Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Evaluation of Radiation Dose and Image Quality for the Varian Cone Beam Computed Tomography System

Purpose: To compare the image quality and dosimetry on the Varian cone beam computed tomography (CBCT) system between software Version 1.4.13 and Version 1.4.11 (referred to as 'new' and 'old' protocols, respectively, in the following text). This study investigated organ absorbed dose, total effective dose, and image quality of the CBCT system for the head-and-neck and pelvic regions. Methods and Materials: A calibrated Farmer chamber and two standard cylindrical Perspex CT dosimetry phantoms with diameter of 16 cm (head phantom) and 32 cm (body phantom) were used to measure the weighted cone-beam computed tomography dose index (CBCTDIw) of the Varian CBCT system. The absorbed dose of different organs was measured in a female anthropomorphic phantom with thermoluminescent dosimeters (TLD) and the total effective dose was estimated according to International Commission on Radiological Protection (ICRP) Publication 103. The dose measurement and image quality were studied for head-and-neck and pelvic regions, and comparison was made between the new and old protocols. Results: The values of the new CBCTDIw head-and-neck and pelvic protocols were 36.6 and 29.4 mGy, respectively. The total effective doses from the new head-and-neck and pelvic protocols were 1.7 and 8.2 mSv, respectively. The absorbed doses of lens for the new 200{sup o} and old 360{sup o} head-and-neck protocols were 3.8 and 59.4 mGy, respectively. The additional secondary cancer risk from daily CBCT might be up to 2.8%. Conclusions: The new Varian CBCT provided volumetric information for image guidance with acceptable image quality and lower radiation dose. This imaging tool gave a better standard for patient daily setup verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large Scale Study of Ligand–Protein Relative Binding Free Energy Calculations: Actionable Predictions from Statistically Robust Protocols

The accurate and reliable prediction of protein–ligand binding affinities can play a central role in the drug discovery process as well as in personalized medicine. Of considerable importance during lead optimization are the alchemical free energy methods that furnish an estimation of relative binding free energies (RBFE) of similar molecules. Recent advances in these methods have increased their speed, accuracy, and precision. This is evident from the increasing number of retrospective as well as prospective studies employing them. However, such methods still have limited applicability in real-world scenarios due to a number of important yet unresolved issues. Here, we report the findings from a large data set comprising over 500 ligand transformations spanning over 300 ligands binding to a diverse set of 14 different protein targets which furnish statistically robust results on the accuracy, precision, and reproducibility of RBFE calculations. We use ensemble-based methods which are the only way to provide reliable uncertainty quantification given that the underlying molecular dynamics is chaotic. These are implemented using TIES (Thermodynamic Integration with Enhanced Sampling). Results achieve chemical accuracy in all cases. Ensemble simulations also furnish information on the statistical distributions of the free energy calculations which exhibit non-normal behavior. We find that the “enhanced sampling” method known as replica exchange with solute tempering degrades RBFE predictions. We also report definitively on numerous associated alchemical factors including the choice of ligand charge method, flexibility in ligand structure, and the size of the alchemical region including the number of atoms involved in transforming one ligand into another. Our findings provide a key set of recommendations that should be adopted for the reliable application of RBFE methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterisation of [11C]PR04.MZ in Papio anubis baboon: A selective high-affinity radioligand for quantitative imaging of the dopamine transporter

