Search NASA⌕ Search

SEARCH · Search NASA

Results for “water heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Extraction of Oil From Camelina Seeds Using Liquefied Dimethyl Ether

With a changing climate and a push for net-zero carbon emissions, sustainable aviation fuel (SAF) is gaining interest worldwide. Due to its compatibility with current infrastructure and potential to reduce emissions by up to 94%, SAF has been identified as the best near-term opportunity to decrease carbon emissions in the aviation industry. SAF can be produced from various renewable feedstocks, with Camelina sativa (L.) seeds standing out due to their high oil content. Conventionally, the oil is extracted using hydrothermal liquefaction (HTL), which involves the pressurized heating of water and biomass up to 400°C, making it incredibly energy-intensive. Conversely, liquefied dimethyl ether (DME) extraction operates at room temperature and is capable of near 100% solvent recycling. In this work, we propose the use of DME extraction as a substitute for HTL, hypothesizing that it can overcome the challenges of current oil extraction methods while maintaining the same oil yields.

09 - BIOMASS FUELS↗

Process Design and Techno-Economic Analysis of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Biomass

This work describes the process design and techno-economic analysis (TEA) of the modular SPOC power plant for biomass firing and coal-biomass co-firing. Two Rankine cycles were considered: a supercritical steam cycle (242 bar, 593°C, 593°C) with 550 MWe net output and a subcritical cycle (166 bar, 566°C, 566°C) with 200 MWe net output. For both cases, 95% carbon capture was modeled, and hybrid poplar biomass was chosen to generate carbon-negative power. In addition, the supercritical 500 MWe case included a 25% biomass co-firing (carbon neutral) case. For both cycles, a 100% Powder River Basin coal firing case was used for comparison purposes. In the SPOC process, oxygen is produced via a cryogenic air separation unit (ASU) and the heat generated from the compression of air is integrated into the steam cycle and utilized for boiler feed water pre-heating. Unique to the SPOC process, the boilers are pressurized and arranged in a series-parallel configuration, with minimized flue gas recirculation. The flue gas is cooled and scrubbed in the direct-contact cooler (DCC) column, and the moisture in the flue gas is condensed, leaving the bottom of the DCC at a sufficiently high temperature such that it can be used for boiler feed water pre-heating, improving plant thermal efficiency. Following drying and purification, CO2 in the flue gas is at the purity required for storage or utilization. The performance data were obtained from process modelling via Aspen Plus®. The stream data from Aspen Plus® were used as an input for the AACE Class 5 cost study. Ultimately, the capital costs, Levelized Cost of Electricity (LCOE), and cost of CO2 captured and avoided were obtained. The HHV efficiency of the carbon negative 550 MWe supercritical SPOC case (34.8%) was clearly above those reported by NETL for the BECCS baseline cases of supercritical pulverized coal with capture (B12B, 31.5%) and the 49% biomass co-firing case with capture (PA3, 29.2%). The HHV efficiency of the carbon-negative subcritical plant is also higher than the subcritical baseline PC plant with capture (case B11B.95) presented by NETL (32% vs 29.7%). The LCOE for the SPOC 100% biomass case was similar to the LCOE for the BECCS 49% biomass with carbon capture case ($147/MWh), and the SPOC carbon neutral case LCOE was lower ($110/MWh) than the cost for the NETL baseline SC coal firing case with 90% carbon capture ($114/MWh).

Magalhaes, Duarte↗

Catalyzing the Mass Adoption of High Efficiency Technologies in the Multifamily Housing Market

ICAST’s objective was to catalyze the adoption of very-high-efficiency (VHE) heat pump HVAC (mini-splits) and water heaters (HPWH) in multifamily (MF), especially affordable housing (MFAH). Nationally, the market penetration of ENERGY STAR-certified ASHPs is estimated at 43%, and for HPWHs it’s 3% (ENERGY STAR, 2022). Note that mini-splits are a much more practical choice for MF units than ducted systems and their adoption is only a portion of the number provided above, but isolating the market penetration data for mini-split systems is difficult. Both the heat pump-based HVAC and water heater systems can be approx. three times more efficient than their conventional counterparts for space and water heating. While awareness and adoption of VHE heat pumps has been growing nationally, and electric heat pump systems have outsold gas furnaces for two years in a row, the MF segment continues to lag behind single-family. MF constitutes almost a third of the housing in the U.S., so scaling up VHE adoption in this segment can assist in achieving critical climate change goals, while preserving housing affordability for the low-to-moderate income (LMI) population (historically, 85% of residents of MF are LMI).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Installation of Direct Water-Cooling Systems to Reduce Cooling Energy Requirements for High-Performance Computing Centers

