Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Photon Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

XAFS Study of Epitaxial Co[subscript x]Ti[subscript 1-x]O[subscript 2-x] Anatase

Co doped TiO{sub 2}-anatase is a promising candidate for a room-temperature ferromagnetic semiconductor. XAFS measurements have been used to investigate the local Co environment and Co valence for several Co-anatase films. The samples were grown on LaAlO{sub 3} (001) by oxygen plasma assisted molecular beam epitaxy and on SrTiO{sub 3} by atomic oxygen assisted MBE. Co concentrations were about 5%. The measurements were made at the PNC-CAT bending magnet and undulator beamlines at the Advanced Photon Source. For the films on LaAlO{sub 3}, the near edge clearly shows the presence of only Co(2+), and no evidence for metallic Co, while the films on SrTiO{sub 3} showed significant metallic Co. Analysis of the extended fine structure for the LaAlO{sub 3} films finds that the Co substitutes for Ti with some distortion of the lattice. Both in-plane and out-of-plane Co-O bonds are expanded from the Ti-O bonds in anatase. The in-plane bonds are expanded approximately twice as much. A deficit in the oxygen coordination number suggests a correlation of oxygen vacancies with Co sites.

36 MATERIALS SCIENCE↗

X-ray characterization of low-thermal conductivity thin-film materials.

X-ray diffraction and imaging techniques at the Advanced Photon Source (APS) have been used to characterize PbSe/MoSe{sub 2} and PbSe/WSe{sub 2} thin films and multilayers. Diffraction measurements with area detectors were made to demonstrate the nanoscale coherence size of the layers both in-plane and perpendicular to the surface. Higher-resolution diffraction measurements that exploit the tunability of synchrotron radiation for anomalous scattering contrast have been used to accurately determine layer spacings in these multilayers. We also discuss opportunities in other new and emerging x-ray techniques, such as time-resolved studies during growth or processing, and present x-ray imaging capabilities that can be used to investigate thermoelectric thin-film materials.

43 PARTICLE ACCELERATORS↗

Study of precision weak-link stage systems with large travel range and sub-nanometer-scale resolution

To use x-ray optics with nanometer resolution limit, scanning x-ray nanoprobes with corresponding mechanical positioning capability need to be designed. In particular, positioning stages with both sub-nanometer resolution and a positioning/scanning range of several millimeters are required. Based on our design of precision weak-link stages with interferometric encoders for the Center for Nanoscale Materials (CNM) hard x-ray nanoprobe at the Advanced Photon Source (APS) Sector 26, we have developed a new two-dimensional (2-D) weak-link stage system for nanopositioning of a specimen holder. This system provides sub-nanometer resolution, coupled with sub-nanometer metrology at a travel range of several millimeters. The 2-D weak-link stage system is designed with high structure stiffness using laminar overconstrained weak-link mechanisms [4-6]. In this paper we present the study of a linear precision weak-link stage system with sub-centimeter travel range and sub-nanometer positioning resolution. Design of a rotary weak-link stage system with 10-nrad resolution and 10-degree-level travel range is also discussed in this paper.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cryogenic performance of a cryocooler-cooled superconducting undulator

A cryocooler-cooled superconducting undulator has been installed and operated with beam at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The device consists of a dual-core 42-pole magnet structure that is cooled to 4.2 K with a system of four cryocoolers operating in a zero-boil-off configuration. This effort represents the culmination of a development program to establish concept feasibility and evaluate cryostat design and cryocooler-based refrigeration. Cryostat performance is described including cool-down/warm-up, steady-state operation, cooling margin, and the impact of beam during operation in the APS storage ring. Plans for future devices with longer magnets, which will incorporate lessons learned from the development program, are also discussed.

