At least 361 records · Page 20

Physics-Guided Deep Learning for Time-Series State Estimation Against False Data Injection Attacks

The modern power grid is a cyber-physical system. While the grid is becoming more intelligent with emerging sensing and communication techniques, new vulnerabilities are introduced and cyber security becomes a major concern. One type of cyber-attacks - False Data Injection Attacks (FDIAs) - exploits the limitations in traditional power system state estimation, and modifies system states without being detected. In this paper, we propose a physics-guided deep learning (PGDL) approach to defend against FDIAs. The PGDL takes real-time measurements as inputs to neural networks, outputs the estimated states, and reconstructs measurements considering power system physics. A deep recurrent neural network - Long Short-Term Memory (LSTM) - is employed to learn the temporal correlations among states. This hybrid learning model leads to a time-series state estimation method to defend against FDIAs. The simulation results using IEEE 14-bus test system demonstrate the accuracy and robustness of the proposed time-series state estimation under FDIAs.

Cyber security, state estimation, physics-guided d↗

2014 Semi-Annual Progress Letter Report on Used Nuclear Fuel Integrity Study in Transportation Environments

The objective of this project is to perform a systematic study on UNF (Used Nuclear Fuel) integrity under simulated transportation environments by using enabling hot-cell testing technology developed recently at ORNL, CIRFT (Cyclic Integrated Reversible-Bending Fatigue Tester) [1-9]. Out-of-cell study will support the ongoing ORNL hot-cell or in-cell testing. Although the use of CIRFT on H. B. Robinson UNF rods generated many interesting data, a number of important issues remain to be addressed arising from the test system and the rod itself. It has been shown that a direct examination of some of these issues in the hot-cell is prohibitive due to high cost and access limitations. The out-of-cell study has been demonstrated to be cost effective and much more feasible to provide quick turn-around solutions. A testing system with the same configuration as that of CIRFT used in hot-cell has been proposed to study the emerging issues from hot-cell testing and also to investigate the fatigue and failure mechanisms of UNF rods that cannot be identified directly with in hot-cell testing. The developments of hardware and software, test protocol, and hot-cell data analysis will be discussed in this report.

Normal Transportation↗

Filter Measurement System for Nuclear Material Storage Canisters - Midyear Report FY 2013

A test system is being developed at Los Alamos National Laboratory to measure the aerosol collection efficiency of filters in the lids of canisters for storing special nuclear materials (Figure 1). Two FTS (filter test rig) systems are being constructed; one system (the “TA-55 system”) will be used in the LANL TA-55 facility with canister lids that have been exposed to nuclear material. The other FTS device (the “TA-3 system”) will be used in the LANL Radiation Protection group RP-2 Aerosol Engineering Facility. The “TA-3 system” will have an expanded analytical capability, compared to the “TA-55 system” system that will be used for operational performance testing.

61 RADIATION PROTECTION AND DOSIMETRY↗

Risk-Based Distributionally Robust Optimal Power Flow With Dynamic Line Rating

In this paper, we propose a risk-based data-driven distributionally robust approach to investigating the optimal power flow with dynamic line rating. The risk terms, including penalties for load shedding, wind generation curtailment and line overload, are embedded into the objective function. To robustify the solution, we consider a distributional uncertainty set based on the second-order moment, that captures the correlation between wind generation outputs and line ratings, and also the Wasserstein distance, that hedges against data perturbations. We show that the proposed model can be reformulated as a convex conic program. Approximations of the proposed model are suggested, which leads to a significant reduction of the number of the constraints. For practical large-scale test systems, a distributionally robust optimal power flow model with Wasserstein-distance-based distributional uncertainty set and its convex reformulation are also provided. Simulation results on the 5-bus, the IEEE 118-bus and the Polish 2736-bus test systems validate the effectiveness of the proposed models.

distributionally robust optimization↗

Effects of Crude Oil, Dispersant, and Oil-Dispersant Mixtures on Human Fecal Microbiota in an In Vitro Culture System

