{sup 3/4}. With a quadratic approximation of the gravitating gluon-condensate vacuum energy density {rho}{sub V}(q) near the equilibrium value q{sub 0} and a small coupling constant {eta} of the modified-gravity term h-tilde, an 'accelerating universe' is obtained which resembles the present Universe, both qualitatively and quantitatively. The unknown component X of this model universe (here, primarily due to modified-gravity effects) has an effective equation-of-state parameter w{sub X} which is found to evolve toward the value -1 from above.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-Z target optimization for spatial resolution improvement in megavoltage imaging

Purpose: Recently, several authors have shown contrast improvements in megavoltage portal imaging and cone-beam computed tomography using low atomic number (Z) targets. This work compliments previous studies by investigating the effects of varying different beam production parameters including target atomic number, target thickness, and incident electron energy on spatial resolution. Methods: Target materials of beryllium, aluminum, and tungsten were investigated over a range of thicknesses between 10% and 100% of the continuous slowing down approximation range of electrons. Incident electron kinetic energies of 4.5 and 7.0 MeV were used, in conjunction with custom targets installed above the carousel of a modern radiotherapy linear accelerator. Monte Carlo simulations of the accelerator were constructed and compared to the experimental results. Results: The results showed that thinner targets, as well higher incident electron energies, generally produce more favorable modulation transfer function (MTF) curves. Due to an MTF dependence of the detector system on the photon energy, the experimental results showed that low-Z targets produced superior MTF curves. Simulations showed 14.5% and 21.5% increases in f{sub 50} for the 7.0 and 4.5 MeV targets (Al; 60%R{sub %CSDA}), respectively, when moved from the carousel to the location of the clinical target. f{sub 50} values for the custom targets were compared to the clinical 6 MV beam and were found to be between 10.4% lower (4.5 MeV/W) and 15.5% higher (7.0 MeV/Be). Conclusions: Integration of low-Z external targets into the treatment head of a medical linear was achieved with only minor modifications. It was shown that reasonably high resolution images on par or better than those acquired with the clinical 6 MV beam can be achieved using external low-Z targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-04: Improving CT Quality for Radiation Therapy of Patients with High Body Mass Index Using Iterative Reconstruction Algorithms

Purpose: Iterative reconstruction (IR) algorithms are developed to improve CT image quality (IQ) by reducing noise without diminishing spatial resolution or contrast. The CT IQ for patients with a high Body Mass Index (BMI) can suffer from increased noise due to photon starvation. The purpose of this study is to investigate and to quantify the IQ enhancement for high BMI patients through the application of IR algorithms. Methods: CT raw data collected for 6 radiotherapy (RT) patients with BMI, greater than or equal to 30 were retrospectively analyzed. All CT data were acquired using a CT scanner (Somaton Definition AS Open, Siemens) installed in a linac room (CT-on-rails) using standard imaging protocols. The CT data were reconstructed using the Sinogram Affirmed Iterative Reconstruction (SAFIRE) and Filtered Back Projection (FBP) methods. IQ metrics of the obtained CTs were compared and correlated with patient depth and BMI. The patient depth was defined as the largest distance from anterior to posterior along the bilateral symmetry axis. Results: IR techniques are demonstrated to preserve contrast and reduce noise in comparison to traditional FBP. Driven by the reduction in noise, the contrast to noise ratio is roughly doubled by adopting the highest SAFIRE strength. A significant correlation was observed between patient depth and IR noise reduction through Pearson’s correlation test (R = 0.9429/P = 0.0167). The mean patient depth was 30.4 cm and the average relative noise reduction for the strongest iterative reconstruction was 55%. Conclusion: The IR techniques produce a measureable enhancement to CT IQ by reducing the noise. Dramatic noise reduction is evident for the high BMI patients. The improved CT IQ enables more accurate delineation of tumors and organs at risk and more accuarte dose calculations for RT planning and delivery guidance. Supported by Siemens.

60 APPLIED LIFE SCIENCES↗

Photocathode Laser Shaping for High Transformer Ratio Collinear Wakefield Acceleration

Beam-driven wakefield acceleration is one of the most promising advanced accelerator concepts. With this approach, the main beam is accelerated by absorbing the energy from a drive beam, which has a lower kinetic energy, but a much higher current. For efficient acceleration, it is important to shape the drive beam axially, to increase the so-called transformer ratio: the energy gain by the main beam over the energy loss of the drive beam. In most cases, the drive beam shaping is done with the help of beam phase space manipulations, along with removing portions of the beam with a scraper. Such shaping is complicated by itself, causing charge loss and thermal heating, but can also lead to beam instabilities, due to the alteration of the beam phase space. How the problem is being addressed: In this project, Euclid Techlabs proposes to reduce the complexity of this process by shaping the laser beam incident on the photocathode instead of the electron beam itself. This approach yields an additional “tuning knob” for shaping the electron beam. The photocathode laser pulse can be modified to have the desired longitudinal profile, which will result in the desired profile of the electron beam after acceleration in the photoinjector. Laser shaping is, in fact, analogous to previous electron beam shaping approaches. A chirped beam is passed through a dispersive element (spatial light modulator), and masked to achieve the desired shape.

