Effect of Large Scale Transmission Limitations on Renewable Energy Load Matching for Western U.S.: Preprint

Based on the available geographically dispersed data for the Western U.S. (excluding Alaska), we analyze to what extent the geographic diversity of these resources can offset their variability. Without energy storage and assuming unlimited energy flows between regions, wind and PV can meet up to 80% of loads in Western U.S. while less than 10% of the generated power is curtailed. Limiting hourlyenergy flows by the aggregated transmission line carrying capacities decreases the fraction of the load that can be met with wind and PV generation to approximately 70%.

14 SOLAR ENERGY↗

Projecting Future Colorado River Basin Water and Hydropower Operations

Drought, variable renewable energy (VRE) resources (primarily wind and photovoltaic technologies), and power markets can all impact hydropower plant operations. We analyze how these three factors collectively may potentially change the future operation and economics of federal dams and hydropower plants located in the Colorado River Basin (CRB). Federal CRB energy and capacity resources, including 4,200 MW of hydropower capacity, are marketed by Western Area Power Administration (WAPA) and sold through long-term Firm Electric Service (FES) contracts to entities located in 15 western and central States that serve millions of electricity consumers. The parameters of FES contracts allow a wide range of scheduling flexibility for FES customers. The FES customers will adjust the timing of energy delivery according to the changing water, power market, and VRE contribution level to the power grid. We simulate and project water and hydropower operations with two models: 1) reservoir operation and 2) power system operation (production cost) with various temporal granularity. We consider two sets of grid scenarios (one representing today's infrastructure, and one representing higher VRE contributions in 2036) and two sets of water scenarios (drought and normal hydrology). We modeled scenarios to understand the power market-energy price levels and patterns, FES customer scheduling, hydropower economics, WAPA finances and hydropower operation for various hydrologic conditions, and VRE contribution level to the power grid. The detailed modeling framework includes: (1) creating ensembles of CRB hydrologic and hydropower futures, (2) selecting representative futures, (3) simulation of FES customer contracts, (4) simulating western U.S. power grid economic scheduling and dispatch under two VRE contribution levels, utilizing information from modeling steps (1)-(4), (5) assessment of reservoir water and hydropower operation, and (6) comparing scenario operations and economics. Our study team comprising WAPA, and an interdisciplinary team of national labs will gain insight into how WAPA can prepare for and adapt its practices in response to an evolving U.S. power grid.

Colorado River↗

DER Digital Supply Chain Gap Analysis

Solar photovoltaic (PV) cybersecurity is a growing field of research. As deployments of solar PV have increased, cyber risk has also increased. Utility solar PV installations, however, are not required to comply with the North American Electric Reliability Corporation (NERC) Critical Infrastructure Protection (CIP) plan unless they meet a minimum generation threshold of 75 MW. Individual residential-scale solar PV deployments will not meet that generation threshold and are therefore excluded from the NERC CIP requirements. With most solar installations less than 75 MW, solar PV has been deployed with minimal oversight and highly variable cybersecurity maturity. The resources that comprise the digital supply chain can include software, code, data, and other digital components. But as clean energy technologies advance, cybersecurity threats and vulnerabilities continue to evolve and grow in sophistication. Supply chain cybersecurity represents a critical area for ensuring safe operations as the U.S. moves toward a clean energy future.

cybersecurity↗

Control of energy storage to reduce electric power system off-nominal frequency deviations

A hybrid power generation system is formed by the combination of an energy storage system (ESS) and a rotating synchronous power generator (SPG). Energy is stored in or released from the ESS in response to measurements of the at least one angle parameter, selected from rotor, torque, or power angle of the SPG, to provide active frequency damping of electrical power output. The control of ESS energy exchange increases the stabilizing impact of the SPG inertia on the frequency of electricity in an electrical network or power grid. The hybrid power generation system can have an effective equal area criterion for stability limit that is greater than that of the SPG operating without the ESS. The hybrid power generation system can enable the electrical network to have a greater proportion of variable or distributed energy resource (DER) power generation systems without otherwise exceeding stability limits.

