Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Stereotactic Radiofrequency Ablation (SRFA) of Liver Lesions: Technique Effectiveness, Safety, and Interoperator Performance

Purpose: To evaluate technique effectiveness, safety, and interoperator performance of stereotactic radiofrequency ablation (SRFA) of liver lesions. Methods: Retrospective review including 90 consecutive patients from January 2008 to January 2010 with 106 computed tomography-guided SRFA sessions using both single and multiple electrodes for the treatment of 177 lesions: 72 hepatocellular carcinoma (HCC) and 105 metastases with a mean size of 2.9 cm (range 0.5-11 cm). Technique effectiveness and 1-year local recurrence were evaluated by computed tomographic scans. Complications, mortality, and hospital days were recorded. The performance between an experienced and inexperienced interventional radiologist was compared. Results: The overall technique effectiveness after a single SRFA was 95.5% (93.1% for HCC and 97.1% for metastases). Four of the eight unsuccessfully treated lesions could be retreated (secondary technique effectiveness of 97.7%). Local recurrence at 1 year was 2.9%. Technique effectiveness was significantly different for lesions <5 cm (96.7%) and >5 cm (87.5%) (P = 0.044) but not for lesions <3 cm (95.9%) and 3-5 cm (100%). Compared to clear parenchymal property (97.3%), vessel vicinity (93.3%) (P = 0.349) and subcapsular (95.2%) (P = 0.532) had no, but hollow viscera vicinity (83.3%) had a significantly lower technique effectiveness (P = 0.020). Mortality rate was 0.9%. Major complications and hospital days were higher for cirrhosis Child-Pugh B (20%, 7.2 days) than Child-Pugh A (3.1%, 4.7 days) patients and for metastases (5.1%, 4.3 days). There was no significant difference in interoperator performance. Conclusions: RFA allowed for efficient, reliable, and safe ablation of large-volume liver disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postoperative Radiotherapy for Lung Cancer: Improvement in Locoregional Control Using Three-Dimensional Compared With Two-Dimensional Technique

Purpose: To determine whether lung cancer patients treated with three-dimensional (3D) postoperative radiotherapy (PORT) have more favorable outcomes than those treated with two-dimensional (2D) PORT. Patients and Methods: We retrospectively analyzed the charts of 153 lung cancer patients who underwent PORT with curative intent at our center between 1995 and 2007. The patients were grouped according to the RT technique; 66 patients were in the 2D group and 87 in the 3D group. The outcomes included locoregional control, survival, and secondary effects. All patients were treated using a linear accelerator at a total dose of approximately 50 Gy and 2 Gy/fraction. A few patients (21%) also received chemotherapy. Most tumors were in the advanced stage, either Stage II (30%) or Stage III (65%). The main clinical indications for PORT were positive resection margins (23%) and Stage pN2 (52%) and pN1 (22%). The patient characteristics were comparable in both groups. Results: Kaplan-Meier analysis showed that the 3D technique significantly improved the locoregional control rate at 5 years compared with the 2D technique (81% vs. 56%, p = .007 [Cox]). The 2D technique was associated with a more than twofold increased risk of locoregional recurrence (hazard ratio, 2.7; 95% confidence interval, 1.3-5.5; p = .006). The overall survival rate did not differ at 5 years (38% vs. 20%, p = .3 [Cox]). The toxicities were also similar and acceptable in both groups. Conclusion: The 3D technique for conformal PORT for lung cancer improved the locoregional control rates of patients compared with the 2D technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determining local thermal transport in a composite uranium-nitride/silicide nuclear fuel using square-pulse transient thermoreflectance technique

Laser-based techniques have become an appealing option for determining the thermal diffusivities (D) and conductivities (k) of nuclear materials that would otherwise prove too hazardous or difficult to measure otherwise. These techniques have enabled non-destructive and non-contact thermal transport measurements with micron-level spatial resolution. In this study, a new time-domain technique known as square-wave pulse thermoreflectance (SPTR) is described and used to determine D values of both uranium sesquisilicide (U 3 Si 2 ) and uranium nitride (UN) phases in a composite fuel. An extensive sensitivity analysis was conducted that identified the optimal measurement parameters of standard materials with a range of thermal transport properties comparable to those of various fuel types. The standards were measured using both SPTR as well as a spatial-domain thermoreflectance technique (SDTR). Several U 3 Si 2 and UN phase regions of polished UN/U 3 Si 2 (70/30 vol.%) samples were measured using both methods, and the resulting calculated D and k values are reported, with both techniques showing excellent agreement between samples. Finally, the ability to use the technique for local diffusivity mapping was demonstrated over a multiphase region, and could be used to determine thermal transport properties in precipitates, secondary phases, and irradiation-damaged regions of post-irradiated fuel samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Survey of Techniques for Modeling and Improving Reliability of Computing Systems

