Search NASA⌕ Search

SEARCH · Search NASA

Results for “total”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Total-internal reflection elastic metasurfaces: design and application

An acoustic shield for protecting a vibrational sensitive device includes a first unit cell and a second unit cell. The first unit cell includes a first locally resonant unit. The first locally resonant unit controls a first phase gradient and the first unit cell includes a first surface. The second unit cell includes a second surface proximate to the first surface. The second unit cell includes a second locally resonant unit embedded along the second interface. The second locally resonant unit controls a second phase gradient. The first phase gradient is different from the second phase gradient. The first unit cell and the second unit cell comprise a super cell. The acoustic shield is configured such that a vibrational wave from a first side of the super cell to a second side of the super cell is substantially attenuated.

Walsh, Timothy↗

Measurement Of The Total Cross-Section Of Muon Neutrino Charged-Current Coherent Pion Production in NOvA Near Detector

Charged Current (CC) coherent neutrino-nucleus pion production is characterized by small momentum transferred to the nucleus, which is left in its ground state. Despite the relatively large uncertainties on the production cross-section, coherent production of mesons by neutrinos represents an important process, as it can shed light on the structure of the weak current and can also constitute a potential source of background for modern neutrino oscillation experiments and searches for Beyond Standard Model (BSM) physics. This Ph.D. thesis presents a new measurement of CC coherent pion production in the NOvA near detector at the Fermi National Accelerator Laboratory (Fermilab). The analysis is based on the use of both particle identification and kinematic selection criteria based on Convolutional Neural Networks (CNN) to achieve a selection purity of 60%. Given the energy range 1-5 GeV accessible with the available NOvA exposure in the NuMI beam, the results will also be relevant for f uture neutrino experiments like the Deep Underground Neutrino Experiment (DUNE).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Environmental exposure to industrial air pollution is associated with decreased male fertility

Objective: To understand how chronic exposure to industrial air pollution is associated with male fertility through semen parameters. Design: Retrospective cohort study. Subjects: Men in the Subfertility, Health and Assisted Reproduction cohort who underwent a semen analysis 2005-2017 with ≥1 measured semen parameter (N=21,563). Intervention(s): Residential histories for each man were constructed using locations from administrative records linked through the Utah Population Database. Industrial facilities with air emissions of nine endocrine disrupting compound chemical classes were identified from the Environmental Protection Agency Risk-Screening Environmental Indicators microdata. Chemical levels were linked with residential histories for the 5 years prior to each semen analysis. Main Outcome Measures: Semen analyses were classified as azoospermic or oligozoospermic (< 15 M/mL) using World Health Organization cutoffs for concentration. Bulk semen parameters such as concentration, total count, ejaculate volume, total motility, total motile count, and total progressive motile count were also measured. Multivariable regression models with robust standard errors were used to associate exposure quartiles for each of the nine chemical classes with each semen parameter, adjusting for age, race, and ethnicity, as well as neighborhood socioeconomic disadvantage. Results: After adjustment for demographic covariates, several chemical classes were associated with azoospermia and decreased total motility and volume. For exposure in the 4th relative to 1st quartile, significant associations were observed for acrylonitrile (β total motility = -0.87 pp), aromatic hydrocarbons (odds ratio [OR]azoospermia = 1.53; β volume = -0.14 mL), dioxins (OR azoospermia = 1.31; β volume = -0.09 mL; β total motility = -2.65 pp), heavy metals (β total motility = -2.78pp), organic solvents (OR azoospermia = 1.75; β volume = -0.10 mL), organochlorines (OR azoospermia = 2.09; β volume = -0.12 mL), phthalates (OR azoospermia = 1.44; β volume = -0.09 mL; β total motility = -1.21 pp), and silver particles (OR azoospermia = 1.64; β volume = -0.11 mL). All semen parameters significantly decreased with increasing socioeconomic disadvantage. Men who lived in the most disadvantaged areas had concentration, volume, and total motility of 6.70 M/mL, 0.13 mL, and 1.79 pp lower, respectively. Count, motile count, and total progressive motile count all decreased by 30–34 M.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Characterization of Infrequent Samples from The Concentration, Storage, And Transfer Facility: Leak Detection Box (LDB) Drain Cell Sample: February 26, 2023, Sample