43 PARTICLE ACCELERATORS↗

Absolute Bunch Length Measurements by Incoherent Radiation Fluctuation Analysis

By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

43 PARTICLE ACCELERATORS↗

Magnetically assisted self-injection and radiation generation for plasma-based acceleration

In this work, it is shown through analytical modeling and numerical simulations that external magnetic fields can relax the self-trapping thresholds in plasma-based accelerators. In addition, the transverse location where self-trapping occurs can be selected by adequate choice of the spatial profile of the external magnetic field. We also find that magnetic-field assisted self-injection can lead to the emission of betatron radiation at well-defined frequencies. This controlled injection technique could be explored using state-of-the-art magnetic fields in current/next generation plasma/laser wakefield accelerator experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prospects for Cherenkov Telescope Array Observations of the Young Supernova Remnant RX J1713.7−3946

We perform simulations for future Cherenkov Telescope Array (CTA) observations of RX J1713.7−3946, a young supernova remnant (SNR) and one of the brightest sources ever discovered in very high energy (VHE) gamma rays. Special attention is paid to exploring possible spatial (anti)correlations of gamma rays with emission at other wavelengths, in particular X-rays and CO/H i emission. We present a series of simulated images of RX J1713.7−3946 for CTA based on a set of observationally motivated models for the gamma-ray emission. In these models, VHE gamma rays produced by high-energy electrons are assumed to trace the nonthermal X-ray emission observed by XMM-Newton , whereas those originating from relativistic protons delineate the local gas distributions. The local atomic and molecular gas distributions are deduced by the NANTEN team from CO and H i observations. Our primary goal is to show how one can distinguish the emission mechanism(s) of the gamma rays (i.e., hadronic versus leptonic, or a mixture of the two) through information provided by their spatial distribution, spectra, and time variation. This work is the first attempt to quantitatively evaluate the capabilities of CTA to achieve various proposed scientific goals by observing this important cosmic particle accelerator.

79 ASTRONOMY AND ASTROPHYSICS↗

Morphology and hardness ratio exploitation under limited statistics

{gamma}-ray astronomy has produced for several years now sky maps for low photon statistics, non-negligible background and comparatively poor angular resolution. Quantifying the significance of spatial features remains difficult. Besides, spectrum extraction requires regions with large statistics while maps in energy bands allow only qualitative interpretation. The two main competing mechanisms in the VHE domain are the Inverse-Compton emission from accelerated electrons radiating through synchrotron in the X-ray domain and the interactions between accelerated hadrons and the surrounding medium, leading to the production and subsequent decay of {pi}{sup 0} mesons. The spectrum of the VHE emission from leptons is predicted to steepen with increasing distance from the acceleration zone, owing to synchrotron losses (i.e. cooled population). It would remain approximately constant for hadrons.Ideally, spectro-imaging analysis would have the same spatial scale in the TeV and X-ray domains, to distinguish the local emission mechanisms. More realistically, we investigate here the possibility of improving upon the currently published HESS results by using more sophisticated tools.

79 ASTRONOMY AND ASTROPHYSICS↗

The High Energy X-ray Probe (HEX-P): supernova remnants, pulsar wind nebulae, and nuclear astrophysics

HEX-P is a probe-class mission concept that will combine high spatial resolution X-ray imaging (< 10" full width at half maximum) and broad spectral coverage (0.2–80 keV) with an effective area far superior to current facilities (including XMM-Newton and NuSTAR) to enable revolutionary new insights into a variety of important astrophysical problems. HEX-P is ideally suited to address important problems in the physics and astrophysics of supernova remnants (SNRs) and pulsar wind nebulae (PWNe). For shell SNRs, HEX-P can greatly improve our understanding via more accurate spectral characterization and localization of non-thermal X-ray emission from both non-thermal-dominated SNRs and those containing both thermal and non-thermal components, and can discover previously unknown non-thermal components in SNRs. Multi-epoch HEX-P observations of several young SNRs (e.g., Cas A and Tycho) are expected to detect year-scale variabilities of X-ray filaments and knots, thus enabling us to determine fundamental parameters related to diffusive shock acceleration, such as local magnetic field strengths and maximum electron energies. For PWNe, HEX-P will provide spatially-resolved, broadband X-ray spectral data separately from their pulsar emission, allowing us to study how particle acceleration, cooling, and propagation operate in different evolution stages of PWNe. HEX-P is also poised to make unique and significant contributions to nuclear astrophysics of Galactic radioactive sources by improving detections of, or limits on, 44Ti in the youngest SNRs and by potentially discovering rare nuclear lines as evidence of double neutron star mergers. Throughout the paper, we present simulations of each class of objects, demonstrating the power of both the imaging and spectral capabilities of HEX-P to advance our knowledge of SNRs, PWNe, and nuclear astrophysics.