Recent trends of aggressive technology scaling have greatly exacerbated the occurrences and impact of faults in computing systems. This has made `reliability' a first-order design constraint. To address the challenges of reliability, several techniques have been proposed. In this study, we provide a survey of architectural techniques for improving resilience of computing systems. We especially focus on techniques proposed for microarchitectural components, such as processor registers, functional units, cache and main memory etc. In addition, we discuss techniques proposed for non-volatile memory, GPUs and 3D-stacked processors. To underscore the similarities and differences of the techniques, we classify them based on their key characteristics. We also review the metrics proposed to quantify vulnerability of processor structures. Finally, we believe that this survey will help researchers, system-architects and processor designers in gaining insights into the techniques for improving reliability of computing systems.

3D-stacked processors↗

A Load-based Depth-sensing Indentation Technique for NDE and Life Assessment of Thermal Barrier Coatings

In this paper, we present a load-based micro-indentation technique for evaluating material mechanical properties as well as degradation evaluation and debonding/spallation detection of thermal barrier coating (TBC) materials. Instead of using contact area as a necessary parameter, the new technique is based on the indentation load. Coupled with a multiple-partial unloading procedure during the indentation process, this technique results in a load-depth sensing indentation system capable of determining Young’s modulus of metals, superalloys, and single crystal matrices, and stiffness of coated material systems with flat, tubular, or curved architectures. This micro-indentation technique can be viewed as a viable non-destructive evaluation (NDE) technique for determining as-manufactured and process-exposed metal, superalloy, single crystal, and TBC-coated material properties. This technique also shows promise for the development of a portable instrument for on-line, in-situ NDE and mechanical properties measurement of structural components.

36 MATERIALS SCIENCE↗

A Load-based Micro-indentation Technique for Mechanical Property and NDE Evaluation

A load-based micro-indentation technique has been developed for evaluating mechanical properties of materials. Instead of using measured indentation depth or contact area as a necessary parameter, the new technique is based on the indentation load, coupled with a multiple-partial unloading procedure for mechanical property evaluation. The proposed load-based micro-indentation method is capable of determining Young’s modulus of metals, superalloys, and single crystal matrices, and stiffness of coated material systems with flat, tubular, or curved architectures. This micro-indentation technique can be viewed as a viable non-destructive evaluation (NDE) technique for determining as-manufactured and process-exposed metal, superalloy, single crystal, and TBC-coated material properties. Based on this technique, several bond coated substrates were tested at various stages of thermal cycles. The time-series evaluation of test material surface stiffness reveals the status of coating strength without any alternation of the coating surface, making it a true time-series NDE investigation. The microindentation test results show good correlation with post mortem microstructural analyses. This technique also shows promise for the development of a portable instrument for on-line, in-situ NDE and mechanical properties measurement of structural components.

36 MATERIALS SCIENCE↗

A Method to Test Model Calibration Techniques: Preprint

This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Method to Test Model Calibration Techniques

This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Diffusion-weighted imaging as a part of PET/MR for small lesion detection in patients with primary abdominal and pelvic cancer, with or without TOF reconstruction technique

