Search NASA⌕ Search

SEARCH · Search NASA

Results for “static testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

WE-AB-201-04: The Recommendations of MPPG #5 and Practical Implementation Strategies

Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar defects in the future. Finally, the Gamma test has become a popular metric for reporting TPS Commissioning and QA results. It simplifies complex testing into a numerical index, but noisy data and casual application can make it misleading. A brief review of the issues around the use of the Gamma test will be presented. TPS commissioning and QA: A process orientation and application of control charts (Michael Sharpe) A framework for commissioning a treatment planning system will be presented, focusing on preparations, practical aspects of configuration, priorities, specifications, and establishing performance. The complexity of the modern TPS make modular testing of features inadequate, and modern QA tools can provide “too much information” about the performance of techniques like IMRT and VMAT. We have adopted a process orientation and quality tools, like control charts, for ongoing TPS QA and assessment of patient-specific tests. The trending nature of these tools reveals the overall performance of the TPS system, and quantifies the variations that arise from individual plans, discrete calculations, and experimentation based on discrete measurements. Examples demonstrating application of these tools to TPS QA will be presented. TPS commissioning and QA: Incorporating the entire planning process (Sasa Mutic) The TPS and its features do not perform in isolation. Instead, the features and modules are key components in a complex process that begins with CT Simulation and extends to treatment delivery, along with image guidance and verification. Most importantly, the TPS is used by people working in a multi-disciplinary environment. It is very difficult to predict the outcomes of human interactions with software. Therefore, an interdisciplinary approach to training, commissioning and QA will be presented, along with an approach to the physics chart check and end-to-end testing as a tool for TPS QA. The role of standardization and automation in QA will also be discussed. The recommendations of MPPG #5 and practical implementation strategies (Jennifer Smilowitz) The recently published recommendations from Task Group No. 244, Medical Physics Practice Guideline on Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams will be presented. The recommendations focus on the validation of commissioning data and dose calculations. Tolerance values for non-IMRT beam configurations are summarized based on established criteria and data collected by the IROC. More stringent evaluation criteria for IMRT dose calculations are suggested to test the limitations of the TPS dose algorithms for advanced delivery conditions. The MPPG encourages users to create a suite of validation tests for dose calculation for various conditions for static photon beams, heterogeneities, IMRT/VMAT and electron beams. This test suite is intended to be used for subsequent testing, including TPS software upgrades. In the past, the recommendations of some reports have not been widely implemented due to practical limitations. Implementation strategies, tools and processes developed by multiple centers for efficient and “do-able” MPPG #5 testing will be presented, as well as a discussion on the overall validation experience. Learning Objectives: Identify some of the key documents relevant for TPS commissioning and QA Understand strategies for testing TPS software Gain a practical knowledge of the Gamma test criteria Increase familiarity with the process of commissioning a TPS Learn about the use of Control Charts for TPS QA Review the role of the TPS in the overall planning process Increase awareness of the link between TPS QA and chart checking Gain an increased appreciation for the importance of interdisciplinary communication Understand the new recommendations from MPPG #5 on TPS Dose Algorithm Commissioning and QC/QA Learn practical implementation processes and tools for MPPG #5 validation recommendations.

60 APPLIED LIFE SCIENCES↗

Advanced Composite Wind Turbine Blade Design Based on Durability and Damage Tolerance