Vartanian, Charles K.↗

Observational Assessment of Metocean Conditions in the WFIP3 Region

The WFIP3 project, sponsored by the U.S. Department of Energy, is aimed at improving our understanding of the physics of the atmosphere and ocean that dictate the structure and variability of the wind resource within the MABL. As part of the project, a long-term offshore field campaign will take place along the U.S. East Coast to provide an unprecedented characterization of the MABL in the vicinity of the Massachusetts/Rhode Island wind energy lease areas. The unprecedented observational data set collected in the WFIP3 field campaign will allow intensive numerical modeling development and validation efforts. To inform the field campaign design and the preliminary studies associated with it, here we perform a characterization of the MABL and ocean conditions by leveraging available observations in the region.

lidars↗

Loads as a Resource: Frequency Responsive Demand

Demand-side frequency control can complement traditional generator controls to maintain the stability of large electric systems in the face of rising uncertainty and variability associated with renewable energy resources. This report presents a hierarchical frequency-based load control strategy that uses a supervisor to flexibly adjust control gains that a population of end-use loads respond to in a decentralized manner to help meet the NERC BAL-003-1 frequency response standard at both the area level and interconnection level. The load model is calibrated and used to model populations of frequency-responsive water heaters in a PowerWorld simulation of the U.S. Western Interconnection (WECC). The proposed design is implemented and demonstrated on physical water heaters in a laboratory setting. A significant fraction of the required frequency response in the WECC could be supplied by electric water heaters alone at penetration levels of less than 15%, while contributing to NERC requirements at the interconnection and area levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operating Reserve Reductions from a Proposed Energy Imbalance Market with Wind and Solar Generation in the Western Interconnection

This paper considers several alternative forms of an energy imbalance market (EIM) proposed in the nonmarket areas of the Western Interconnection. The proposed EIM includes two changes in operating practices that independently reduce variability and increase access to responsive resources: balancing authority cooperation and sub-hourly dispatch. As the penetration of variable generation increaseson the power system, additional interest in coordination would likely occur. Several alternative approaches could be used, but consideration of any form of coordinated unit commitment is beyond the scope of this analysis. This report examines the benefits of several possible EIM implementations--both separately and in concert

14 SOLAR ENERGY↗

Chance-constrained Service Restoration for Distribution Networks with Renewables

Power systems operation is facing great challenges from natural disasters and cyber-attacks. It is critical but also difficult to enhance the reliability and resilience against extreme events. To better response to inevitable outages or blackouts, service restoration in distribution networks is important to minimize the disastrous impacts of catastrophic events. The increasing penetration of distributed energy resources (DERs) provides new opportunities to expedite the restoration process. However, the coordination with conventional distribution system control devices and the uncertainty and variability of intermittent renewable energy resources requires new operation and control strategies for distribution service restoration (DSR). This paper develops an optimal bottom-up DSR strategy by coordinating DERs with voltage regulators and capacitor banks. The chance-constrained (CC) programming approach is used to model the probabilistic output limit of solar radiation and PV generation. The Markov's inequality and Latin hypercube sampling techniques are applied to convert and incorporate the chance constraints into the DSR optimization problem. The CC-DSR problem is formulated as a mixed integer convex programming problem, considering various operational cost functions and bidirectional three-phase unbalanced load flow. Simulation results on the modified IEEE 13-node test feeder system demonstrate the effectiveness and flexibility of the bottom-up DSR strategy.

Chance constrained optimization, Distribution serv↗

Improving Performance of Power Systems with Large-scale Variable Generation Additions

A power system with large-scale renewable resources, like wind and solar generation, creates significant challenges to system control performance and reliability characteristics because of intermittency and uncertainties associated with variable generation. It is important to quantify these uncertainties, and then incorporate this information into decision-making processes and power system operations. This paper presents three approaches to evaluate the flexibility needed from conventional generators and other resources in the presence of variable generation as well as provide this flexibility from a non-traditional resource – wide area energy storage system. These approaches provide operators with much-needed information on the likelihood and magnitude of ramping and capacity problems, and the ability to dispatch available resources in response to such problems.