Objectives: To investigate the value of diffusion-weighted imaging (DWI) in detection of small lesions (≤ 10 mm) in patients with primary abdominal and pelvic cancer in hybrid PET/MR with or without time-of-flight (TOF) technique. Materials and methods: Twenty patients (11 females and 9 males, mean age 67.23 ± 12.90 years) with histologically confirmed primary abdominal and pelvic cancer underwent hybrid PET/MR examination. A total of 64 small lesions were included in this study, which were divided into two groups (≤ 10 mm and 10–30 mm). Visual scores of small lesion detection ability were rated by five-point ordinal scale. The visual scores and detectability of small lesions on TOF PET image, noTOF PET image, and DWI sequences of hybrid PET/MR examination with or without TOF technique were analyzed. Logistic regression model was established for analysis in the value of DWI in hybrid PET/MR examination with or without TOF technique in detection of the small lesions between two groups. Results: The visual evaluation revealed the small lesion (≤ 10 mm) visual scores of DWI (mean ± SD: 4.23 ± 1.41), TOF PET image (mean ± SD: 4.14 ± 0.89), and noTOF PET image (mean ± SD: 2.68 ± 1.13);.and the visual scores of small lesions (10–30 mm) on DWI (mean ± SD: 4.98 ± 0.15), TOF PET image (mean ± SD: 4.57 ± 0.59), and noTOF PET image (mean ± SD: 3.98 ± 1.05). The visual scores of all small lesions on DWI were higher than that on TOF PET data and noTOF PET data in both two groups (**P < 0.01). The missed diagnosis rates of small FDG avid lesions (≤ 10 mm) of DWI and noTOF PET image were 9.1% and 9.1%, respectively. However, the TOF PET-based clinical diagnosis detected all small lesions (≤ 30 mm). DWI was of great importance in detection of small lesions (≤ 10 mm) in the absence of TOF technique in PET/MR examination (**P < 0.01). DWI’s effect on detection of small lesions(10-30 mm) has shown no difference between PET/MR examinations with TOF and without TOF techniques (P > 0.05). Conclusion: DWI has significant value in the detection of small lesions (≤ 10 mm) in hybrid PET/MR examination without TOF technique for patients with primary abdominal and pelvic cancer. However, it had less detection benefits in the small lesions (≤ 10 mm) in hybrid PET/MR examination with TOF PET image.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Replacement of Mushroom Cage Gastrostomy Tube Using a Modified Technique to Allow Percutaneous Replacement with an Endoscopic Tube in Patients with Amyotrophic Lateral Sclerosis

Radiologic inserted gastrostomy (RIG) is the preferred method in our institution for enteral feeding in amyotrophic lateral sclerosis (ALS). Skin-level primary-placed mushroom cage gastrostomy tubes become tight with weight gain. We describe a minimally invasive radiologic technique for replacing mushroom gastrostomy tubes with endoscopic mushroom cage tubes in ALS. All patients with ALS who underwent replacement of a RIG tube were included. Patients were selected for a modified replacement when the tube length of the primary placed RIG tube was insufficient to allow like-for-like replacement. Replacement was performed under local anesthetic and fluoroscopic guidance according to a preset technique, with modification of an endoscopic mushroom cage gastrostomy tube to allow percutaneous placement. Assessment of the success, safety, and durability of the modified technique was undertaken. Over a 60-month period, 104 primary placement mushroom cage tubes in ALS were performed. A total of 20 (19.2%) of 104 patients had a replacement tube positioned, 10 (9.6%) of 104 with the modified technique (male n = 4, female n = 6, mean age 65.5 years, range 48-85 years). All tubes were successfully replaced using this modified technique, with two minor complications (superficial wound infection and minor hemorrhage). The mean length of time of tube durability was 158.5 days (range 6-471 days), with all but one patient dying with a functional tube in place. We have devised a modification to allow percutaneous replacement of mushroom cage gastrostomy feeding tubes with minimal compromise to ALS patients. This technique allows tube replacement under local anesthetic, without the need for sedation, an important consideration in ALS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safe Removal of an Encrusted Nephrostomy Tube Using a Vascular Sheath: A Technique Revisited

With the advent of interventional radiology and the decrease in mortality from chronic ailments, especially malignancy, percutaneous nephrostomy has become a commonly used safe technique for temporary relief of renal tract obstruction or for urinary diversion. However, these are associated with risks of infection, particularly septicaemia, colonisation, and blockage. Another significant complication is difficulty in removal due to encrustation. We describe a useful technique used in our department for the past few years and cite four cases of variable presentation and complexity for removal of an encrusted nephrostomy tube. No mention of this technique was found recent literature. An almost similar technique was described in the 1980s ''Pollack and Banner (Radiology 145:203-205, 1982), Baron and McClennan (Radiology 141:824, 1981)''. It is possible that experienced operators may have used this technique. We revisit it with pictographic representation, describing its use with currently available equipment, for benefit of operators who are not aware of this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Results After Prostatic Artery Embolization Using the PErFecTED Technique: A Single-Center Study

