Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerating cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Review of the application piezoelectric actuators for SRF cavity tuners

Modern particle accelerators and high-energy physics experiments that deployed up to several hundred of accelerating superconducting RF cavities require accurate frequency control. This is achieved by using cavity tuners typically actuated with the piezoelectric ceramic actuators. Piezoelectric ceramic actuators have become "standard" components of the SRF cavity tuner and depending on the application could be operated in different environments: in air, at cryogenic temperature, in vacuum, and submerged in liquid helium. Different applications place different requirements on the piezo actuators, but the important parameters common to all applications are the lifetime and reliability of the actuators. Several programs targeting the development of reliable piezo actuators are presented in this contribution.

43 PARTICLE ACCELERATORS↗

Review of the application piezoelectric actuators for SRF cavity tuners

Modern particle accelerators and high-energy physics experiments that deployed up to several hundred of accelerating superconducting RF cavities require accurate frequency control. This is achieved by using cavity tuners typically actuated with the piezoelectric ceramic actuators. Piezoelectric ceramic actuators have become “standard” components of the SRF cavity tuner and depending on the application could be operated in different environments: in air, at cryogenic temperature, in vacuum, and submerged in liquid helium. Different applications place different requirements on the piezo actuators, but the important parameters common to all applications are the lifetime and reliability of the actuators. Several programs targeting the development of reliable piezo actuators are presented in this contribution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tuner of a Second Harmonic Cavity of the Fermilab Booster

Introducing a second harmonic cavity in the accelerating system of the Fermilab Booster promises significant reduc-tion of the particle beam loss during the injection, transi-tion, and extraction stages. To follow the changing energy of the beam during acceleration cycles, the cavity is equipped with a tuner that employs perpendicularly biased AL800 garnet material as the frequency tuning media. The required tuning range of the cavity is from 75.73 MHz at injection to 105.64 MHz at extraction. This large range ne-cessitates the use of a relatively low bias magnetic field at injection, which could lead to high RF loss power density in the garnet, or a strong bias magnetic field at extraction, which could result in high power consumption in the tuner’s bias magnet. The required 15 Hz repetition rate of the device and high sensitivity of the local RF power loss to the level of the magnetic field added to the challenges of the bias system design. In this report, the main features of a proposed prototype of the second harmonic cavity tuner are presented.

43 PARTICLE ACCELERATORS↗

HIGH POWER TEST OF RF SEPARATOR FOR 12 GEV UPGRADE OF CEBAF AT JLAB

CEBAF at JLab is in the process of an energy upgrade from 6 GeV to 12 GeV. The existing setup of the RF separator cavities in the 5th pass will not be adequate to extract the highest energy (11 GeV) beam to any two existing halls (A, B or C) while simultaneously delivering to the new hall D in the case of the proposed 12 GeV upgrade of the machine. To restore this capability, we are exploring the possibility of extension of existing normal conducting 499 MHz TEM-type rf separator cavities. Detailed numerical studies suggest that six 2-cell normal conducting structures meet the requirements; each 2-cell structure will require up to 4 kW RF input power in contrast with the current nominal operating power of 1.0 to 2.0 kW. A high power test of 4 kW confirms that the cavity meet the requirement.

43 PARTICLE ACCELERATORS↗

Tuning microwave losses in superconducting resonators

Abstract The performance of superconducting resonators, particularly cavities for particle accelerators and micro cavities and thin film resonators for quantum computations and photon detectors, has been improved substantially by recent material treatments and technological advances. As a result, the niobium cavities have reached the quality factors Q ∼ 10 11 at 1–2 GHz and 1.5 K and the breakdown radio-frequency (rf) fields H close to the dc superheating field of the Meissner state. These advances raise the questions of whether the state-of-the-art cavities are close to the fundamental limits, what these limits actually are, and to what extent the Q and H limits can be pushed by the materials nano structuring and impurity management. These issues are also relevant for many applications using high-Q thin film resonators, including single-photon detectors and quantum circuits. This topical review outlines basic physical mechanisms of the rf nonlinear surface impedance controlled by quasiparticles, dielectric losses and trapped vortices, as well as the dynamic field limit of the Meissner state. Sections cover methods of engineering an optimum quasiparticle density of states and superfluid density to reduce rf losses and kinetic inductance by pairbreaking mechanisms related to magnetic impurities, rf currents, and proximity-coupled metallic layers at the surface. A section focuses on mechanisms of residual surface resistance, which dominates rf losses at ultra low temperatures. Microwave losses of trapped vortices and their reduction by optimizing the concentration of impurities and pinning potential are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tunneling study of SRF cavity-grade niobium.