N-(4-fluorobut-2-yn-1-yl)-2{beta}-carbomethoxy-3{beta}-(4{prime}-tolyl)nortropane (PR04.MZ, 1) is a PET radioligand for the non-invasive exploration of the function of the cerebral dopamine transporter (DAT). A reliable automated process for routine production of the carbon-11 labelled analogue [{sup 11}C]PR04.MZ ([{sup 11}C]-1) has been developed using GMP compliant equipment. An adult female Papioanubis baboon was studied using a test-retest protocol with [{sup 11}C]-1 in order to assess test-retest reliability, metabolism and CNS distribution profile of the tracer in non-human primates. Blood sampling was performed throughout the studies for determination of the free fraction in plasma (fP), plasma input functions and metabolic degradation of the radiotracer [{sup 11}C]-1. Time-activity curves were derived for the putamen, the caudate nucleus, the ventral striatum, the midbrain and the cerebellum. Distribution volumes (VT) and non-displaceable binding potentials (BPND) for various brain regions and the blood were obtained from kinetic modelling. [{sup 11}C]-1 shows promising results as aselective marker of the presynaptic dopamine transporter. With the reliable visualisation of the extra-striatal dopaminergic neurons and no indication on labelled metabolites, the tracer provides excellent potential for translation into man.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Investigating parameter trainability in the SNAP-displacement protocol of a qudit system

Here, in this study, we explore the universality of Selective Number-dependent Arbitrary Phase (SNAP) and Displacement gates for quantum control in qudit-based systems. However, optimizing the parameters of these gates poses a challenging task. Our main focus is to investigate the sensitivity of training any of the SNAP parameters in the SNAP-Displacement protocol. We analyze conditions that could potentially lead to the Barren Plateau problem in a qudit system and draw comparisons with multi-qubit systems. The parameterized ansatz we consider consists of blocks, where each block is composed of hardware operations, namely SNAP and Displacement gates [Fösel et al 2020 Efficient cavity control with snap gates arXiv:2004.14256]. Applying Variational Quantum algorithm (VQA) with observable and gate cost functions, we utilize techniques similar to those in [McClean et al 2018 Barren plateaus in quantum neural network training landscapes Nat. Commun.9 1–6] and [Cerezo et al 2021 Cost function dependent barren plateaus in shallow parametrized quantum circuits. Nat. Commun.12 1–12] along with the concept of t − design. Through this analysis, we make the following key observations: (a) The trainability of a SNAP-parameter does not exhibit a preference for any particular direction within our cost function landscape, (b) By leveraging the first and second moments properties of Haar measures, we establish new lemmas concerning the expectation of certain polynomial functions, and (c) utilizing these new lemmas, we identify a general condition that indicates an expected trainability advantage in a qudit system when compared to multi-qubit systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accelerated Snowmelt Protocol to Simulate Climate Change Induced Impacts on Snowpack Dependent Ecosystems

Field studies that simulate the effects of climate change are important for a predictive understanding of ecosystem responses to a changing environment. Among many concerns, regional warming can result in advanced timing of spring snowmelt in snowpack dependent ecosystems, which could lead to longer snow-free periods and drier summer soils. Past studies investigating these impacts of climate change have manipulated snowmelt with a variety of techniques that include manual snowpack alteration with a shovel, infrared radiation, black sand and fabric covers. Within these studies however, sufficient documentation of methods is limited, which can make experimental reproduction difficult. Here, we outline a detailed plot-scale protocol that utilizes a permeable black geotextile fabric deployed on top of an isothermal spring snowpack to induce advanced snowmelt. The method offers a reliable and cost-effective approach to induce snowmelt by passively increasing solar radiation absorption at the snow surface. In addition, control configurations with no snowpack manipulation are paired adjacent to the induced snowmelt plot for experimental comparison. Past and ongoing deployments in Colorado subalpine ecosystems indicate that this approach can accelerate snowmelt by 14-23 days, effectively mimicking snowmelt timing at lower elevations. This protocol can be applied to a variety of studies to understand the hydrological, ecological, and geochemical impacts of regional warming in snowpack dependent ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Cyber-Physical Security and Resiliency Analysis Testbed for Critical Microgrids with IEEE 2030.5: Preprint

IEEE 2030.5, also known as the Common Smart Inverter Standard (CSIP) is a protocol that specifies the interface between the end user and the smart grid. This standard was proposed recently, and provides many functions which if implemented incorrectly might lead to vulnerabilities. This paper proposes a cyber-physical microgrid testbed using OpenDSS and IEEE 2030.5 that can be used to study the performance of the CSIP protocol various scenarios. For critical microgrid installations, it is essential that the critical loads are served in spite of multiple contingencies. A resiliency analysis is performed for a military microgrid to study its performance and the results are analyzed.

