Search NASA⌕ Search

SEARCH · Search NASA

Results for “Alpha Particles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Collaborative Research Towards a tonne-scale bolometer-based neutrinoless double beta decay experiment (Final Report)

Cryogenic bolometers are an excellent technology for neutrinoless double beta decay searches owing to their very high energy resolution and potential for high radiopurity. The current most advanced large-scale experiment using these detectors is the Cryogenic Underground Observatory for Rare Events (CUORE). The largest source of background in CUORE is degraded alpha particles, emitted from shallow depths of the detector holders, which can deposit a thermal energy signature similar to neutrinoless double beta decay. To mitigate this background, the CUPID concept (CUORE Upgrade with Particle IDentification) proposes to use scintillating cryogenic detectors. Detecting both the scintillation light and the thermal signal allows discrimination between alpha particle events and beta/gamma events. We report on the design and execution of R&D tests to optimize the design of the single detector module, in particular the scintillation light collection efficiency at cryogenic temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The S{sub E1} factor of the {sup 12}C({alpha},{gamma}){sup 16}O Reaction and the {sup 16}N {beta}-delayed {alpha} Decay

The {sup 12}C({alpha},{gamma}){sup 16}O reaction is of great importance for the understanding the nuclear synthesis and explosion mechanism of the supernova. The cross section at the relevant stellar burning energies, around 300 keV, is dominated by the sub-threshold resonances. The {sup 16}N {beta}-delayed {alpha} decay data provide the most sensitive constrain on this sub-threshold resonance. Using twin-ionization chambers, we have measured the {alpha} particles and {sup 12}C recoil nuclei in coincidence. The spectrum has been fitted together with the published {sup 12}C({alpha},{gamma}){sup 16}O data and the elastic scattering phase shift data using R-matrix. The S{sub E1} factor at 300 keV has been determined as 73{+-}21 keVb.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Elevated Temperature Alpha Spectroscopy with Nickel-Platinum {sup 4}H-SiC Schottky Diodes

In order to protect against the diversion of special nuclear material during pyro-processing of spent nuclear fuel, an online monitoring of the actinide concentrations must be developed. In order to do so, alpha spectroscopy can be employed in order to determine the relative concentrations of various isotopes based on the characteristic alpha spectrum of each isotope of interest. The operating temperatures in the pyro-processing environment are such that high temperature operability of alpha detectors is required. The Idaho National Laboratory (INL) electro-refiner operates at a molten salt temperature of approximately 500 deg. C. The vapor temperature above the molten salt is approximately 100 deg. C. In order to provide reasonably compact online monitoring of the actinide concentrations within the molten salt the detector would be located in this vapor region. The temperature in this location is too high for a commercial silicon detector to operate without serious signal degradation due to thermal noise. As the operating temperature increases, the thermal energy available to the charge carriers within the semiconductor increases. For narrow band-gap semiconductors like silicon, this increase in free charge carriers with increasing temperature leads to unacceptable leakage current at relatively low temperatures when compared with wide band-gap materials. In order to overcome this, a wide band-gap material is employed. An alpha particle sensor utilizing a nickel Schottky barrier {sup 4}HSiC wafer was heated to a temperature of 100 deg. C and an alpha spectrum collected. The performance of the sensor at 100 deg. C was compared to the room temperature performance. Molten salts such as those used in the INL electro-refiner exhibit strong corrosive properties. Any sensor which will be exposed to or submerged in the molten salt must have a ruggedized sensor face capable to withstand the corrosive environment. In the contact design utilized in this paper the Schottky barrier forming metal, nickel, is coated with a thin layer of platinum to serve as a corrosion resistant layer. An additional modification to previous designs was the simplification of the Schottky barrier composition. A Schottky barrier is created when a metal is brought into close physical contact with a semiconductor. To first order, the barrier height of the Schottky barrier is a result of the mismatch between the electron affinity of the semiconductor and the metal work function of the metal. In previous iterations, the high temperature performance of the detectors had been limited by diffusion processes between the various metal layers. In order to reduce the likelihood of such a degradation, the Schottky contact structure was simplified without loss of functionality. By replacing the multiple metal layers with a nickel Schottky forming layer capped with a thin platinum layer, the potential degradation of the Schottky barrier height could be reduced, primarily through the similar Schottky barrier height to nickel formed by platinum with SiC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response to Mortazavi et al. on Detecting Bone-seeking Radionuclides in Brain Tissue

WE DISAGREE with most of the issues raised by Mortazavi et al. (2018), both scientifically and inferentially. Cranial deposition of radium (or any other bone seeker) is not relevant to our evaluation of alpha particle exposure to brain tissue (Ellis et al. 2018). Radiochemical analysis of tissues has demonstrated that radium is deposited in the brain and results in alpha particle exposure to brain tissue (Schlenker et al. 1982). Radiochemical analyses also have confirmed brain depositions for other bone seekers including plutonium (James et al. 2003, 2007), americium (McInroy et al. 1985), and uranium (Avtandilashvili et al. 2015 ; Kathren and Tolmachev 2015), as well as for the more nearly uniformly distributed alpha emitter polonium (Nathwani et al. 2016).