Niobium, with its very high H{sub C1}, has been used in superconducting radio frequency (SRF) cavities for accelerator systems for 40 years with continual improvement. The quality factor of cavities (Q) is governed by the surface impedance R{sub BCS}, which depends on the quasiparticle gap, delta, and the superfluid density. Both of these parameters are seriously affected by surface imperfections (metallic phases, dissolved oxygen, magnetic impurities). Loss mechanism and surface treatments of Nb cavities found to improve the Q factor are still unsolved mysteries. We present here an overview of the capabilities of the point contact tunneling spectroscopy and Atomic layer deposition methods and how they can help understanding the High field Q-drop and the mild baking effect. Tunneling spectroscopy was performed on Nb pieces from the same processed material used to fabricate SRF cavities. Air exposed, electropolished Nb exhibited a surface superconducting gap Delta = 1.55 meV, characteristic of clean, bulk Nb, however the tunneling density of states (DOS) was broadened significantly. Nb pieces treated with the same mild baking used to improve the Q-slope in SRF cavities revealed a much sharper DOS. Good fits to the DOS are obtained using Shiba theory suggesting that magnetic scattering of quasiparticles is the origin of the degraded surface superconductivity and the Q-slope problem of Nb SRF cavities.

43 PARTICLE ACCELERATORS↗

Development of High-efficiency and Cost-effective Forged Ingot Niobium Technology for Science Frontiers and Accelerator Applications

Development of Forged Ingot Niobium Technology: Worlds science frontier programs and SRF accelerator applications demand high performance and cost-effective SRF accelerator technology [1-8]. Fine-grain (FG) and Large-grain (LG) ingot niobium technologies have been very well developed and implemented in all the present-day accelerator projects. However, forged ingot niobium technology which is the focus of this development proposal will be much more cost-effective and expected to have several technical advantages. FG niobium sheet production is very complex involving more than ten processing steps making them prone to contamination. As a result, they are very expensive to produce and require stringent QA procedure to be ready for SRF cavity production. The accelerating cavity process steps are also numerous and require strict procedures in order to achieve high accelerating gradients and quality factors needed for science frontier programs. LG niobium disc production, directly sliced from the ingot, is relatively simple and straight forward to keep surface cleanness. The disc production cost is significantly low compared to FG niobium sheet production. However, there are (some) draw backs due to non-homogeneity of the grain boundary distribution, resulting in non-uniform mechanical properties and complex cavity fabrication, although the LG cavities achieve the expected high-gradient performance goals with lower cost. Medium-grain (MG) niobium disk production may be realized with a new approach/process, the disc directly sliced from the forged ingot, involves a simpler process steps contributing major production cost reduction [9]. These discs are expected to be superior as they tend to be homogenous with uniform sub millimeter grains and mechanical properties. We are eagerly looking forward to developing the forged ingot niobium SRF accelerator technology for the benefit of the world-wide science frontier programs, green energy subcritical nuclear energy systems and a wide variety of industrial applications including the production of radio isotopes and nuclear transmutation applications. Measurement of thermal characteristics of the forged ingot niobium: Measurement of the thermal diffusivity, D, of superconducting MG niobium is important to be understood in comparison with FG sheet and LG disc, as well as that of advanced composite material of Nb3Sn film sputtered on forged ingot Nb, which will be determined using transient pump-probe thermo-modulation [10,11]. Transient thermo-modulation is based on using an ultrafast laser pulse to heat the superconducting materials by a few K, then a synchronized laser pulse probes the reflectance of the heated material. For thin films on a substrate (e.g, 100-nm Nb3Sn on Nb), it takes <100 ps for the heat to reach the substrate by diffusion. Therefore, an ultrafast method is needed to probe D of the studied material. D will be measured from room temperature to liquid helium temperatures. Fundamental Research: The increase of rf loss in SRF cavities is related to trapping of residual magnetic field during the cavity cool-down. The study suggested that the micro structure plays the role in flux trapping sensitivity. The research includes the flux trapping and expulsion study as forged ingot niobium goes through several mechanical deformations, crystallization leading to the optimal SRF cavity performance. Furthermore, the cavity made from FG, MG, and LG sheet/disc will be compared to understand the optimal re-crystallization temperature that cavity needed to be heat treated which minimize the flux trapping and increase SRF cavity performance. References: 1. S. Belomestnykh, Overview of recent SRF developments for ERLs, presented at the SRF 2015, Whistler, BC, Canada (2015). 2. A. Yamamoto, M. Yamanaka and G. Myneni, Ingot Nb based SRF Technology for the International Linear Collider, in Science and Technology of Ingot Niobium for Superconducting Radio Frequency Applications, AIP Conf. Proc. 1687, 030005-1 ? 03005-6, 2015 3. Report of the Workshop on Energy and Environmental Applications of Accelerators, DOE Workshop Report. https://science.osti.gov/-/media/hep/pdf/Reports/2020/CASM_WorkshopReport.pdf? la=en&hash=AEB0B318ED0436B1C5FF4EE0FDD6DEB84C2F15B2 4. G. Ciovati, et al., Design of a cw, low-energy, high-power superconducting linac for environmental applications, Phys. Rev. Accel. Beams 21, 091601 (2018). 5. P. Dhakal, et al., Effect of high temperature heat treatments on the quality factor of a large-grain superconducting radio-frequency niobium cavity, Phys. Rev. ST Accel. Beams 16, 042001 (2013). 6. P. Kneisel et al., Review of ingot niobium as a material for superconducting radio frequency accelerating cavities, Nuclear Instruments and Methods in Physics Research A 774, 133 (2015). 7. G. Ciovati, P. Dhakal, and G. R, Myneni, Superconducting radio-frequency cavities made from medium and low-purity niobium ingots, Supercond. Sci. Technol. 29, 064002 (2016). 8. M. Drury et al., commissioning of the prototype C75 cavities in a CEBAF cryomodule, in Proc. of IPAC 2018, Vancouver, BC, Canada (2018) 9. Feasibility of forged-ingot niobium disc and SRF cavity fabrication technology recently demonstrated in cooperation of ATI, BSCE, and KEK (2020). 10. Hani E. Elsayed-Ali, ?Measurements of heat transport in thin films by ultrafast laser-based techniques,? 3rd International Conference on Thermal Issues in Emerging Technologies Theory and Applications, Cairo, Egypt, pp. 347 ? 350 (2010). DOI: 10.1109/ThETA17616.2010 11. W. M. G. Ibrahim, H. E. Elsayed-Ali, M. Schinn, and C. A. Bonner, Jr., ?Ultrafast investigation of electron dynamics in multilayer metals,? Int. J. Heat and Mass Transfer, 47(10?11), 2261?2268 (2004).