A large cluster of High-Performance Computing (HPC) equipment at the Lawrence Livermore National Laboratory in California was retrofitted with an Asetek cooling system. The Asetek system is a hybrid scheme with water-cooled cold plates on high-heat-producing components in the information technology (IT) equipment, and with the remainder of the heat being removed by conventional air-cooling systems. In order to determine energy savings of the Asetek system, data were gathered and analyzed two ways: using top-down statistical models, and bottom-up engineering models. The cluster, “Cabernet”, rejected its heat into a facilities cooling water loop which in turn rejected the heat into the same chilled water system serving the computer-room air handlers (CRAHs) that provided the air-based cooling for the room. Because the “before” and “after” cases both reject their heat into the chilled water system, the only savings is due to reduction in CRAH fan power. The top-down analysis showed a 4% overall energy savings for the data center (power usage effectiveness (PUE) —the ratio of total data center energy to IT energy— dropped from 1.60 to 1.53, lower is better); the bottom-up analysis showed a 3% overall energy savings (PUE from 1.70 to 1.66) and an 11% savings for the Cabernet system by itself (partial PUE of 1.51). Greater savings, on the order of 15-20%, would be possible if the chilled water system was not used for rejecting the heat from the Asetek system. About 37% of the heat from the Cab system was rejected to the cooling water, lower than at other installations.

Earni, Shankar↗

Field Validation of Electrochemical Water Filtration System on Open Loop Cooling Towers at Automotive Plants

Open loop cooling towers play a pivotal role in rejecting heat for chilled water systems serving industrial processes, heating, ventilation, and air conditioning loads. Exposure to outside conditions can present certain operating challenges to system performance including scaling, corrosion, and biological growth. These issues are mitigated through the use of effective cooling tower water filtration and treatment systems to reduce contaminants—along with other total suspended solids (TSS) and total dissolved solids (TDS)—in the system. The U.S. Department of Energy’s Industrial Efficiency and Decarbonization Office is interested in an electrochemical-based filtration system with the ability to remove TSS particulate down to 1 micron. The removal of finer particulates reduces the need for blowdown and, in turn, makeup water use and chemical treatment in the cooling tower. Additionally, the removal process can reduce fouling at the condensers, resulting in better heat exchange and energy savings. Two Industrial Technology Validation program projects validated the electrochemical water filtration system at the Toyota Motor Manufacturing, Mississippi plant in Blue Springs, Mississippi, and the Nissan Canton Vehicle Assembly Plant in Canton, Mississippi. Researchers found that installation of both systems resulted in water and chemical treatment savings with minimal impact on energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geothermal Direct-Use Applications for the District Energy System in Bucharest, Romania

The city of Bucharest, Romania, hosts the second-largest district energy system (DES) in the world. Geothermal resources can be considered as a supplementary heat source to support the demand for domestic hot water and space heating in the winter and shoulder seasons. The National Laboratory of the Rockies (NLR) has conducted a study that considers geothermal energy to serve a fraction of the existing district heating network operated by Electrocentrale Bucure?ti (ELCEN), the utility operating the DES. Lower Cretaceous and Jurassic limestones make up the main geothermal aquifer underlying Bucharest, which hosts temperatures suitable for district heating (up to 90 degrees C to the north of the city). Anomalous geothermal gradients have been observed to the north of the city, where a pumped well has produced 82 degrees C brine at the wellhead to feed the Therme Bucharest Spa. An anomalous gradient has also been reported to the southeast of the city (35 degrees C/km). NLR modeled the building heating loads of a small portion of the DES (a block of nine prototypical buildings) in its Urban Renewable Building and Neighborhood Optimization (URBANopt ) platform. To simulate meeting a baseload benchmark of 20 MWth deliverable to a small portion of the DES, the NLR team used GEOPHIRES to model production scenarios for (1) hydrothermal systems coupled with heat pumps targeting the main geothermal aquifer in the north, (2) enhanced geothermal systems targeting hot dry rock in the southeast, and (3) huff-and-puff systems targeting a gradient of 25 degrees C/km. Finally, NLR conducted a high-level sensitivity study around the techno-economics of these systems. The outcomes of this work indicate that hot dry rock geothermal resources that can deliver at least 90 degrees C hot water to the Geothermal District Energy System (GeoDES) offer a possible solution for supplemental geothermal heat delivered to the existing DES.

