Design of Instrumentation for Noble Gas Transport in LSTL Needed for Model Development

Development of molten salt reactors (MSRs) requires consideration of several physical phenomena that are different from the light water reactor (LWR) experience. While small-scale tests have been performed to understand the behavior of molten salts, the scale-up to larger experiments is an important step in the development of MSR designs. These small-scale experiments have given information on the thermodynamic state of the heat transport fluid and its constituents, thermophysical properties, convective flow, and corrosion. As detailed models have been developed, using these models to simulate larger scale experiments must incorporate physics that becomes important during scale-up, temperature inhomogeneities, complex flow behavior, and two-phase flow. The purpose of the work package has been to link experimental and modeling efforts in the support of licensing development to design and evaluate technologies to mitigate radionuclide release from MSRs. There were two main activities in this work package—one investigating fission product transport into the cover gas and the other on fission gas transport in the molten salt.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Particle physics at accelerators in the United States and Asia

Particle physics experiments in the United States and Asia have greatly contributed to the understanding of elementary particles and their interactions. With the recent discovery of the Higgs boson at CERN, interest in the development of next-generation colliders has been rekindled. A linear electron–positron collider in Japan and a circular collider in China have been proposed for precision studies of the Higgs boson. In addition to the Higgs programme, new accelerator-based long-baseline neutrino mega-facilities are being built in the United States and Japan. Here, we outline the present status of key particle physics programmes at accelerators, and future plans in the United States and Asia that largely complement approaches being explored in the European Strategy for Particle Physics Update. Furthermore, we encourage the pursuit of this global approach, reaching beyond regional boundaries for optimized development and operations of major accelerator facilities worldwide, to ensure an active and productive future of the field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nondestructive Characterization of Antireflective Coatings on PV Modules

Antireflective coatings (ARCs) are used on the vast majority of solar photovoltaic (PV) modules to increase power production. However, ARC longevity can vary from less than 1 to over 15 years depending on coating quality and deployment conditions. A technique that can quantify ARC degradation nondestructively on commercial modules would be useful both for in-field diagnostics and accelerated aging tests. In this article, we demonstrate that accurate measurements of ARC spectral reflectance can be performed using a modified commercially available integrating-sphere probe. The measurement is fast, accurate, nondestructive, and can be performed outdoors in full-sun conditions. We develop an interferometric model that estimates coating porosity, thickness, and fractional area coverage from the measured reflectance spectrum for a uniform single-layer coating. We demonstrate the measurement outdoors on an active PV installation, identify the presence of an ARC, and estimate the properties of the coating.

14 SOLAR ENERGY↗

Novel Temperature Sensors and Wireless Telemetry for Active Condition Monitoring of Advanced Gas Turbines

The objective of the program is to develop and engine test hardware and software technologies that will enable active condition monitoring to be implemented on hot gas path turbine blades in large industrial gas turbines. The specific objectives are (1) to fabricate and install Smart Turbine Blades with thermally sprayed sensors and high temperature wireless telemetry systems in a gas turbine engine, (2) to integrate the component engine test data with remaining useful life (RUL) models and develop an approach for networking the component RUL data with Siemens' Power Diagnostics® engine monitoring system. These significant advances carried out in Phase 1 in temperature wide bandgap telemetry, along with new induced power driver and receiver geometry combined with an innovative approach to transmit digital data wirelessly will enable the opportunity to proceed with more technical innovation. The Phase 2 program focused on validation testing of sensor-wireless telemetry package in spin rig and advanced operation-based assessment (OBA) model utilizing artificial intelligence. Significant efforts were dedicated on the download of the technology onto components to be tested an actual gas turbine engine for full realization of active condition monitoring for Smart Turbine Blades.

03 NATURAL GAS↗

Hybrid Modeling of a Circulating Water Pump Motor

To achieve high capacity factors, the nuclear fleet has relied on labor-intensive and time-consuming operation and preventive maintenance programs for plant systems. Manually performed inspection, calibration, testing, and maintenance of plant assets at periodic frequencies, along with the time-based replacement of assets irrespective of condition, have resulted in a costly, labor-centric business model. Fortunately, there are technologies that can eliminate unnecessary preventive maintenance activities by deploying risk-informed predictive maintenance, enabling the transition to a technology-centric business model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined Optical and Radio-Frequency Perspectives on a Hybrid Cloud-To-Ground Lightning Flash Observed by the FORTE Satellite

