Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Advancements in Force and Angle Measurement by the NFMTC

The National Force Measurement Technology Capability (NFMTC) is a nationwide partnership established in 2008 and sponsored by NASA’s Aeronautics Evaluation and Test Capabilities (AETC) project to maintain and further develop force and angle measurement capabilities primarily for NASA’s ground test facilities. One of the NFMTC’s primary objectives is to develop new force and angle measurement capabilities to meet the needs of researchers testing in NASA’s ground test facilities. This work will highlight several new capabilities that are either at or near operational readiness. A new six-component flow-through balance was designed and fabricated to support an upcoming retropropulsion test campaign at the NASA Langley Unitary Plan Wind Tunnel. The balance employs membranes in place of bellows, which have historically been used, and passes the flow through load bearing parts of the balance. Flow through the balance is optimized via the addition of flow guides, which are manufactured as separate parts, and attached to the balance. Calibration of this new flow-through balance demonstrates that it can suitably characterize the load and pressure ranges it was designed for, which provides aero researchers a new tool to directly measure retropropulsion performance of powered descent vehicles. Balances used in NASA’s ground test facilities are typically either single-piece balances or floating-frame balances. Historically, these two types of balances have generally used different front-end (model) attachments. Single-piece balances generally have a cylindrical front end that is forward of any measuring sections and at a reduced diameter relative to the balance outer diameter. Floating-frame balances generally have front end fits that extend over one or more measuring sections and that engage at the balance outer diameter. Recently, the NFMTC fabricated a single-piece balance with a front end fit that is compatible with the hardware used to calibrate floating-frame balances. Calibration results evaluating this front end fit will be presented. From a recent survey of angle measurement needs, the development of smaller angle measurement packages was identified as one area of improvement. Micro-electromechanical systems (MEMS) are continually being refined to provide high performance accelerometers that are a fraction of the volume of the quartz flexure based accelerometers that are standard in wind tunnels. A survey of commercial off-the-shelf MEMS accelerometers was conducted, and it identified the Safran Colibrys MS lines to be of adequate performance. Single-axis test boards and tri-axis rigid-flex production boards were designed and fabricated with a volume of approximately .18 cubic inches. The boards were designed to provide all the necessary conditioning for the MEMS accelerometers at levels to meet or exceed all requirements for the MS line sensors. Preliminary testing of these assembled sensor packages has demonstrated acceptable performance for wind-tunnel angle measurement. Several new rotating balances are at various stages of completion for NASA Glenn Research Center’s fan drive rigs. These balances provide direct measurement of thrust and torque of a driven fan or fan section to provide an estimate of fan efficiency and net thrust. Three two-component balances have been recently completed, and one six-component balance is in active development. A custom rotating telemetry system has been developed to support testing with these balances, and the telemetry system is integrated into the forward end of each one. The telemetry system is designed to remove mechanical sliprings by using an optical ethernet-based slipring for data transmission.

Force measurement↗

Surface Gravimetry Using Rover Navigation Systems

This prototype seeks to demonstrate the utility of repurposing a Micro-ElectroMechancical (MEMS) Inertial measurement Unit (IMU) to perform surface gravimetry on a rover. Gravimetry is a common analytical tool used for probing density distributions in the subsurface of a planetary body. Historically, extraterrestrial gravimetry has been confined to orbital platforms. While orbital surveys allow for the construction of global gravity models, the spatial resolution of the data is constrained by the platform’s orbital altitude and high inherent speed. Data collected at or near the surface would increase spatial resolution and allow finer-scale crustal structure to be resolved. To date, there have been only two extraterrestrial surface gravity surveys: the Apollo 17 Traverse Gravimeter Experiment and a survey using the MEMS accelerometers contained within the Curiosity rover’s IMUs. The Curiosity survey highlighted the potential of using MEMS technology to perform planetary gravimetry, albeit with lower sensitivities than traditional surface gravimeters. MEMS accelerometers are included on every rover platform as part of the IMU navigation systems. MEMS accelerometers have low mass, cost, and power requirements while being robust across a range of environments, whereas traditional gravimeters are fragile, costly, and relatively massive (≥8kg versus ≈50g for MEMS IMUs). Thus, the emergence of MEMS gravimeters provides a low-risk and cost-effective method for performing planetary surface gravimetry [3,4]. Here, we present a method to recalibrate the MEMS accelerometers in rover IMUs to collect gravimetric measurements. Such measurements could assist current and future rover missions and support wider efforts to mature MEMS gravimeters.