Myneni, G.↗

Parametric-resonance ionization cooling of muon beams

Parametric-resonance Ionization Cooling (PIC) is proposed as the final 6D cooling stage of a high-luminosity muon collider. Combining muon ionization cooling with parametric resonant dynamics should allow an order of magnitude smaller final equilibrium transverse beam emittances than conventional ionization cooling alone. In this scheme, a half-integer parametric resonance is induced in a cooling channel causing the beam to be naturally focused with the period of the channel's free oscillations. Thin absorbers placed at the focal points then cool the beam's angular divergence through the usual ionization cooling mechanism where each absorber is followed by RF cavities. A special continuous-field twin-helix magnetic channel with correlated behavior of the horizontal and vertical betatron motions and dispersion was developed for PIC. We present the results of modeling PIC in such a channel using GEANT4/G4beamline. We discuss the challenge of precise beam aberration control from one absorber to another over a wide angular spread.

43 PARTICLE ACCELERATORS↗

High-Intensity Proton Accelerator

Analysis is presented for an eight-cavity proton cyclotron accelerator that could have advantages as compared with other accelerators because of its potentially high acceleration gradient. The high gradient is possible since protons orbit in a sequence of TE111 rotating mode cavities of equally diminishing frequencies with path lengths during acceleration that greatly exceed the cavity lengths. As the cavities operate at sequential harmonics of a basic repetition frequency, phase synchronism can be maintained over a relatively wide injection phase window without undue beam emittance growth. It is shown that use of radial vanes can allow cavity designs with significantly smaller radii, as compared with simple cylindrical cavities. Preliminary beam transport studies show that acceptable extraction and focusing of a proton beam after cyclic motion in this accelerator should be possible. Progress is also reported on design and tests of a four-cavity electron counterpart accelerator for experiments to study effects on beam quality arising from variations injection phase window width. This device is powered by four 500-MW pulsed amplifiers at 1500, 1800, 2100, and 2400 MHz that provide phase synchronous outputs, since they are driven from a with harmonics derived from a phase-locked 300 MHz source.

43 PARTICLE ACCELERATORS↗

World-Wide Experience with SRF Facilities

The speaker will review and analyze the performance of existing SRF facilities in the world, addressing issues of usage and availability for different customers (HEP research, material sciences, ADS). Lessons learned should be summarized for proposed future facilities (ILC, Project X, Muon Collider). The first use of superconducting cavities for accelerating beams was at HEPL, Stanford University in the early sixties. Rather quickly, other laboratories followed suit, notably the University of Illinois at Champagne, Urbana and Cornell University. There were two main uses, which still persist today. The first is to provide accelerated particles as an injector or for fixed target experiments. The second is to maintain circulating beams, either for synchrotron light sources or for colliding beam experiments. Given the differing requirements, these two uses led to rather different implementations and, in particular, different average operating gradients. A second difference in the implementation is the speed of the particle being accelerated. Electrons are sufficiently relativistic at low beam energies (> {approx} 5 MeV) that cavities designed for relativistic beams can also function acceptably at low energy. This is not the case for protons or ion accelerators so, until recently, copper cavities were used to cover the first {approx} 100 MeV. Superconducting cavities are now also being proposed to cover this energy range as well using a series of superconducting cavities, each of which is matched to the particle velocity.