In this work, we use the coincident optical and radio-frequency (RF) measurements taken by the Fast On-orbit Recording of Transient Events (FORTE) satellite to shed light on common optical signatures recorded by NASA and NOAA lightning imagers during Cloud-to-Ground (CG) lightning. We build flash cluster data for FORTE using the same techniques as the NASA/NOAA instruments to document the optical/RF evolution of an oceanic hybrid -CG flash. The flash began with strong Very High Frequency (VHF)-band emission from a Narrow Bipolar Event (NBE) that initiated a period of normal bilevel intracloud (IC) activity in two vertical layers (8 and 12 km) that lasted for 490 ms. VHF waveforms show step leader activity ahead of the return stroke. All impulsive VHF sources after the stroke come from the lower (8 km) layer. K-changes are noted following the return stroke, but no subsequent strokes are detected. The optical flash began 136 ms after the NBE RF pulse. Twenty-two of the 33 optical groups were dim and occurred during the in-cloud phase of the flash. This activity included both isolated pulses and sustained periods of illumination over tens of milliseconds. Initial cloud pulses accounted for 23% of the total optical radiance from the flash. Illumination during the return stroke contributed 58% of the total radiance, and the K-changes and cloud pulses after the stroke supplied the remaining 19%. These results highlight the benefit of having RF alongside optical lightning measurements for clarifying signatures in the optical data and providing information on their physical origins.

54 ENVIRONMENTAL SCIENCES↗

Long-exposure NuSTAR constraints on decaying dark matter in the Galactic halo

Here, we present two complementary NuSTAR x-ray searches for keV-scale dark matter decaying to monoenergetic photons in the Milky Way halo. In the first, we utilize the known intensity pattern of unfocused stray light across the detector planes—the dominant source of photons from diffuse sources—to separate astrophysical emission from internal instrument backgrounds using ~7- Ms/detector deep blank-sky exposures. In the second, we present an updated parametric model of the full NuSTAR instrument background, allowing us to leverage the statistical power of an independent ~20-Ms/detector stacked exposures spread across the sky. Finding no evidence of anomalous x-ray lines using either method, we set limits on the active-sterile mixing angle sin 2 ⁡(2⁢θ) for sterile-neutrino masses 6–40 keV. The first key result is that we strongly disfavor a ~7-keV sterile neutrino decaying into a 3.5-keV photon. The second is that we derive leading limits on sterile neutrinos with masses ~15–18 keV and ~25–40 keV, reaching or extending below the big bang nucleosynthesis limit. In combination with previous results, the parameter space for the neutrino minimal standard model is now nearly closed.

79 ASTRONOMY AND ASTROPHYSICS↗

Moving toward automated µFTIR spectra matching for microplastic identification: addressing false identifications and improving accuracy

Abstract Infrared spectroscopy is a widely used tool for studying microplastics and identifying microparticles. Researchers rely on spectral libraries to differentiate between synthetic and natural materials. Unfortunately, spectral library matching is not perfect, and best practices require researchers to use time consuming, manual peak matching to assess spectral matches. Moving toward automated matching requires increased confidence in the matching process. Using spectra matching software may increase the efficiency of particle identification, however some matching strategies may confuse natural materials such as cotton, silk, and plant matter with common classes of synthetics such as polyesters and polyamides. In this experiment, we prepared 22 pristine sample materials from natural and synthetic sources and measured micro-Fourier transform infrared (µFTIR) spectra in transmission mode for each sample using a Thermo Nicolet iN10 MX instrument. The collected spectra were then input into two spectral library matching systems (Omnic Picta and Open Specy), using a total of five identification routines. Next, we placed a subset of four pristine microplastic materials in a biologically active river system for two weeks to simulate environmental samples. These simulated environmental samples were processed using 10% hydrogen peroxide for 24 h to remove organic contamination and then identified using the strongest performing library. We found that libraries with fewer sample spectra produced lower correlation matches and that using derivative correction greatly reduced the number of inaccuracies in identifying materials as either natural or synthetic. We also found that environmental fouling reduced the correlation value of library matches when compared to pristine particles, however the effect was not consistent across the four materials tested. Overall, we found that the accuracy of automated library matching in the tested systems and processing routines varied from 64.1 to 98.0% for distinguishing between natural and synthetic materials, and that a high Hit Quality Index (HQI) did not always correlate with accuracy. These results are important for the microplastic field, demonstrating a need to rigorously test spectral libraries and processing routines with known materials to ensure identification accuracy.