C S Lawson↗

Measurement and Analysis of the Extreme Physical Shock Environment Experienced by Crane-Mounted Radiation Detection Systems.

Potentially, radiation detectors at ports of entry could be mounted on container gantry crane spreaders to monitor cargo containers entering and leaving the country. These detectors would have to withstand the extreme physical environment experienced by these spreaders during normal operations. Physical shock data from the gable ends of a spreader were recorded during the loading and unloading of a cargo ship with two Lansmont SAVER 9X30 units (with padding) and two PCB Piezotronics model 340A50 accelerometers (hard mounted). Physical shocks in the form of rapid acceleration were observed in all accelerometer units with values ranging from 0.20 g’s to 199.99 g’s. The majority of the shocks for all the Lansmont and PCB accelerometers were below 50 g’s. The Lansmont recorded mean shocks of 21.83 ± 13.62 g’s and 24.78 ± 11.49 g’s while the PCB accelerometers experienced mean shocks of 34.39 ± 25.51 g’s and 41.77 ± 22.68 g’s for the landside and waterside units, respectively. Encased detector units with external padding should be designed to withstand at least 200 g’s of acceleration without padding and typical shocks of 30 g’s with padding for mounting on a spreader.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Release Report Source Physics Experiments 5 and 6 (SPE-5 and SPE-6), Nevada National Security Site

The fifth Source Physics Experiment test (SPE-5) was conducted in Nevada on April 26, 2016, at 20:49:00 Coordinated Universal Time (UTC). The explosive source was 4,288.7 kilograms (kg) of polymer-bonded explosive (PBXN) –110, equivalent to 5,035 kg of trinitrotoluene (TNT) detonated at a depth of 76.5 meters (m). The sixth Source Physics Experiment test (SPE-6) was conducted in Nevada on October 12, 2016 at 18:36:00 UTC. The explosive source was 1,982.2 kg of PBXC-141, equivalent to 2,240.2 kg of TNT detonated at the depth of 31.4 m. Both tests were recorded by an extensive set of instrumentation that includes sensors both at near-field (less than 100 m) and far-field (100 m or greater) distances. The near-field instruments consisted of three-component accelerometers installed at various depths ranging from 4 to 99 m below ground surface in boreholes positioned around the shot, and a set of single-component vertical accelerometers on the surface. The far-field network was composed of a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, and three-component accelerometers at distances of 100 m to 400 kilometers. In addition, both explosions were recorded in a temporary array of 996 geophones arranged in a densely spaced grid pattern (“large N”). This report coincides with the release of these data for analysts and organizations that are not participants in this program. This report describes the fifth and sixth Source Physics Experiment tests and the various types of near-field and far-field data that are available.

58 GEOSCIENCES↗

Interferometric Measurement of Acceleration at Relativistic Speeds

We show that an interferometer moving at a relativistic speed relative to a point source of light offers a sensitive probe of acceleration. Such an accelerometer contains no moving parts, and is thus more robust than conventional “mass-on-a-spring” accelerometers. In an interstellar mission to Alpha Centauri, such an accelerometer could be used to measure the masses of exoplanets and their host stars as well as test theories of modified gravity.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-intrusive Shock Measurements Using Laser Doppler Vibrometers