The objective of the program was to demonstrate and verify Certification-by-Analysis (CBA) capability for wind turbine blades made from advanced lightweight composite materials. The approach integrated durability and damage tolerance analysis with robust design and virtual testing capabilities to deliver superior, durable, low weight, low cost, long life, and reliable wind blade design. The GENOA durability and life prediction software suite was be used as the primary simulation tool. First, a micromechanics-based computational approach was used to assess the durability of composite laminates with ply drop features commonly used in wind turbine applications. Ply drops occur in composite joints and closures of wind turbine blades to reduce skin thicknesses along the blade span. They increase localized stress concentration, which may cause premature delamination failure in composite and reduced fatigue service life. Durability and damage tolerance (D&DT) were evaluated utilizing a multi-scale micro-macro progressive failure analysis (PFA) technique. PFA is finite element based and is capable of detecting all stages of material damage including initiation and propagation of delamination. It assesses multiple failure criteria and includes the effects of manufacturing anomalies (i.e., void, fiber waviness). Two different approaches have been used within PFA. The first approach is Virtual Crack Closure Technique (VCCT) PFA while the second one is strength-based. Constituent stiffness and strength properties for glass and carbon based material systems were reverse engineered for use in D&DT evaluation of coupons with ply drops under static loading. Lamina and laminate properties calculated using manufacturing and composite architecture details matched closely published test data. Similarly, resin properties were determined for fatigue life calculation. The simulation not only reproduced static strength and fatigue life as observed in the test, it also showed composite damage and fracture modes that resemble those reported in the tests. The results show that computational simulation can be relied on to enhance the design of tapered composite structures such as the ones used in turbine wind blades. A computational simulation for durability, damage tolerance (D&DT) and reliability of composite wind turbine blade structures in presence of uncertainties in material properties was performed. A composite turbine blade was first assessed with finite element based multi-scale progressive failure analysis to determine failure modes and locations as well as the fracture load. D&DT analyses were then validated with static test performed at Sandia National Laboratories. The work was followed by detailed weight analysis to identify contribution of various materials to the overall weight of the blade. The methodology ensured that certain types of failure modes, such as delamination progression, are contained to reduce risk to the structure. Probabilistic analysis indicated that composite shear strength has a great influence on the blade ultimate load under static loading. Weight was reduced by 12% with robust design without loss in reliability or D&DT. Structural benefits obtained with the use of enhanced matrix properties through nanoparticles infusion were also assessed. Thin unidirectional fiberglass layers enriched with silica nanoparticles were applied to the outer surfaces of a wind blade to improve its overall structural performance and durability. The wind blade was a 9-meter prototype structure manufactured and tested subject to three saddle static loading at Sandia National Laboratory (SNL). The blade manufacturing did not include the use of any nano-material. With silica nanoparticles in glass composite applied to the exterior surfaces of the blade, the durability and damage tolerance (D&DT) results from multi-scale PFA showed an increase in ultimate load of the blade by 9.2% as compared to baseline structural performance (without nano). The use of nanoparticles lead to a delay in the onset of delamination. Load-displacement relationships obtained from testing of the blade with baseline neat material were compared to the ones from analytical simulation using neat resin and using silica nanoparticles in the resin. Multi-scale PFA results for the neat material construction matched closely those from test for both load displacement and location and type of damage and failure. AlphaSTAR demonstrated that wind blade structures made from advanced composite materials can be certified with multi-scale progressive failure analysis by following building block verification approach.

17 WIND ENERGY↗

FUEL PERFORMANCE STUDIES AT IDAHO NATIONAL LABORATORY MAKING USE OF THE BYRON FUEL SHIPMENT

In December of 2023 a shipment of commercially irradiated fuel rods from the Byron Generating Station in Illinois was successfully shipped to the Materials and Fuels Complex (MFC) at Idaho National Laboratory (INL). The make-up of the rods includes a mix of cladding types from traditional ZirloTM, advanced zirconium alloys, and chrome coated ZirloTM. Burnups range from regular end of life values to over 70 GWd/MTU rod average. The R&D plan for the rods involves multiple projects from developing licensing data for new claddings to integral transient tests to support burnup extension efforts in the United States. The R&D began in early 2024 with the nondestructive examinations of the rods after which they will be sectioned for microscopy, mechanical testing, and analytical chemistry. Additionally, many rod segments will be refabricated into new test pins and inserted into a static water capsule for integral Reactivity Initiated Accident (RIA) and Loss of Coolant Accident (LOCA) testing at the TREAT reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fracture Resistance of Cast Stainless Steels after Thermal Aging for up to 10000 Hours

This work package, Cast Stainless Steel Aging, aims to achieve a comprehensive scientific understanding on the aging and failure phenomena in cast austenitic stainless steels (CASSs) using holistic experimental and modeling means and to provide a practical and science-based model to predict the degree of thermal degradation of CASS components in extended-term operations. The test materials in the project include four model CASSs (CF3, CF3M, CF8, and CF8M), four EPRI-provided CASSs (CF3, two CF8s, and CF8M), and two reference wrought materials (304L and 316L), which contain a wide variety of d-ferrite contents (2–33%). These materials have been thermally aged at two light water reactor (LWR)-relevant temperatures (290 and 330°C) and at two accelerated-aging temperatures (360 and 400°C) for up to three years. In the fiscal year, the fracture toughness testing and J-R curve calculation were completed for the ten CASS and wrought materials aged up to 10,000 hours. This report is to present the results of the static fracture (J-R) testing for the model and EPRI-provided CASS materials after thermal aging up to 10,000 hours. First, a new aging parameter (A) was defined to present the aging degradation of mechanical properties against the common variable. This definition is used to scale an aging time at a temperature to the effective aging time at a reference temperature based on Arrhenius equation, which is a rate theory equation for thermally activated mechanisms.