CVSS↗

Review of Soil Organic Carbon Measurement Protocols: A US and Brazil Comparison and Recommendation

Soil organic carbon (SOC) change influences the life-cycle assessment (LCA) calculations for globally traded bio-based products. Broad agreement on the importance of SOC measurement stands in contrast with inconsistent measurement methods. This paper focuses on published SOC research on lands managed for maize ( Zea mays L.) in the U.S. and sugarcane ( Saccharum officinarum L.) in Brazil. A literature review found that reported SOC measurement protocols reflect different sampling strategies, measurement techniques, and laboratory analysis methods. Variability in sampling techniques (pits versus core samples), depths, increments for analysis, and analytical procedures (wet oxidation versus dry combustion) can influence reported SOC values. To improve consistency and comparability in future SOC studies, the authors recommend that: (a) the methods applied for each step in SOC studies be documented; (b) a defined protocol for soil pits or coring be applied; (c) samples be analyzed at 10 cm intervals for the full rooting depth and at 20 cm intervals below rooting until reaching 100 cm; (d) stratified sampling schemes be applied where possible to reflect variability across study sites; (e) standard laboratory techniques be used to differentiate among labile and stable SOC fractions; and (f) more long-term, diachronic approaches be used to assess SOC change. Here, we conclude with suggestions for future research to further improve the comparability of SOC measurements across sites and nations.

54 ENVIRONMENTAL SCIENCES↗

A Large-Scale Analysis to Optimize the Control and V2V Communication Protocols for CDA Agreement-Seeking Cooperation

Cooperative driving automation (CDA) Class C, agreement-seeking cooperation, is an innovative and practical solution that can promote cooperation among general passenger vehicles on the road. However, more comprehensive studies are needed before establishing the standard protocols of agreement-seeking cooperation, such as communication frequency and the duration of cooperation. Here, this article presents an initiative study on the impacts of communication capabilities on agreement-seeking cooperation. Through a large-scale analysis by regulating vehicle-to-vehicle (V2V) communication metrics, this work suggests desirable system parameters that can maximize the benefits of cooperation and ensure reliable operability while avoiding exhaustive communication loads. As the first step, an example agreement-seeking cooperation system is created for a car-following scenario, including decision-making and control algorithms for autonomous vehicles. Then, software-in-the-loop tests explore the performance of the developed system as it encounters various communication risks, such as latency and message packet drops. The system performance metrics are evaluated from various angles, including the time consumed for the agreement-seeking process, cooperation ratio, and the ratio of faulty cooperation. Energy saving from the cooperation is assessed by using simulation software that can run multiple high-fidelity vehicle models simultaneously. Based on the analyses, this article suggests the V2V communication requirements for the reliable operation of CDA agreement-seeking, which can be referred to when developing the standard protocols of agreement-seeking cooperation.

42 ENGINEERING↗

Predicting ground level impacts of solid rocket motor testing

Beginning in August of 1988 and continuing until the present, NASA at Stennis Space Center, Mississippi has conducted environmental monitoring of selected static test firings of the solid rocket motor used on the Space Shuttle. The purpose of the study was to assess the modeling protocol adapted for use in predicting plume behavior for the Advanced Solid Rocket Motor that is to be tested in Mississippi beginning in the mid-1990's. Both motors use an aluminum/ammonium perchlorate fuel that produces HCl and Al2O3 particulates as the major combustion products of concern. A combination of COMBUS.sr and PRISE.sr subroutines and the INPUFF model are used to predict the centerline stabilization height, the maximum concentration of HCl and Al2O3 at ground level, and distance to maximum concentration. Ground studies were conducted to evaluate the ability of the model to make these predictions. The modeling protocol was found to be conservative in the prediction of plume stabilization height and in the concentrations of the two emission products predicted.