The Deepwater Horizon oil spill of 2010 raised concerns that dispersant and dispersed oil, as well as crude oil itself, could contaminate shellfish and seafood habitats with hazardous residues that had potential implications for human health and the ecosystem. However, little is known about the effects of crude oil and dispersant on the human fecal microbiota. The aim of this research was to evaluate the potential effects of Deepwater Horizon crude oil, Corexit 9500 dispersant, and their combination on human fecal microbial communities, using an in vitro culture test system. Fecal specimens from healthy adult volunteers were made into suspensions, which were then treated with oil, dispersant, or oil-dispersant mixtures under anaerobic conditions in an in vitro culture test system. Perturbations of the microbial community, compared to untreated control cultures, were assessed using denaturing gradient gel electrophoresis (DGGE), real-time PCR, and pyrosequencing methods. DGGE and pyrosequencing analysis showed that oil-dispersant mixtures reduced the diversity of fecal microbiota from all individuals. Real-time PCR results indicated that the copy numbers of 16S rRNA genes in cultures treated with dispersed oil or oil alone were significantly lower than those in control incubations. The abundance of the Bacteroidetes decreased in crude oil-treated and dispersed-oil-treated cultures, while the Proteobacteria increased in cultures treated with dispersed oil. In conclusion, the human fecal microbiota was affected differently by oil and dispersed oil, and the influence of dispersed oil was significantly greater than that of either oil or dispersant alone compared to control cultures.

54 ENVIRONMENTAL SCIENCES↗

Optimal Power System Black start using Inverter-Based Generation

Power system black start readiness is part of the system planning. Utility planners perform periodic studies to assess if their power system is capable of total restoration following a black out. Hydro and diesel generators are the most commonly used black start capable resources by power utilities. However, with increasing penetration of solar generation, inverter-based resources can be considered to provide black start capability. Since the solar inverters can be located at multiple locations throughout the power system, and in view of their unique characteristics, an optimal real-time capable plan is helpful for system operators for faster black start. Black start optimization is a multi stage mixed-integer non-linear optimization which is extremely hard to solve. In this paper, we propose an optimal black start methodology that is easier to solve and scalable in real-time. We demonstrate the proposed methodology on two test systems and illustrate how inverter-based resources can contribute and improve power system restoration.

power system restoration, blackstart, Inverter-bas↗

Corrective Action Investigation Plan for Corrective Action Unit 562: Waste Systems Nevada Test Site, Nevada, Revision 0

Corrective Action Unit 562 is located in Areas 2, 23, and 25 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 562 is comprised of the 13 corrective action sites (CASs) listed below: • 02-26-11, Lead Shot • 02-44-02, Paint Spills and French Drain • 02-59-01, Septic System • 02-60-01, Concrete Drain • 02-60-02, French Drain • 02-60-03, Steam Cleaning Drain • 02-60-04, French Drain • 02-60-05, French Drain • 02-60-06, French Drain • 02-60-07, French Drain • 23-60-01, Mud Trap Drain and Outfall • 23-99-06, Grease Trap • 25-60-04, Building 3123 Outfalls These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation before evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on December 11, 2008, by representatives of the Nevada Division of Environmental Protection; U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture; and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 562. Appendix A provides a detailed discussion of the DQO methodology and the DQOs specific to each CAS. The scope of the corrective action investigation for CAU 562 includes the following activities: • Move surface debris and/or materials, as needed, to facilitate sampling. • Conduct radiological surveys. • Perform field screening. • Collect and submit environmental samples for laboratory analysis to determine the nature and extent of any contamination released by each CAS. • Collect samples of source material to determine the potential for a release. • Collect samples of potential remediation wastes. • Collect quality control samples. This Corrective Action Investigation Plan has been developed in accordance with the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; DOE, Environmental Management; U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996; as amended February 2008). Under the Federal Facility Agreement and Consent Order, this Corrective Action Investigation Plan will be submitted to the Nevada Division of Environmental Protection for approval. Fieldwork will be conducted following approval of the plan.

