Solar radiation measurement - Techniques and instrumentation

A general survey is presented of solar radiation measurement, techniques, and instrumentation. The importance of determining the total and spectral irradiance of the sun is examined in the context of the energy crisis and utilization of solar energy. The survey includes the extraterrestrial solar fluxes, their possible variations, problems relating to energy received by collecting surfaces on the ground, major types of instrumentation, and the radiation scales to which the measurements are referred. The type of insolation data available is reviewed. Alternate techniques of deriving insolation data with high space-time resolution are discussed with reference to solar energy conversion requirements. Energy received on the ground can be computed from known values of the extraterrestrial solar spectrum and of the spectral absorption parameters of the atmosphere. Another technique is based on measurements made by meteorological satellites of the cloud-cover and of the solar energy reflected and scattered back to space by the earth-atmosphere system.

Thekaekara, M. P.↗

Estimation of Dynamical Parameters in Atmospheric Data Sets

In this study a new technique is used to derive dynamical parameters out of atmospheric data sets. This technique, called the structure tensor technique, can be used to estimate dynamical parameters such as motion, source strengths, diffusion constants or exponential decay rates. A general mathematical framework was developed for the direct estimation of the physical parameters that govern the underlying processes from image sequences. This estimation technique can be adapted to the specific physical problem under investigation, so it can be used in a variety of applications in trace gas, aerosol, and cloud remote sensing. The fundamental algorithm will be extended to the analysis of multi- channel (e.g. multi trace gas) image sequences and to provide solutions to the extended aperture problem. In this study sensitivity studies have been performed to determine the usability of this technique for data sets with different resolution in time and space and different dimensions.

Wenig, Mark O.↗

Variations of Strahl Properties with Fast and Slow Solar Wind

The interplanetary solar wind electron velocity distribution function generally shows three different populations. Two of the components, the core and halo, have been the most intensively analyzed and modeled populations using different theoretical models. The third component, the strahl, is usually seen at higher energies, is confined in pitch-angle, is highly field-aligned and skew. This population has been more difficult to identify and to model in the solar wind. In this work we make use of the high angular, energy and time resolution and three-dimensional data of the Cluster/PEACE electron spectrometer to identify and analyze this component in the ambient solar wind during high and slow speed solar wind. The moment density and fluid velocity have been computed by a semi-numerical integration method. The variations of solar wind density and drift velocity with the general build solar wind speed could provide some insight into the source, origin, and evolution of the strahl.

Figueroa-Vinas, Adolfo↗

THEMIS Observations of Unusual Bow Shock Motion, Attending a Transient Magnetospheric Event

We present a multipoint case study of solar wind and magnetospheric observations during a transient magnetospheric compression at 2319 UT on October 15, 2008. We use high-time resolution magnetic field and plasma data from the THEMIS and GOES-11/12 spacecraft to show that this transient event corresponded to an abrupt rotation in the IMF orientation, a change in the location of the foreshock, and transient outward bow shock motion. We employ results from a global hybrid code model to reconcile the observations indicating transient inward magnetopause motion with the outward bow shock motion.

Korotova, Galina↗

Plasma potential mapping of high power impulse magnetron sputtering discharges

Pulsed emissive probe techniques have been used to determine the plasma potential distribution of high power impulse magnetron sputtering (HiPIMS) discharges. An unbalanced magnetron with a niobium target in argon was investigated for pulse length of 100 μs at a pulse repetition rate of 100 Hz, giving a peak current of 170 A. The probe data were taken with a time resolution of 20 ns and a spatial resolution of 1 mm. It is shown that the local plasma potential varies greatly in space and time. The lowest potential was found over the target’s racetrack, gradually reaching anode potential (ground) several centimeters away from the target. The magnetic pre-sheath exhibits a funnel-shaped plasma potential resulting in an electric field which accelerates ions toward the racetrack. In certain regions and times, the potential exhibits weak local maxima which allow for ion acceleration to the substrate. Knowledge of the local E and static B fields lets us derive the electrons’ E×B drift velocity, which is about 105 m/s and shows structures in space and time.

36 MATERIALS SCIENCE↗

Positron-emission tomography detector systems based on low-density liquid scintillators and precise time-resolving photodetectors

TOF-PET detector systems, and methods for imaging photon-emitting samples using the detector systems, are provided. The TOF-PET detector systems use large-area photodetectors with extremely high time-resolution and an approach to data collection and analysis that allows for the use of inexpensive low-density scintillator materials. The TOF-PET detector systems are characterized by their ability to identify, on a statistical basis, the transverse and depth location of the first of the series of energy deposition events that are generated when a gamma photon enters the low-density scintillator material.