43 PARTICLE ACCELERATORS↗

Note: Loading method of molecular fluorine using x-ray induced chemistry

We have successfully loaded molecular fluorine into a diamond anvil cell at high pressure using the synchrotron x-ray induced decomposition of perfluorohexane (C{sub 6}F{sub 14}). “White” x-ray radiation from the Advanced Photon Source was used to initiate the chemical decomposition of C{sub 6}F{sub 14}, which resulted in the in situ production of F{sub 2} as verified via Raman spectroscopy. Due to the toxic nature of fluorine, this method will offer significant advantages in the ability to easily load a relatively nontoxic and inert substance into a chamber (such as a diamond anvil cell) that, when sealed with other reactants and irradiate with hard x-rays (>7 keV), releases highly reactive and toxic fluorine into the sample/reaction chamber to enable novel chemical synthesis under isolated and/or extreme conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observations on COTR due to the Microbunching Instability in Compressed Beams

The observations of the strong enhancements of the optical transition radiation (OTR) signal observed after bunch compression of photocathode beams in the Advanced Photon Source (APS) linac chicane continue to be of interest. These effects have been attributed to a microbunching instability. Recent tests with an Oriel spectrometer with ICCD readout have extended our COTR spectral studies. In this case we used a microchannel plate image intensifier with a GaAs photocathode to explore the NIR regime out to 880 nm. We report for the first time an {approx}40% intensity modulation of {approx}25-nm period throughout the observed broadband COTR spectra for some localized spatial structures. In addition, the observation of a ring-like COTR image structure in x-y space for a mismatched beam at 355 MeV and a COTR mitigation concept is presented and discussed.

43 PARTICLE ACCELERATORS↗

The inverse problem of bimorph mirror tuning on a beamline

One of the challenges of tuning bimorph mirrors with many electrodes is that the calculated focusing voltages can be different by more than the safety limit (such as 500 V for the mirrors used at 17-ID at the Advanced Photon Source) between adjacent electrodes. A study of this problem at 17-ID revealed that the inverse problem of the tuning in situ, using X-rays, became ill-conditioned when the number of electrodes was large and the calculated focusing voltages were contaminated with measurement errors. Increasing the number of beamlets during the tuning could reduce the matrix condition number in the problem, but obtaining voltages with variation below the safety limit was still not always guaranteed and multiple iterations of tuning were often required. Applying Tikhonov regularization and using the L-curve criterion for the determination of the regularization parameter made it straightforward to obtain focusing voltages with well behaved variations. Some characteristics of the tuning results obtained using Tikhonov regularization are given in this paper.

43 PARTICLE ACCELERATORS↗

Imaging of cochlear tissue with a grating interferometer and hard X-rays

This article addresses an important current development in medical and biological imaging: the possibility of imaging soft tissue at resolutions in the micron range using hard X-rays. Challenging environments, including the cochlea, require the imaging of soft tissue structure surrounded by bone. We demonstrate that cochlear soft tissue structures can be imaged with hard X-ray phase contrast. Furthermore, we show that only a thin slice of the tissue is required to introduce a large phase shift. It is likely that the phase contrast image of the soft tissue structures is sufficient to image the structures even if surrounded by bone. For the present set of experiments, structures with low-absorption contrast have been visualized using in-line phase contrast imaging and a grating interferometer. The experiments have been performed at the Advanced Photon Source at Argonne National Laboratories, a third generation source of synchrotron radiation. The source provides highly coherent X-ray radiation with high-photon flux (>10{sup 12} photons/s) at high-photon energies (5-70 keV). Radiographic and light microscopy images of the gerbil cochlear slice samples were compared. It has been determined that a 20-{micro}m thick tissue slice induces a phase shift between 1/3{pi} and 2/3{pi}.

43 PARTICLE ACCELERATORS↗

Some aspects of achieving an ultimate accuracy during insertion device magnetic measurements by a Hall probe

An extensive test of a new Senis 2-axis Hall probe was done at the Advanced Photon Source using the Undulator A device and calibration system. This new probe has clear advantages compared with previously used Bell and Sentron Hall probes: very stable zero offset (less than the noise of 0.026 G) and compensated planar Hall effect. It can be used with proper calibration even for first and second field integral measurements. A comparison with reference measurements by long stretched coil shows that the difference in the first field integral measurement results for a 2.4-m-long Undulator A device is between 17 G cm for the best of four Hall probes used for the test and 51 G cm for the worst of them for all gap ranges from 10.5 mm to 150 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Structure of Yttrialite and Its Identification Using Laboratory and Synchrotron-Based Powder X-Ray Diffraction