Kozloski, Rachel↗

Benchtop Autonomous Electrochemical Characterization System for Combinatorial Thin-Film Solid Oxide Electrodes

The design of materials for electrochemical energy conversion is complicated by a vast search space of candidate materials and multifaceted property requirements: multicarrier conductivity, stability, and catalytic activity are all necessary but rarely intersect. Although self-driving laboratories are rapidly rising to address such material optimization problems, the required infrastructure for integrated, large-scale robotic facilities can be cost-prohibitive. Here we develop and evaluate a closed-loop measurement system for efficient screening of proton-conducting oxide electrodes for ceramic fuel cells and electrolyzers, building on top of an existing benchtop instrument and integrating techniques for rapid impedance measurement and automated analysis. This system exemplifies a “minimum viable” self-driving implementation that can deliver substantial benefits with relatively simple infrastructure. Combinatorial thin-film microelectrode libraries are characterized with a recently developed joint time-domain and frequency-domain impedance measurement technique, which provides an order-of-magnitude acceleration relative to conventional impedance spectroscopy. The distribution of relaxation times is extracted from impedance data and analyzed without human intervention. These results feed an active learning and Bayesian optimization process that learns to predict electrochemical impedance as a function of material composition, measurement temperature, oxygen partial pressure, and electrical bias, which further reduces the screening time by tenfold with optimized experimental sequences. We apply this system to Ba⁡(Co,Fe,Zr,Y)⁢O 3−𝛿 combinatorial libraries and evaluate its effectiveness for learning material property trends and optimizing expensive-to-evaluate properties such as activation energy. This offers insights into key methodological aspects of practical autonomous experimentation, including surrogate model validation, cost-aware acquisition functions, and high-throughput data interpretation. Our results demonstrate the efficacy of the system for rapidly gathering information, but also highlight real-world experimental challenges of thin-film degradation and numerical instability in surrogate models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Sensors and Instrumentation (ASI) Program Plan. Nuclear Energy Enabling Technologies (NEET)

The U.S. Department of Energy Office of Nuclear Energy (DOE-NE) sponsors a crosscutting technology development (CTD) program addressing common instrumentation & controls (I&C) needs in all DOE-NE sponsored programs. In 2012, DOE-NE initiated the Nuclear Energy Enabling Technology (NEET) Program to conduct research, development, and demonstration (RD&D) in crosscutting technologies that directly support and enable the development of existing, new and advanced reactor designs, and fuel cycle technologies. These technologies will advance the state of nuclear technology, improve its competitiveness, and promote continued contribution to meeting our Nation’s energy and environmental challenges. The NEET Program has spurred innovation in the field of sensors and instrumentation, advanced methods for manufacturing, and cyber security. The Advanced Sensors and Instrumentation (ASI) program is one element of the NEET CTD that has spurred innovation in the measurement science field by funding research on sensors, instrumentation and controls, communication, and advanced analytics that measure system parameters, gauge component control input, and provide power plant owners and operators critical awareness so they can plan and safely manage operational evolutions. The NEET ASI Program has carried out research and development (R&D) required to develop and deploy innovative and advanced sensors, and instrumentation and control capabilities for current and future nuclear energy systems, and to enable the advanced technologies essential to NE’s R&D efforts needed to realize mission goals. The concept of technology readiness assessment is helpful for the classification of instrumentation technology as part of the program strategy. A technology readiness assessment evaluates technology maturity using the Technology Readiness Level (TRL) scale and was pioneered by the National Aeronautics and Space Administration in the 1980s for space technology. It has recently been adopted to advance fuels and materials. The NEET ASI program objective is to mature instruments technology to TRL 6, which is “demonstration of the technology in relevant environment.” While there may be instances in which a different strategy is justified, the aim of the program is to respond to DOE program and stakeholder needs for nuclear instrumentation then hand off the technology after demonstration for integration in a more complex system, for example an irradiation test, experimental loop or a plant component such as the core, primary system or heat exchanger. A mechanism to continue some level of support from NEET ASI during and after the adoption (for example, to maintain fabrication and calibration capabilities) will be defined as the first example of technology hand off comes to fruition. In addition, several paths exist within DOE to complement NEET ASI activities to extend the maturity beyond TRL, for example through GAIN, technology commercialization funding, and small-business programs. Role of NEET ASI CINR projects in the TRL space, and integration with direct funded demonstration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Observation of Plasma-Stimulated Activation of Surface Species Using Multimodal In Situ/Operando Spectroscopy Combining Polarization-Modulation Infrared Reflection-Absorption Spectroscopy, Optical Emission Spectroscopy, and Mass Spectrometry