Savannah River Mission Completion Engineering (SRMC-E) requested that the Savannah River National Laboratory (SRNL) analyze the Concentration, Storage, and Transfer Facility (CSTF) samples from the following Tank Farm areas: the sump encasement, catch tank, drain cell, and waste tank annulus. In general, these CSTF samples will be analyzed on an infrequent basis and analyses will include detection for total beta/gamma activities, total alpha activity, free hydroxide, and pH measurements. This report presents characterization results for the leak detection box (LDB) February 26, 2023, drain cell sample. The sample was clear and colorless with no visible particulates. The results are measurements for total gamma, total alpha, total beta, free hydroxide, pH, and density. These analyses were performed in triplicate. A summary of the average analytical results for the LDB sample includes the following. The directly measured pH for the LDB February 26, 2023 "as-received" drain cell sample range was 7.12-7.16, and the free hydroxide concentration was <0.02 M. The density of the "as-received" drain cell sample determined at 25 °C was 1.02±0.00 g/mL. The total alpha activity for the LDB February 26, 2023, sample is reported as a less than value (Upper Limit) because of possible spectral interferences. Thus, the total alpha activity averaged <3.52E+02 dpm/mL. This value is less than 4.83E+03 dpm/mL, which is the procedural limit for non-waste determination. The total beta activity in the LDB February 26, 2023, drain cell sample is above the instrument detection limits and average 9.76E+03±5.94E+02 dpm/mL. The total beta activity in the LDB February 26, 2023, drain cell sample is above he instrument detection limits and averaged 7.76E+03±5.94E+02 dpm/mL. The average measured cesium-137 activity (dominant beta emitter) in the LDB February 26, 2023, drain cell sample is 7.76E+03±2.35E+02 dpm/mL. The corresponding Ba-137m (dominant gamma emitter) activity, calculated as 94.6% of the Cs-137 values, is 7.34E+03±2.23E+02 dpm/mL. The total empirical activity of the beta and gamma emitting (represented by the sum of total beta and Ba-137m activities) averaged 1.71E+04±8.18E+02 dpm/mL. This value is less than 8.69E+05 dpm/mL, which is the procedural limit for non-waste determination.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Globally Gridded Groundwater Extraction Volumes and Costs under Six Depletion and Ponded Depth Targets

This repository contains simulated outputs from superwell – a hydro-economic tool for long-term assessment of groundwater cost and supply – providing globally gridded groundwater extractable volumes and associated unit costs ($/km³) for accessible groundwater production, based on a variety of user-defined depletion and ponded depth scenarios. Key model documentation: Niazi, H., Ferencz, S. B., Graham, N. T., Yoon, J., Wild, T. B., Hejazi, M., Watson, D. J., & Vernon, C. R. (2025). Long-term hydro-economic analysis tool for evaluating global groundwater cost and supply: Superwell v1.1. Geoscientific Model Development, 18(5), 1737-1767. https://doi.org/10.5194/gmd-18-1737-2025 Find the source code of the superwell model on GitHub: https://github.com/JGCRI/superwell Repository Overview Main output: superwell_outputs.7z contains 6 files (4.5 GB) named as superwell_py_deep_all_0.*PD_0.*DL.csv. These files present superwell outputs of global groundwater extraction volumes and cost estimates on a 0.5° scale for six scenarios with different Ponded Depth (PD; 0.3 and 0.6 m) and Depletion Limit (DL; 5%, 25%, and 40% of available volume) targets over the entire pumping lifetime of a grid cell superwell_py_deep_all_0.3PD_0.25DL_sample_100.csv contains superwell outputs for 100 data points sampled to match the global inputs' distribution superwell_py_deep_all_0.3PD_0.25DL_Grid_72548.csv contains superwell output for a single grid cell concept_v5.png provides an overview of the superwell workflow Outputs Description year_number: year of pumping depletion_limit: set depletion limit (DL) as a volume fraction of total available groundwater Mappings: continent, country, gcam_basin_id, Basin_long_name, grid_id: geographic identifiers and basin information Inputs: grid_area (km²): area of the grid cell whyclass: hydrogeological classification of the aquifer permeability (m/day), porosity (%), total_thickness (m), depth_to_water (m): aquifer properties. The geo-processed input data has been published separately: https://doi.org/10.57931/2307831 Model outputs: orig_aqfr_sat_thickness (m), aqfr_sat_thickness (m): original and remaining/instantaneous saturated thickness of the aquifer hydraulic_conductivity (m/day), transmissivity (m²/day): hydraulic properties of the aquifer radius_of_influence (m), areal_extent (km²): well radius and area of influence from the center of the well number_of_wells (-): number of wells in a grid cell determined by a ratio of well area and grid area max_drawdown (m), drawdown (m), drawdown_interference (m): well and aquifer drawdown during extraction total_head (m): total lift for the groundwater (depth to water plus drawdown) total_well_length (m): total depth of wells drilled well_yield (m³/day): pumping rate or well yield power (kW), energy (kWh): power and energy required for pumping groundwater Volume Outputs: volume_produced_perwell (m³), cumulative_vol_produced_perwell (m³): production volume metrics per well volume_produced_allwells (m³), cumulative_vol_produced_allwells (m³): aggregate extraction volumes for all wells in a grid cell available_volume (m³): available groundwater in storage for the grid cell as determined by aquifer properties depleted_vol_fraction: fraction of total volume pumped over available volumes in a grid cell (same as depletion limit) Cost Outputs: well_installation_cost ($): well installation cost based on the hydrogeological complexity of the aquifer annual_capital_cost, maintenance_cost, nonenergy_cost ($): nonenergy costs energy_cost_rate ($/kWh): electricity rate energy_cost ($): energy cost of pumping groundwater total_cost_perwell ($), total_cost_allwells ($): total annual energy and non-energy cost for each and all wells in a grid cell a unit_cost ($/m³), unit_cost_per_km3 ($/km³), unit_cost_per_acreft ($/acre-ft): total cost of pumping a unit of groundwater, indicated for different spatial units Key Resources Model documentation: Niazi, H., Ferencz, S., Graham, N., Yoon, J., Wild, T., Hejazi, M., Watson, D., & Vernon, C. (2024; In-prep). Long-term Hydro-economic Assessment Tool for Evaluating Global Groundwater Cost and Supply: Superwell v1. Geoscientific Model Development. Input data: Niazi, H., Watson, D., Hejazi, M., Yonkofski, C., Ferencz, S., Vernon, C., Graham, N., Wild, T., & Yoon, J. (2024). Global Geo-processed Data of Aquifer Properties by 0.5° Grid, Country and Water Basins. MSD-LIVE Data repository. https://doi.org/10.57931/2307831 superwell source code: https://github.com/JGCRI/superwell Cite as Niazi, H., Ferencz, S., Yoon, J., Graham, N., Wild, T., Hejazi, M., Watson, D., & Vernon, C. (2024). Globally Gridded Groundwater Extraction Volumes and Costs under Six Depletion and Ponded Depth Targets. MSD-LIVE Data repository. https://doi.org/10.57931/2307832 Contact Reach out to Hassan Niazi or Stephen Ferencz or open an issue in the superwell repository for questions or suggestions.