A highly crystalline sample of the impurity stabilized phase y-Y{sub 2}Si{sub 2}O{sub 7}, generally known as yttrialite, has been formed from the melt of a glass with a nominal composition of 62(SiO{sub 2})-10(Al{sub 2}O{sub 3})-28(Y{sub 2}O{sub 3}) mol%. Powder X-ray diffraction patterns were collected using in-house instrumentation and the 11-BM diffractometer at the Advanced Photon Source, Argonne National Laboratory, Argonne, IL. Rietveld refinements were carried out on the patterns using two structural models. On patterns collected using in-house instrumentation the correct structure assignment was difficult to determine; however, the extremely high-quality data afforded by the 11-BM instrument showed conclusively that the sample was found to crystallize in the monoclinic system (SG=P2{sub 1}/m) with lattice parameters a=5.03032(6), b=8.06892(6), c=7.33620(6) {angstrom}, and {beta} = 108.673(1). Furthermore, simulations have shown that it is likely that this structure model can be used to describe natural yttrialite or yttrialite that is formed at low temperatures, though the possibility that such materials are paracrystalline is also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Management of metadata and automation for mail-in measurements with the APS 11-BM high throughput, high-resolution synchrotron powder diffractometer.

A high-resolution and high-throughput synchrotron powder diffractometer has been automated for use with samples that are mailed in by Advanced Photon Source users. Implementation of a relational database with web interfaces for both outside users and beamline staff, which is integrated into the facility-wide proposal and safety system, allows all aspects of beamline management to be integrated. This system permits users to request kits for mounting samples, to provide sample safety information, to obtain their collected data and to provide usage information upon project completion in a quick and simple manner. Beamline staff use a separate interface to note receipt of samples, schedule and collect diffraction data, post-process and quality-check data, and dispose of samples. The design of the software and database are discussed in detail.

43 PARTICLE ACCELERATORS↗

Microstructural transformations and kinetics of high-temperature heterogeneous gasless reactions by high-speed x-ray phase-contrast imaging

Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 {mu}s exposure and spatial resolution of 10 {mu}m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include processes such as the initiation of nucleated melting and other physical phenomena that provide insight into the mixing of reactants and subsequent reaction. Through the use of this imaging technique and future optimization in the imaging process, a model for accurately identifying kinetics of chemical reactions, both spatially and temporally, is also proposed.

36 MATERIALS SCIENCE↗

High-energy x-ray scattering quantification of in-situ-loading-related strain gradients spanning the dentinoenamel junction (DEJ) in bovine tooth specimens.

High energy X-ray scattering (80.7keV photons) at station 1-ID of the Advanced Photon Source quantified internal strains as a function of applied stress in mature bovine tooth. These strains were mapped from dentin through the dentinoenamel junction (DEJ) into enamel as a function of applied compressive stress in two small parallelepiped specimens. One specimen was loaded perpendicular to the DEJ and the second parallel to the DEJ. Internal strains in enamel and dentin increased and, as expected from the relative values of the Young's modulus, the observed strains were much higher in dentin than in enamel. Large strain gradients were observed across the DEJ, and the data suggest that the mantle dentin-DEJ-aprismatic enamel structure may shield the near-surface volume of the enamel from large strains. In the enamel, drops in internal strain for applied stresses above 40MPa also suggest that this structure had cracked.

43 PARTICLE ACCELERATORS↗

Confocal Microscope Alignment of Nanocrystals for Coherent Diffraction Imaging

We have installed and tested an Olympus LEXT confocal microscope at the 34-ID-C beamline of the Advanced Photon Source (APS). The beamline is for Coherent X-ray Diffraction (CXD) experiments in which a nanometre-sized crystal is aligned inside a focussed X-ray beam. The microscope was required for three-dimensional (3D) sample alignment to get around sphere-of-confusion issues when locating Bragg peaks in reciprocal space. In this way, and by use of strategic sample preparations, we have succeeded in measuring six Bragg peaks from a single 200 nm gold crystal and obtained six projections of its internal displacement field. This enables the clear identification of stacking-fault bands within the crystal. The confocal alignment method will allow a full determination of the strain tensor provided three or more Bragg reflections from the same crystal are found.

43 PARTICLE ACCELERATORS↗

Crystal quality analysis and improvement using x-ray topography.