Stud mount accelerometers are widely used by the aerospace industry to measure shock environments during hardware qualification. The commonly used contact-based sensors, however, interfere with the shock waves and distort the acquired signature, which is a concern not actively discussed in the community. To alleviate these interference issues, engineers at the Jet Propulsion Laboratory are investigating the use of non-intrusive sensors, specifically Laser Doppler Vibrometers, as alternatives to the stud mounted accelerometers. This paper will describe shock simulation tests completed at the Jet Propulsion Laboratory, compare the measurements from stud mounted accelerometers and Laser Doppler Vibrometers, and discuss the advantages and disadvantages of introducing Laser Doppler Vibrometers as alternative sensors for measuring shock environments.

shock testing↗

Development of the NASA Mini/MEMS Tri-Axis Sensor System

This manuscript details the development of a reduced volume attitude sensor developed at NASA. This new sensor uses MEMs based accelerometers to reduce the volume when compared to current sensors used in wind-tunnel models. Our team has designed, fabricated, and evaluated the Mini/MEMs Tri-Axis Sensor System (MTASS). The current MTASS design accommodates three tactical-grade accelerometers into the volume of a single axis accelerometer that is currently used. This arrangement allows for the estimation of model pitch and roll angles. Static testing of the MTASS demonstrated angle accuracies within ±0.01° for both pitch and roll.

angle measurement↗

Development of the NASA Mini/MEMS Tri-Axis Sensor System

This manuscript details the development of a reduced volume attitude sensor developed at NASA. This new sensor uses MEMs based accelerometers to reduce the volume when compared to current sensors used in wind-tunnel models. Our team has designed, fabricated, and evaluated the Mini/MEMs Tri-Axis Sensor System (MTASS). The current MTASS design accommodates three tactical-grade accelerometers into the volume of a single axis accelerometer that is currently used. This arrangement allows for the estimation of model pitch and roll angles. Static testing of the MTASS demonstrated angle accuracies within ±0.01° for both pitch and roll.

angle measurement↗

A Chip-Scale Oscillation-Mode Optomechanical Inertial Sensor Near the Thermodynamical Limits

Modern navigation systems integrate the global positioning system (GPS) with an inertial navigation system (INS), which complement each other for correct attitude and velocity determination. Here, the core of the INS integrates accelerometers and gyroscopes used to measure forces and angular rate in the vehicular inertial reference frame. With the help of gyroscopes and by integrating the acceleration to compute velocity and distance, precision and compact accelerometers with sufficient accuracy can provide small–error location determination. Solid–state implementations, through coherent readout, can provide a platform for high performance acceleration detection. In contrast to prior accelerometers using piezoelectric or capacitive readout techniques, optical readout provides narrow–linewidth high–sensitivity laser detection along with low–noise resonant optomechanical transduction near the thermodynamical limits. Here an optomechanical inertial sensor with an 8.2 µg Hz –1/2 velocity random walk (VRW) at an acquisition rate of 100 Hz and 50.9 µg bias instability is demonstrated, suitable for applications, such as, inertial navigation, inclination sensing, platform stabilization, and/or wearable device motion detection. Driven into optomechanical sustained–oscillation, the slot photonic crystal cavity provides radio–frequency readout of the optically–driven transduction with an enhanced 625 µg Hz –1 sensitivity. Measuring the optomechanically–stiffened oscillation shift, instead of the optical transmission shift, provides a 220× VRW enhancement over pre–oscillation mode detection.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development, Testing, and Validation of Fabry-Pérot Cavity Acoustic Sensors for Microreactor Applications

