Search NASA⌕ Search

SEARCH · Search NASA

Results for “total internal reflection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The Clouds and the Earth's Radiant Energy System (CERES) Sensors and Preflight Calibration Plans

The Clouds and the Earth's Radiant Energy System (CERES) spacecraft sensors are designed to measure broadband earth-reflected solar shortwave (0.3-5 microns) and earth-emitted longwave (5- > 100 microns) radiances at the top of the atmosphere as part of the Mission to Planet Earth program. The scanning thermistor bolometer sensors respond to radiances in the broadband shortwave (0.3-5 microns) and total-wave (0.3- > 100 microns) spectral regions, as well as to radiances in the narrowband water vapor window (8-12 microns) region. 'ne sensors are designed to operate for a minimum of 5 years aboard the NASA Tropical Rainfall Measuring Mission and Earth Observing System AM-1 spacecraft platforms that are scheduled for launches in 1997 and 1998, respectively. The flight sensors and the in-flight calibration systems will be calibrated in a vacuum ground facility using reference radiance sources, tied to the international temperature scale of 1990. The calibrations will be used to derive sensor gains, offsets, spectral responses, and point spread functions within and outside of the field of view. The shortwave, total-wave, and window ground calibration accuracy requirements (1 sigma) are +/-0.8, +/-0.6, and +/-0.3 W /sq m/sr, respectively, while the corresponding measurement precisions are +/-O.5% and +/-1.0% for the broadband longwave and shortwave radiances, respectively. The CERES sensors, in-flight calibration systems, and ground calibration instrumentation are described along with outlines of the preflight and in-flight calibration approaches.

Lee, Robert B., III↗

ANALYTICAL MODELS OF EXOPLANETARY ATMOSPHERES. II. RADIATIVE TRANSFER VIA THE TWO-STREAM APPROXIMATION

We present a comprehensive analytical study of radiative transfer using the method of moments and include the effects of non-isotropic scattering in the coherent limit. Within this unified formalism, we derive the governing equations and solutions describing two-stream radiative transfer (which approximates the passage of radiation as a pair of outgoing and incoming fluxes), flux-limited diffusion (which describes radiative transfer in the deep interior), and solutions for the temperature-pressure profiles. Generally, the problem is mathematically underdetermined unless a set of closures (Eddington coefficients) is specified. We demonstrate that the hemispheric (or hemi-isotropic) closure naturally derives from the radiative transfer equation if energy conservation is obeyed, while the Eddington closure produces spurious enhancements of both reflected light and thermal emission. We concoct recipes for implementing two-stream radiative transfer in stand-alone numerical calculations and general circulation models. We use our two-stream solutions to construct toy models of the runaway greenhouse effect. We present a new solution for temperature-pressure profiles with a non-constant optical opacity and elucidate the effects of non-isotropic scattering in the optical and infrared. We derive generalized expressions for the spherical and Bond albedos and the photon deposition depth. We demonstrate that the value of the optical depth corresponding to the photosphere is not always 2/3 (Milne's solution) and depends on a combination of stellar irradiation, internal heat, and the properties of scattering in both the optical and infrared. Finally, we derive generalized expressions for the total, net, outgoing, and incoming fluxes in the convective regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Molybdenum Sleeve Experiments in Fully-Reflected Water-Moderated Triangular-Pitched U(6.90)O 2 Fuel Rod Lattices (1.55 cm Pitch)