The Topography X-ray Laboratory of the Advanced Photon Source (APS) at Argonne National Laboratory operates as a collaborative effort with APS users to produce high performance crystals for APS X-ray beamline experiments. For many years the topography laboratory has worked closely with an on-site optics shop to help ensure the production of crystals with the highest quality, most stress-free surface finish possible. It has been instrumental in evaluating and refining methods used to produce high quality crystals. Topographical analysis has shown to be an effective method to quantify and determine the distribution of stresses, to help identify methods that would mitigate the stresses and improve the Rocking curve, and to create CCD images of the crystal. This paper describes the topography process and offers methods for reducing crystal stresses in order to substantially improve the crystal optics.

43 PARTICLE ACCELERATORS↗

Discrimination and quantification of implanted solar wind in Genesis collector shards using grazing incidence synchrotron x-ray techniques: New detector initial results

Accurate knowledge of the composition of the Sun provides a baseline, which allows an understanding of how the solar system has evolved over time and how solar processes and solar wind mechanics behave. Unfortunately, the errors in photospheric abundances are too large for many planetary science problems and this hampers our understanding of these different processes. Analyses of solar wind implanted in meteorites or lunar soils have provided more precise data [e.g. 1 and references therein] but the extent to which alteration processes on these bodies complicate such information is only now being determined. Therefore, in order to obtain pristine solar wind samples, NASA developed and launched the Genesis Discovery Mission. Unfortunately, the probe crash-landed shattering the 300 collector plates into 15,000+ pieces complicating the analysis and necessitating the development of new analytical techniques and equipment. Thus, shards from the Genesis collector array and their appropriate flight spares are currently being characterized via grazing-incidence synchrotron x-ray techniques at the Advanced Photon Source at Argonne National Laboratory. The goals are (1) determine solar wind fluences of the elements Ca-Ge by grazing-incidence angle-resolved x-ray fluorescence (XRF) and x-ray reflectivity, (2) improve data reduction via the development of XRF spectral deconvolution routines and develop modeling algorithms for reflectivity and fluorescence yield analysis in order to determine element specific depth profiles from which absolute concentration may be extracted and (3) designing and developing a new multi-element silicon multi-channel (SMCD) detector system. These improvements will increase our sensitivity by a factor of three or more, reduce measurement time at a given sensitivity to one-eighth and the minimum detection limit would be reduced by a factor of 3 to {approx}3 x 10{sup 8} atoms/cm{sup 2}.

43 PARTICLE ACCELERATORS↗

Superconducting RF Deflecting Cavity Design and Prototype for Short X-ray Pulse Generation

Deflecting RF cavities are proposed to be used in generating short x-ray pulses (on ~1-picosecond order) at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL)* using a novel scheme by Zholents**. To meet the required deflecting voltage, impedance budget from higher order, lower order and the same order modes (HOM, LOM and SOM) of the APS storage ring, extensive deflecting cavity design studies have been conducted with numerical simulations and cavity prototypes. In this paper, we report recent progress on a single cell S-band (2.8-GHz) superconducting deflecting cavity design with waveguide damping. A copper and a niobium prototype cavity were fabricated and tested, respectively to benchmark the cavity and damping designs. A new damping scheme has been proposed which provides stronger damping to both HOM and LOM by directly coupling to a damping waveguide on the cavity equator.

43 PARTICLE ACCELERATORS↗

The P0 feedback control system blurs the line between IOC and FPGA.

The P0 Feedback system is a new design at the Advanced Photon Source (APS) primarily intended to stabilize a single bunch in order to operate at a higher accumulated charge. The algorithm for this project required a high-speed DSP solution for a single channel that would make adjustments on a turn-by-turn basis. A field programmable gate array (FPGA) solution was selected that not only met the requirements of the project but far exceeded them. By using a single FPGA, we were able to adjust up to 324 bunches on two separate channels with a total computational time of {approx} 6 x 10{sup 9} multiply- accumulate operations per second. The IOC is a Coldfire CPU tightly coupled to the FPGA, providing dedicated control and monitoring of the system through EPICS [1] process variables. One of the benefits of this configuration is having a four-channel scope in the FPGA that can be monitored on a continuous basis.

43 PARTICLE ACCELERATORS↗