Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchronized sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

NASA Tech Briefs, August 2008

Customizable Digital Receivers for Radar Two-Camera Acquisition and Tracking of a Flying Target Visual Data Analysis for Satellites A Data Type for Efficient Representation of Other Data Types Hand-Held Ultrasonic Instrument for Reading Matrix Symbols Broadband Microstrip-to-Coplanar Strip Double-Y Balun A Topographical Lidar System for Terrain-Relative Navigation Programmable Low-Voltage Circuit Breaker and Tester Electronic Switch Arrays for Managing Microbattery Arrays Topics covered include: Lower-Dark-Current, Higher-Blue-Response CMOS Imagers; Fabricating Large-Area Sheets of Single-Layer Graphene by CVD; Support for Diagnosis of Custom Computer Hardware; Providing Goal-Based Autonomy for Commanding a Spacecraft; Dynamic Method for Identifying Collected Sample Mass; Optimal Planning and Problem-Solving; Attitude-Control Algorithm for Minimizing Maneuver Execution Errors; Grants Document-Generation System; Heat-Storage Modules Containing LiNO3 3H2O and Graphite Foam; Precipitation-Strengthened, High-Temperature, High-Force Shape Memory Alloys; Improved Relief Valve Would Be Less Susceptible to Failure; Safety Modification of Cam-and-Groove Hose Coupling; Using Composite Materials in a Cryogenic Pump; Using Electronic Noses to Detect Tumors During Neurosurgery; Producing Newborn Synchronous Mammalian Cells; Smaller, Lower-Power Fast-Neutron Scintillation Detectors; Rotationally Vibrating Electric-Field Mill; Estimating Hardness from the USDC Tool-Bit Temperature Rise; Particle-Charge Spectrometer; Automated Production of Movies on a Cluster of Computers; FIDO-Class Development Rover; and Tone-Based Command of Deep Space Probes Using Ground Antennas.

Source record↗

The performance of magnetic lens for focusing VCN-SANS.

We have developed a prototype rotating-permanent magnet sextupole lens (named rot-PMSx) for more efficient experiments with neutron beams in time of flight (ToF) mode. This lens can modulate the focusing strength over range 1.5 x 10{sup 4} T/m{sup 2} {le} g' {le} 5.9 x 10{sup 4} T/m{sup 2}. Synchronization between the modulation and the beam pulse produces a focused beam without significant chromatic aberration. We anticipate that this lens could be utilized in focusing small angle neutron scattering (SANS) instruments for novel approach to high resolution SANS. We carried out experiments testing the principle of this lens at the very cold neutron (VCN) beamline (PF2) at Institut Laue-Langevin (ILL), France. The focused beam image size at the detector was kept constant at the same beam size as the source ({approx} 3 mm) over a wavelength range of 30 {angstrom} {le} {lambda} {le} 48 {angstrom} in focal length of {approx} 1.14 m. The flux gain was about 12 relative to a beam without focusing, and the depth of focus was quite large. These results show the good performance of this lens and the system. Thereupon we have demonstrated the performance of this test bed for high resolution focusing of VCN-SANS for a well-studied softmatter sample; a deuterium oxide solution of Pluronic F127, an (PEO){sub 100}(PPO){sub 65}(PEO){sub 100} tri-block copolymer in deuterium oxide. The results of the focusing experiment and the focusing VCN-SANS are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Designing a parallel Feel-the-Way clustering algorithm on HPC systems