Earth Systems↗

Process Interactions Can Change Process Ranking in a Coupled Complex System Under Process Model and Parametric Uncertainty

For a complex hydrologic system with multiple processes and process interactions, global sensitivity analysis is often used to identify important or influential parameters for model development and improvement. The identification is complicated by process model uncertainty, when a system process can be represented by multiple process models. This study develops a new total-effect process sensitivity index to identify influential processes under model uncertainty. This is done by extending Sobol's total-effect parameter sensitivity index for one system model to total-effect process sensitivity index for multiple system models to account for uncertainty in process models and model parameters. The total-effect process sensitivity index includes not only the first-order process sensitivity index for measuring the importance of individual processes but also higher-order indices that account for process interactions. The total-effect process sensitivity index can identify an influential process that itself and its interactions with other processes influence a model output. Here, the total-effect process sensitivity index is applied to two numerical examples: (a) Sobol's G*-functions with analytical solutions of first-order and total-effect process sensitivity indices, and (b) groundwater flow models with interactions between recharge, geology, and snowmelt processes. The second evaluation shows that, due to second-order and higher-order process interactions, the first-order and total-effect process sensitivity indices give different process ranking. It is thus necessary to estimate both first-order and total-effect process sensitivity indices to appreciate the difference between the first-order impact of a process alone and the overall total-effect impact of the process itself and its interactions with other processes on a model output.

54 ENVIRONMENTAL SCIENCES↗

Second Target Station (STS) Project: Analysis of Bunker Shielding–Preliminary Design

At the Department of Energy’s Oak Ridge National Laboratory, the Second Target Station (STS) beamline sources for preliminary design have been used to perform a shielding analysis of the bunker. The simulations in this report used the ST11 beamline source, primarily the ST11 neutron source, because that source provides conservative prompt total dose rate estimates for all beamlines. Prompt total dose rates (i.e., neutron plus photon dose rates when the beam is on) were calculated on top of the bunker roof, outside the bunker wall, and in the basement below the bunker and instrument floor. Design changes were made to ensure the prompt total dose rate in these areas does not exceed 0.25 mrem/h. This report documents the required shielding thicknesses to meet this dose rate limit. There is one exception to this: for a combination of open and closed beamlines, the prompt total dose rate outside the bunker across from the closed beamline, where there is less shielding due to the lack of beamline shielding, slightly exceeds 0.25 mrem/h. A future analysis will document the shielding modifications required to reduce the calculated prompt total dose rates for this configuration to less than 0.25 mrem/h once more details regarding the STS high density concrete density and composition are known. Finally, prompt total dose rates inside the bunker were simulated. The results of this simulation show that the majority of prompt total dose rate in the bunker is due to neutrons, and a few percent of the total is caused by secondary photons created by the neutrons. The contribution to prompt total dose rate inside the bunker by the primary photons that enter each beamline from the target/moderator area is at least two orders of magnitude less than the neutron contribution. This means prompt total dose rate contributions due to primary photons inside and outside the bunker can be neglected.

42 ENGINEERING↗

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