59 BASIC BIOLOGICAL SCIENCES↗

Collisional alpha transport in a weakly non-quasisymmetric stellarator magnetic field</strong

Alpha particle confinement is a serious concern in stellarators and provides strong motivation for optimizing magnetic field configurations. In addition to the collisionless confinement of trapped alphas in stellarators, excessive collisional transport of the trapped alpha particles must be avoided while they tangentially drift due to the magnetic gradient (the ∇B drift).The combination of pitch angle scatter off the background ions and the ∇B drift gives rise to two narrow boundary layers in the trapped region. The first is at the trapped–passing boundary and enables the finite trapped response to be matched to the vanishing passing response of the alphas. The second layer is a region that encompasses the somewhat more deeply trapped alphas with vanishing tangential ∇B drift. Away from (and between) these boundary layers, collisions are ineffective and the alpha ∇B drift simply balances the small radial drift of the trapped alphas. As this balance does not vanish as the trapped–passing boundary is approached, the first collisional boundary layer is necessary and gives rise to $\sqrt{v}$ transport, with v the collision frequency. The vanishing of the tangential drift results in a separate, somewhat wider boundary layer, and significantly stronger superbanana plateau transport that is independent of collisionality. The constraint imposed by the need to avoid significant energy depletion loss in the slowing down tail distribution function sets the allowed departure of a stellarator from an optimal quasisymmetric configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collisional alpha transport in a weakly non-quasisymmetric stellarator magnetic field

Alpha particle confinement is a serious concern in stellarators and provides strong motivation for optimizing magnetic field configurations. In addition to the collisionless confinement of trapped alphas in stellarators, excessive collisional transport of the trapped alpha particles must be avoided while they tangentially drift due to the magnetic gradient (the ∇B drift). The combination of pitch angle scatter off the background ions and the ∇B drift gives rise to two narrow boundary layers in the trapped region. The first is at the trapped-passing boundary and enables the finite trapped response to be matched to the vanishing passing response of the alphas. The second layer is a region that encompasses the somewhat more deeply trapped alphas with vanishing tangential ∇B drift. Away from (and between) these boundary layers, collisions are ineffective and the alpha ∇B drift simply balances the small radial drift of the trapped alphas. As this balance does not vanish as the trapped-passing boundary is approached, the first collisional boundary layer is necessary and gives rise to √ν transport, with ν the collision frequency. The vanishing of the tangential drift results in a separate, somewhat wider boundary layer, and significantly stronger superbanana plateau transport that is independent of collisionality. The constraint imposed by the need to avoid significant energy depletion loss in the slowing down tail distribution function sets the allowed departure of a stellarator from an optimal quasisymmetric configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulations of Alpha Wall Load in ITER (Final Report)

The partially DOE funded International Thermonuclear Experimental Reactor (ITER) will produce massive amounts of energetic charged alpha particles, which are imperfectly confined by a strong magnetic field. The wall of the experiment is designed to withstand an estimated wall load from these fusion alpha particles, but the accuracy of this estimate needs to be improved to avoid potentially catastrophic surprises when the experiment becomes operational. We have added a more accurate, gyro-dynamic model of particle motion to the existing drift-dynamic model in the DELTA5D simulation software used for the project. We have also added the ability to load a detailed engineering model of the wall and use it in the simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron transfer, excitation, and ionization in {alpha}-H collisions studied with a Sturmian basis

Cross sections have been determined for electron transfer, direct excitation, and ionization in collisions between {alpha} particles and H(1s) atoms at {alpha} energies 3 keV-38.4 MeV, extending earlier work [Phys. Rev. A 25, 697 (1982)] restricted to total transfer at 20-200 keV. Transfer as well as excitation cross sections into individual states up to 3d have been determined with several coupled-Sturmian pseudostate bases, and tests of basis sensitivity have been carried out. These and ionization cross sections have been compared with existing experimental and other coupled-state results. Structure is observed in the lower-energy excitation cross sections, which is believed not to be an artifact of the bases used. Ionization and excitation cross sections have also been compared with corresponding Born results at higher energies.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cross Section Measurement for the 95Mo(n, {alpha})92Zr Reaction at 4.0, 5.0 and 6.0 MeV