54 ENVIRONMENTAL SCIENCES↗

Customer interface document for the Molten Salt Test Loop (MSTL) system

The National Solar Thermal Test Facility at Sandia National Laboratories has a unique test capability called the Molten Salt Test Loop (MSTL) system. MSTL is a test capability that allows customers and researchers to test components in flowing, molten nitrate salt. The components tested can range from materials samples, to individual components such as flex hoses, ball joints, and valves, up to full solar collecting systems such as central receiver panels, parabolic troughs, or linear Fresnel systems. MSTL provides realistic conditions similar to a portion of a concentrating solar power facility. The facility currently uses 60/40 nitrate 'solar salt' and can circulate the salt at pressure up to 600psi, temperature to 585 C, and flow rate of 400-600GPM depending on temperature. The purpose of this document is to provide a basis for customers to evaluate the applicability to their testing needs, and to provide an outline of expectations for conducting testing on MSTL. The document can serve as the basis for testing agreements including Work for Others (WFO) and Cooperative Research and Development Agreements (CRADA). While this document provides the basis for these agreements and describes some of the requirements for testing using MSTL and on the site at Sandia, the document is not sufficient by itself as a test agreement. The document, however, does provide customers with a uniform set of information to begin the test planning process.

14 SOLAR ENERGY↗

System Response Testing of HEAF Kevex 130kV Microfocus Source and Thales Flashscan Panel I. Step-wedge Measurements

In the Small Sample DR Testing series, a few questions have arisen when comparing modeled results to experimental data. It is necessary to evaluate these questions in order to validate the modeling assumptions and to ensure the validity of the test procedure in the Small Sample DR Testing. Open Questions: (1) The decay time of the scintillator elements is unknown. (2) The thickness of the Beryllium window on the source is unknown. (3) The residual effects of beam angle and scattering within the detector assembly are unknown. (4) The spectral response of the scintillator and digitizing panel are not known. (5) The spectral content of the source is unknown. Item 1 will be addressed in separate tests by measuring the output of the panel at various intervals after the source has stopped illuminating the panel. Item 2 will be determined by finding the manufacturer specifications. Item 3 will be addressed in separate tests. We cannot easily address items 4 and 5 independently. Measuring the spectral responsivity of the detector directly would require the use of a calibrated reference source, which we lack. Similarly, measuring the spectral content of the source requires spectrally and spatially calibrated detectors, which we also lack. However, we can address the combination of items 1 and 2 to deduce the product of source intensity times detector response. By measuring the X-ray transmittance of samples of known thickness, material composition and density (step wedges), we can infer the desired product and so validate and improve computer models of our system.

47 OTHER INSTRUMENTATION↗

Corrective Action Investigation Plan for Corrective Action Unit 560: Septic Systems, Nevada Test Site, Nevada with ROTC1, Revision 0

Corrective Action Unit (CAU) 560 is located in Areas 3 and 6 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 560 is comprised of the seven corrective action sites (CASs) listed below: • 03-51-01, Leach Pit • 06-04-02, Septic Tank • 06-05-03, Leach Pit • 06-05-04, Leach Bed • 06-59-03, Building CP-400 Septic System • 06-59-04, Office Trailer Complex Sewage Pond • 06-59-05, Control Point Septic System These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation before evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on January 22, 2008, by representatives from the Nevada Division of Environmental Protection; U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture; and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 560.