The US Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories. The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water-moderated and -reflected array of aluminum-clad U(6.90 %)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMP-THERM-096, LEUCOMP-THERM-097, LEU-COMP-THERM-101, and LEU-COMP-THERM-102. The purpose of these experiments was to measure the effects of molybdenum in nearly-critical systems. The molybdenum was introduced into the fuel arrays as tubular sleeves that surrounded some of the fuel rods in the fuel arrays measured. Four hundred molybdenum tubes nominally 12.7 mm outside diameter, 498 mm long, with 0.762 mm wall thickness were provided for the experiments by the Institut de Radioprotection et de Sûreté Nucléaire (IRSN). Small polyethylene adapters at each end of the tubes were used to center each tube on a fuel rod in the assembly. The critical experiments were done using a set of triangular-pitched grid plates fabricated for these experiments. The grid plate set accommodated a fuel array of a total of 1261 fuel rod positions on a pitch of 0.610 in (1.5494 cm) in a series of 20 hexagonal rings surrounding the central fuel rod. The fuel used in these experiments was fabricated using unirradiated 6.90 % enriched UO 2 fuel pellets from fuel elements designed to be used in the internal nuclear superheater section of the Pathfinder boiling water reactor operated in South Dakota by the Northern States Power Company in the 1960s. The fuel elements were obtained from The Pennsylvania State University where they had been stored for many years. The fuel pellets in those fuel elements were removed from the original Incoloy cladding and reclad in 3003 aluminum tubes and end caps for use in the experiments reported here. The five critical experiments in this series were performed in August through December 2022, in the Sandia Critical Experiments (SCX) at the Sandia Pulsed Reactor Facility. Case 1 had no molybdenum sleeves, Case 2 had 208 molybdenum sleeves clustered at the center of the array, Case 3 had 397 molybdenum sleeves clustered at the center of the array, Case 4 had 175 molybdenum sleeves in the central position and in five alternating hexagonal rings, and Case 5 had 331 molybdenum sleeves in the central position and in seven alternating hexagonal rings. All five critical experiments are judged to be acceptable as benchmark experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simultaneous probing of bulk liquid phase and catalytic gas-liquid-solid interface under working conditions using attenuated total reflection infrared spectroscopy

Design and performance of a reactor set-up for attenuated total reflection infrared (ATR-IR) spectroscopy suitable for simultaneous reaction monitoring of bulk liquid and catalytic solid-liquid-gas interfaces under working conditions are presented. As advancement of in situ spectroscopy an operando methodology for gas-liquid-solid reaction monitoring was developed that simultaneously combines catalytic activity and molecular level detection at the catalytically active site of the same sample. Semi-batch reactor conditions are achieved with the analytical set-up by implementing the ATR-IR flow-through cell in a recycle reactor system and integrating a specifically designed gas feeding system coupled with a bubble trap. By the use of only one spectrometer the design of the new ATR-IR reactor cell allows for simultaneous detection of the bulk liquid and the catalytic interface during the working reaction. Holding two internal reflection elements (IRE) the sample compartments of the horizontally movable cell are consecutively flushed with reaction solution and pneumatically actuated, rapid switching of the cell (<1 s) enables to quasi simultaneously follow the heterogeneously catalysed reaction at the catalytic interface on a catalyst-coated IRE and in the bulk liquid on a blank IRE. For a complex heterogeneous reaction, the asymmetric hydrogenation of 2,2,2-trifluoroacetophenone on chirally modified Pt catalyst the elucidation of catalytic activity/enantioselectivity coupled with simultaneous monitoring of the catalytic solid-liquid-gas interface is shown. Both catalytic activity and enantioselectivity are strongly dependent on the experimental conditions. The opportunity to gain improved understanding by coupling measurements of catalytic performance and spectroscopic detection is presented. In addition, the applicability of modulation excitation spectroscopy and phase-sensitive detection are demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical Properties of Nanosatellite Hardware