15 GEOTHERMAL ENERGY↗

Thermoelectric heating and cooling–integrated dishwasher with thermal energy storage

Household dishwashers must address several performance goals: maximize washing and drying performance, while minimizing cycle duration, energy consumption, and water consumption. This study develops and examines a novel thermoelectric heating and cooling (TEHC) system with thermal energy storage applied to a household dishwasher (DW), aiming to improve the energy and drying performance of a commercially-available dishwasher while maintaining its washing performance, water consumption, and cycle duration. Experimental testing conducted on the novel TEHC-DW system demonstrates an 8.7% reduction in total energy consumption, lowering the per-cycle usage to 0.952 kWh, and a 40% reduction in energy consumption for internal water heating. The novel TEHC-DW system also demonstrates better drying performance, shortening the drying time by 42% to reach the same remaining moisture content as a commercially-available system. In addition, a resistance-capacitance network model is developed that predicts total drying time, total energy consumption, and the highest temperature reached in the tub (53.4 °C). The model accuracy is validated with experimental data (within ±1 K), and the model functions as a design tool via a parametric study to evaluate the next-generation design and the effect of the number of thermoelectric modules and thermoelectric driving force (i.e., current). Overall, this study demonstrates the potential for TEHC technology to improve energy efficiency and drying performance in household dishwashers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

VitriEdge: Repairable & Durable Vitrimer Coatings for Wind Turbine Blade Leading Edges

The primary goal of this Level 1b incubator project was to explore the use of vitrimer coatings for repair of leading-edge erosion on end-of-life wind turbine blade surfaces, beyond coating strength of adhesion which has previously been demonstrated in the Level 1a project. Uniform vitrimer coatings (thickness: 400 µm) were applied to two end-of-life wind turbine blades for flexural, fatigue, and laminate tensile testing where the addition of the coating did not produce any statistical variation in tensile properties with minor drops in flexural strength for some laminate formulations. However, a <2% variation in storage modulus was measured for laminate structures (i.e., blade samples with vitrimer coatings) across 100,000 flexural cycles and upon laminate tensile failure, the vitrimer coatings displayed no visible signs of delamination. In addition, three methods to heal vitrimer coating damage was displayed: oven heating, addition of hot water, and a forced convection heat gun. All three heating and healing mechanisms demonstrated significant healing with scratch depths decreasing between 79-91% at healing times ranging between 1-min and 10-minutes. Finally, a water jet machine was used to simulate rain erosion for both the blade surfaces and vitrimer-coated blade surfaces where the diameter and depth of the damage was recorded as a function of exposure time, water pressure, height of exposure, and angle of exposure. Of interest, while the vitrimer coating did not significantly lessen the damage experienced during rain erosion, the addition of vitrimer composite coatings(5 wt.% mica addition) did result in a crack-resistant, durable coating capable of self-healing behavior and in all cases the angle of rain exposure was the most critical parameter explored. It is crucial to continue exploring this space where vitrimer coatings are of interest for both their self-healing properties and potential use as reversible adhesives.

17 WIND ENERGY↗

The selective heating effect of microwave irradiation on a binary mixture of water and polyethylene oxide: a molecular dynamics simulation approach