For the {sup 95}Mo(n, {alpha}){sup 92}Zr reaction cross section, there is only one experimental datum in the MeV neutron energy region with large uncertainty. As a result, very large deviations exist in different evaluated nuclear data libraries. This paper report the measurement of cross sections of the {sup 95}Mo(n, {alpha}){sup 92}Zr reaction at En = 4.0, 5.0 and 6.0 MeV. Experiments were performed at the 4.5 MV Van de Graaff of Peking University, China. A twin gridded ionization chamber was used as alpha particle detector and two large area {sup 95}Mo samples placed back to back were adopted. Fast neutrons were produced through the D(d, n){sup 3}He reaction by using a deuterium gas target. A small {sup 238}U fission chamber was adopted for absolute neutron flux determination and a BF{sub 3} long counter was used for neutron flux monitor. Present experimental data are compared with existing evaluations and measurement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IN-SITU ASSAY OF TRANSURANIC RADIONUCLIDES IN THE VADOSE ZONE USING HIGH-RESOLUTION SPECTRAL GAMMA LOGGING - A HANFORD CASE STUDY

High-resolution spectral gamma logging in steel-cased boreholes is used to detect and quantify transuranic radionuclides in the subsurface. Pu-239, Pu-241, Am-241, and Np-237 are identified based on characteristic decay gammas. Typical minimum detectable levels are on the order of 20 to 40 nCi/g. In intervals of high transuranic concentrations, gamma rays from other sources may complicate analysis and interpretation. Gamma rays detected in the borehole may originate from three sources: decay of the parent transuranic radionuclide or a daughter; alpha interactions; and interactions with neutrons resulting from either spontaneous fission or alpha particle interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Giant Resonances in the Alpha-Nucleus Interaction

Tunneling of alpha particles through the Coulomb barrier for the source {sup 135}Pr nucleus is consecutively considered. The effect of sharp peaks arising in the case of coincidence of the alpha energy with that of a quasistationary state within the barrier is elucidated. Peaks' energy depend on the alpha-nucleus potential. They can give rise to 'anomalous' properties of some neutron resonances. The peaks can also be observed in the incoming alpha-nucleus channel. The method can be applied for solution of the reverse problem of the alpha-nucleus scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Merging of the superbanana plateau and $\sqrt{v}$ transport regimes in nearly quasisymmetric stellarators

We report alpha particle confinement is one of the most demanding issues for stellarators. It now seems clear that it is possible to design optimized stellarators that confine the background plasma at near tokamak radial transport levels. Moreover, adequate collisionless alpha particle confinement is possible in the core of a highly optimized stellarator. Here, the collisional confinement of barely trapped alphas in an optimized stellarator is considered by accounting for the resonance due to the reversal in direction of the drift within a flux surface and investigating the sensitive role of magnetic shear in keeping this resonance close to the passing boundary in some nearly quasisymmetric stellarator configurations. The treatment relies on a narrow collisional boundary layer formulation that combines the responses of both these resonant pitch angle alphas and the remaining barely trapped alphas. A novel merged regime treatment leads to explicit expressions for the energy diffusivity for both superbanana plateau (or resonant plateau) and $\sqrt{v}$ transport in the large aspect ratio limit for a slowing down tail alpha distribution function, where v is the effective pitch angle scattering collision frequency of the trapped alphas off the background ions. Depending on the details of the optimization scheme and the sign of the magnetic shear, modest magnetic shear can be used to reduce superbanana (or resonant) plateau transport to below the $\sqrt{v}$ transport level. In addition, a quasilinear equation retaining spatial diffusion is derived for a general alpha distribution function that allows the radial alpha transport to modify the distribution so it is no longer isotropic in velocity space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear radiation-warning detector that measures impedance

This invention is a nuclear radiation-warning detector that measures impedance of silver-silver halide on an interdigitated electrode to detect light or radiation comprised of alpha particles, beta particles, gamma rays, X rays, and/or neutrons. The detector is comprised of an interdigitated electrode covered by a layer of silver halide. After exposure to alpha particles, beta particles, X rays, gamma rays, neutron radiation, or light, the silver halide is reduced to silver in the presence of a reducing solution. The change from the high electrical resistance (impedance) of silver halide to the low resistance of silver provides the radiation warning that detected radiation levels exceed a predetermined radiation dose threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alpha Decay Chains as Thermal Power Sources: Analysis and Applications for RTGs