Douglas, Willard L.↗

The Green's Function Model Intercomparison Project (GFMIP) Protocol

The atmospheric Green's function method is a technique for modeling the response of the atmosphere to changes in the spatial field of surface temperature. While early studies applied this method to changes in atmospheric circulation, it has also become an important tool to understand changes in radiative feedbacks due to evolving patterns of warming, a phenomenon called the “pattern effect.” To better study this method, this paper presents a protocol for creating atmospheric Green's functions to serve as the basis for a model intercomparison project, GFMIP. The protocol has been developed using a series of sensitivity tests performed with the HadAM3 atmosphere-only general circulation model, along with existing and new simulations from other models. Our preliminary results have uncovered nonlinearities in the response of the atmosphere to surface temperature changes, including an asymmetrical response to warming versus cooling patch perturbations, and a change in the dependence of the response on the magnitude and size of the patches. These nonlinearities suggest that the pattern effect may depend on the heterogeneity of warming as well as its location. These experiments have also revealed tradeoffs in experimental design between patch size, perturbation strength, and the length of control and patch simulations. The protocol chosen on the basis of these experiments balances scientific utility with the simulation time and setup required by the Green's function approach. Running these simulations will further our understanding of many aspects of atmospheric response, from the pattern effect and radiative feedbacks to changes in circulation, cloudiness, and precipitation.

54 ENVIRONMENTAL SCIENCES↗

Effect of Metallic Li on the Behavior of Metals in Molten Salts

The deleterious effect of Li0 on the reactor container materials has not been studied. Exposure to liquid Li 0 results in material degradation primarily through lithium intercalation, leaching of specific alloying elements, and decarburization. The objective of this research is to understand how the presence of Li 0 in molten LiCl-Li 2 O affects the degradation of two classes of alloys by correlating their accelerated and long term electrochemical behavior to the surface chemistry of the alloys and the chemistry of the electrolyte. This study has completed all the proposed tasks. The project led to the design and development of unique experimental setups and protocols. Several groundbreaking findings resulted from this study. The project had several products in terms of student education, thesis and dissertation, publications and presentations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mammographic compression after breast conserving therapy: Controlling pressure instead of force

Purpose: X-ray mammography is the primary tool for early detection of breast cancer and for follow-up after breast conserving therapy (BCT). BCT-treated breasts are smaller, less elastic, and more sensitive to pain. Instead of the current force-controlled approach of applying the same force to each breast, pressure-controlled protocols aim to improve standardization in terms of physiology by taking breast contact area and inelasticity into account. The purpose of this study is to estimate the potential for pressure protocols to reduce discomfort and pain, particularly the number of severe pain complaints for BCT-treated breasts. Methods: A prospective observational study including 58 women having one BCT-treated breast and one untreated nonsymptomatic breast, following our hospital's 18 decanewton (daN) compression protocol was performed. Breast thickness, applied force, contact area, mean pressure, breast volume, and inelasticity (mean E-modulus) were statistically compared between the within-women breast pairs, and data were used as predictors for severe pain, i.e., scores 7 and higher on an 11-point Numerical Rating Scale. Curve-fitting models were used to estimate how pressure-controlled protocols affect breast thickness, compression force, and pain experience. Results: BCT-treated breasts had on average 27% smaller contact areas, 30% lower elasticity, and 30% higher pain scores than untreated breasts (allp < 0.001). Contact area was the strongest predictor for severe pain (p < 0.01). Since BCT-treatment is associated with an average 0.36 dm{sup 2} decrease in contact area, as well as increased pain sensitivity, BCT-breasts had on average 5.3 times higher odds for severe pain than untreated breasts. Model estimations for a pressure-controlled protocol with a 10 kPa target pressure, which is below normal arterial pressure, suggest an average 26% (range 10%–36%) reduction in pain score, and an average 77% (range 46%–95%) reduction of the odds for severe pain. The estimated increase in thickness is +6.4% for BCT breasts. Conclusions: After BCT, women have hardly any choice in avoiding an annual follow-up mammogram. Model estimations show that a 10 kPa pressure-controlled protocol has the potential to reduce pain and severe pain particularly for these women. The results highly motivate conducting further research in larger subject groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing radiation dose to the female breast during CT coronary angiography: A simulation study comparing breast shielding, angular tube current modulation, reduced kV, and partial angle protocols using an unknown-location signal-detectability metric