Over the last decade, a number of very small satellites have been launched into space. These have been called nanosatellites (generally of a weight between 1 and 10 kg) or picosatellites (weight <1 kg). This also includes CubeSats, which are based on 10-cm cube units. With the addition of the Japanese Experiment Module (JEM) Small Satellite Orbital Deployer (J-SSOD) to the International Space Station (ISS), CubeSats are easily cycled through the JEM airlock and deployed into space (fig. 1). The number of CubeSats launched since 2003 was approaching 100 at the time of publication, and the authors expect this trend in research to continue, particularly for high school and college flight experiments. Because these spacecraft are so small, there is usually no allowance for shielding or active heating or cooling of the avionics and other hardware. Parts that are usually ignored in the thermal analysis of larger spacecraft may contribute significantly to the heat load of a tiny satellite. In addition, many small satellites have commercial-off-the-shelf (COTS) components. To reduce costs, many providers of COTS components do not include the optical and physical parameters necessary for accurate thermal analysis. Marshall Space Flight Center participated in the development and analysis of the Space Missile Defense Command-Operational Nanosatellite Effect (SMDC-ONE) and the Edison Demonstration of Smallsat Networks (EDSN) nanosatellites. These optical property measurements are documented here in hopes that they may benefit future nanosatellite and picosatellite programs and aid thermal analysis to ensure project goals are met, with the understanding that material properties may vary by vendor, batch, manufacturing process, and preflight handling. Where possible, complementary data are provided from ground simulations of the space environment and flight experiments, such as the Materials on International Space Station Experiment (MISSE) series. NASA gives no recommendation, endorsement, or preference, either expressed or implied, concerning materials and vendors used. Solar absorptance was calculated from spectral reflectance measurements made from 250 to 2,800 nm with an AZ Technology Laboratory Portable Spectroreflectometer (LPSR) model 300. ASTM E-903 was the test method used under normal laboratory conditions, and ASTM E-490 was the solar spectral irradiance data used to calculate solar absorptance. Most of the samples were flat, but stray light was minimized as much as possible with either a blackbody or black cloth as sample background. The LPSR has repeatability of approximately +/-1%, where solar absorptance is given as range, that is, from actual measurements taken across the sample. Infrared emittance measurements were made with an AZ Technology TEMP 2000A infrared reflectometer. This instrument measures the total hemispheric reflectance averaged over 3-35 micrometer wavelengths. ASTM E-408 was the test method used under normal laboratory conditions. 3 Stray light was minimized as much as possible. The TEMP 2000A has repeatability of approximately +/-0.5%, where infrared emittance is given as a range, that is, from actual measurements taken across the sample.

Finckenor, M. M.↗

Modeling the effect of reflection from metallic walls on spectroscopic measurements

A modification of JET is presently being prepared to bring operational experience with ITER-like first wall (Be) and divertor (W) materials, geometry and plasma parameters. Reflectivity measurements of JET sample tiles have been performed and the data are used within a simplified model of the JET and ITER vessels to predict additional contributions to quantitative spectroscopic measurements. The most general method to characterize reflectivity is the bidirectional reflection distribution function (BRDF). For extended sources however, such as bremsstrahlung and edge emission of fuel and intrinsic impurities, the results obtained in the modeling are almost as accurate if the total reflectivity with ideal Lambertian angular dependence is used. This is in contrast to the experience in other communities, such as optical design, lighting design, or rendering who deal mostly with pointlike light sources. This result is so far based on a very limited set of measurements and will be reassessed when more detailed BRDF measurements of JET tiles have been made. If it is true it offers the possibility of in situ monitoring of the reflectivity of selected parts of the wall during exposure to plasma operation, while remeasurement of the BRDF is performed during interventions. For a closed vessel structure such as ITER, it is important to consider multiple reflections. This makes it more important to represent the whole of the vessel reasonably accurately in the model, which on the other hand is easier to achieve than for the more complex internal structure of JET. In both cases the dominant contribution is from the first reflection, and a detailed model of the areas intersected by lines of sight of diagnostic interest is required.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extreme Tele-Echocardiography: Methodology for Remote Guidance of In-Flight Echocardiography Aboard the International Space Station