BackgroundProstatic artery embolization (PAE) has been performed for a few years, but there is no report on PAE using the PErFecTED technique outside from the team that initiated this approach.ObjectiveThis single-center retrospective open label study reports our experience and clinical results on patients suffering from symptomatic BPH, who underwent PAE aiming at using the PErFecTED technique.Materials and MethodsWe treated 32 consecutive patients, mean age 65 (52–84 years old) between December 2013 and January 2015. Patients were referred for PAE after failure of medical treatment and refusal or contra-indication to surgery. They were treated using the PErFecTED technique, when feasible, with 300–500 µm calibrated microspheres (two-night hospital stay or outpatient procedure). Follow-up was performed at 3, 6, and 12 months.ResultsWe had a 100 % immediate technical success of embolization (68 % of feasibility of the PErFecTED technique) with no immediate complications. After a mean follow-up of 7.7 months, we observed a 78 % rate of clinical success. Mean IPSS decreased from 15.3 to 4.2 (p = .03), mean QoL from 5.4 to 2 (p = .03), mean Qmax increased from 9.2 to 19.2 (p = .25), mean prostatic volume decreased from 91 to 62 (p = .009) mL. There was no retrograde ejaculation and no major complication.ConclusionPAE using the PErFecTED technique is a safe and efficient technique to treat bothersome LUTS related to BPH. It is of interest to note that the PErFecTED technique cannot be performed in some cases for anatomical reasons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review of Solid State Consolidation Processing Techniques of ODS Steels (Hot Extrusion, Hot Isostatic Pressing, Spark Plasma Sintering, and Stir Friction Consolidation): Resulting Microstructures and Mechanical Properties

This paper reviews the solid-state consolidation processing techniques for Oxide Dispersion Strengthened steels and compares them in terms of the resulting microstructure and reported mechanical properties. Synthesis techniques include hot extrusion, hot isostatic pressing, spark plasma sintering and friction consolidation. The effects of process parameters on the resulting microstructures and performance are discussed for each technique. Average oxide size, average grain size, and porosity are compared across techniques, as well as mechanical strength and ductility. Across consolidation techniques where temperature can be controlled, a low sintering temperature with a high sintering pressure is favorable for keeping oxide sizes, grain sizes, and porosity low. The use of yttrium and titanium for oxide formation has been evidenced to reduce oxide sizes, and tungsten additions have been shown to improve strength. Current literature suggests that the more mature hot extrusion technique produces stronger steel with consistently fine oxides, while other alternative solid-state consolidation, while promising, offer margin for improvement.

36 MATERIALS SCIENCE↗

Comparison of time-frequency-analysis techniques applied in building energy data noise cancellation for building load forecasting: A real-building case study

Time-frequency analysis that disaggregates a signal in both time and frequency domain is an important supporting technique for building energy analysis such as noise cancellation in data-driven building load forecasting. There is a gap in the literature related to comparing various time–frequency-analysis techniques, especially discrete wavelet transform (DWT) and empirical mode decomposition (EMD), to guide the selection and tuning of time–frequency-analysis techniques in data-driven building load forecasting. This article provides a framework to conduct a comprehensive comparison among thirteen DWT/EMD techniques with various parameters in a load forecasting modeling task. A real campus building is used as a case study for illustration. The DWT and EMD techniques are also compared under various data-driven modeling algorithms for building load forecasting. The results in the case study show that the load forecasting models trained with noise-cancelled energy data have increased their accuracy to 9.6% on average tested under unseen data. This study also shows that the effectiveness of DWT/EMD techniques depends on the data-driven algorithms used for load forecasting modeling and the training data. Hence, DWT/EMD-based noise cancellation needs customized selection and tuning to optimize their performance for data-driven building load forecasting modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Selenium contamination, consequences and remediation techniques in water and soils: A review

Highlights: • Se contamination in environment emerged as a serious threat. • Se causes various several fatal diseases in human beings and animals. • Various treatment techniques for Se removal from water and soil are reviewed. • Adsorption and membrane separation are seemed to be suitable on a commercial scale. • The knowledge gaps to be addressed are proposed. Selenium (Se) contamination in surface and ground water in numerous river basins has become a critical problem worldwide in recent years. The exposure to Se, either direct consumption of Se or indirectly may be fatal to the human health because of its toxicity. The review begins with an introduction of Se chemistry, distribution and health threats, which are essential to the remediation techniques. Then, the review provides the recent and common removal techniques for Se, including reduction techniques, phytoremediation, bioremediation, coagulation-flocculation, electrocoagulation (EC), electrochemical methods, adsorption, coprecipitation, electrokinetics, membrance technology, and chemical precipitation. Removal techniques concentrate on the advantages, drawbacks and the recent achievements of each technique. The review also takes an overall consideration of experimental conditions, comparison criteria and economic aspects.