36 MATERIALS SCIENCE↗

Material Testing of PH13-8MO H950 Steel for Xue-Wierzbicki Fracture Criterion Determination

Four tensile coupon designs of PH13-8Mo H950 steel were tested to failure using quasi-static rates to obtain data to calibrate the Xue-Wierzbicki failure model for ductile fracture. The tests recorded the force-displacement, location of the first crack, displacement to fracture, area reduction, and crack propagation path. The test method and coupon designs were adopted from Tomasz Wierzbicki’s “Calibration and evaluation of seven fracture models” report. The XueWierzbicki model predicts fracture based on accumulated equivalent plastic strain, stress triaxiality, and deviatoric state parameter. Calibrating the Xue-Wierzbicki failure model required testing four coupon designs to calculate the four free parameters in the model. The coupon designs tested a range of stress triaxialities with two axisymmetric tests, one shear test, and one plane stress test. The data obtained and presented in this report can be used to develop a Xue-Wierzbicki fracture model for PH13-8Mo H950 steel.

36 MATERIALS SCIENCE↗

Evaluation of the Geotech SMART24BH 20Vpp/5Vpp data acquisition system with active fortezza crypto card data signing and authentication.

Sandia National Laboratories has tested and evaluated Geotech SMART24BH borehole data acquisition system with active Fortezza crypto card data signing and authentication. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of two Geotech SMART24BH digitizers with a Fortezza PCMCIA crypto card actively implementing the signing of data packets. The results of this evaluation were compared to relevant specifications provided within manufacturer's documentation notes. The tests performed were chosen to demonstrate different performance aspects of the digitizer under test. The performance aspects tested include determining noise floor, least significant bit (LSB), dynamic range, cross-talk, relative channel-to-channel timing, time-tag accuracy/statistics/drift, analog bandwidth.

99 GENERAL AND MISCELLANEOUS↗

Status of GTA Gear Inspection after Testing in Sodium

The Mechanisms Engineering Test Loop (METL) is an intermediate-scale liquid metal experimental facility that provides purified reactor-grade (R-grade) sodium to various experimental test vessels. In these test vessels, components that are required to operate in an advanced fast reactor can be tested in a prototypical sodium environment. Experiments conducted in METL significantly assist in the development and maturation of systems and components for advanced reactors. The METL facility consists of multiple test segments including: a purification and diagnostic loop (cold trap was designed after EBR-II), two 18” diameter test vessels with 150 L capacities capable of operating in static or dynamic flow at 538°C, two 28” diameter test vessels with 644 L capacities capable of operating in static or dynamic flow at 650°C, a 3,180 L dump tank with 21 instrumentation ports, and the infrastructure to expand capacity in the future.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental Investigation of Polymer-Induced Fouling of Heater Tubes in the First-Ever Polymer Flood on Alaska North Slope Part II

A polymer flood pilot has been ongoing in the Schrader Bluff viscous oil reservoir at Milne Point on the Alaska North Slope. The results from the pilot are encouraging. However, a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This work applies a multiexperimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids to determine safe operating conditions. Dynamic scale loop (DSL) tests were conducted to study fouling due to polymer at different skin temperatures (165–350°F) in a dynamic state of fluid flow where the fluids’ flow mimics the residence time of fluids in the heat exchanger of the field pilot. Static deposit tests were also conducted at similar skin temperatures of 165–250°F using a novel experimental apparatus designed and built in-house. It was found that at higher skin temperatures of 250–350°F, tube blocking was observed in the DSL tests, whereas the tests at 165–200°F did not show any tube blocking, even in a more extended test period. The deposit test showed that the deposit rate generally increases with skin temperature, and the presence of polymer aggravates the fouling. The copper tube performs best when the skin temperatures are 165–200°F, while the stainless steel tube performs best at a skin temperature of 250°F. These experiments also manifested the influence of the cloudpoint of the solution as the deposit rate increased significantly when the skin temperature was higher than the solution cloudpoint. The study provides a source of practical guidance to the field operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Update on SIC-Based Inverter Technology