Frisch, Henry J.↗

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗

Finite Element Methods for real-time Haptic Feedback of Soft-Tissue Models in Virtual Reality Simulators

We have applied the linear elastic finite element method to compute haptic force feedback and domain deformations of soft tissue models for use in virtual reality simulators. Our results show that, for virtual object models of high-resolution 3D data (>10,000 nodes), haptic real time computations (>500 Hz) are not currently possible using traditional methods. Current research efforts are focused in the following areas: 1) efficient implementation of fully adaptive multi-resolution methods and 2) multi-resolution methods with specialized basis functions to capture the singularity at the haptic interface (point loading). To achieve real time computations, we propose parallel processing of a Jacobi preconditioned conjugate gradient method applied to a reduced system of equations resulting from surface domain decomposition. This can effectively be achieved using reconfigurable computing systems such as field programmable gate arrays (FPGA), thereby providing a flexible solution that allows for new FPGA implementations as improved algorithms become available. The resulting soft tissue simulation system would meet NASA Virtual Glovebox requirements and, at the same time, provide a generalized simulation engine for any immersive environment application, such as biomedical/surgical procedures or interactive scientific applications.

Frank, Andreas O.↗

A fast-time-response extreme ultraviolet spectrometer for measurement of impurity line emissions in the Experimental Advanced Superconducting Tokamak

A flat-field extreme ultraviolet (EUV) spectrometer working in the 20-500 Å wavelength range with fast time response has been newly developed to measure line emissions from highly ionized tungsten in the Experimental Advanced Superconducting Tokamak (EAST) with a tungsten divertor, while the monitoring of light and medium impurities is also an aim in the present development. A flat-field focal plane for spectral image detection is made by a laminar-type varied-line-spacing concave holographic grating with an angle of incidence of 87°. A back-illuminated charge-coupled device (CCD) with a total size of 26.6 × 6.6 mm{sup 2} and pixel numbers of 1024 × 255 (26 × 26 μm{sup 2}/pixel) is used for recording the focal image of spectral lines. An excellent spectral resolution of Δλ{sub 0} = 3-4 pixels, where Δλ{sub 0} is defined as full width at the foot position of a spectral line, is obtained at the 80-400 Å wavelength range after careful adjustment of the grating and CCD positions. The high signal readout rate of the CCD can improve the temporal resolution of time-resolved spectra when the CCD is operated in the full vertical binning mode. It is usually operated at 5 ms per frame. If the vertical size of the CCD is reduced with a narrow slit, the time response becomes faster. The high-time response in the spectral measurement therefore makes possible a variety of spectroscopic studies, e.g., impurity behavior in long pulse discharges with edge-localized mode bursts. An absolute intensity calibration of the EUV spectrometer is also carried out with a technique using the EUV bremsstrahlung continuum at 20-150 Å for quantitative data analysis. Thus, the high-time resolution tungsten spectra have been successfully observed with good spectral resolution using the present EUV spectrometer system. Typical tungsten spectra in the EUV wavelength range observed from EAST discharges are presented with absolute intensity and spectral identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct measurements of tropospheric ozone from TOMS data

In the past year, we have made measurements of the tropospheric total column of ozone during the biomass burning season in Africa (August to October). Fishman et. al. had reported previously that by taking a time average of the low spatial resolution data from TOMS (Total Ozone Mapping Spectrometer) on Nimbus-7 (referred to as the Grid-T data set), during the biomass burning season in Africa, a plume of ozone extends from the East coast of Africa into the Atlantic. In this report, we present an analysis that we have made using the measured TOMS radiances taken from the High Density TOMS data set (referred as the HDT data set), which examines this plume in more detail.