54 ENVIRONMENTAL SCIENCES↗

“The development of a through-plane reactive excitation technique for detection of pinholes in membrane-containing MEA sub-assemblies”

As markets for polymer-electrolyte-membrane fuel cells (PEMFC) expand, there continues to be a need for the development and implementation of in-line quality inspection techniques to enable high-volume manufacturing methods for membrane-electrode assemblies (MEAs). These techniques mitigate the potential impact of poor quality on the cost of MEA components by real-time identification of process-induced irregularities, which can result from the manufacturing process or subsequent handling of the material during assembly into a full MEA. A particular type of irregularity known to impact MEA lifetime is loss of membrane integrity, e.g. via a pinhole. In this work, we focus on development of a technique to detect pinholes in membrane-containing MEA sub-assemblies - as opposed to in just the membrane - using a reactive excitation strategy coupled with infrared thermography for detection. A specialized device is introduced and, using various MEA sub-assemblies, is shown to enable detection of pinholes in stationary samples. Multi-physics modeling is utilized to understand and predict the impact of various design and operational parameters of this technique. The feasibility of the technique is demonstrated through both modeling and in-situ results. For example, a detectable (≥1 degree C) thermal response for a membrane pinhole of approximately 90 um in diameter is measured in a fraction of a second. The observed detection time is considered to be appropriate for further exploration of the technique in an in-line configuration.

30 DIRECT ENERGY CONVERSION↗

Dosimetric Comparison of Bone Marrow-Sparing Intensity-Modulated Radiotherapy Versus Conventional Techniques for Treatment of Cervical Cancer

Purpose: To compare bone marrow-sparing intensity-modulated pelvic radiotherapy (BMS-IMRT) with conventional (four-field box and anteroposterior-posteroanterior [AP-PA]) techniques in the treatment of cervical cancer. Methods and Materials: The data from 7 cervical cancer patients treated with concurrent chemotherapy and IMRT without BMS were analyzed and compared with data using four-field box and AP-PA techniques. All plans were normalized to cover the planning target volume with the 99% isodose line. The clinical target volume consisted of the pelvic and presacral lymph nodes, uterus and cervix, upper vagina, and parametrial tissue. Normal tissues included bowel, bladder, and pelvic bone marrow (PBM), which comprised the lumbosacral spine and ilium and the ischium, pubis, and proximal femora (lower pelvis bone marrow). Dose-volume histograms for the planning target volume and normal tissues were compared for BMS-IMRT vs. four-field box and AP-PA plans. Results: BMS-IMRT was superior to the four-field box technique in reducing the dose to the PBM, small bowel, rectum, and bladder. Compared with AP-PA plans, BMS-IMRT reduced the PBM volume receiving a dose >16.4 Gy. BMS-IMRT reduced the volume of ilium, lower pelvis bone marrow, and bowel receiving a dose >27.7, >18.7, and >21.1 Gy, respectively, but increased dose below these thresholds compared with the AP-PA plans. BMS-IMRT reduced the volume of lumbosacral spine bone marrow, rectum, small bowel, and bladder at all dose levels in all 7 patients. Conclusion: BMS-IMRT reduced irradiation of PBM compared with the four-field box technique. Compared with the AP-PA technique, BMS-IMRT reduced lumbosacral spine bone marrow irradiation and reduced the volume of PBM irradiated to high doses. Therefore BMS-IMRT might reduce acute hematologic toxicity compared with conventional techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Breast Cancer Regional Radiation Fields for Supraclavicular and Axillary Lymph Node Treatment: Is a Posterior Axillary Boost Field Technique Optimal?

Purpose: To assess whether using an anterior oblique supraclavicular (SCV) field with a posterior axillary boost (PAB) field is an optimal technique for targeting axillary (AX) lymph nodes compared with two computed tomography (CT)-based techniques: (1) an SCV field with an anterior boost field and (2) intensity-modulated radiotherapy (IMRT). Methods and Materials: Ten patients with CT simulation data treated with postmastectomy radiation that included an SCV field were selected for the study. Supraclavicular nodes and AX Level I-III nodes within the SCV field were contoured and defined as the treatment target. Plans using the three techniques were generated and evaluated for each patient. Results: The anterior axillary boost field and IMRT resulted in superior dose coverage compared with PAB. Namely, treatment volumes that received 105%, 80%, and 30% of prescribed dose for IMRT plans were significantly less than those for the anterior axillary boost plans, which were significantly less than PAB. For PAB and anterior axillary boost plans, there was a linear correlation between treatment volume receiving 105% of prescribed dose and maximum target depth. Furthermore, the IMRT technique resulted in better lung sparing and dose conformity to the target than anterior axillary boost, which again was significantly better than PAB. The maximum cord dose for IMRT was small, but higher than for the other two techniques. More monitor units were required to deliver the IMRT plan than the PAB plan, which was more than the anterior axillary boost plan. Conclusions: The PAB technique is not optimal for treatment of AX lymph nodes in an SCV field. We conclude that CT treatment planning with dose optimization around delineated target volumes should become standard for radiation treatments of supraclavicular and AX lymph nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