Nonthermal plasmas (NTPs) produce reactive chemical environments, including electrons, ions, radicals, and vibrationally excited molecules, that can drive chemistry at temperatures at which such species are thermally inaccessible. There has been growing interest in the integration of conventional catalysis with reactive NTPs to promote novel chemical transformations. Unveiling the full potential of plasma-catalytic processes requires a comprehensive understanding of plasma-catalytic synergies, including characterization of plasma-catalytic surface interactions. In this work, we report on a newly designed multimodal spectroscopic instrument combining polarization-modulation infrared reflection-absorption spectroscopy (PM-IRAS), mass spectrometry, and optical emission spectroscopy (OES) for the investigation of plasma–surface interactions such as those found in plasma catalysis. In particular, this tool has been utilized to correlate plasma-phase chemistry with both surface chemistry and gas-phase products in situ (1) during the deposition of carbonaceous surface species via NTP-promoted nonoxidative coupling of methane and (2) during subsequent activation of surface deposits with an atmospheric pressure and temperature argon plasma jet on both nickel (Ni) and silicon dioxide (SiO 2 ) surfaces. For the first time, the activation of carbonaceous surface species by a NTP on Ni and SiO 2 surfaces to form hydrogen gas and C 2 hydrocarbons was directly observed, where both PM-IRAS and OES measurements suggest that they may form through different pathways. Furthermore, this unique tool for studying plasma–surface interactions could enable more rational design of plasma-stimulated catalytic processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Human-in-the-Loop: The Future of Machine Learning in Automated Electron Microscopy

Machine learning (ML) methods are progressively gaining acceptance in the electron microscopy community for de-noising, semantic segmentation, and dimensionality reduction of data post-acquisition. The introduction of the application programming interfaces (APIs) by major instrument manufacturers now allows the deployment of ML workflows in microscopes, not only for data analytics but also for real-time decision-making and feedback for microscope operation. However, the number of use cases for real-time ML remains remarkably small. Furthermore, we discuss some considerations in designing ML-based active experiments and pose that the likely strategy for the next several years will be human-in-the-loop automated experiments (hAE). In this paradigm, the ML learning agent directly controls beam position and image and spectroscopy acquisition functions, and a human operator monitors experiment progression in real and feature space of the system and tunes the policies of the ML agent to steer the experiment toward specific objectives.

47 OTHER INSTRUMENTATION↗

Meteorological Conditions in Urban Sites in Knoxville, USA. 2025

This 2025 dataset, which contains five csv files, reports hourly air temperature, wind speed, solar radiation, incident short wave, reflected short wave, incident long wave, emitted long wave, net radiation, and photosynthetically active radiation (PAR) data measured in urban parks in Knoxville, Tennessee, USA. The sites include Cumberland Estates Park (CEP), Socially Equal Energy Efficient Development (SEEED), West Hills Park (WHP), West View Park (WVP), and Victor Ashe Park (VAP). Air temperature, wind speed, and solar radiation data were obtained from a METER ATMOS 41 All-in-One Weather Station (Pullman, Washington, USA). Incident and emitted radiation (shortwave and longwave) measurements were made using an Apogee (Logan, Utah, USA) net radiometer (Model SN-500-SS). The SQ-521 Full-Spectrum Quantum sensor (Apogee Instruments, Inc) recorded the PAR. The measurement data for all the sites started on January 1, 2025. and all measurement ended on December 31, 2025. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

Salvador, Christian [ORNL] (ORCID:0000000283287777↗

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Active‐Source Seismic Imaging of Fault Re‐Activation and Leakage: An Injection Experiment at the Mt Terri Rock Laboratory, Switzerland

Abstract We conducted a time‐lapse seismic experiment utilizing automated active seismic source and sensor arrays to monitor a reactivated fault within the Opalinus clay formation at the Mont Terri Rock Laboratory (Switzerland), an analog caprock for geologic carbon storage. A series of six brine injections were conducted into the so‐called Main Fault to reactivate it. Seismic instrumentation in five monitoring boreholes on either side of the fault was used to continuously probe changes in P‐wave travel‐times associated with fault displacement and leakage. We performed time‐lapse travel‐time tomography on five hundred sequential data sets; this revealed a zone of decreased P‐wave velocity, up to 16 m/s, during each injection cycle, followed by a velocity increase during shut‐in. These results demonstrate varying elastic property perturbations, both spatially and temporally, along the fault plane during reactivation. We then interpreted these velocity changes in terms of fault dilation induced by pressurized fluids along the fault.

58 GEOSCIENCES↗

A new algorithm for estimating radioxenon concentrations

A new algorithm (Xcounts) is introduced for estimating the activity concentrations of the xenon isotopes 131m Xe, 133m Xe, 133 Xe, and 135 Xe using beta-gamma coincidence data. The algorithm simultaneously estimates the decay counts associated with the four xenon isotopes, background, and radon in contrast to the net-counts method that uses sequential residual removal to account for background and interreferences. Calibration data for background counts are determined from gas-background measurements and simulation. In Xcounts, the false positive count rates for 131m Xe and 133m Xe are lower than the false positive rates for 133 Xe and 135 Xe. This algorithm appears to reliably detect the metastable isotopes at lower activity levels than the net-counts method and have similar performance for the other isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