Nuclear microreactors are a unique reactor design which may allow for the nuclear energy industry to tap into unconventional markets, and their modularity presents some advantages over larger, conventional reactor designs. For nuclear microreactors to be economically viable, on-line structural health monitoring may be necessary to reduce operation and maintenance costs with lower power production. Optical fiber sensors, and specifically optical Fabry-Pérot cavities (FPCs), may present the opportunity to monitor vibrational frequencies of microreactor components during operation, enabling identification of the location and severity of potential damage. In this work, FPCs were designed and fabricated with materials which may be able to survive in the extremely harsh environment of nuclear microreactors. The FPCs were bonded to metal test specimens to monitor their vibrational frequencies, along with a reference piezoelectric accelerometer. Euler-Bernoulli theory was used to calculate the fundamental modes and mode-shapes to compare with experimentally measured frequency spectra. The peak frequencies detected with the FPC and piezoelectric accelerometer, and theoretical modes, all agreed well for the first four fundamental modes (within 5%). Furthermore, when the FPC and accelerometer were co-located on the test specimen, their peak frequencies all agreed within 1%.

Birri, Tony↗

Data Release Report for Source Physics Experiment 1 (SPE-1), Nevada National Security Site

The first Source Physics Experiment shot (SPE-1) was conducted in May 2011. The explosive source was a ~100-kilogram TNT-equivalent chemical set at a depth of 60 meters. It was recorded by an extensive set of instrumentation that includes sensors both at near-field (less than 100 meters) and far-field (more than 100 meters) distances. The near-field instruments consisted of three-component accelerometers deployed in boreholes around the shot and a set of singlecomponent vertical accelerometers on the surface. The far-field network comprised a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, three-component accelerometers, and rotational seismometers at distances of 100 meters to 25 kilometers. This report coincides with the release of these data for analysts and organizations that are not participants in this program. This report describes the first Source Physics Experiment and the various types of near-field and far-field data that are available.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Fuel assembly shaker and truck test simulation

This study continues the modeling support of the SNL shaker table task from 2013 and includes analysis of the SNL 2014 truck test campaign. Detailed finite element models of the fuel assembly surrogate used by SNL during testing form the basis of the modeling effort. Additional analysis was performed to characterize and filter the accelerometer data collected during the SNL testing. The detailed fuel assembly finite element model was modified to improve the performance and accuracy of the original surrogate fuel assembly model in an attempt to achieve a closer agreement with the low strains measured during testing. The revised model was used to recalculate the shaker table load response from the 2013 test campaign. As it happened, the results remained comparable to the values calculated with the original fuel assembly model. From this it is concluded that the original model was suitable for the task and the improvements to the model were not able to bring the calculated strain values down to the extremely low level recorded during testing. The model needs more precision to calculate strains that are so close to zero. The truck test load case had an even lower magnitude than the shaker table case. Strain gage data from the test was compared directly to locations on the model. Truck test strains were lower than the shaker table case, but the model achieved a better relative agreement of 100-200 microstrains (or 0.0001-0.0002 mm/mm). The truck test data included a number of accelerometers at various locations on the truck bed, surrogate basket, and surrogate fuel assembly. This set of accelerometers allowed an evaluation of the dynamics of the conveyance system used in testing. It was discovered that the dynamic load transference through the conveyance has a strong frequency-range dependency. This suggests that different conveyance configurations could behave differently and transmit different magnitudes of loads to the fuel even when traveling down the same road at the same speed. It is recommended that the SNL conveyance system used in testing be characterized through modal analysis and frequency response analysis to provide context and assist in the interpretation of the strain data that was collected during the truck test campaign.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data Release Report for Source Physics Experiments 2 and 3 (SPE-2 and SPE-3) Nevada National Security Site