Hudson, Robert D.↗

Detection of nuclear testing from surface concentration measurements: Analysis of radioxenon from the February 2013 underground test in North Korea

A method is outlined and tested to detect low level nuclear or chemical sources from time series of concentration measurements. The method uses a mesoscale atmospheric model to simulate the concentration signature from a known or suspected source at a receptor which is then regressed successively against segments of the measurement series to create time series of metrics that measure the goodness of fit between the signatures and the measurement segments. The method was applied to radioxenon data from the Comprehensive Test Ban Treaty (CTBT) collection site in Ussuriysk, Russia (RN58) after the Democratic People's Republic of Korea (North Korea) underground nuclear test on February 12, 2013 near Punggye. The metrics were found to be a good screening tool to locate data segments with a strong likelihood of origin from Punggye, especially when multiplied together to a determine the joint probability. Metrics from RN58 were also used to find the probability that activity measured in February and April of 2013 originated from the Feb 12 test. A detailed analysis of an RN58 data segment from April 3/4, 2013 was also carried out for a grid of source locations around Punggye and identified Punggye as the most likely point of origin. Thus, the results support the strong possibility that radioxenon was emitted from the test site at various times in April and was detected intermittently at RN58, depending on the wind direction. The method does not locate unsuspected sources, but instead, evaluates the probability of a source at a specified location. However, it can be extended to include a set of suspected sources. Extension of the method to higher resolution data sets, arbitrary sampling, and time-varying sources is discussed along with a path to evaluate uncertainty in the calculated probabilities.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Urban Air Quality Management at Low-Cost Using Micro Air Sensors: A Case Study From Accra, Ghana

Urban air quality management is dependent on the availability of local air pollution data. In many major urban centers of Africa, there is limited to non-existent information on air quality. This is gradually changing in part due to the increasing use of micro air sensors which have the potential to enable the generation of ground-based air quality data at fine scales for understanding local emission trends. Regional literature on the application of the high-resolution data for emission source identification in this region is limited. In this study a micro air sensor was co-located at the Physics Department, University of Ghana with a reference grade instrument to evaluate its performance for estimating PM2.5 pollution accurately at fine scales and the value of this data in identification of local sources and their behavior over time. For this study 15 weeks of data at hourly resolution with approximately 2500 data pairs are generated and analyzed (June 01, 2023, to September 15, 2023). For this time period a coefficient of determination (r 2 ) of 0.83 was generated with a mean absolute error (MAE) of 5.44 μgm -3 between the pre local calibration micro air sensor (i.e. out of box) and the reference-grade instrument. Following currently accepted best practice methods (see e.g., PAS4023) a domain specific (i.e. local) calibration factor was generated using a multi-linear regression model and when this factor is applied to the micro air sensor data, a reduction i.e., improvement in MAE to 1.43 μgm -3 was found. Daily variation was calculated, a receptor model was applied, and time series plots as a function of wind direction were generated, including PM2.5/PM10 ratio scatter and count plots to explore the utility of this observational approach for local source identification. The 3 data sets were compared (out of box, domain calibrated and reference-grade) and it was found that although there were variations in the data reported, source areas highlighted based on these data were similar, with input from local sources such as traffic emissions and biomass burning. As the temporal resolution of observational data associated with these micro air sensors is higher than for reference grade instruments (primarily due to costs and logistics limitations), they have the potential to provide insight into the complex, often hyper localized sources associated with urban areas, such as those found in major African cities.

Source apportionment↗

Interpolated Sounding and Gridded Sounding Value-Added Products

Standard Atmospheric Radiation Measurement (ARM) Climate Research Facility sounding files provide atmospheric state data in one dimension of increasing time and height per sonde launch. Many applications require a quick estimate of the atmospheric state at higher time resolution. The INTERPOLATEDSONDE (i.e., Interpolated Sounding) Value-Added Product (VAP) transforms sounding data into continuous daily files on a fixed time-height grid, at 1-minute time resolution, on 332 levels, from the surface up to a limit of approximately 40 km. The grid extends that high so the full height of soundings can be captured; however, most soundings terminate at an altitude between 25 and 30 km, above which no data is provided. Between soundings, the VAP linearly interpolates atmospheric state variables in time for each height level. In addition, INTERPOLATEDSONDE provides relative humidity scaled to microwave radiometer (MWR) observations.The INTERPOLATEDSONDE VAP, a continuous time-height grid of relative humidity-corrected sounding data, is intended to provide input to higher-order products, such as the Merged Soundings (MERGESONDE; Troyan 2012) VAP, which extends INTERPOLATEDSONDE by incorporating model data. The INTERPOLATEDSONDE VAP also is used to correct gaseous attenuation of radar reflectivity in products such as the KAZRCOR VAP.