This paper introduces a new parallel clustering algorithm, named Feel-the-Way clustering algorithm, that provides better or equivalent convergence rate than the traditional clustering methods by optimizing the synchronization and communication costs. Our algorithm design centers on how to optimize three factors simultaneously: reduced synchronizations, improved convergence rate, and retained same or comparable optimization cost. To compare the optimization cost, we use the Sum of Square Error (SSE) cost as the metric, which is the sum of the square distance between each data point and its assigned clusters. Compared with the traditional MPI k-means algorithm, the new Feel-the-Way algorithm requires less communications among participating processes. As for the convergence rate, the new algorithm requires fewer number of iterations to converge. As for the optimization cost, it obtains the SSE costs that are close to the k-means algorithm. In the paper, we first design the full-step Feel-the-Way k-means clustering algorithm that can significantly reduce the number of iterations that are required by the original k-means clustering method. Next, we improve the performance of the full-step algorithm by adopting an optimized sampling-based approach, named reassignment-history-aware sampling. Our experimental results show that the optimized sampling-based Feel-the-Way method is significantly faster than the widely used k-means clustering method, and can provide comparable optimization costs. More extensive experiments with several synthetic datasets and real-world datasets (e.g., MNIST, CIFAR-10, ENRON, and PLACES-2) show that the new parallel algorithm can outperform the open source MPI k-means library by up to 110% on a high-performance computing system using 4,096 CPU cores. In addition, the new algorithm can take up to 51% fewer iterations to converge than the k-means clustering algorithm.

97 MATHEMATICS AND COMPUTING↗

Development of a fast framing detector for electron microscopy

A high frame rate detector system is described that enables fast real-time data analysis of scanning diffraction experiments in scanning transmission electron microscopy (STEM). This is an end-to-end development that encompasses the data producing detector, data transportation, and real-time processing of data. The detector will consist of a central pixel sensor that is surrounded by annular silicon diodes. Both components of the detector system will synchronously capture data at almost 100 kHz frame rate, which produces an approximately 400 Gb/s data stream. Low-level preprocessing will be implemented in firmware before the data is streamed from the National Center for Electron Microscopy (NCEM) to the National Energy Research Scientific Computing Center (NERSC). Live data processing, before it lands on disk, will happen on the Cori supercomputer and aims to present scientists with prompt experimental feedback. This online analysis will provide rough information of the sample that can be utilized for sample alignment, sample monitoring and verification that the experiment is set up correctly. Only a compressed version of the relevant data is then selected for more in-depth processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Omega flight-test data reduction sequence

Computer programs for Omega data conversion, summary, and preparation for distribution are presented. Program logic and sample data formats are included, along with operational instructions for each program. Flight data (or data collected in flight format in the laboratory) is provided by the Ohio University Omega receiver base in the form of 6-bit binary words representing the phase of an Omega station with respect to the receiver's local clock. All eight Omega stations are measured in each 10-second Omega time frame. In addition, an event-marker bit and a time-slot D synchronizing bit are recorded. Program FDCON is used to remove data from the flight recorder tape and place it on data-processing cards for later use. Program FDSUM provides for computer plotting of selected LOP's, for single-station phase plots, and for printout of basic signal statistics for each Omega channel. Mean phase and standard deviation are printed, along with data from which a phase distribution can be plotted for each Omega station. Program DACOP simply copies the Omega data deck a controlled number of times, for distribution to users.

Lilley, R. W.↗

Membrane Vibration Analysis Above the Nyquist Limit with Fluorescence Videogrammetry

A new method for generating photogrammetric targets by projecting an array of laser beams onto a membrane doped with fluorescent laser dye has recently been developed. In this paper we review this new fluorescence based technique, then proceed to show how it can be used for dynamic measurements, and how a short pulsed (10 ns) laser allows the measurement of vibration modes at frequencies several times the sampling frequency. In addition, we present experimental results showing the determination of fundamental and harmonic vibration modes of a drum style dye-doped polymer membrane tautly mounted on a 12-inch circular hoop and excited with 30 Hz and 62 Hz sinusoidal acoustic waves. The projected laser dot pattern was generated by passing the beam from a pulsed Nd:YAG laser though a diffractive optical element, and the resulting fluorescence was imaged with three digital video cameras, all of which were synchronized with a pulse and delay generator. Although the video cameras are capable of 240 Hz frame rates, the laser s output was limited to 30 Hz and below. Consequently, aliasing techniques were used to allow the measurement of vibration modes up to 186 Hz with a Nyquist limit of less than 15 Hz.