79 ASTRONOMY AND ASTROPHYSICS↗

Areal density and spatial resolution of high energy electron radiography

Ultrafast imaging tools are of great importance for determining the dynamic density distribution in high energy density (HED) matter. In this work, we designed a high energy electron radiography (HEER) system based on a linear electron accelerator to evaluate its capability for imaging HED matter. 40 MeV electron beams were used to image an aluminum target to study the density resolution and spatial resolution of HEER. The results demonstrate a spatial resolution of tens of micrometers. The interaction of the beams with the target and the beam transport of the transmitted electrons are further simulated with EGS5 and PARMELA codes, with the results showing good agreement with the experimental resolution. Furthermore, the experiment can be improved by adding an aperture at the Fourier plane.

areal density resolution↗

Studies of the 3D structure of the proton at Jlab

In recent years parton distributions, describing longitudinal momentum, helicity and transversity distributions of quarks and gluons, have been generalized to account also for transverse degrees of freedom. Two new sets of more general distributions, Transverse Momentum Distributions (TMDs) and Generalized Parton Distributions (GPDs) were introduced to describe transverse momentum and spatial distributions of partons. Great progress has been made since then in measurements of different Single Spin Asymmetries (SSAs) in semi-inclusive and hard exclusive processes, providing access to TMDs and GPDs, respectively. Studies of TMDs and GPDs are also among the main driving forces of the JLab 12 GeV upgrade project.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronic structure at coarse-grained resolutions from supervised machine learning

Computational studies aimed at understanding conformationally dependent electronic structure in soft materials require a combination of classical and quantum-mechanical simulations, for which the sampling of conformational space can be particularly demanding. Coarse-grained (CG) models provide a means of accessing relevant time scales, but CG configurations must be back-mapped into atomistic representations to perform quantum-chemical calculations, which is computationally intensive and inconsistent with the spatial resolution of the CG models. A machine learning approach, denoted as artificial neural network electronic coarse graining (ANN-ECG), is presented here in which the conformationally dependent electronic structure of a molecule is mapped directly to CG pseudo-atom configurations. By averaging over decimated degrees of freedom, ANN-ECG accelerates simulations by eliminating backmapping and repeated quantum-chemical calculations. The approach is accurate, consistent with the CG spatial resolution, and can be used to identify computationally optimal CG resolutions.

36 MATERIALS SCIENCE↗

Using Nanofiller Assemblies to Control the Crystallization Kinetics of High-Density Polyethylene

Polyethylene-grafted nanoparticles (NPs) are organized into a variety of assemblies in a polydisperse polyethylene melt by tailoring the graft density and molecular weights of the graft chains. Under these conditions we systematically vary NP assemble state and study is consequences on crystal nucleation and growth rates. We find that the nucleation rate is suppressed below that of the unfilled polymer for good NP spatial dispersion. However, poorer dispersion, which leads to the formation of NP assemblies, can accelerate nucleation likely by providing multiple heterogenous sites due to topographical features. We find that a key parameter, the chain overcrowding in the brush, can predict these nucleation trends – in this language, the most enhanced nucleation rate is found when the grafts are the most overcrowded, and hence the least interpenetrated with the matrix chains. This result is consistent with one other literature result which utilized short crystallizable polyethylene glycol grafts in short PEO matrices. The growth kinetics were retarded for all nanocomposites, their temperature dependences were essentially equal to that for the pure polymer (in the absence of NPs) – the NPs thus do not affect secondary nucleation, indicating that the transport of the matrix to the growth front is the rate determining step. Thus, evidently the increase in matrix viscosity, or reduction in growth rates, is directly determined by the agglomeration state of the NPs. These results are consistent with past works with bare silica NPs in PEO, and with silica NPs grafted with amorphous chains in a PEO matrix, suggesting that growth kinetics in these systems apparently follow “universal” behavior. Additionally, there are initial hints that the ratio of the effective surface area of the NP clusters per unit matrix volume provides a unified description of the NP induced confinement that slows growth kinetics. Furthermore, our work thus shows that there is an evolving understanding of the role of NPs on crystallization kinetics, in particular crystal growth where trends appear to be independent of the grafts ability to crystallize.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct observation of pitting corrosion evolutions on carbon steel surfaces at the nano-to-micro- scales