43 PARTICLE ACCELERATORS↗

Insight to the Duration of 120 °C Baking on the Performance of SRF Niobium Cavities

Low-temperature baking at 100 °C - 140 °C in ultra-high vacuum for several hours is the final cavity processing technique to achieve the highest accelerating gradient cavity by eliminating the high field Q-slope, typically on cavities made of high purity fine grain niobium and subjected to electropolishing. The temperature and duration of baking control the onset of the high field Q-slope and overall quality factor over the baseline measurements. The increase in quality factor is generally related to the reduction in the temperature-dependent surface resistance, which refers to BCS surface resistance due to the reduction in the electronic mean free path and elimination of high field Q-slope is still being actively investigated. Here, we present the results of a series of measurements on 1.3 GHz TESLA shape single-cell cavities with successive low-temperature baking at 120 °C up to 96 hours. The rf loss related to the trapping of residual magnetic field refer to flux trapping sensitivity was measured with respect to the duration of 120 °C bake.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of Open Waveguide RF Hazard

Radiofrequency (RF) radiation is used in particle accelerators to develop electromagnetic fields in resonant cavities coupled to the RF source. Particles passing through the aperture in a resonant cavity are accelerated by the electric field and deflected by the magnetic field. Accelerator staff manage RF exposure hazards by using a robust combination of engineered safeguards and administrative controls - much like other industrial hazards. Consequently, direct exposure to RF (from an open wave guide, for example) is an extremely unlikely scenario. However, it is important to eliminate any scenario that might lead to such an event and it is instructive to evaluate the prompt somatic effects. This presentation discusses one possible scenario by which hazardous RF exposure can occur at a particle accelerator and the possible outcomes.

May, Robert↗

Superconducting low-beta Nb 3 Sn cavity for ATLAS and future ion accelerators

We report on a Nb 3 Sn-coated low-beta superconducting radio frequency (RF) cavity intended for accelerating ions. We aim to apply the cavity in ATLAS, our Argonne National Laboratory user facility for nuclear physics studies with ion beams in the energy range of 5–20 MeV u −1 . The Nb 3 Sn-coated cavity, a 145 MHz quarter-wave optimized for ions moving with velocity β = $v/c$ = 0.08 exhibits an order-of-magnitude reduction in RF losses into helium at 4.4 K compared to a superconducting niobium (Nb) cavity at the same frequency and temperature. Experimentally measured fields are among the highest to date for any Nb 3 Sn-coated cavity, reaching a peak surface magnetic field of 105 mT. We also present a practical solution to the problem of cavity frequency tuning. Tuning by mechanical deformation has been a challenge with Nb 3 Sn due to its brittle nature, however, using a set of techniques tailored to the properties of thin-film Nb 3 Sn on Nb, we can repeatably tune the cavity to the ATLAS master clock frequency after it is cooled, while maintaining the excellent performance characteristics. The same Nb 3 Sn cavity technology offers broad benefits for future ion accelerators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of a Prototype Superconducting Radio-Frequency Cavity for Conduction-Cooled Accelerators

Recent progress in the development of high-quality Nb?Sn film coatings along with the availability of cryocoolers with high cooling capacity at 4 K makes it feasible to operate SRF cavities cooled by thermal conduction at relevant accelerating gradients for use in accelerators. We have developed a prototype single-cell cavity to prove the feasibility of operation up to the accelerating gradient required for 1 MeV energy gain, cooled by conduction with cryocoolers. The cavity has a ~3 ¿m thick Nb?Sn film on the inner surface, deposited on a ~4 mm thick bulk Nb substrate and a bulk ~7 mm thick Cu outer shell with three Cu attachment tabs. The cavity was tested up to a peak surface magnetic field of 53 mT in liquid He at 4.3 K. A horizontal test cryostat was designed and built to test the cavity cooled with three cryocoolers. The rf tests of the conduction-cooled cavity achieved a peak surface magnetic field of 50 mT and stable operation was possible with up to 18.5 W of rf heat load. The peak frequency shift due to microphonics was 23 Hz. These results represent the highest peak surface magnetic field achieved in a conduction-cooled SRF cavity to date

Ciovati, Gianluigi↗