Purpose: The authors compared the performance of five protocols intended to reduce dose to the breast during computed tomography (CT) coronary angiography scans using a model observer unknown-location signal-detectability metric.Methods: The authors simulated CT images of an anthropomorphic female thorax phantom for a 120 kV reference protocol and five “dose reduction” protocols intended to reduce dose to the breast: 120 kV partial angle (posteriorly centered), 120 kV tube-current modulated (TCM), 120 kV with shielded breasts, 80 kV, and 80 kV partial angle (posteriorly centered). Two image quality tasks were investigated: the detection and localization of 4-mm, 3.25 mg/ml and 1-mm, 6.0 mg/ml iodine contrast signals randomly located in the heart region. For each protocol, the authors plotted the signal detectability, as quantified by the area under the exponentially transformed free response characteristic curve estimator (A-caret{sub FE}), as well as noise and contrast-to-noise ratio (CNR) versus breast and lung dose. In addition, the authors quantified each protocol's dose performance as the percent difference in dose relative to the reference protocol achieved while maintaining equivalent A-caret{sub FE}.Results: For the 4-mm signal-size task, the 80 kV full scan and 80 kV partial angle protocols decreased dose to the breast (80.5% and 85.3%, respectively) and lung (80.5% and 76.7%, respectively) with A-caret{sub FE} = 0.96, but also resulted in an approximate three-fold increase in image noise. The 120 kV partial protocol reduced dose to the breast (17.6%) at the expense of increased lung dose (25.3%). The TCM algorithm decreased dose to the breast (6.0%) and lung (10.4%). Breast shielding increased breast dose (67.8%) and lung dose (103.4%). The 80 kV and 80 kV partial protocols demonstrated greater dose reductions for the 4-mm task than for the 1-mm task, and the shielded protocol showed a larger increase in dose for the 4-mm task than for the 1-mm task. In general, the CNR curves indicate a similar relative ranking of protocol performance as the corresponding A-caret{sub FE} curves, however, the CNR metric overestimated the performance of the shielded protocol for both tasks, leading to corresponding underestimates in the relative dose increases compared to those obtained when using the A-caret{sub FE} metric.Conclusions: The 80 kV and 80 kV partial angle protocols demonstrated the greatest reduction to breast and lung dose, however, the subsequent increase in image noise may be deemed clinically unacceptable. Tube output for these protocols can be adjusted to achieve a more desirable noise level with lesser breast dose savings. Breast shielding increased breast and lung dose when maintaining equivalent A-caret{sub FE}. The results demonstrated that comparisons of dose performance depend on both the image quality metric and the specific task, and that CNR may not be a reliable metric of signal detectability.

61 RADIATION PROTECTION AND DOSIMETRY↗

NASA's Ground Test Unit (GTU) Lunar Terrain Vehicle (LTV) Conceptual Hand Controllers Studies