In this study, we investigate the molecular mechanisms of a microwave-driven selective heating process by performing molecular dynamics simulations for three different systems including pure water, pure polyethylene oxide (PEO), and water-PEO mixed systems in the presence of a microwave with two different intensities of electric field such as 0.001 V/Å -1 and 0.01 V/Å -1 at a frequency of 100 GHz. First, from performing molecular dynamics simulations of CO and CO 2 in the presence of the microwave, it is confirmed that the molecular dipole moment is responsible for the rotational motion induced by the oscillating electric field. Second, by analyzing the MD simulations of the pure water system, we discover that the dipole moment of water exhibits a time lag with respect to the microwave. During the heating process, however, the temperature, kinetic, and potential energies increase synchronously with the oscillating electric field of the microwave, showing that the heating of the water system is caused by the molecular reaction of water to the microwave. Comparing the water-PEO mixed system to the pure water and pure PEO systems, the water-PEO mixed system has a higher heating rate than the pure PEO system but a lower heating rate than the pure water system. Therefore, we conclude that heating the water-PEO mixed system is driven by water molecules selectively activated by microwave irradiation. Furthermore, we also calculate the diffusion coefficients of water molecules and PEO chains by describing their mean square displacements, demonstrating that the diffusion coefficients are increased in the presence of microwaves for both water and PEO in pure and mixed systems. Lastly, during the microwave heating process, the structures of the water-PEO mixed system are altered as a function of the intensity of electric field, which is mainly driven by the response of water molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technoeconomic Benefits of Film-Forming Amine Products Applied to Steam Surface Condensers

In a conventional Rankine cycle, the majority of power plants employ surface condensers that use pumped cooling water to reject heat from the cycle. In such cases, heat rejection occurs in a shell and tube heat exchanger by film-wise condensation of low-pressure steam on stainless steel, titanium, brass, or copper-nickel tubing. To improve the thermal performance of steam surface condensers, a replenishable film-forming substance (FFS) can be ap-plied to the condenser tubing to promote efficient dropwise condensation. Conventionally, film-forming amine prod-uct (FFAP) coatings protect boiler surfaces from oxidative corrosion, which substantially reduces the operation and maintenance costs. To quantify the technical and economic benefits of FFAP coatings applied to condenser tubing due to the promotion of dropwise condensation, a thermal resistance network model was established. Using a rep-resentative steam surface condenser, the improvements in thermal performance (overall heat transfer coefficient) and process parameters (net plant efficiency, cooling water flowrate, and turbine backpressure) were determined due to the enhancement in the condensation heat transfer coefficient. Experimentally measured condensation heat transfer coefficients for common condenser materials were compared with the modeling results and were found to be within attainable bounds. Lastly, the trend in total heat exchanger cost reduction is generalized to understand the trade-off between reduced surface area for heat rejection and increase in coating application costs for a re-plenishable coating system.

20 FOSSIL-FUELED POWER PLANTS↗

Application of a Novel Heat Pump Model for Estimating Economic Viability and Barriers of Heat Pumps in Dairy Applications in the United States

Heat pumps represent an important opportunity for energy savings and decarbonization. This work investigates the techno-economic performance of high-temperature heat pumps (HTHPs) for use in the U.S. dairy industry. The studied heat pump performs a 50 °C temperature lift on a waste heat stream of cleaning water and applies the upgraded heat stream to a fluid milk pasteurization process. This work involved the creation of a HTHP model that estimated the coefficient of performance (COP), internal rate of return (IRR), net present value (NPV), and payback period (PBP), and emissions saved for a heat pump replacing a natural gas boiler. Capital costs, operations, and maintenance (O&M) cost, heat pump lifetime, electricity prices, natural gas prices, and a cost of carbon were varied to perform a parametric study on the factors affecting the break-even price of HTHPs. The results show that HTHP economics are highly sensitive to COP and energy price environment, and less sensitive to capital and O&M cost variance, leading to a large scatter of positive and negative NPVs based on U.S. location. PBPs demonstrate a defined threshold, based on energy price environment, below which favorable two-to-three-year PBPs predominate. This work is focused on the U.S. dairy industry, but international application in relation to fossil vs. electricity price regimes. Heat pumps have seen wider adoption in regions with a high ratio of fossil energy to electricity prices ($/MMBTU vs. $/kWh). The U.S. has plentiful natural gas resulting in lower fossil energy prices which has reduced heat pump adoption. This paper identifies potential first mover industries for HTHP adoption and their associated price regimes even in regions with lower ratios of fossil energy to electricity prices that exist many places globally.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Using ‘heat tagging’ to understand the remote influence of atmospheric diabatic heating through long-range transport