Makarov, Yuri V.↗

Loads as a Resource: Frequency Responsive Demand

Current power grid operation predominantly relies on scheduling and regulating generation resources to supply loads and balance load changes. Due to the inherent intermittency of renewable energy, more flexible and fast ramping capacity is required to compensate for the uncertainty and variability introduced by renewable energy resources. With the advancement of information technologies, power system end-use loads are becoming more agile and can participate in provision of balancing energy and other grid services. The use of demand response can greatly reduce the required generation reserve in a clean and environmentally friendly way. In this report, a new frequency responsive load (FRL) controller was proposed based on the GFA controller, which can respond to both over and under-frequency events. A supervisory control was introduced to coordinate the autonomous response from FRLs in order to overcome the issues of excessive system response due to high penetration of FRLs. The effectiveness of the proposed FRL controller was demonstrated by large-scale simulation studies on the WECC system. Specifically, the FRLs were deployed in the WECC system at different penetration levels to analyze the performance of the proposed strategy both with and without supervisory level control. While both methods have their own advantages, the case without supervisory control could lead to system-wide instability depending on the size of the contingency and the number of FRLs deployed in the system. In addition, the voltage impacts of this controller on distribution system were also carefully investigated. Finally, a preliminary measurement and verification approach was also developed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Role of Renewable Energy, Storage, and Demand Response in Karnataka's Power Sector Future

Karnataka ranks fourth among Indian states in installed capacity of renewable energy, which accounts for over 50% of its resource mix. The state is positioned to play a leading role in India's energy transition and contribute to meeting national targets for renewable energy thanks, in part, to ambitious state goals to develop Karnataka's abundant zero carbon energy resources and plans to phase out new investments in thermal plants. Power system stakeholders in Karnataka are faced with the challenge of planning a generation portfolio that accounts for the variability of wind and solar resources, meets increasing and shifting electricity demand, and satisfies operational and reliability requirements. The objective of this study is to evaluate least-cost pathways for Karnataka's electric power system through 2050. The capacity expansion model developed for this study identifies power system investment and operational decisions for every year (2020-2050) for all of India, with detailed representation of the state of Karnataka. The study led to five high-level results and provides a framework for recurring planning studies to meet changing system conditions and needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final report for %22High performance computing for advanced national electric power grid modeling and integration of solar generation resources%22, LDRD Project No. 149016.

Design and operation of the electric power grid (EPG) relies heavily on computational models. High-fidelity, full-order models are used to study transient phenomena on only a small part of the network. Reduced-order dynamic and power flow models are used when analysis involving thousands of nodes are required due to the computational demands when simulating large numbers of nodes. The level of complexity of the future EPG will dramatically increase due to large-scale deployment of variable renewable generation, active load and distributed generation resources, adaptive protection and control systems, and price-responsive demand. High-fidelity modeling of this future grid will require significant advances in coupled, multi-scale tools and their use on high performance computing (HPC) platforms. This LDRD report demonstrates SNL's capability to apply HPC resources to these 3 tasks: (1) High-fidelity, large-scale modeling of power system dynamics; (2) Statistical assessment of grid security via Monte-Carlo simulations of cyber attacks; and (3) Development of models to predict variability of solar resources at locations where little or no ground-based measurements are available.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-time dispatch optimization for concentrating solar power with thermal energy storage