Methods: In the year before launch of an ISS mission, potential astronaut echocardiographic operators participate in 5 sessions to train for echo acquisitions that occur roughly monthly during the mission, including one exercise echocardiogram. The focus of training is familiarity with the study protocol and remote guidance procedures. On-orbit, real-time guidance of in-flight acquisitions is provided by a sonographer in the Telescience Center of Mission Control. Physician investigators with remote access are able to relay comments on image quality to the sonographer. Live video feed is relayed from the ISS to the ground via the Tracking and Data Relay Satellite System with a 2- second transmission delay. The expert sonographer uses these images, along with twoway audio, to provide instructions and feedback. Images are stored in non-compressed DICOM format for asynchronous relay to the ground for subsequent off-line analysis. Results: Since June, 2009, a total of 27 resting echocardiograms and 5 exercise studies have been performed during flight. Average acquisition time has been 45 minutes, reflecting 26,000 km of ISS travel per study. Image quality has been adequate in all studies, and remote guidance has proven imperative for fine-tuning imaging and prioritizing views when communication outages limit the study duration. Typical resting studies have included 27 video loops and 30 still-frame images requiring 750 MB of storage. Conclusions: Despite limited crew training, remote guidance allows research-quality echocardiography to be performed by non-experts aboard the ISS. Analysis is underway and additional subjects are being recruited to define the impact of microgravity on cardiac structure and systolic and diastolic function.

Martin, David S.↗

Contamination Observed on the Passive Optical Sample Assembly (POSA)-1 Experiment

The Passive Optical Sample Assembly-1 (POSA-1), part of the Mir Environmental Effects Payload (MEEP), was designed to study the combined effects of contamination, atomic oxygen, ultraviolet radiation, vacuum, thermal cycling, and other constituents of the space environment on spacecraft materials. The MEEP program is a Phase 1 International Space Station Risk Mitigation Experiment. The payload was attached by EVA to the exterior of the Mir docking module during the Space Shuttle mission STS-76. It was removed during STS-86 after exposure to the Mir environment for 18 months. POSA-1 consists of nearly 400 samples of thermal control paints, chemical conversion coatings, mirrors, optics, and other candidate materials for International Space Station Alpha (ISSA). POSA-1 also flew state-of-the-art materials, such as electrically conductive thermal control coatings developed under contract by IITRI and AZ Technology, and passive instruments for monitoring the atomic oxygen and ultraviolet radiation dose to the experiment. Contamination was detected on the POSA-1 experiment. On the side facing space (-Z(sub B) direction using the Mir coordinate system), visible contamination was observed. The contamination was uniform as would occur from a slow photodeposition process. A very definite film was deposited on the optical samples. The deposition appears to have directionality with definite shadowing effects. On the side facing the main Mr core (+ZB direction using the Mir coordinate system), no visible contamination was noted. Pre- and post-flight characterization of candidate spacecraft materials is discussed, particularly the effect of contamination on total hemispherical spectral reflectance (250 - 2500 nm), infrared emittance, the bi-directional reflectance distribution function (BRDF), and vacuum ultraviolet spectral reflectance. Extensive photography under normal and black light was performed. Results of electron spectroscopy for chemical analysis (ESCA) and Fourier Transform Infrared Analysis (FTIR) on selected samples are also discussed.

Zwiener, James M.↗

Updated design of the CMB polarization experiment satellite LiteBIRD

Recent developments of transition-edge sensors (TESs), based on extensive experience in ground-based experiments, have been making the sensor techniques mature enough for their application on future satellite CMB polarization experiments. LiteBIRD is in the most advanced phase among such future satellites, targeting its launch in Japanese Fiscal Year 2027 (2027FY) with JAXA's H3 rocket. It will accommodate more than 4000 TESs in focal planes of reflective low-frequency and refractive medium-and-high-frequency telescopes in order to detect a signature imprinted on the cosmic microwave background (CMB) by the primordial gravitational waves predicted in cosmic inflation. The total wide frequency coverage between 34GHz and 448GHz enables us to extract such weak spiral polarization patterns through the precise subtraction of our Galaxy's foreground emission by using spectral differences among CMB and foreground signals. Telescopes are cooled down to 5Kelvin for suppressing thermal noise and contain polarization modulators with transmissive half-wave plates at individual apertures for separating sky polarization signals from artificial polarization and for mitigating from instrumental 1/f noise. Passive cooling by using V-grooves supports active cooling with mechanical coolers as well as adiabatic demagnetization refrigerators. Sky observations from the second Sun-Earth Lagrangian point, L2, are planned for three years. An international collaboration between Japan, USA, Canada, and Europe is sharing various roles. In May 2019, the Institute of Space and Astronautical Science (ISAS), JAXA selected LiteBIRD as the strategic large mission No. 2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full potential study of the elastic, electronic, and optical properties of spinels MgIn{sub 2}S{sub 4} and CdIn{sub 2}S{sub 4} under pressure effect