This paper presents a study of silicon carbide (SiC) technology which includes device characterization and modeling, inverter simulation, and test results for several prototype inverters. The static and dynamic characteristics of discrete devices and half bridge modules are presented. Test results of a 55 kW hybrid inverter with SiC Schottky diodes and an 18 kW all-SiC inverter using SiC JFETs and Schottky diodes are demonstrated.

42 ENGINEERING↗

Mechanical Response of Additively Manufactured Stainless Steel 304L Across a Wide Range of Loading Conditions

The mechanical response of additively manufactured (AM) stainless steel 304L has been investigated across a broad range of loading conditions, covering 11 decades of strain rate, and compared with the behaviors of traditional ingot-derived (wrought) material. In general, the AM material exhibits a greater strength and reduced ductility compared with the baseline wrought form. These differences are consistently found from quasi-static and high strain rate tests. A detailed investigation of the microstructure, the defect structure, the phase, and the composition of both forms reveals differences that may contribute to the differing mechanical behaviors. Compared with the baseline wrought material, dense AM stainless steel 304L has a more complex grain structure with substantial sub-structure, a fine dispersion of ferrite, increased dislocation density, oxide dispersions and larger amounts of nitrogen. In-situ neutron diffraction studies conducted during quasi-static loading suggest that the increased strength of AM material is due to its initially greater dislocation density. The flow strength of both forms is correlated with dislocation density through a square root dependence akin to a Taylor-like relationship. Neutron diffraction measurements of lattice strains also correlate with a crystal plasticity finite element simulations of the tensile test. Other simulations predict a significant degree of elastic and plastic anisotropy due to crystallographic texture. Hopkinson tests at higher strain rates $\dot{ε}$ = 500 and 2500 s -1 ) also show a greater strength for AM stainless steel 304L; although, the differences compared with wrought are reduced at higher strain rates. Gas gun impact tests, including reverse ballistic, forward ballistic and spall tests, consistently reveal a larger dynamic strength in the AM material. The Hugoniot Elastic Limit (HEL) of AM SS 304L exceeds that of wrought material although considerable variability is observed with the AM material. Forward ballistic testing demonstrates spall strengths of AM material (3.27 -- 3.91 GPa) that exceed that of the wrought material (2.63 -- 2.88 GPa). The Hugoniot equation-of-state for AM samples matches archived data for this metal alloy.

36 MATERIALS SCIENCE↗

Characterization of Mechanical and Thermal Factors Related to Glovebox Container Water Ingress (Final Report)

This report summarizes tests conducted to quantify water ingress into nuclear material containers when damaged. The damage inflicted is meant to replicate realistic worst-case seismic/fire scenario at the Los Alamos National Laboratory (LANL). Four types (SAVY, Hagan, K-flange, and ROCK) of three-quart containers were subject to drop and then furnace testing. At each stage (as-delivered, post-drop, and post-furnace), water ingress potential was tested by subjecting the containers to a static water column. Key results of these experiments include: • LANL provided two water ingress testing criteria. The first, and most stringent, was a 24 inAq column for a period of one week. These parameters were used for baseline testing on as-delivered containers. The second was a 6 inAq column for a period of two hours. These parameters were used to test containers after impact and furnace testing. • Under the more severe criteria for as-delivered containers, the measured water ingress was: SAVY 7–14 g; Hagan 168–493 g; K-flange 4–5 g; and ROCK 24–280 g of water ingress. • Under the less severe criteria and after drop testing, all containers permitted less than 50 g of water ingress with one exception a ROCK container that had one of three latches release during impact. • Finally, after furnace testing (500°C, 45 minutes), which destroyed the o-ring/gasket materials, and under the same 6 inAq, 2 hr column test, the measured water ingress exceeded 50 g for all but one K-flange and one ROCK container.