Dorrington, Adrian A.↗

Nadir Measurements of Carbon Monoxide Distributions by the Tropospheric Emission Spectrometer Instrument Onboard the Aura Spacecraft: Overview of Analysis Approach and Examples of Initial Results

We provide an overview of the nadir measurements of carbon monoxide (CO) obtained thus far by the Tropospheric Emission Spectrometer (TES). The instrument is a high resolution array Fourier transform spectrometer designed to measure infrared spectral radiances from low Earth orbit. It is one of four instruments successfully launched onboard the Aura platform into a sun synchronous orbit at an altitude of 705 km on July 15, 2004 from Vandenberg Air Force Base, California. Nadir spectra are recorded at 0.06/cm spectral resolution with a nadir footprint of 5 x 8 km. We describe the TES retrieval approach for the analysis of the nadir measurements, report averaging kernels for typical tropical and polar ocean locations, characterize random and systematic errors for those locations, and describe instrument performance changes in the CO spectral region as a function of time. Sample maps of retrieved CO for the middle and upper troposphere from global surveys during December 2005 and April 2006 highlight the potential of the results for measurement and tracking of global pollution and determining air quality from space.

carbon monoxide↗

Ultra-Low Noise Laser and Optical Frequency Comb-Based Timing System for the Event Horizon Explorer (EHE) Mission

Very Long Baseline Interferometry (VLBI) requires a highly stable time reference and synchronization system to maintain coherence between observations recorded independently at multiple stations – for example, the array of ground-based radio telescopes that comprise the Event Horizon Telescope (EHT). Instability in the time reference or inaccuracy in the synchronization impacts phase conference and reduces the performance of the VLBI system. For space-based telescopes like the Event Horizon Explorer (EHE) mission, the precision timing system must meet the size, weight, and power (SWaP) constraints of the spacecraft platform and be capable of operating in the space environment. The EHE mission is a proposed extension to the EHT that can improve the angular and time resolution of observations by enabling longer interferometric baselines than are possible on the Earth and sampling a wide range of Fourier spatial frequencies throughout the orbital motion. In this effort, we demonstrate the performance of one option for the EHE mission: the use of a space-qualified, ultra-low noise laser developed as part of the Laser Interferometer Space Antenna (LISA) mission as the timing reference, and an optical frequency comb to transfer the stability of this laser to the microwave regime for instrumentation use. We describe the implementation of the microwave down-conversion, in which the LISA cavity-stabilized laser is locked to a self-referenced optical frequency comb to divide the optical frequency down to 100 MHz. The phase noise of the 100 MHz signal is measured and validated using a phase noise analyzer that is referenced to a separate laboratory ultra-stable laser system. We present the results of this experiment, which demonstrates that the performance of this system meets the EHE requirement: a relative frequency error of 1e-14 from 1 to 30 seconds.

Hannah Tomio↗

Tunable electron beam pulser for picoseconds stroboscopic microscopy in transmission electron microscopes

For two decades, time-resolved transmission electron microscopes (TEM) have relied on pulsed-laser photoemission to generate electron bunches to explore sub-microsecond to sub-picosecond dynamics. Despite the vast successes of photoemission time-resolved TEMs, laser-based systems are inherently complex, thus tend not to be turn-key. In this paper, we report on the successful retrofit of a commercial 200 keV TEM, without an external laser, capable of producing continuously tunable pulsed electron beams with repetition rates from 0.1 GHz up to 12 GHz and a tunable bunch length from tens of nanoseconds down to 10 ps. This innovation enables temporal access into previously inaccessible regimes: i.e., high repetition rate stroboscopic experiments. Combination of a pair of RF-driven traveling wave stripline elements, quadrupole magnets, and a variable beam aperture enables operation of the instrument in (1) continuous waveform (CW) mode as though the instrument was never modified (i.e. convention TEM operation mode, where the electrons from the emission cathode randomly arrive at the sample without resolvable time information), (2) stroboscopic (pump-probe) mode, and (3) pulsed beam mode for dose rate sensitive materials. In order to analyze the effect of a pulsed beam on image quality, we examined Au nanoparticles using bright field, high-resolution TEM imaging and selected area diffraction in both continuous and pulsed-beam mode. Furthermore, in comparison of conventional TEMs, the add-on beam pulser enables the observation of ultrafast dynamic behavior in materials that are reversible under synchronized excitation.