In the circulating atmosphere, diabatic heating influences the potential temperature content of air masses far from where the heating occurs. Budgets that balance local diabatic sources with local heat divergence and storage do not retain information about this remote influence, which requires air-mass tracking. In this study, a process based, passive-tracer diagnostic, called heat tagging, is introduced. Heat tagging locally decomposes the potential temperature into contributions from the distinctive diabatic processes that generate them, wherever they occur. The distribution, variability and transport of atmospheric heat tags are studied in the relatively simple setting of an idealized aquaplanet model. Heat tags from latent heating are generated in the deep tropics and the midlatitude storm track and then transported throughout the troposphere. By contrast dry sensible heat tags are enhanced near the surface, and radiative tags are mainly confined to the stratosphere. As a result, local heat transport, variability of potential temperature and global poleward heat transport are dominated by heat tags related to latent heating, with heat tags from sensible and radiative heating only making contributions in the polar near surface and the stratosphere respectively. Heat tagging thus quantifies how water vapor and latent heating link the structural characteristics of the atmosphere and illustrates the importance of the hydrological cycle in poleward energy transport.

54 ENVIRONMENTAL SCIENCES↗

Data from: 'Abiotic influences on continuous conifer forest structure across a subalpine watershed'

This package archives the core data used for analysis and inference in 'Abiotic influences on continuous conifer forest structure across a subalpine watershed' (Worsham et al., 2025). All data were collected in the East River, Washington Gulch, Slate River, and Coal Creek watersheds of Colorado. In the paper, we quantified the relative influence of climate, topographic, edaphic, and geologic factors on conifer stand structure and composition, and their functional relationships, at the watershed scale. We used waveform LiDAR data to derive spatially continuous stand structure metrics. We fused these with a species-level classification map to estimate tree species abundance. We applied generalized additive and generalized boosted models to evaluate the covariability of structural and compositional metrics with abiotic variables. The package contains the essential products required for reproducing our analysis and the tables and figures reported in the publication. The products comprise four classes: (1) geospatial data, (2) tabular data used for inferential analysis, (3) tabular data describing analytical results and performance statistics, and (4) a data user guide. (1) includes discretized waveform LiDAR data, locations and attributes of individual tree crowns, sampling locations and domain boundaries, a canopy height model, and raster files of estimated forest structural and compositional metrics at 100 m grid scale. (2) includes all response and explanatory variable values applied in inferential models. Response variables include conifer forest stand density, basal area, 95th percentile height, quadratic mean diameter, and others. Explanatory variables include climatic water deficit, actual evapotranspiration, elevation, heat load, soil available water content, and others. (3) includes results of training and testing several individual tree detection (ITD) algorithms, as well as inferential modeling results. (4) is a PDF user guide for this data package, including detailed descriptions and data dictionaries for all files. The data package root contains 17 assets: 8 compressed tape archive (.tar.gz) files, 5 comma-separated values (.csv) files, 3 Geographic Tagged Image File Format (GeoTIFF) (.tif) files, and 1 Portable Document Format (.pdf) file. The compressed .tar.gz archives contain ESRI shapefiles (.shp) .tif, compressed LASer (.laz), and .csv files. The archives must first be decompressed using the widely distributed command-line software utility TAR. All other files, including constituent files within the .tar.gz archives, can be opened in the open-source R statistical computing environment. Alternatively, .csv files may also be read in any simple text editor software or Microsoft Excel. Geospatial files including .shp and .tif files can also be opened in GIS software, such as QGIS (open-source) or ESRI ArcGIS (proprietary). The .pdf Data User Guide can be read with Adobe Acrobat Reader or other compatible readers.

2018 NEON and 2025 CHESS Campaigns↗

Observational Constraints on the Spatial Effect of Greenness and Canopy Cover on Urban Heat in a Major Midlatitude City

Abstract Urban heat stress is a critical issue, particularly in cities where dense infrastructure and limited green space exacerbate temperature extremes. This study investigates the impact of greenery (EVI2), canopy cover (CC), impervious cover (IC), and water bodies on heat index in Chicago using high‐resolution data from the Heat Watch campaign. We find that EVI2, CC and proximity to water body significantly reduce heat while IC increases heat, particularly in the afternoon when solar radiation is intense. Additionally, the effective radius that land cover impacts heat is smaller in the afternoon. The combined effect analysis indicates that enhancing total greenness, not just canopy cover, is the most effective strategy to reduce heat. This study underscores the importance of strategic vegetation management, highlighting the critical role of integrated approaches in reducing urban heat.