Concentrating solar power (CSP) plants present a promising path towards utility-scale renewable energy. The power tower, or central receiver, configuration can achieve higher operating temperatures than other forms of CSP, and, like all forms of CSP, naturally pairs with comparatively inexpensive thermal energy storage, which allows CSP plants to dispatch electricity according to market price incentives and outside the hours of solar resource availability. Currently, CSP plants commonly include a steam Rankine power cycle and several heat exchange components to generate high-pressure steam using stored thermal energy. The efficiency of the steam Rankine cycle depends on the temperature of the plant's operating fluid, and so is a main concern of plant operators. However, the variable nature of the solar resource and the conservatism with which the receiver is operated prevent perfect control over the receiver outlet temperature. Therefore, during periods of solar variability, collection occurs at lower-than-design temperature. To support operator decisions in a real-time setting, we develop a revenue-maximizing non-convex mixed-integer, quadradically-constrained program which determines a dispatch schedule with sub-hourly time fidelity and considers temperature-dependent power cycle efficiency. The exact nonlinear formulation proves intractable for real-time decision support. Here we present exact and inexact techniques to improve problem tractability that include a hybrid nonlinear and linear formulation. Our approach admits solutions within approximately 3% of optimality, on average, within a five-minute time limit, demonstrating its usability for decision support in a real-time setting.

14 SOLAR ENERGY↗

A Comparative Study of Available Water in the Major River Basins of the World

Numerous large river basins of the world have few and irregular observations of the components of the terrestrial hydrological cycle with the exception of stream gauges at a few locations and at the outlet along with sparsely distributed rain gauges. Using observations from satellite sensors and output from global land surface models, it is possible to study these under-observed river basins. With populations greater than a billion people, some of these rivers (e.g., the Ganga-Brahmaputra, the Yangtze, the Nile and the Mekong) are the economic engines of the countries they transect, yet thorough assessment of their flow dynamics and variability in regard to water resource management is still lacking. In this paper, we use soil moisture (0-2m) and surface runoff from the NASA Global Land Data Assimilation System (GLDAS), evapotranspiration, and Normalized Difference Vegetation Index (NDVI) from the Moderate Resolution Imaging Spectroradiometer (MODIS) and rainfall from the Tropical Rainfall Measuring Mission (TRMM) and total water storage anomaly from the Gravity Recovery and Climate Experiment (GRACE) to examine variability of individual water balance components. To this end, understanding the inter-annual and intra-seasonal variability and the spatial variability of the water balance components in the major river basins of the world will help to plan for improved management of water resources for the future.

GLDAS↗

Searching for quantum optimal controls under severe constraints

The success of quantum optimal control for both experimental and theoretical objectives is connected to the topology of the corresponding control landscapes, which are free from local traps if three conditions are met: (1) the quantum system is controllable, (2) the Jacobian of the map from the control field to the evolution operator is of full rank, and (3) there are no constraints on the control field. This paper investigates how the violation of assumption (3) affects gradient searches for globally optimal control fields. The satisfaction of assumptions (1) and (2) ensures that the control landscape lacks fundamental traps, but certain control constraints can still prevent successful optimization of the objective. Using optimal control simulations, we show that the most severe field constraints are those that limit essential control resources, such as the number of control variables, the control duration, and the field strength. Proper management of these resources is an issue of great practical importance for optimization in the laboratory. For each resource, we show that constraints exceeding quantifiable limits can introduce artificial traps to the control landscape and prevent gradient searches from reaching a globally optimal solution. These results demonstrate that careful choice of relevant control parameters helps to eliminate artificial traps and facilitate successful optimization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessing thermal comfort and participation in residential demand flexibility programs

Residential space-conditioning-based demand flexibility (DF) has become an increasingly sought-after method for demand-side load management to enhance grid reliability and facilitate integration of renewable energy generation. However, predicting the effectiveness and flexibility of residential DF resources is challenging due to the variability in household energy use behaviors. Current estimates show that only 50 % of projected savings from DF resources are actualized due to regulatory, technological, and social barriers. From a household perspective, concerns over thermal comfort during space conditioning-based DF events significantly impact participation decisions. Currently, there is a very limited understanding of how thermal comfort during space-conditioning-based DF events in real-world settings impacts household energy use behaviors and, consequently, the success of DF programs in achieving targeted savings. This paper proposes a method to comprehensively assess the thermal comfort implications of DF strategies and presents results of their impacts on DF event participation decisions and demand savings. Here, the proposed method was applied to a heat pump DF field study in Cordova, Alaska. The study’s key findings are: 1) DF event setpoint offsets that maintain indoor operative temperatures between 18 to 22 °C (65 to 71°F) may be preferred in Cordova, Alaska; 2) Household-level thermal comfort is more sensitive to the duration of the DF event than to the degree of temperature offset from baseline conditions; 3) The delayed impact of changes in indoor operative temperature in response to setpoint offsets, both during and after a DF event, influences occupants’ thermal comfort perceptions and willingness to persistently participate in events. The findings from application of the proposed method can help inform future larger-scale occupant-centric DF programs as it can capture information not readily available through utility and device-level energy use data. Thus, it can supplement these sources and help program administrators develop occupant-centric DF strategies, enabling more accurate predictions of participation rates and savings estimates for space-conditioning-based DF programs.