36 MATERIALS SCIENCE↗

Seeking Augmented Information Content Concerning Diurnal Precipitation Achieved by Combining TRMM-PR and CloudSat-CPR Radar Data Sets

The CloudSat satellite's Cloud Profiling Radar (CPR) is a highly sensitive 94 GHz (W-band) nadir viewing radar system flown in retrograde sun synchronous orbit useful for determining the vertical structure of cloud hydrometeors down to sensitivity of approx. -30 dBZ reflectivity factor. Given this sensitivity, it is possible to unambiguously measure precipitation rates in clouds over a spectrum extending from approx. 0.08 - 3.0 mm hr (sup -1) down to altitudes of 0.5 km with approx.0.25 km vertical binning. This enables an effective means to measure a great deal of the drizzle and light rain spectrum. However, because of its near-polar sunsynchronous orbit, CloudSat cannot sample the diurnal cycle of precipitation, nor with its nadir-only CPR view can it obtain a high duty cycle in sampling precipitation at fixed local times over fixed positions. On the other hand, the TRMM satellite, which is flown in a non-sunsynchronous 35-degree inclined orbit carrying the 13.8 GHz KU-band Precipitation Radar (PR) scanning through nadir over an approx. 225 km swath, can sample both the diurnal cycle and with a much improved duty cycle relative to CloudSat. Moreover, the PR and CPR have the same 0.25 km vertical binning capability. The PR's greatest shortcoming is its approx. +17 dBZ sensitivity, which eliminates the possibility of measuring rain rates below -0.3-0.5 mm hr(sup -1), which can involve rainfall accumulations of up to 50% of the total over some regions. This begs the question of whether by combining CPR and PR data sets, whether it is possible to obtain an augmented measurement of the diurnal precipitation cycle. By collecting complimentary datasets during CloudSat and TRMM satellite orbit crossings within a delta t = 45-min proximity window, it is possible to demonstrate that whenever TRMM detects a precipitation signal, the correlations along the vertical axis between the reflectivities acquired from the CPR and PR are in inverse proportion to the magnitude of the delta t proximity window. By taking advantage of these underlying correlations, it is possible to develop a functional which can be used to broaden the reflectivity spectrum, concomitantly the rain rate spectrum, of the PR measurements based on the inherently broader reflectivity spectrum of the CPR at the lower reflectivity end of the spectrum, concomitantly at lighter rain rates. With the functional in place, it is then possible to produce synthetic CloudSat precipitation imagery over the PR track and thus over the diurnal time period. These augmented data are then used to study the spectral-vertical diurnal properties of precipitation over oceanic regions observed by TRMM.

Smith, Eric A.↗

High-Speed, Multi-Channel Serial ADC LVDS Interface for Xilinx Virtex-5 FPGA

Analog-to-digital converters (ADCs) are used in scientific and communications instruments on all spacecraft. As data rates get higher, and as the transition is made from parallel ADC designs to high-speed, serial, low-voltage differential signaling (LVDS) designs, the need will arise to interface these in field programmable gate arrays (FPGAs). As Xilinx has released the radiation-hardened version of the Virtex-5, this will likely be used in future missions. High-speed serial ADCs send data at very high rates. A de-serializer instantiated in the fabric of the FPGA could not keep up with these high data rates. The Virtex-5 contains primitives designed specifically for high-speed, source-synchronous de-serialization, but as supported by Xilinx, can only support bitwidths of 10. Supporting bit-widths of 12 or more requires the use of the primitives in an undocumented configuration, a non-trivial task. A new SystemVerilog design was written that is simpler and uses fewer hardware resources than the reference design described in Xilinx Application Note XAPP866. It has been shown to work in a Xilinx XC5VSX24OT connected to a MAXIM MAX1438 12-bit ADC using a 50-MHz sample clock. The design can be replicated in the FPGA for multiple ADCs (four instantiations were used for a total of 28 channels).