Lee, Jangho↗

Dimensionless parameters for cloudy Rayleigh-Bénard convection: Supersaturation, Damköhler, and Nusselt numbers

In steady-state Rayleigh-Bénard convection, heat is transported by turbulent thermal convection from the bottom, hot surface to the top, cold surface, leading to a height-independent sensible heat flux. When water vapor is present and cloud formation occurs, there is also an additional latent heat flux. Heat transport in cloudy Rayleigh-Bénard convection depends on turbulent flow as well as the microphysical state of the clouds: specifically, whether substantial supersaturations exist and whether cloud liquid water is removed through sedimentation/precipitation. In this article we bridge between the Rayleigh-Bénard convection literature and the atmospheric literature. We express the governing equations for cloudy convection in dimensionless form, thereby explicitly identifying the governing parameters relevant to the cloudy case, including Schmidt, Damköhler, supersaturation, and sedimentation numbers. We further connect to the atmospheric literature by obtaining a Nusselt number (dimensionless heat flux) for a cloud-convection system, directly from the conservation equations for temperature and water vapor. This flux has the same form as that identified by Zhang et al. [L. Zhang, K. L. Chong, and K.-Q. Xia, J. Fluid Mech. 874, 1041 (2019)] for convection with water vapor, but is extended to the cloudy case. For equal thermal and water vapor diffusivities, the flux corresponds to the widely used atmospheric quantities equivalent temperature and moist static energy. Using large eddy simulation (LES) of an idealized cloudy Rayleigh-Bénard convection system with fixed boundary conditions, we find that the equivalent heat flux (Nusselt number) is only weakly dependent on the microphysical details of the system, such as liquid water mixing ratio and cloud droplet number concentration. Finally, from the results, we show the vertical profiles of sensible and latent heat fluxes depend on the liquid water content, whereas the equivalent heat flux remains a constant throughout the height of the chamber.

54 ENVIRONMENTAL SCIENCES↗

Flow and Heat Transfer Experimental Study for 3D-Printed Solar Receiving Tubes With Helical Fins at Internal Surface

3D-printing technology was applied to fabricate novel solar thermal collection tubes that have internal heat transfer enhancement fins and external surfaces with high solar absorptivity and low emissivity due to the ability to use different materials in one tube. Helical fins were selected to introduce circumferential flow and thus minimize the circumferential temperature difference of the tube that receives sunlight on one side. The structures of the helical fins were previously optimized from computational fluid dynamics (CFD) analysis with the objective of low entropy production rate by looking for high heat transfer coefficient and relatively lower pressure loss. High-temperature alloy, Inconel-718, was used to 3D print the tubes, which can resist corrosion for the potential application of molten chloride salts as heat transfer fluid. Experimental tests were carried out using water as the heat transfer fluid with the high heat flux provided by a tubular furnace heater. The tested Reynolds number ranges from 3.9 × 10 3 to 6.1 × 10 4 . Heat transfer coefficients of up to 2.8 times that of the smooth tube could be obtained with the expense of increased pressure loss compared to that of the smooth tube. The total system entropy generation can be significantly reduced due to the benefit of heat transfer enhancement that is greater than the expenses of the increased pressure loss. The experimental results of the 3D-printed heat transfer tubes confirmed the CFD-based results of fin optimization. Furthermore, the novel heat transfer tube is recommended for application in concentrating solar power systems.

14 SOLAR ENERGY↗

Introduction to this special section: Geothermal energy

Geothermal energy is a global renewable resource that has the potential to provide a significant portion of baseload energy in many regions. In the United States, it has the potential to provide 8.5% of the electric generation capacity by the middle of the century. In general, geothermal systems require heat, permeability, and water to be viable for energy generation. However, with current technologies, only heat is strictly necessary in a native system. Engineered geothermal systems (EGS) introduce water into the subsurface at elevated pressures and reduced temperatures and enhance permeability through hydraulic and/or shear fracturing. Additionally, although moderate- to high-temperature resources currently dominate geothermal energy production, low-temperature resources have been utilized for direct-use cases. When well balanced and maintained, geothermal resources can produce significant amounts of heat and achieve long-term sustainability on the order of an estimated tens to hundreds of years.

15 GEOTHERMAL ENERGY↗