The second Source Physics Experiment shot (SPE-2) was conducted in Nevada on October 25, 2011, at 1900:00.011623 Greenwich Mean Time (GMT). The explosive source was 997 kilograms (kg) trinitrotoluene (TNT) equivalent of sensitized heavy ammonium fuel oil (SHANFO) detonated at a depth of 45.7 meters (m). The third Source Physics Experiment shot (SPE-3) was conducted in Nevada on July 24, 2012, at 1800:00.44835 GMT. The explosive source was 905 kg TNT equivalent of SHANFO detonated at a depth of 45.8 m. Both shots were recorded by an extensive set of instrumentation that includes sensors both at near-field (less than 100 m) and far-field (100 m or greater) distances. The near-field instruments consisted of three-component accelerometers deployed in boreholes at 15, 46, and 55 m depths around the shot and a set of single-component vertical accelerometers on the surface. The far-field network was composed of a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, three-component accelerometers, and rotational seismometers at distances of 100 m to 25 kilometers. This report coincides with the release of these data for analysts and organizations that are not participants in this program. This report describes the second and third Source Physics Experiment shots and the various types of near-field and far-field data that are available.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Data Release Report for Source Physics Experiments 2 and 3 (SPE-2 and SPE-3) Nevada National Security Site

The second Source Physics Experiment shot (SPE-2) was conducted in Nevada on October 25, 2011, at 1900:00.011623 Greenwich Mean Time (GMT). The explosive source was 997 kilograms (kg) trinitrotoluene (TNT) equivalent of sensitized heavy ammonium fuel oil (SHANFO) detonated at a depth of 45.7 meters (m). The third Source Physics Experiment shot (SPE-3) was conducted in Nevada on July 24, 2012, at 1800:00.44835 GMT. The explosive source was 905 kg TNT equivalent of SHANFO detonated at a depth of 45.8 m. Both shots were recorded by an extensive set of instrumentation that includes sensors both at near-field (less than 100 m) and far-field (100 m or greater) distances. The near-field instruments consisted of three-component accelerometers deployed in boreholes at 15, 46, and 55 m depths around the shot and a set of single-component vertical accelerometers on the surface. The far-field network was composed of a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, three-component accelerometers, and rotational seismometers at distances of 100 m to 25 kilometers. This report coincides with the release of these data for analysts and organizations that are not participants in this program. This report describes the second and third Source Physics Experiment shots and the various types of near-field and farfield data that are available.This revised document includes reports on baseline shift corrections for the SPE-2 and SPE-3 shots that were missing from the original January 2015 version.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Data Release Report for Source Physics Experiment 4Prime (SPE-4Prime) Nevada National Security Site (Revision 1)

The fourth test in the Source Physics Experiment series (SPE-4Prime) was conducted at a granite site in Nevada on May 21, 2015, at 18:35:44.000,003,989 ± 20 nanoseconds Coordinated Universal Time. The explosive source was 69.1 kilograms (kg) (including detonator assembly) of Composition C4 plastic explosive (89.14 kg TNT equivalent) detonated at a depth of 87.2 meters (m). The explosion was recorded by an extensive set of instrumentation that includes sensors both at near-field (less than 100 m) and far-field (100 m or greater) distances. The near-field instruments consisted of three-component accelerometers installed at various depths from 7 to 99 m in boreholes positioned around the source hole, and a set of single-component vertical accelerometers on the surface. The far-field network was composed of a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, and three-component accelerometers at distances of 100 m to 25 kilometers. Infrasound data were collected from ground-based sensor arrays at distances out to 5 kilometers. This revised document includes a new Section 3.2.2, which is a discussion of clock timing issues discovered at four far-field stations.

58 GEOSCIENCES↗

Data Release Report for Source Physics Experiment 4Prime (SPE-4Prime) Nevada National Security Site

The fourth test in the Source Physics Experiment series (SPE-4Prime) was conducted at a granite site in Nevada on May 21, 2015, at 18:35:44.000,003,989 ± 20 nanoseconds Coordinated Universal Time. The explosive source was 69.1 kilograms (kg) (including detonator assembly) of Composition C4 plastic explosive (89.14 kg TNT equivalent) detonated at a depth of 87.2 meters (m). The explosion was recorded by an extensive set of instrumentation that includes sensors both at near-field (less than 100 m) and far-field (100 m or greater) distances. The near-field instruments consisted of three-component accelerometers installed at various depths from 7 to 99 m in boreholes positioned around the source hole, and a set of single-component vertical accelerometers on the surface. The far-field network was composed of a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, and three-component accelerometers at distances of 100 m to 25 kilometers. Infrasound data were collected from ground-based sensor arrays at distances out to 5 kilometers.