Radioactive sources can provide power in remote and environmentally harsh locations such as the arctic or space. The generators powered by such sources are rugged and can withstand extreme temperatures, lack of sunlight, and require no human intervention for multiple years. Radioisotopes are used in thermoelectric generators to provide power at remote sites and deep in space. Isotopes like Pu-238, Cm-244, and Am-241 are used in these generators by NASA for power in space probes and spacecrafts. These power sources deliver a steady supply of energy over extended periods of time. Alpha particles created during decay do not travel far in a material. Their kinetic energy is transferred to heat that we can then convert into energy. Unlike beta and gamma decay, the slower-moving alpha particles stop in the material, making their energy available for use. Energy from these natural decay processes provides a reliable source of power. Spontaneous fission is rare and unreliable, and unlike induced fission processes, alpha decay occurs naturally and does not require external management or ignition. The ideal properties of an isotope for use as a power source depend upon the intended use. For use in an Arctic research base over a period of several years, but less than a decade, an isotope that provides high power output over a shorter lifespan may be the most suitable option. Whereas, for deep space missions where a consistent power source for decades or perhaps more than 100 years is needed that would require a very different isotope. One with a much longer half-life that would provide consistent power throughout that time and survive in that state in for these extended periods of time. These examples represent two extreme sides in terms of time frames. By analyzing the power produced by different radioactive decay processes over time, we can evaluate the suitability of various isotope decay chains for specific uses. Some unstable isotopes undergo a series of radioactive decays, transforming into different isotopes at each step and resulting in a stable isotope. The lists of isotopes in these decay processes are known as decay chains. Some of these chains, illustrated in the figures below, are currently being investigated for use in radioisotope thermoelectric generators (RTGs) designed for a range of operational durations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characteristics of a RF-Driven Ion Source for a Neutron Generator Used For Associated Particle Imaging

We present recent work on a prototype compact neutron generator for associated particle imaging (API). API uses alpha particles that are produced simultaneously with neutrons in the deuterium-tritium (2D(3T,n)4 alpha) fusion reaction to determine the direction of the neutrons upon exiting the reaction. This method determines the spatial position of each neutron interaction and requires the neutrons to be generated from a small spot in order to achieve high spatial resolution. The ion source for API is designed to produce a focused ion beam with a beam spot diameter of 1-mm or less on the target. We use an axial type neutron generator with a predicted neutron yield of 108 n/s for a 50 muA D/T ion beam current accelerated to 80 kV. The generator utilizes a RF planar spiral antenna at 13.56 MHz to create a highly efficient inductively-coupled plasma at the ion source. Experimental results show that beams with an atomic ion fraction of over 80percent can be obtained while utilizing only 100 watts of RF power in the ion source. A single acceleration gap with a secondary electron suppression electrode is used in the tube. Experimental results, such as the current density, atomic ion fraction, electron temperature, and electron density, from ion source testing will be discussed.

43 PARTICLE ACCELERATORS↗

Defect production in strained p-type Si{sub 1-x}Ge{sub x} by Er implantation

Strained p-Si{sub 1-x}Ge{sub x} (x=5.3%, 10.2%, and 15.4%) was irradiated at room temperature with 160 keV {sup 166}Er{sup 2+} ions to a fluence of 1x10{sup 10} or 3x10{sup 13} Er/cm{sup 2}. The defects induced by ion implantation were investigated experimentally using high-resolution x-ray diffraction, Rutherford backscattering and channeling spectroscopy, and deep level transient spectroscopy. X-ray diffraction indicates that the damage induced by Er implantation produces a slight perpendicular expansion of the SiGe lattice. For all compositions, channeling measurements reveal that Er implantation in p-Si{sub 1-x}Ge{sub x} to a fluence of 3x10{sup 13} Er/cm{sup 2} induces an amorphous region below the Si{sub 1-x}Ge{sub x} surface. Annealing at 850 deg. C for 30 s, results in a reduction in damage density, a relaxation of the implantation-induced perpendicular expansion of the SiGe lattice in the implanted region, while a more pronounced relaxation of the compressive strain SiGe is observed for higher Ge content (x=0.10 and 0.15). On the other hand, for the annealed SiGe samples that were implanted with Er at the fluence of 10{sup 10} Er/cm{sup 2}, the compressive strain in the SiGe layer is nearly completely retained. Deep level transient spectroscopy studies indicate that two prominent defects with discrete energy levels above the valence band are introduced during Er implantation. Their activation energy was found to decrease with increasing Ge content. However, the relatively large local strain induced by high fluence Er implantation reduces the activation energy by 40 meV with respect to the low fluence Er implanted p-Si{sub 1-x}Ge{sub x}. This shift (40 meV) in the activation energy remains constant regardless of the Ge content, suggesting that the Si{sub 1-x}Ge{sub x} layers remained fully strained after Er implantation. The observed defects are further compared to those introduced by alpha particle irradiation and electron beam metal deposition. The results indicate that defects introduced by Er implantation have similar electronic properties as those of defects detected after electron beam deposition and alpha particle irradiation. Therefore, it is concluded that these defects are due to the Er implantation-induced damage and not to the Er species specifically.

36 MATERIALS SCIENCE↗