54 ENVIRONMENTAL SCIENCES↗

The WRF-Solar Ensemble Prediction System: Development, Test, and Validation

Providing reliable probabilistic solar radiation information is needed to improve management of the uncertainty and variability of solar generation. Thus, guidance on how to develop skillful and accurate ensemble forecasts is essential and it will ultimately contribute to integration of high amounts of solar energy on the grid. A team from the National Renewable Energy Laboratory and the National Center for Atmospheric Research had been collaborating to develop the WRF-Solar ensemble prediction system (WRF-Solar EPS) in the past three years to produce probabilistic solar irradiance forecasts and better predict solar energy by quantifying forecast uncertainty. The WRF-Solar EPS basically generates ensemble members for solar irradiance based on stochastic perturbations to provide intraday and day-ahead probabilistic forecasts. This study will present main research steps in developing the WRF-Solar EPS including: (a) tangent linear analysis for identifying key input variables of six WRF-Solar modules significantly related to predicting of cloud and solar irradiance, (b) combining stochastic perturbation technique with the WRF-Solar model, and (c) ensemble calibration method to decrease error and uncertainty of ensemble-based solar forecasts. The capability of WRF-Solar EPS is now updated to the most recent version of standard WRF model. This presentation will summarize comprehensive results from the evaluation of forecasts against the National Solar Radiation Data Base as well as ground-measured observations. Moreover, we will introduce the user's guide for WRF-Solar EPS (e.g., parameters to configure stochastic perturbations) and future extension of this research.

day-ahead forecast↗

A geophysical shock and air blast simulator at the National Ignition Facility

The energy partitioning energy coupling experiments at the National Ignition Facility (NIF) have been designed to measure simultaneously the coupling of energy from a laser-driven target into both ground shock and air blast overpressure to nearby media. The source target for the experiment is positioned at a known height above the ground-surface simulant and is heated by four beams from the NIF. The resulting target energy density and specific energy are equal to those of a low-yield nuclear device. The ground-shock stress waves and atmospheric overpressure waveforms that result in our test system are hydrodynamically scaled analogs of full-scale seismic and air blast phenomena. This report summarizes the development of the platform, the simulations, and calculations that underpin the physics measurements that are being made, and finally the data that were measured. Agreement between the data and simulation of the order of a factor of two to three is seen for air blast quantities such as peak overpressure. Historical underground test data for seismic phenomena measured sensor displacements; we measure the stresses generated in our ground-surrogate medium. We find factors-of-a-few agreement between our measured peak stresses and predictions with modern geophysical computer codes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Systematic Approach to Better Understanding Integration Costs

This research presents a systematic approach to evaluating the costs of integrating new generation and operational procedures into an existing power system, and the methodology is independent of the type of change or nature of the generation. The work was commissioned by the U.S. Department of Energy and performed by the National Renewable Energy Laboratory to investigate three integration cost-related questions: (1) How does the addition of new generation affect a system's operational costs, (2) How do generation mix and operating parameters and procedures affect costs, and (3) How does the amount of variable generation (non-dispatchable wind and solar) impact the accuracy of natural gas orders? A detailed operational analysis was performed for seven sets of experiments: variable generation, large conventional generation, generation mix, gas prices, fast-start generation, self-scheduling, and gas supply constraints. For each experiment, four components of integration costs were examined: cycling costs, non-cycling VO&M costs, fuel costs, and reserves provisioning costs. The investigation was conducted with PLEXOS production cost modeling software utilizing an updated version of the Institute of Electrical and Electronics Engineers 118-bus test system overlaid with projected operating loads from the Western Electricity Coordinating Council for the Sacramento Municipal Utility District, Puget Sound Energy, and Public Service Colorado in the year 2020. The test system was selected in consultation with an industry-based technical review committee to be a reasonable approximation of an interconnection yet small enough to allow the research team to investigate a large number of scenarios and sensitivity combinations. The research should prove useful to market designers, regulators, utilities, and others who want to better understand how system changes can affect production costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Fast and Scalable Genetic Algorithm-Based Approach for Planning of Microgrids in Distribution Networks

As a result of climate change, extreme weather events are occurring more frequently and with increasing impact. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks; thus, the level of proactive preparation of the distribution system to be able to handle severe impacts of extreme weather events represents the system's resilience. One method that distribution system planners can use to prepare for future extreme events is to plan multiple microgrids which can use local generation as much as possible to supply critical loads. But partitioning an existing distribution system such that multiple feasible islands are planned and which are capable of supporting critical loads is still challenging for distribution systems - first, because of the size of the network graph partitioning problem and, second, because of the difficulty in properly formulating the desired attributes of such islands or microgrids. Therefore, this paper presents a genetic algorithm based approach that facilitates incorporating multiple objectives for grid partitioning by formulating two types of problems - node allocation and edge elimination - and it considers multiple topological and resilience-enhancing objectives. The performance of the proposed genetic algorithm-based approach is numerically evaluated on multiple test systems as well as on a real distribution feeder in Colorado, United States.