The structural, elastic, electronic, and optical properties of cubic spinel MgIn{sub 2}S{sub 4} and CdIn{sub 2}S{sub 4} compounds have been calculated using a full relativistic version of the full-potential linearized-augmented plane wave with the mixed basis FP/APW+lo method. The exchange and correlation potential is treated by the generalized-gradient approximation (GGA). Moreover, the Engel-Vosko GGA formalism is also applied to optimize the corresponding potential for band structure calculations. The ground state properties, including the lattice constants, the internal parameter, the bulk modulus, and the pressure derivative of the bulk modulus are in reasonable agreement with the available data. Using the total energy-strain technique, we have determined the full set of first-order elastic constants C{sub ij} and their pressure dependence, which have not been calculated or measured yet. The shear modulus, Young's modulus, and Poisson's ratio are calculated for polycrystalline XIn{sub 2}S{sub 4} aggregates. The Debye temperature is estimated from the average sound velocity. Electronic band structures show a direct band gap ({Gamma}-{Gamma}) for MgIn{sub 2}S{sub 4} and an indirect band gap (K-{Gamma}) for CdIn{sub 2}S{sub 4}. The calculated band gaps with EVGGA show a significant improvement over the GGA. The optical constants, including the dielectric function {epsilon}({omega}), the refractive index n({omega}), the reflectivity R({omega}), and the energy loss function L({omega}) were calculated for radiation up to 30 eV. -- Graphical abstract: Calculated total and partial densities of states for MgIn{sub 2}S{sub 4} and CdIn{sub 2}S{sub 4}

36 MATERIALS SCIENCE↗

Influence of Load Profile on Biomechanics of the Squat and Deadlift

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to assist loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to counteract the effect reduced gravity has on the body. Astronauts will exercise on a flywheel based device on the second Orion Exploration Mission (EM2). The effect that the flywheel load profile has on biomechanics is unknown when compared to free weights or a simulated free weight profile. The purpose of this evaluation is to compare the differences in lower body kinematics and kinetics between the flywheel and free weight profile. Test subjects were instrumented with reflective markers for motion capture data collection while exercising on the Device for Aerobic and Resistive Training (DART) prototype developed by TDA Research, Inc. of Wheat Ridge, CO. Exercises performed were either the squat while wearing a harness or deadlift while grasping a T-bar, both of which interfaced with the DART through a rope cable. The DART, a motorized device controlled via software, is capable of producing different load profiles. Profiles include simulated free weights with adjustable eccentric overload capability and flywheel. Test variables included the applied device load and the load profile, both set through the DART software interface. Motion capture data was collected with a 12 camera system (Smart-DX, BTS Bioengineering, Brooklyn, NY). Bilateral ground reaction force data were collected with force plates (P6000, BTS Bioengineering). DART cable force was recorded through an internal load cell. Data was collected from a total of four test subjects. The three repetition maximum was determined for each test subject for both squat and deadlift. High, medium and low loads were determined based on this maximum. The test subject performed five repetitions of each exercise at each load and each test trial was repeated twice. Cadence was controlled during exercising. Biomechanical data were used to drive the models utilizing the OpenSim software platform. Subject specific models were scaled to match the anthropometrics of the test subjects and used to estimate the peak joint angle, joint range of motion, the peak joint moment and the joint moment impulse of the lower extremity joints and the lumbar joint.These are preliminary results because the data analysis is ongoing. There was a lot of inter-subject variability, however, in general, there was a greater peak lumbar flexion angle for the flywheel squat exercise. There was a trend towards a greater range of motion at the hip for the squat exercise with free weight. There was also a greater hip extension, lumbar extension and ankle plantar flexion impulse moment during the squat exercise with free weight. During the deadlift exercise, the peak knee flexion angle and peak knee extension moment were greater when using the free weight profile. For deadlift, the hip extension, lumbar extension and ankle plantar flexion impulse moment tended to be greater with the free weight profile. Overall, the kinematic and kinetic outcomes for the flywheel profile were either statistically the same as free weight profile in many cases, significantly reduced in a few cases, and rarely higher.