Demand side management↗

An Evaluation of Electricity Net Load Profiles and the Baseload Generation Concept

This paper investigates the amount of baseload generation that would be displaced due to renewable resources being implemented to meet state renewable portfolio standards (RPS) in the following regions: the Midwest Independent System Operator (MISO), the PJM regional transmission organization (RTO), the Electric Reliability Council of Texas (ERCOT), and the California ISO (CAISO). Modeling of these regions was done in Promod, a security constrained economic dispatch (SCED) model, for the years 2016-2030, to compare scenarios with and without the two primary intermittent renewable resources (solar and wind) attributable to the RPS regulations implemented in each state. In addition, a new statistical approach was developed for evaluating the variability in net load shapes caused by these two intermittent resources. The load variability index (LVI) was developed to apply to the hourly net load profiles for each day as a means of comparing variability in net loads.

14 SOLAR ENERGY↗

Repurposing Fossil-Fueled Assets For Energy Storage

The annual retirement of U.S. coal-fired electricity generation units (CF-EGU) is at an all-time high and is expected to continue. This loss of reliable baseload generation, combined with predicted growth of variable renewable energy (VRE) generation, is expected to stress grid reliability as the number of load-following resources drops below the experienced load variability. Many regions are already experiencing challenges, and fossil retirement-related warnings by the North American Electric Reliability Corp. are becoming more dire. All CF-EGU retirements pose significant challenges to asset owners, local workforces, and their communities. Repurposing a retiring CF-EGU as a long-duration energy storage plant can address these challenges and offer a suite of additional benefits to asset owners, the grid, and society. This project performed a techno-economic evaluation and assessment of repurposing a Duke Energy fossil-fueled asset (in particular, a coal plant) into an energy storage system by integrating the retiring asset with a Malta long duration Pumped Heat Energy Storage (PHES) system. The project validated the technoeconomic benefits of repurposing retiring coal plants into long-duration energy storage using Malta’s PHES. Key findings for this project are summarized below: (1) Technical: (a) Retiring coal plants (and other steam turbine fossil generation) can be repurposed to enable the clean energy transition using Malta’s technology. (b) For older retiring coal plants, repurposing the site and electrical interconnection for a standalone PHES plant is the most economically favorable option. (c) For newer coal plants where there is also a local peaking capacity need, repowering the steam cycle into a hybrid integration with PHES is attractive. (d) A process was developed to assist fossil generation owners in choosing the best path for each plant’s circumstances. (2) Economic (a) Communities facing economic challenges caused by the retirement of fossil generation would benefit from repurposing the plant as long-duration energy storage using Malta’s PHES. (b) On a $/MW basis, repowering retiring coal units into Malta PHES plants can maintain the same number and types of jobs and economic activity. (c) For a 70% carbon reduction scenario, a 10-hour Malta PHES plant is more economic for the asset owner than similar-power 4-hour batteries. This project showed that repurposing a retiring coal unit into thermal energy storage, by integrating it with a Malta PHES system, makes techno-economic sense. At least two integration options are available, with the optimal solution depending on the coal plant and its location. Repurposing retiring coal plant into energy storage results in economic benefits for the plant owner and local communities.