genetic algorithm↗

Identification of Intraday False Data Injection Attack on DER Dispatch Signals

The urgent need for the decarbonization of power grids has accelerated the integration of renewable energy. Concurrently, increasing distributed energy resources (DER) and advanced metering infrastructure (AMI) have transformed the power grids into a more sophisticated cyber-physical system with numerous communication devices. While these transitions provide economic and environmental value, they also impose increased risk of cyber attacks and operation al challenges. This paper investigates the vulnerabilit y of the power grids with high renewable penetration against an intraday false data injection (FDI) attack on DER dispatch signals and proposes a kernel support vector regression (SVR) based detection model as a countermeasure. The intraday FDI attack scenario and the detection model are demonstrated in a numerical experiment using the HCE 187-bus test system.

Kim, Jip↗

Insights into Methodologies and Operational Details of Resource Adequacy Assessment: A Case Study with Application to a Broader Flexibility Framework

Assessing and maintaining resource adequacy (RA) is a core pillar of power systems. However, recent changes in the physical makeup of these systems and the conditions under which these systems must operate have yielded a renewed interest in the methods, metrics, and assumptions that underpin RA assessments. In this paper, we systematically explore a wide range of RA modeling dimensions, including: the objective function and level of operational detail in the underlying model formulation; the quantity (look-ahead) and quality (accuracy) of data that is available for making operational decisions within those models; and the physical configuration of solar photovoltaics (PV) with battery storage hybrid resources. We apply a set of probabilistic RA tools and production cost modeling tools to a realistic test system based loosely on a future Electric Reliability Council of Texas power system dominated by solar PV resources. Under the assumptions of our system and models, we find that multi-stage probabilistic assessments may provide a more robust evaluation of RA by capturing a wider range of operational and system interactions, but this comes at a computational cost of 1-2 orders of magnitude longer run time depending on the specific configuration. In addition, the information on thermal generator availability impacts RA performance by an order of magnitude more than solar resource forecasts, which is driven by the comparatively larger magnitude of thermal outages than solar forecast errors within our test system. Lastly, the flexibility provided by hybrid and other resources can help reduce system load-shedding event frequencies and enable the system to be more robust to inaccurate forecast information, and alternative hybrid inverter sizes can impact RA levels by 1-2 orders of magnitude. Our results point to the importance of a broader flexibility framework to describe the interaction between (1) flexibility "supply" from both physical resource capabilities and operational constraints considered in the modeling, and (2) flexibility "demand" from forecast errors, thermal generator outages, and other sources of uncertainty, as well as their RA impacts. Results are likely sensitive to the system buildout explored; future work could consider additional system configurations and conditions.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Multi-Scale Thermal Analysis for Design of SiC-Based Medium Voltage Motor Drive: Preprint

This paper describes a multi-scale thermal analysis approach for the design of an air-cooled 1.7-kV SiC MOSFET-based medium-voltage variable-speed motor drive. The National Renewable Energy Laboratory supported the project objectives by providing thermal management design support to the project partner The Ohio State University (OSU). The scope of the models and limited resources required efficient and flexible thermal models to be developed. Two modeling techniques are described that significantly reduced model run time and enabled more complex models to be run faster while retaining needed accuracy. The first technique uses the effectiveness-NTU method to extract convection boundary conditions from a computational fluid dynamics (CFD) model that can be applied to a fast-running finite element analysis model. The second is a porous media technique that enables system-level CFD simulations that incorporate effects from heat exchangers (e.g., pin fin heat sinks) that run in a fraction of the time required for fully resolved CFD simulations. The multi-scale approach to the thermal analysis enabled fast and accurate simulation for the converter design ranging from the die level up to the full system with 36 submodules. The modeling results were validated against experimental data from system tests performed by OSU.

DIRECT ENERGY CONVERSION↗