Search NASA⌕ Search

SEARCH · Search NASA

Results for “Auger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

365 records · Page 21

Impact of carrier wafer on etch rate, selectivity, morphology, and passivation during GaN plasma etching

The choice of carrier wafer was found to significantly influence etch rates, selectivity, and morphology in GaN micropillar etching in a Cl 2 -Ar high-density inductively coupled plasma. 7 × 7 mm 2 GaN on sapphire chips with a plasma-enhanced chemical vapor deposition SiO 2 hard mask was etched on top of 4-in. fused silica, silicon carbide, silicon, sapphire, aluminum nitride, and high purity aluminum carriers. Silicon and silicon carbide carriers reduced GaN:SiO 2 selectivity because incidental SiCl x and CCl x etch products from the carriers attack the SiO 2 mask. Aluminum nitride and high-purity aluminum carriers yielded the highest GaN:SiO 2 selectivities due to the deposition of Al-based etched by-products, while the highest GaN etch rate was achieved using the sapphire carrier since it was the most inert carrier and did not sink any Cl 2 . Overall, results indicate that SiO 2 and Al may be used as passivation materials during GaN etching, as vertical profiles were achieved when SiO 2 or Al is redeposited from the fused silica and aluminum carriers, respectively. Floor pitting, trenching, sidewall roughness, and faceting were all influenced by carrier wafer type and will be discussed.

36 MATERIALS SCIENCE↗

Production of Radiohalogens: Bromine and Astatine for Imaging and Therapy

Over the course of this two year grant, we have developed and optimized new methods for the production of clinical quality 76 Br, 77 Br, and 80m Br at the University of Wisconsin. This includes the synthesis of a novel isotopically enriched cobalt-selenium intermetallic compound, its fabrication into robust cyclotron targets, and the chemical isolation of the resulting bromine radionuclide. Compared with the previous state-of-the-art, these methods demonstrate a six-times larger 76 Br and three-times larger 77 Br production capacity for a 3-hour cyclotron irradiation. Additionally, the cyclotron targets are exceptionally robust to this process, allowing for their reuse for dozens of radiobromine productions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A New Concept for Kilotonne Scale Liquid Argon Time Projection Chambers

We develop a novel Time Projection Chamber (TPC) concept suitable for deployment in kilotonne-scale detectors, with a charge-readout system free from reconstruction ambiguities, and a robust TPC design that reduces high-voltage risks while increasing the coverage of the light-collection system and maximizing the active volume. This novel concept could be used as a far detector module in the Deep Underground Neutrino Experiment (DUNE). For the charge-readout system, we used the charge-collection pixels and associated application-specific integrated circuits currently being developed for the liquid argon (LAr) component of the DUNE Near Detector design, ArgonCube. In addition, we divided the TPC into a number of shorter drift volumes, reducing the total voltage used to drift the ionization electrons, and minimizing the stored energy per TPC. Segmenting the TPC also contains scintillation light, allowing for precise trigger localization and a more expansive light-readout system. Furthermore, the design opens the possibility of replacing or upgrading components. These augmentations could substantially improve the reliability and the sensitivity, particularly for low-energy signals, in comparison to traditional monolithic LArTPCs with projective-wire charge readouts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TDCOSMO - XVII. New time delays in 22 lensed quasars from optical monitoring with the ESO-VST 2.6m and MPG 2.2m telescopes

We present new time delays, the main ingredient of time delay cosmography, for 22 lensed quasars resulting from high-cadence r-band monitoring on the 2.6 m ESO VLT Survey Telescope and Max-Planck-Gesellschaft 2.2 m telescope. Each lensed quasar was typically monitored for one to four seasons, often shared between the two telescopes to mitigate the interruptions forced by the COVID-19 pandemic. The sample of targets consists of 19 quadruply and 3 doubly imaged quasars, which received a total of 1918 hours of on-sky time split into 21 581 wide-field frames, each 320 seconds long. In a given field, the 5-σ depth of the combined exposures typically reaches the 27th magnitude, while that of single visits is 24.5 mag – similar to the expected depth of the upcoming Vera-Rubin LSST. The fluxes of the different lensed images of the targets were reliably de-blended, providing not only light curves with photometric precision down to the photon noise limit, but also high-resolution models of the targets whose features and astrometry were systematically confirmed in Hubble Space Telescope imaging. This was made possible thanks to a new photometric pipeline, lightcurver, and the forward modelling method STARRED. Finally, the time delays between pairs of curves and their uncertainties were estimated, taking into account the degeneracy due to microlensing, and for the first time the full covariance matrices of the delay pairs are provided. Of note, this survey, with 13 square degrees, has applications beyond that of time delays, such as the study of the structure function of the multiple high-redshift quasars present in the footprint at a new high in terms of both depth and frequency. The reduced images will be available through the European Southern Observatory Science Portal.Key words: methods: data analysis / surveys / distance scale

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