Bioengineering↗

Evaluation of Space Power Materials Flown on the Passive Optical Sample Assembly

Evaluating the performance of materials on the exterior of spacecraft is of continuing interest, particularly in anticipation of those applications that will require a long duration in low Earth orbit. The Passive Optical Sample Assembly (POSA) experiment flown on the exterior of Mir as a risk mitigation experiment for the International Space Station was designed to better understand the interaction of materials with the low Earth orbit environment and to better understand the potential contamination threats that may be present in the vicinity of spacecraft. Deterioration in the optical performance of candidate space power materials due to the low Earth orbit environment, the contamination environment, or both, must be evaluated in order to propose measures to mitigate such deterioration. The thirty two samples of space power materials studied here include solar array blanket materials such as polyimide Kapton H and SiO(x) coated polyimide Kapton H, front surface aluminized sapphire, solar dynamic concentrator materials such as silver on spin coated polyimide and aluminum on spin coated polyimide, CV 1144 silicone, and the thermal control paint Z-93-P. The physical and optical properties that were evaluated prior to and after the POSA flight include mass, total, diffuse, and specular reflectance, solar absorptance, and infrared emittance. Additional post flight evaluation included scanning electron microscopy to observe surface features caused by the low Earth orbit environment and the contamination environment, and variable angle spectroscopic ellipsometry to identify contaminant type and thickness. This paper summarizes the results of pre- and post-flight measurements, identifies the mechanisms responsible for optical properties deterioration, and suggests improvements for the durability of materials in future missions.

Jaworske, Donald A.↗

Advanced source apportionment of size-resolved trace elements at multiple sites in London during winter

Here, trace element measurements in PM 10–2.5 , PM 2.5–1.0 and PM 1.0–0.3 aerosol were performed with 2 h time resolution at kerbside, urban background and rural sites during the ClearfLo winter 2012 campaign in London. The environment-dependent variability of emissions was characterized using the Multilinear Engine implementation of the positive matrix factorization model, conducted on data sets comprising all three sites but segregated by size. Combining the sites enabled separation of sources with high temporal covariance but significant spatial variability. Separation of sizes improved source resolution by preventing sources occurring in only a single size fraction from having too small a contribution for the model to resolve. Anchor profiles were retrieved internally by analysing data subsets, and these profiles were used in the analyses of the complete data sets of all sites for enhanced source apportionment. A total of nine different factors were resolved (notable elements in brackets): in PM 10–2.5 , brake wear (Cu, Zr, Sb, Ba), other traffic-related (Fe), resuspended dust (Si, Ca), sea/road salt (Cl), aged sea salt (Na, Mg) and industrial (Cr, Ni); in PM 2.5–1.0 , brake wear, other traffic-related, resuspended dust, sea/road salt, aged sea salt and S-rich (S); and in PM 1.0–0.3 , traffic-related (Fe, Cu, Zr, Sb, Ba), resuspended dust, sea/road salt, aged sea salt, reacted Cl (Cl), S-rich and solid fuel (K, Pb). Human activities enhance the kerb-to-rural concentration gradients of coarse aged sea salt, typically considered to have a natural source, by 1.7–2.2. These site-dependent concentration differences reflect the effect of local resuspension processes in London. The anthropogenically influenced factors traffic (brake wear and other traffic-related processes), dust and sea/road salt provide further kerb-to-rural concentration enhancements by direct source emissions by a factor of 3.5–12.7. The traffic and dust factors are mainly emitted in PM 10–2.5 and show strong diurnal variations with concentrations up to 4 times higher during rush hour than during night-time. Regionally influenced S-rich and solid fuel factors, occurring primarily in PM 1.0–0.3 , have negligible resuspension influences, and concentrations are similar throughout the day and across the regions.