Over that past year, the National Aeronautics and Space Administration (NASA) has been preparing and developing a set of standardized testing protocols for the commercial LTV vendor selection. Two studies have been conducted on two possible hand controller concepts specifically designed for the operation of NASA’s Ground Test Unit (GTU) Lunar Terrain Vehicle (LTV) that can be applied to the heretofore unknown designs developed by future LTV vendors. The objective for the two studies were to determine which hand controller enable acceptable operation of the LTV in a simulated lunar traverse. In the first evaluation a total of nine subjects in shirtsleeves with ungloved hands performed two simulated lunar driving courses in an engineering simulator with each hand controller. Controller concept one was the T-handle fashioned after the Apollo Lunar Roving Vehicle’s (LRV) T-Handle controller. The rational for using this design is it’s a proven design while in a pressurized suit. However, the LTV does have a driving mode the LRV did not consider. The mode of crabbing or strafing the vehicle at different angles; thus, the idea of a dual T-Handle controllers to accommodate this function without using a switch or display was introduced. The second concept controller is a new innovative controller call the Tri-Rotor [NASA patent review MSC-27385-1]. Inspired by Formula One race steering, the Tri-Rotor was designed to take advantage of the restricted movement and dexterity of a pressurized space suit. During testing, all subjects were able to successfully navigate through two test courses of varying lengths and complexity. Results indicated the dual Thandle had minimal recommendations for improvement while the Tri-Rotor had more extensive ones. It must be noted, the Tri-Rotor is a first-generation prototype and has some known mechanical concerns; thus, recommendations from this study will be incorporated into the second generation.

Human Factors↗

Optimized Negative Staining: a High-throughput Protocol for Examining Small and Asymmetric Protein Structure by Electron Microscopy

Structural determination of proteins is rather challenging for proteins with molecular masses between 40 - 200 kDa. Considering that more than half of natural proteins have a molecular mass between 40 - 200 kDa, a robust and high-throughput method with a nanometer resolution capability is needed. Negative staining (NS) electron microscopy (EM) is an easy, rapid, and qualitative approach which has frequently been used in research laboratories to examine protein structure and protein-protein interactions. Unfortunately, conventional NS protocols often generate structural artifacts on proteins, especially with lipoproteins that usually form presenting rouleaux artifacts. By using images of lipoproteins from cryo-electron microscopy (cryo-EM) as a standard, the key parameters in NS specimen preparation conditions were recently screened and reported as the optimized NS protocol (OpNS), a modified conventional NS protocol. Artifacts like rouleaux can be greatly limited by OpNS, additionally providing high contrast along with reasonably high-resolution (near 1 nm) images of small and asymmetric proteins. These high-resolution and high contrast images are even favorable for an individual protein (a single object, no average) 3D reconstruction, such as a 160 kDa antibody, through the method of electron tomography. Moreover, OpNS can be a high-throughput tool to examine hundreds of samples of small proteins. For example, the previously published mechanism of 53 kDa cholesteryl ester transfer protein (CETP) involved the screening and imaging of hundreds of samples. Considering cryo-EM rarely successfully images proteins less than 200 kDa has yet to publish any study involving screening over one hundred sample conditions, it is fair to call OpNS a high-throughput method for studying small proteins. Hopefully the OpNS protocol presented here can be a useful tool to push the boundaries of EM and accelerate EM studies into small protein structure, dynamics and mechanisms.

47 OTHER INSTRUMENTATION↗

Artificial Gravity as a Multi-System Countermeasure to Bed Rest Deconditioning: Pilot Study Overview