Taylor, Gregory H.↗

Effective sampling-driven performance tools for GPU-accelerated supercomputers, In: SC '13 Proceedings of the International Conference on High Performance Computing, Networking, Storage and Analysis

Performance analysis of GPU-accelerated systems requires a system-wide view that considers both CPU and GPU components. In this paper, we describe how to extend system-wide, sampling-based performance analysis methods to GPU-accelerated systems. Since current GPUs do not support sampling, our implementation required careful coordination of instrumentation-based performance data collection on GPUs with sampling-based methods employed on CPUs. In addition, we also introduce a novel technique for analyzing systemic idleness in CPU/GPU systems. We demonstrate the effectiveness of our techniques with application case studies on Titan and Keeneland. Some of the highlights of our case studies are: 1) we improved performance for LULESH 1.0 by 30%, 2) we identified a hardware performance problem on Keeneland, 3) we identified a scaling problem in LAMMPS derived from CUDA initialization, and 4) we identified a performance problem that is caused by GPU synchronization operations that suffer delays due to blocking system calls.

Computer Science↗

Engineering experimental program on the effects of near-space radiation on lithium doped solar cells

The results of an experimental evaluation of the real-time degradation characteristics of lithium-diffused silicon solar cells are reported. A strontium-90 radioisotope was used for simulation of a typical earth-orbital electron environment. The experiment was performed in an ion pump vacuum chamber with samples maintained at -50, +20, +50, and +80 C. Samples were illuminated during the 6-month exposure run with solar cell 1-5 characteristics measured periodically in situ. This 6-month exposure corresponded to a 1 MeV equivalent fluence of approximately 10 to the 14th power electrons/sq cm. Several types of lithium cells were irradiatied and compared directly with conventional N/P cells. The best lithium cells compared favorably with N/P cells, particularly at the higher test temperatures. With a slight improvement of initial performance characteristics, lithium cells appear feasible for 5 to 10 year missions at synchronous altitude. Based on the reported results and those of other irradiation experiments, lithium cells would appear to be superior to N/P cells in proton-dominated earth-orbital environments. Another important conclusion of the effort was that illuminated/loaded cells degrade more rapidly than do dark/unloaded cells. The irradiation experiment provided data of high quality with a high degree of confidence because of the experimental and statistical analysis techniques utilized.

Source record↗

U–Pb Geochronology and Stable Isotope Geochemistry of Terrestrial Carbonates, Lower Cretaceous Cedar Mountain Formation, Utah: Implications for Synchronicity of Terrestrial and Marine Carbon Isotope Excursions

The terrestrial Lower Cretaceous Cedar Mountain Formation, Utah, is a critical archive of paleoclimate, tectonics, and vertebrate ecology and evolution. Early Cretaceous carbon cycle perturbations associated with ocean anoxia have been interpreted from this succession, as expressed in stable carbon isotopes. However, refining the timing of the observed stable isotope excursions remains a key challenge in understanding how marine anoxia affects the Earth system, and is ultimately recorded in the terrestrial realm. The geochronology and geochemistry of a terrestrial carbonate near the base of this succession, which potentially records the Ap7 global carbon isotope excursion, is studied here. Petrographic and geochemical analyses are used to test plausible mechanisms for U incorporation into the calcite lattice in this sample. Using these methods, the hypothesis that the incorporation of U was at or close to the timing of carbonate precipitation is evaluated. U–Pb geochronology of calcite indicates a plausible Early Cretaceous age. However, comparison of the new U–Pb ages of calcite with detrital zircon maximum depositional ages immediately beneath the studied sample indicates a disparity in the apparent sedimentation rates if both types of geochronologic information are interpreted as reflecting the timing of sediment deposition. The totality of data supports an early, and high-temperature, diagenetic timing of U incorporation, with potential for minor leaching of U in subsequent fluid–rock interaction. The most likely mechanism for U transport and immobilization in these samples is hydrothermal fluid–rock interaction. Therefore, the radiometric ages, and corresponding stable isotope composition of U-bearing carbonate domains in this sample, indicate early subsurface fluid–rock interactions and not a record of atmosphere–soil geochemical reactions.