54 ENVIRONMENTAL SCIENCES↗

Total Dissolved Nitrogen and Ammonia Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for total dissolved nitrogen (TDN) and ammonia concentrations for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. TDN was analyzed using a Shimadzu Total Nitrogen Module (TNM-1) combined with the TOC-VCSH analyzer (Shimadzu Corporation, Japan). TNM-1 is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. Ammonia was determined using a Lachat's QuikChem 8500 Series 2 Flow Injection Analysis System (LACHAT Instruments, QuckChem 8500 series 2, Automated Ion Analyzer, Loveland, Colorado). When ammonia in water samples is heated (60 degrees C) with salicylate and hypochlorite in an alkaline phosphate buffer, an emerald green color is produced which is proportional to the ammonia concentration. The color is intensified by the addition of nitroprusside. Ethylenediaminetetraacetic acid (EDTA) is added to the buffer to prevent the interference of metal ions (Ca, Mg, and Fe etc.). Ammonia-N is then determined by LACHAT flow injection and a colorimetric assay at an absorbance wavelength 660 nm. (Reference: LACHAT Instruments: QuickChem Method 90-107-06-3-A, Determination of Ammonia by Flow Injection Analysis (High Throughput, Salicylate Method/DCIC) (Multi Matrix method). Written by Lynn Egan (Application group), February 08, 2011.) All files are labeled by location and variable, and data reported are the mean values upon replicate measurements. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process as detailed in the methods. This data package contains (1) a zip file (tdn_ammonia_data_2015-2025.zip) containing a total of 299 files: 298 data files of ammonia and TDN data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v7_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v7_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the determination of Method Detection Limits (MDLs) for TDN data, which has been updated in 2026-08; and (5) PDF and docx files for the detemination of Method Detection Limits (MDLs) for Ammonia and the Interferences by LACHAT Flow Injection Analysis. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 105 locations containing TDN and Ammonia-N data. Update 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses and Determination of Method Detection Limit for Ammonia and the Interferences by LACHAT Flow Injection Analysis documents, which can be accessed as PDFs or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated total dissolved nitrogen and ammonia data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2022-12-20: Updates were made to both the data files and reporting format specific files. Units were listed incorrectly, but have been fixed to reflect correct units (ug/L). File level metadata (flmd) and data dictionary (dd) files were updated to reflect the updated versions of these files. Available data was added up until 2022-06-01. Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-27. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for TDN were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for TDN data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗

MISR Level 1B1 Local Mode Radiance Data (MIB1LM_V1)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. In addition to the Level 1B1 radiometric product for MISR's Global Mode imagery, there is a separate Level 1B1 product for each high-resolution Local Mode scene. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Horizontal_Resolution_Range=250 km - < 500 km or approximately 2.5 degrees - < 5.0 degrees; Temporal_Resolution=about 15 orbits/day].

NEAR IR IMAGERY↗

MISR Level 1B1 Local Mode Radiance Data (MIB1LM_V2)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. In addition to the Level 1B1 radiometric product for MISR's Global Mode imagery, there is a separate Level 1B1 product for each high-resolution Local Mode scene. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Temporal_Resolution=about 15 orbits/day].