58 GEOSCIENCES↗

Review of Landscaping Equipment Vibration Risk Exposure, LLNL Site 200 (Various Locations), Whole Body Vibration Seated and Standing Mowers

WBV (Whole-Body Vibration) for operators of seated and standing lawn mowers was conducted during landscape activities from April 2019 through August 2019 at various locations around LLNL Site 200. Mowing is generally performed by each landscaper for 2-3 days every other week with a maximum duration of 3-5 hours each day. On mowing days, other tasks are performed for the remainder of the day that do not expose the worker to WBV such as irrigation, blowing, or sweeping. The mowing terrain at LLNL is variable with typical reported conditions such as gopher holes, exposed tree roots, quick turns, normal and high growth, weeds, and mushy/wet ground that can result in jolts to the mower operator. The Larson Davis HVM200 seat pad with tri-axial accelerometer was used for monitoring workers. For the seated mowers, the HVM200 seat pad with tri-axial accelerometer was placed on the seat between the user and seat pan of the mower. For standing mowers, the seat pad with tri-axial accelerometer was wrapped with Dycem (for seat pad protection) and placed directly on top of the mower deck and underneath the end-user’s right foot. Monitoring for WBV was conducted while operators used different types, makes, and models of mowers. A total of sixteen samples were collected from the operators of seated mower and 6 samples were collected from operators of standing mower. This initial data sampling was part of a discovery phase to identify if WBV exposure met the 2016 ACGIH TLVs (Threshold Limit Values). This initial data identified that workers operating the mowers do not exceed either the TLV or Action Level (AL) for Weighted Acceleration Levels (A(8)) but typically exceed the Vibration Dose Value (VDV) lower boundary for the standing mowers.

59 BASIC BIOLOGICAL SCIENCES↗

TRUST Testing Procedure Documentation

The TRUST testbed was designed and fabricated to conduct vibration testing and validate the behavior of hyper-elastic foams in a pre-loaded condition. The main goals of this testbed design were to ensure symmetry, proper instrumentation alignment and mounting, simplified geometry to make the data analysis validation process more straightforward, and to apply and monitor the applied pre-load. Based off of the test parameters, a shaker system was purchased. The baseplate was designed to mount directly to the bolt holes provided on the top of the shaker table. It was determined that the specimens will be cylindrical and vary in thickness from 2-10mm. The baseplate riser, center-mass, and testbed cap were designed to be cylindrical to make alignment about the center axis more straightforward. It was determined to fabricate the parts previously mentioned using Aluminum 6061-T6 due to its stiffness in order to reduce the likelihood of the stiff material impacting the data being collected for the foam specimens. The design concept used to apply the pre-load to the testbed was a through bolt/nut configuration. A through hole was included in each piece of the testbed, specimens, and instrumentation large enough to allow for 1/8” clearance between the through bolt and each of these pieces. This was imperative to avoid causing friction and complicating the validation model. A load cell was then purchased and used to measure the pre-load being applied to the testbed. It was also required to collect data for 3 axes at 3 different locations 120° apart on the center-mass. This configuration was required to be placed on the cylindrical face and toward the top and bottom of the center-mass. Slots were milled out in the middle of each sensor block with tight tolerances for mounting each of the accelerometers at 120° apart. This same approach was taken to mount 2 accelerometers on the baseplate at 180° apart. Holes were milled out of the corners of each accelerometer mounting slot to relieve the corner and allow for a flat edge at the back of each slot. Sensor blocks were mounted into the center-mass using 6-32 bolts at the required locations. This initial testbed design was fabricated at the TA53 machine shop.

42 ENGINEERING↗