36 MATERIALS SCIENCE↗

Clinically relevant concentrations of di (2-ethylhexyl) phthalate (DEHP) uncouple cardiac syncytium

Di(2-ethylhexyl) phthalate (DEHP) is a widely used plasticizer found in a variety of polyvinyl chloride (PVC) medical products. The results of studies in experimental animals suggest that DEHP leached from flexible PVC tubing may cause health problems in some patient populations. While the cancerogenic and reproductive effects of DEHP are well recognized, little is known about the potential adverse impact of phthalates on the heart. This study examined the effects of clinically relevant concentrations of DEHP on neonatal rat cardiomyocytes. It was found that application of DEHP to a confluent, synchronously beating cardiac cell network, leads to a marked, concentration-dependent decrease in conduction velocity and asynchronous cell beating. The mechanism behind these changes was a loss of gap junctional connexin-43, documented using Western blot analysis, dye-transfer assay and immunofluorescence. In addition to its effect on electrical coupling, DEHP treatment also affected the mechanical movement of myocyte layers. The latter was linked to the decreased stiffness of the underlying fibroblasts, as the amount of triton-insoluble vimentin was significantly decreased in DEHP-treated samples. The data indicate that DEHP, in clinically relevant concentrations, can impair the electrical and mechanical behavior of a cardiac cell network. Applicability of these findings to human patients remains to be established.

60 APPLIED LIFE SCIENCES↗

Economic consequences of improved temperature forecasts: An experiment with the Florida citrus growers (control group results)

A demonstration experiment is being planned to show that frost and freeze prediction improvements are possible utilizing timely Synchronous Meteorological Satellite temperature measurements and that this information can affect Florida citrus grower operations and decisions. An economic experiment was carried out which will monitor citrus growers' decisions, actions, costs and losses, and meteorological forecasts and actual weather events and will establish the economic benefits of improved temperature forecasts. A summary is given of the economic experiment, the results obtained to date, and the work which still remains to be done. Specifically, the experiment design is described in detail as are the developed data collection methodology and procedures, sampling plan, data reduction techniques, cost and loss models, establishment of frost severity measures, data obtained from citrus growers, National Weather Service, and Federal Crop Insurance Corp., resulting protection costs and crop losses for the control group sample, extrapolation of results of control group to the Florida citrus industry and the method for normalization of these results to a normal or average frost season so that results may be compared with anticipated similar results from test group measurements.

Source record↗

What we Hope to Learn about Global Mineral Dust Aerosols from EOS Multi-Angle Imaging SpectroRadiometer (MISR)