The Cl¯-induced corrosion of metals and alloys is of relevance to a wide range of engineered materials, structures, and systems. Because of the challenges in studying pitting corrosion in a quantitative and statistically significant manner, its kinetics remain poorly understood. Herein, by direct, nano- to micro-scale observations using vertical scanning interferometry (VSI), we examine the temporal evolution of pitting corrosion on AISI 1045 carbon steel over large surface areas in Cl¯-free, and Cl¯-enriched solutions. Special focus is paid to examine the nucleation and growth of pits, and the associated formation of roughened regions on steel surfaces. By statistical analysis of hundreds of individual pits, three stages of pitting corrosion, namely, induction, propagation, and saturation, are quantitatively distinguished. By quantifying the kinetics of these processes, we contextualize our current understanding of electrochemical corrosion within a framework that considers spatial dynamics and morphology evolutions. In the presence of Cl¯ ions, corrosion is highly accelerated due to multiple autocatalytic factors including destabilization of protective surface oxide films and preservation of aggressive microenvironments within the pits, both of which promote continued pit nucleation and growth. Furthermore these findings offer new insights into predicting and modeling steel corrosion processes in mid-pH aqueous environments

36 MATERIALS SCIENCE↗

Quantum corrections to the Larmor radiation formula in scalar electrodynamics

We use the semiclassical approximation in perturbative scalar quantum electrodynamics to calculate the quantum correction to the Larmor radiation formula to first order in Planck's constant in the nonrelativistic approximation, choosing the initial state of the charged particle to be a momentum eigenstate. We calculate this correction in two cases: in the first case the charged particle is accelerated by a time-dependent but space-independent vector potential whereas in the second case it is accelerated by a time-independent vector potential which is a function of one spatial coordinate. We find that the corrections in these two cases are different even for a charged particle with the same classical motion. The correction in each case turns out to be nonlocal in time in contrast to the classical approximation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frame average optimization of cine-mode EPID images used for routine clinical in vivo patient dose verification of VMAT deliveries

Purpose: The in vivo 3D dose delivered to a patient during volumetric modulated arc therapy (VMAT) delivery can be calculated using electronic portal imaging device (EPID) images. These images must be acquired in cine-mode (i.e., “movie” mode) in order to capture the time-dependent delivery information. The angle subtended by each cine-mode EPID image during an arc can be changed via the frame averaging number selected within the image acquisition software. A large frame average number will decrease the EPID’s angular resolution and will result in a decrease in the accuracy of the dose information contained within each image. Alternatively, less EPID images acquired per delivery will decrease the overall 3D patient dose calculation time, which is appealing for large-scale clinical implementation. Therefore, the purpose of this study was to determine the optimal frame average value per EPID image, defined as the highest frame averaging that can be used without an appreciable loss in 3D dose reconstruction accuracy for VMAT treatments. Methods: Six different VMAT plans and six different SBRT-VMAT plans were delivered to an anthropomorphic phantom. Delivery was carried out on a Varian 2300ix model linear accelerator (Linac) equipped with an aS1000 EPID running at a frame acquisition rate of 7.5 Hz. An additional PC was set up at the Linac console area, equipped with specialized frame-grabber hardware and software packages allowing continuous acquisition of all EPID frames during delivery. Frames were averaged into “frame-averaged” EPID images using MATLAB. Each frame-averaged data set was used to calculate the in vivo dose to the patient and then compared to the single EPID frame in vivo dose calculation (the single frame calculation represents the highest possible angular resolution per EPID image). A mean percentage dose difference of low dose (<20% prescription dose) and high dose regions (>80% prescription dose) was calculated for each frame averaged scenario for each plan. The authors defined their unacceptable loss of accuracy as no more than a ±1% mean dose difference in the high dose region. Optimal frame average numbers were then determined as a function of the Linac’s average gantry speed and the dose per fraction. Results: The authors found that 9 and 11 frame averages were suitable for all VMAT and SBRT-VMAT treatments, respectively. This resulted in no more than a 1% loss to any of the dose region’s mean percentage difference when compared to the single frame reconstruction. The optimized number was dependent on the treatment’s dose per fraction and was determined to be as high as 14 for 12 Gy/fraction (fx), 15 for 8 Gy/fx, 11 for 6 Gy/fx, and 9 for 2 Gy/fx. Conclusions: The authors have determined an optimal EPID frame averaging number for multiple VMAT-type treatments. These are given as a function of the dose per fraction and average gantry speed. These optimized values are now used in the authors’ clinical, 3D, in vivo patient dosimetry program. This provides a reduction in calculation time while maintaining the authors’ required level of accuracy in the dose reconstruction.

61 RADIATION PROTECTION AND DOSIMETRY↗