42 ENGINEERING↗

Borehole muography of subsurface reservoirs

Imaging subsurface rock formations or geological objects like oil and gas reservoirs, mineral deposits, cavities or even magmatic plumbing systems under active volcanoes has been for many years a major quest of geoscientists. Since these subsurface objects cannot be observed directly, different indirect methods have been developed. These methods are all based on variations of certain physical properties of the subsurface materials that can be detected from the ground surface or from boreholes. To determine the density distribution, a new imaging technique using cosmic-ray muon detectors deployed in a borehole has been developed and a first prototype of a borehole muon detector successfully tested. In addition to providing a static image of the subsurface density in three dimensions (or three-dimensional tomography), borehole muography can also inform on the variations of density with time, which recently became of major importance with the injection of large volumes of fluids, mainly water and CO2, in porous subsurface reservoirs (e.g. aquifer storage and recovery, wastewater disposal, enhanced oil recovery and carbon sequestration). This raises several concerns about the risk of leakage and the mechanical integrity of the reservoirs. Determining the field scale induced displacement of fluids by geophysical methods like muography is thus a priority.This article is part of the Theo Murphy meeting issue 'Cosmic-ray muography'.

58 GEOSCIENCES↗

SU-F-T-459: ArcCHECK Machine QA : Highly Efficient Quality Assurance Tool for VMAT, SRS & SBRT Linear Accelerator Delivery

Purpose: Quality assurance (QA) of complex linear accelerators is critical and highly time consuming. ArcCHECK Machine QA tool is used to test geometric and delivery aspects of linear accelerator. In this study we evaluated the performance of this tool. Methods: Machine QA feature allows user to perform quality assurance tests using ArcCHECK phantom. Following tests were performed 1) Gantry Speed 2) Gantry Rotation 3) Gantry Angle 4)MLC/Collimator QA 5)Beam Profile Flatness & Symmetry. Data was collected on trueBEAM stX machine for 6 MV for a period of one year. The Gantry QA test allows to view errors in gantry angle, rotation & assess how accurately the gantry moves around the isocentre. The MLC/Collimator QA tool is used to analyze & locate the differences between leaf bank & jaw position of linac. The flatness & Symmetry test quantifies beam flatness & symmetry in IEC-y & x direction. The Gantry & Flatness/Symmetry test can be performed for static & dynamic delivery. Results: The Gantry speed was 3.9 deg/sec with speed maximum deviation around 0.3 deg/sec. The Gantry Isocentre for arc delivery was 0.9mm & static delivery was 0.4mm. The maximum percent positive & negative difference was found to be 1.9 % & – 0.25 % & maximum distance positive & negative diff was 0.4mm & – 0.3 mm for MLC/Collimator QA. The Flatness for Arc delivery was 1.8 % & Symmetry for Y was 0.8 % & X was 1.8 %. The Flatness for gantry 0°,270°,90° & 180° was 1.75,1.9,1.8 & 1.6% respectively & Symmetry for X & Y was 0.8,0.6% for 0°, 0.6,0.7% for 270°, 0.6,1% for 90° & 0.6,0.7% for 180°. Conclusion: ArcCHECK Machine QA is an useful tool for QA of Modern linear accelerators as it tests both geometric & delivery aspects. This is very important for VMAT, SRS & SBRT treatments.

43 PARTICLE ACCELERATORS↗

Real-time visualization of dynamic fractures in porcine bones and the loading-rate effect on their fracture toughness

In this work we visualized, in real time, the dynamic fracture behaviors in porcine cortical bone from humerus and porcine trabecular bone from nasal bone at a high loading rate using highspeed synchrotron X-ray phase-contrast imaging (PCI). Dynamic three-point bending loading was applied on notched bone specimens by a modified Kolsky compression bar and images of the entire fracture events were recorded with an ultra-high-speed camera. Experiments at a quasi-static loading rate on material testing system (MTS) were also performed to identify the loading-rate effects on the fracture toughness of the two types of bone. Three-dimensional synchrotron X-ray computed tomography was conducted to examine the initial microstructures in the bone specimens before mechanical loading. At the dynamic loading rate, the onset locations of crack initiation were found to be independent from the bone types. The deleterious effect of dynamic loading rate on bone's fracture toughness was verified in this study and the crack was found to propagate at higher speeds in cortical bone than in trabecular bone. In a comparison of the observed more torturous crack paths at the quasi-static loading rate, cracks in dynamically loaded bone specimens generally followed the paths with less in-plane deflections and out-of-plane twists. However, our experimental results also indicated that, although the extent was diminished at dynamic loading rate, the crack deflections at osteon cement lines still played a role as a major toughening mechanism to dynamic fractures in transversely orientated cortical bone.