54 ENVIRONMENTAL SCIENCES↗

Interpolated Sounding and Gridded Sounding Value-Added Products

Standard Atmospheric Radiation Measurement (ARM) Climate Research Facility sounding files provide atmospheric state data in one dimension of increasing time and height per sonde launch. Many applications require a quick estimate of the atmospheric state at higher time resolution. The INTERPOLATEDSONDE (i.e., Interpolated Sounding) Value-Added Product (VAP) transforms sounding data into continuous daily files on a fixed time-height grid, at 1-minute time resolution, on 332 levels, from the surface up to a limit of approximately 40 km. The grid extends that high so the full height of soundings can be captured; however, most soundings terminate at an altitude between 25 and 30 km, above which no data is provided. Between soundings, the VAP linearly interpolates atmospheric state variables in time for each height level. In addition, INTERPOLATEDSONDE provides relative humidity scaled to microwave radiometer (MWR) observations.

54 ENVIRONMENTAL SCIENCES↗

Reconstruction of high temporal resolution Thomson scattering data during a modulated electron cyclotron resonance heating using conditional averaging

This paper provides a software application of the sampling scope concept for fusion research. The time evolution of Thomson scattering data is reconstructed with a high temporal resolution during a modulated electron cyclotron resonance heating (MECH) phase. The amplitude profile and the delay time profile of the heat pulse propagation are obtained from the reconstructed signal for discharges having on-axis and off-axis MECH depositions. The results are found to be consistent with the MECH deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of Atmospheric, Laboratory, and Satellite Data to Estimate Biospheric Sources of Oxygenated Organic Compounds

For this study, we intend to use a long time series of coarse resolution (8 km and quarter degree) vegetation leaf area index (LAI) and fraction of absorbed PAR (FAPAR) derived from AVHRR data for the time period July 1981 through Dec 2001. The Global Inventory Monitoring and Modeling Studies (GIMMS) data set of AVHRR channel reflectances currently was developed by Dr. Tucker at NASA Goddard. The spatial resolution of the data is 8 km, and a 15-day maximum Normalized Difference Vegetation Index (NDVI) composite time series for the period July 1981 through December 1999 has been produced. The data processing included improved navigation, calibration for intra- and inter-sensor variations, partial atmospheric correction for gaseous absorption and scattering. Stratospheric aerosol effects associated with volcanic eruptions were corrected using a combination of the methods for the data from the period April 1982 - December 1984 (El Chichon) and June 1991 - December 1993 (Mt. Pinatubo).

Myneni, Ranga B.↗

Hierarchical Spatio-temporal Visual Analysis of Cluster Evolution in Electrocorticography Data

Here, we present ECoG ClusterFlow, a novel interactive visual analysis tool for the exploration of high-resolution Electrocorticography (ECoG) data. Our system detects and visualizes dynamic high-level structures, such as communities, using the time-varying spatial connectivity network derived from the high-resolution ECoG data. ECoG ClusterFlow provides a multi-scale visualization of the spatio-temporal patterns underlying the time-varying communities using two views: 1) an overview summarizing the evolution of clusters over time and 2) a hierarchical glyph-based technique that uses data aggregation and small multiples techniques to visualize the propagation of clusters in their spatial domain. ECoG ClusterFlow makes it possible 1) to compare the spatio-temporal evolution patterns across various time intervals, 2) to compare the temporal information at varying levels of granularity, and 3) to investigate the evolution of spatial patterns without occluding the spatial context information. Lastly, we present case studies done in collaboration with neuroscientists on our team for both simulated and real epileptic seizure data aimed at evaluating the effectiveness of our approach.

60 APPLIED LIFE SCIENCES↗

Time-resolved atomic-resolution Brownian tomography of single nanocrystals reveals size-dependent dynamics

Atomic-resolution structure identification of nanocrystals by graphene liquid cell electron microscopy (GLC-EM) has revealed that small, solubilized platinum nanocrystals consist of an ordered crystalline core surrounded by mobile surface atoms, which dissociate during oxidative etching, resulting in distinct temporal structural states. Requirements imposed by the 3D reconstruction algorithm limit the number of structural states that can be resolved. We introduce a regularized 3D reconstruction algorithm that exploits the redundancy inherent in the experimental data, allowing us to improve the time resolution. Our developments provide a comprehensive molecular picture at unprecedented spatial and temporal resolution of the nonlinear, linear, and fluctuating dynamic phenomena that single nanocrystals undergo during the GLC-EM experiment. We determined atomic structures of 66 temporal structural states, extracted from 15 time trajectories of individual nanocrystals. Large (478 to 698 atoms) and small (<300 atoms) nanocrystals show etching that preserves a stable core, whereas mid-sized (351 to 571 atoms) nanocrystals present dynamics that change the coordination of the core.