AM-1↗

Berkeley Lab WINDOW

WINDOW features include: - Microsoft Windows TM interface - algorithms for the calculation of total fenestration product U-values and Solar Heat Gain Coefficient consistent with ASHRAE SPC 142, ISO 15099, and the National Fenestration Rating Council - a Condensation Resistance Index in accordance with the NFRC 500 Standard - and integrated database of properties - imports data from other LBNL window analysis software: - Import THERM file into the Frame Library - Import records from IGDB and OPtics5 into the Glass Library for the optical properties of coated and uncoated glazings, laminates, and applied films. Program Capabilities WINDOW 7.2 offers the following features: The ability to analyze products made from any combination of glazing layers, gas layers, frames, spacers, and dividers under any environmental conditions and at any tilt; The ability to model complex glazing systems such as venetian blinds and roller shades. Directly accessible libraries of window system components, (glazing systems, glazing layers, gas fills, frame and divider elements), and environmental conditions; The choice of working in English (IP), or Systeme International (SI) units; The ability to specify the dimensions and thermal properties of each frame element (header, sills, jamb, mullion) in a window; A multi-band (wavelength-by-wavelength) spectral model; A Glass Library which can access spectral data files for many common glazing materials from the Optics5database; A night-sky radiative model; A link with the DOE-2.1E and Energy Plus building energy analysis program. Performance Indices and Other Results For a user-defined fenestration system and user-defined environmental conditions, WINDOW calculates: The U-value, solar heat gain coefficient, shading coefficient, and visible transmittance for the complete window system; The U-value, solar heat gain coefficient, shading coefficient, and visible transmittance for the glazing system (center-of-glass values); The U-values of the frame and divider elements and corresponding edge-of-glass areas (based on generic correlations); The total solar and visible transmittance and reflectances of the glazing system. Color properties, i.e. L*, a*, and b* color coordinates, dominant wavelength, and purity for transmitted and reflected (outdoor) solar radiation; The damage-weighted transmittance of the glazing system between 0.3 an 0.38 microns; The angular dependence of the solar and visible transmittances, solar and visible reflectances, solar absorptance, and solar heat gain coefficient of the glazing system; The percent relative humidity of the inside and outside air for which condensation will occur on the interior and exterior glazing surfaces respectively; The center-of-glass temperature distribution.

Curcija, DraganCharlie↗

Machine Learning Algorithms for Aerosol and Cloud Detection Using CATS on the ISS

Clouds and aerosols are one of the largest uncertainties in understanding and forecasting the Earth’s changing climate system. The type and height of aerosols are important factors in determining the top-of-atmosphere (TOA) radiation budget, either direct reflection of solar radiation back to space and/or absorption of solar radiation. In addition to their impact on the Earth’s climate system, aerosols near the surface from wildfires, man-made pollution events, and dust storms are hazardous to human health. The phase and height of clouds also play a critical role in determining the role of clouds in the Earth’s climate system. Cirrus clouds in the upper troposphere can induce a significant daytime TOA warming effect, while liquid water clouds near the surface cause a large corresponding cooling effect. Lidar measurements provide accurate vertically resolved information about clouds and aerosols, including complex multi-layer scenes where passive sensors are challenged and at night, when passive sensors are unable to measure cloud and aerosol properties. The Cloud-Aerosol Transport System (CATS) is a lidar instrument that operated for 33 months on the International Space Station (ISS) at the 1064 nm wavelength to measure attenuated total backscatter and depolarization ratio. These fundamental measurements are used to derive “vertical feature mask” cloud and aerosol products, including layer top/base heights, layer geometrical thickness, aerosol type, and cloud phase. While space-based lidar systems like CATS provide cloud and aerosol vertical distributions that improve our understanding of the climate system, averaging of the daytime data from these sensors is required, at the expense of spatial resolution, to improve the daytime signal-to noise (SNR) and thus atmospheric layer detection. This presentation shows results from machine learning (ML) techniques that, when applied to CATS data: 1. improve the 1064 nm SNR 2. enable detection of atmospheric features during daytime with a horizontal resolution of 350 m or 5 km (compared to the 60 km required for standard CATS data products) 3. increase the number of atmospheric layers detected in the CATS data. A Convolutional Neural Network (CNN) trained using CATS standard data products also demonstrated the potential for improved cloud-aerosol discrimination, cloud phase, and aerosol typing compared to the operational CATS algorithms for cloud edges and complex near-surface scenes during daytime. The ML tools described in this paper can facilitate the development of smaller, low-cost lidar systems in the future and enable real-time accessibility of lidar data products from future lidar systems for monitoring and forecasting of hazardous events.

John Yorks↗