60 APPLIED LIFE SCIENCES↗

Microstructural Characterization of In-reactor Corrosion Tested Hastelloy N{sup R} and 316 Stainless Steel

The success of the Molten Salt Reactor Experiment (MSRE) at the Oak Ridge National Laboratory (ORNL) in the period 1950's-70's has rekindled the interested in molten salt-cooled reactors. The most recent form of this type of reactor, the Fluoride salt-cooled High-temperature nuclear Reactors (FHRs) is emerging as a leading reactor concept for the next generation nuclear reactors because it offers, among other benefits, a high degree of passive safety, high thermal efficiency, and low spent fuel. Since 2011, two three-year Integrated Research Projects (IRPs) were awarded by the U. S. Department of Energy (DoE) to the Massachusetts Institute of Technology (MIT) in partnership with the University of California, Berkeley and the University of Wisconsin-Madison to develop a 'path forward' for the development of the FHR. One primary challenge in these projects is to evaluate the corrosion and compatibility of structural alloys in the potential primary coolant of molten Li{sub 2}BeF{sub 4} (FLiBe) salt at 700 deg. C in a neutron irradiation environment. In support of structural materials development for the FHR, the static in-reactor corrosion tests of two promising alloys, nickel-based Hastelloy N{sup R} and 316 stainless steel, in {sup 7}Li-enriched molten FLiBe have been conducted in both metal-lined and graphite crucibles in the MIT nuclear research reactor in 2013. This work focuses on the microstructural characterization of the in-reactor corrosion tested alloys for understanding of their performance in high-temperature molten FLiBe salt. Our preliminary results indicate significant thermal effects, graphite effects, and irradiation effects on the alloys' performance in high-temperature molten FLiBe salt, particularly for the in-reactor corrosion tests. The neutron irradiation induces tritium generation in molten salt which could combine with fluorine ions to form corrosive HF to dramatically attack alloys. Additionally, the neutron irradiation introduces structural defects into alloys which probably alter alloys' corrosion resistivity to high temperature molten FLiBe salt. The effect of graphite on the alloys' corrosion in a nuclear reactor is also possibly different from the out-of-reactor corrosion. All these issues will be better understood by characterizing the microstructure of in-reactor corrosion tested alloy samples in our near future plans. The experimental data in this study provides valuable input for evaluating structural materials performance in the FHR. (authors)

36 MATERIALS SCIENCE↗

Guidance on the Use of Existing ASTM Polymer Testing Standards for ABS Parts Fabricated Using FFF

When evaluating the static mechanical performance of fused filament fabrication (FFF) polymers, researchers have conducted tensile testing using American Society for Testing Materials International (ASTM) D3039 rectangular test specimens and ASTM D638 Type I and Type IV dogbone test specimens. The choice of ASTM D638 versus ASTM D3039 test specimen geometry is usually based on the perceived susceptibility of the ASTM D638 test specimens to failure within the fillet radius. ASTM polymer and plastic tensile test standards define criteria for acceptably tested specimens as requiring failure inside the narrow length (i.e., ASTM D638) or outside of the grips (i.e., ASTM D3039) for the results to be considered acceptable. There has been limited published research regarding the selection of an ASTM test specimen geometry for FFF polymer materials. This study provides evidence-based guidance through the comparison of the mechanical performance and failure acceptance rates of ASTM D3039 and ASTM D638 test specimen geometries, fabricated using FFF acrylonitrile butadiene styrene (ABS). Here, the purpose of the study is to provide guidance on the use of existing ASTM polymer testing standards for additively manufactured polymers. Results indicate there is an inherent benefit to using ASTM D3039 over ASTM D638 Type I and Type IV test specimens for tensile testing. ASTM D3039 test specimens provide the most consistent failure within the test specimen’s gage length, which is attributed to the rectangular design of the test specimen. Results also indicated that, like traditionally manufactured polymer composites, there will be differences in the tensile test results (e.g., ultimate tensile strength, elastic modulus) based on the different cross-sectional areas of the test specimen geometries.

36 MATERIALS SCIENCE↗