On global scales, just a few broad atmospheric aerosol compositional groups are commonly observed. Of these, "mineral dust" is the only group which both contains non-spherical particles, and typically has size distributions with enough large particles for particle shape to affect its visible-light-scattering properties. The MISR instrument is scheduled for launch into a 10:30 AM sun-synchronous, polar orbit aboard the EOS Terra satellite in 1999. MISR will measure the upwelling visible radiance from Earth in 4 spectral bands centered at 446, 558, 672, and 866 nm, at each of 9 emission angles spread out in the forward and aft directions along the flight path at +/-70.5 deg, +/-60.0 deg, +/-45.6 deg, +/-26.1deg, and nadir. Over a period of 7 minutes, as the spacecraft flies along, a 360 km wide swath of Earth will successively be viewed by each of the cameras, allowing MISR to sample a very large range of scattering angles; in mid latitudes, the instrument will observe scattering angles between about 60 deg and 160 deg. Global coverage will be acquired about once in 9 days at the equator; the nominal mission lifetime is 6 years. The distinction in single scattering phase function between natural distributions of spherical and randomly oriented, non-spherical particles, with a broad range of aspect ratios, shows up strongly for scattering angles ranging from about 90 deg to near 180 deg. For non-spherical particle distributions, single scattering phase functions tend to be much flatter in this region than for spherical particles. Since MISR samples the relevant range of scattering angles very well, we expect to be able to make critical distinctions between natural distributions of spherical and randomly oriented, non-spherical particles with MISR data. We anticipate that the new multiangle, multispectral data from MISR will also contain other information about particle properties, a major step beyond current spacecraft remote sensing retrievals, which obtain aerosol optical depth based on entirely assumed particle microphysical properties. According to simulations over cloud-free, calm ocean, for pure particles with natural ranges of optical depth, particle size, and indices of refraction, MISR should retrieve column optical depth for all but the darkest particles, to an uncertainty of at most 0.05 or 20%, whichever is larger, even if the particle properties are poorly known. For one common particle type, soot, constraints on the optical depth over dark ocean are very poor. The simulated measurements also should allow us to separate two to four compositional groups based on indices of refraction, and to identify three to four distinct size groups between 0.1 and 2.0 microns characteristic radius at most latitudes. The technique is most sensitive to particle microphysical properties in the "accumulation mode" sizes. where particle scattering undergoes the transition from Rayleigh to large-particle regimes for the MISR wavelengths. Based on these results, we expect to distinguish air masses containing different aerosol types, routinely and globally, with multiangle remote sensing data. Such data complements in situ and field data, which can provide details about aerosol size and composition locally that are needed to assess the radiative effects of aerosols quantitatively. Both field data and correlations in space and time with likely source and sink regions will also be helpful in developing a global picture of mineral dust aerosol budgets. Further work on the expected sensitivity of MISR to natural mixtures of pure particles, including climatologically likely mineral dust components, is currently underway.

Kahn, Ralph↗

Lightning Instrumentation System

A new comprehensive lightning instrumentation system has been designed for the Mobile Launcher 1 (ML-1) at the Kennedy Space Center, Florida. This new instrumentation system includes the synchronized recording of three B-dot, 3-axis measurement stations, one D-dot sensor and eighteen vehicle measurement channels. Each vehicle measurement channel is comprised of two currents and one voltage measurements. The instrumentation system is composed of centralized transient recorders and digitizers, connected to the transient recorders via fiber optic cables. The transient recorders are triggered by the B-dot or D-dot sensors. When the Space Launch System (SLS) vehicle is present at the ML-1, the transient recorders record data on a dual sampling rate mode, continuous slow 5 kilo-samples per second (per channel) and event driven fast 100 mega-samples per second (per channel). Without the presence of the vehicle at the ML-1, the instrumentation system operates only as an event driven fast 100 mega-samples per second (per channel). In the absence of the vehicle, the only measurements recorded are the B-dot and D-dot stations. Additionally, a portable Lightning Monitoring System (LMS) is temporarily installed inside the Orion Crew Capsule module monitoring one portable B-dot, 3-axis measurement station, and 2 Crew Capsule BUS voltages. The portable LMS has a transient recorder independent of the ML-1 transient recorders, that is triggered by the portable B-dot sensor or transients on the vehicle BUS voltages. This portable instrumentation is removed while performing close out operations before the vehicle launch. For the ML-1 lightning instrumentation system, new custom B-dot and D-dot sensors were designed and prototypes were tested at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, Florida. The Ground Special Power (GSP) vehicle measurement channels monitoring on the ML-1 is done via 1) Commercial off-the-shelf (COTS) current shunts and 2) custom Voltage Dividers. The new ML-1 lightning instrumentation system was designed, fabricated, deployed, and tested prior to the summer of 2019, in preparation for the first NASA's SLS mission to be launched from the Launch Complex 39B (LC-39B). The ML-1 lightning instrumentation was designed to complement the LC-39B lightning instrumentation system providing electromagnetic measurements closer to the vehicle, at different heights and inside the Crew capsule module.

Angel G Mata↗