Efficient, effective, multi-system countermeasures will likely be required to protect the health, safety, and performance of crews aboard planned exploration-class space flight missions to Mars and beyond. To that end, NASA, DLR, and IMBP initiated a multi-center international project to begin systematically exploring the utility of artificial gravity (AG) as a multi-system countermeasure in ground based venues using test subjects deconditioned by bed rest. The goal of this project is to explore the efficacy of short-radius, intermittent AG as a countermeasure to bone, muscle, cardiovascular, and sensory-motor adaptations to hypogravity. This session reports the results from a pilot study commissioned to validate a standardized protocol to be used by all centers involved in the project. Subject selection criteria, medical monitoring requirements, medical care procedures, experiment control procedures, and standardized dependent measures were established jointly. Testing was performed on 15 rigorously screened male volunteers subjected to 21 days of 6deg HDT bed rest. (All provided written consent to volunteer after the nature of the study and its hazards were clearly explained to them.) Eight were treated with daily 1hr AG exposures (2.5g at the feet decreasing to 1.0g at the heart) aboard a short radius (3m) centrifuge, while the other seven served as controls. Multiple tests of multiple dependent measures were made in each of the primary physiological systems of interest during a 10 day acclimatization period prior to HDT bed rest and again during an 8 day recovery period after the bed rest period was complete. Analyses of these data (presented in other papers in this session) suggest the AG prescription had salutary effects on aspects of the bone, muscle, and cardiovascular systems, with no untoward effects on the vestibular system, the immune system, or cognitive function. Furthermore, treatment subjects were able to tolerate 153/160 centrifuge sessions over the 21 day deconditioning protocol, suggesting that tolerance was unaffected by deconditioning. These positive results set the stage for full implementation of the planned multi-center international AG project. Future work will be devoted to developing optimization techniques for AG prescriptions (likely supplemented by exercise) to provide maximum physiological protection across all systems subject to space flight deconditioning in both men and women with minimum time and/or side effects. While a continuous AG solution (rotating vehicle) would likely be more efficient, this study suggests that intermittent AG could be an effective multi-system countermeasure.

Paloski, William H.↗

A communal catalogue reveals Earth’s multiscale microbial diversity

Our growing awareness of the importance and diversity of the microbial world contrasts starkly with our limited understanding of its fundamental structure. Despite remarkable advances in DNA sequence generation, a lack of standardized protocols and common analytical framework impede useful comparison between studies, hindering development of global inferences about microbial life on Earth. Here, we show that with coordinated protocols, exact microbial 16S rRNA gene sequences can be followed across scores of individual studies, revealing patterns of diversity, community structure, and life history strategy at a planetary scale. Using 27,751 crowdsourced environmental samples comprising more than 2.2 billion reads, we find sharp divides between host-associated and free-living communities. We show that the distribution of taxonomic and sequence diversity follows consistent trends across samples types and along gradients of environmental parameters, highlighting some of the global evolutionary patterns and ecological principles that underpin Earth’s microbiome. Here, this dataset provides the most complete environmental survey of our microbial world to date, and serves as a growing reference to provide immediate global context to future microbial surveys.

54 ENVIRONMENTAL SCIENCES↗

Accuracy of a dose-area product compared to an absorbed dose to water at a point in a 2 cm diameter field

Purpose: Graphite calorimeters with a core diameter larger than the beam can be used to establish dosimetric references in small fields. The dose-area product (DAP) measured can theoretically be linked to an absorbed dose at a point by the determination of a profile correction. This study aims at comparing the DAP-based protocol to the usual absorbed dose at a point protocol in a 2 cm diameter field for which both references exist. Methods: Two calorimeters were used, respectively, with a sensitive volume of 0.6 cm (for the absorbed dose at a point measurement) and 3 cm diameter (for the DAP measurement). Profile correction was calculated from a 2D dose mapping using three detectors: a PinPoint chamber, a synthetic diamond, and EBT3 films. A specific protocol to read EBT3 films was implemented and the dose-rate and energy dependences were studied to assure a precise measurement, especially in the penumbra and out-of-field regions. Results: EBT3 films were found independent on dose rates over the range studied but showed a strong under-response (18%) at low energies. Depending on the dosimeter used for calculating the profile correction, a deviation of 0.8% (PinPoint chamber), 0.9% (diamond), or 1.9% (EBT3 films) was observed between the calibration coefficient derived from DAP measurements and the one directly established in terms of absorbed dose to water at a point. Conclusions: The DAP method can currently be linked to the classical dosimetric reference system based in an absorbed dose at a point only with a confidence interval of 95% (k = 2). None of the detectors studied can be used to determine an absorbed dose to water at a point from a DAP measurement with an uncertainty smaller than 1.2%.

60 APPLIED LIFE SCIENCES↗