Search NASA⌕ Search

SEARCH · Search NASA

Results for “Balloon Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

The Vega balloons - A tool for studying atmosphere dynamics on Venus

The Vega balloon experiment, designed to measure the dynamics of the Venus atmosphere, comprised the balloons themselves, their gondolas with on-board sensors and radio transmitters, and the radio telescope network on the earth. The structures and the physical parameters of the balloon probe are described, together with the instruments on the gondola, designed for the measurements of the atmospheric pressure, temperature, and vertical wind flows, and illumination, as well as possible flashes of lightning. Consideration is also given to the formatting of the information flow for the individual parameters measured.

Kremnev, R. S.↗

Global budget of stratospheric trace constituents (GLOBUS). MAP/GLOBUS 1983: A review

MAP/GLOBUS 1983 was a project for the study of stratospheric trace gases and dynamics. A respective field campaign was performed in September/October 1983 in Western Europe. A large number of measurements were taken by instruments based on the ground, on airplane, balloons, and satellite. The structure of the campaign is described, and a survey of the results are given.

Offermann, D.↗

A balloon-borne payload for imaging hard X-rays and gamma rays from solar flares

Hard X-rays and gamma rays provide direct evidence of the roles of accelerated particles in solar flares. An approach that employs a spatial Fourier-transform technique for imaging the sources of these emissions is described, and the development of a balloon-borne imaging device based on this instrumental technique is presented. The detectors, together with the imaging optics, are sensitive to hard X-ray and gamma-ray emission in the energy-range from 20 to 700 keV. This payload, scheduled for its first flight in June 1992, will provide 11-arc second angular resolution and millisecond time resolution with a whole-sun field of view. For subsequent flights, the effective detector area can be increased by as much as a factor of four, and imaging optics with angular resolution as fine as 2 arcsec can be added to the existing gondola and metering structures.

Crannell, Carol J.↗

Results of international Dobson spectrophotometer calibrations at Arosa, Switzerland, 1990

An international comparison of Dobson ozone spectrophotometers, organized and partially funded by the World Meteorological Organization (WMO), was held at the Lichtklimatisches Observatorium (LKO) in Arosa, Switzerland, July-August 1990. Countries participating with a total of 18 Dobson instruments were Belgium, Czechoslovakia, Denmark, Germany, Greece, Hungary, Iceland, Norway, Poland, Portugal, Rumania, Spain, Switzerland, the United Kingdom, the United States, and the United Soviet Socialist Republics. The reference standard instrument for the comparison was U.S.A. Secondary Standard Dobson Spectrophotometer 65 maintained by the NOAA Climate and Monitoring and Diagnostics Laboratory, Boulder, Colorado. The mean difference in ozone obtained with the Dobson instruments relative to Dobson instrument 65, calculated from ADDSGQP observations in the air mass range 1.15-3.2, was minus 1.0 plus or minus 1.2 (1 sigma) percent. The WMO Standard Brewer Spectrometer 39 also participated. In the mean, the Brewer instrument measured 0.6 plus or minus 0.2 (1 sigma) percent more ozone than did Dobson instrument 65. Results are presented, also, of ozone vertical profile measurements made with the Dobson instruments, two Brewer spectrometers, a LIDAR, a balloon ozonesonde flown from Hohenpeissenberg, Germany, and balloon ozonesondes flown from Payerne, Switzerland.

Grass, R. D.↗

In situ measurements of nitric oxide, ozone, and aerosols in the Scandinavian Arctic stratosphere in January 1992

During the European Arctic Stratospheric Ozone Experiment (EASOE) the Arctic stratosphere was investigated with a set of instruments flown on a CNES high altitude balloon from ESRANGE, northern Sweden (67 deg 52 minutes N, 21 deg 4 minutes E) on January 22, 1992. The vertical profiles to an altitude of 30 km are presented for ozone, nitric oxide, aerosols, and the temperature. The ozone mixing ratio was less than 0.1 ppmv below 13 km, and increased significantly only above the 18.5 km level. The aerosol concentration profile shows a large peak between 13 km and 21 km, centered at 18.5 km, reaching as high as about 10 particles/cu cm. Above 24 km the aerosols were absent. Below 22 km, the NO mixing ratio was lower than 50 pptv; however it increased rapidly from 23 km with a sharp peak at 27 km. The rapid increase in NO occurs just at the altitude where the aerosol concentration falls below the detection limit: on this day, NO was present only in the absence of aerosols.

Aimedieu, P.↗

Balloon Flight Tests of a Gas-Ionization-Chamber-Based Isotope Spectrometer

High resolution studies of the isotopic composition of heavy elements in the galactic cosmic radiation have been performed using satellites. The performance of the Tracking Heavy Isotope Spectrometer Telescopes for Low Energies (THISTLE) is investigated using data from a balloon flight carried out in 1993. The instrument design is discussed; and data, and additional analysis, is shown.

Spectrometer THISTLE Isotopes Telescope↗

Lavoisier: A Low Altitude Balloon Network for Probing the Deep Atmosphere and Surface of Venus

The in-situ exploration of the low atmosphere and surface of Venus is clearly the next step of Venus exploration. Understanding the geochemistry of the low atmosphere, interacting with rocks, and the way the integrated Venus system evolved, under the combined effects of inner planet cooling and intense atmospheric greenhouse, is a major challenge of modern planetology. Due to the dense atmosphere (95 bars at the surface), balloon platforms offer an interesting means to transport and land in-situ measurement instruments. Due to the large Archimede force, a 2 cubic meter He-pressurized balloon floating at 10 km altitude may carry up to 60 kg of payload. LAVOISIER is a project submitted to ESA in 2000, in the follow up and spirit of the balloon deployed at cloud level by the Russian Vega mission in 1986. It is composed of a descent probe, for detailed noble gas and atmosphere composition analysis, and of a network of 3 balloons for geochemical and geophysical investigations at local, regional and global scales.

Chaasefiere, E.↗

SAGE III/ISS Validation of Ozone and Water Vapor V5.2 Data Using Collocated Balloon-Borne Measurements

The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument installed on the International Space Station (ISS) has completed nearly four years of data collection and production of science data products. The SAGE III/ISS is a solar and lunar occultation instrument that scans the light from the Sun and Moon through the limb of the Earth’s atmosphere to produce vertical profiles of aerosol, ozone, water vapor, and other trace gases. It continues the legacy of previous SAGE instruments dating back to the 1970s to provide data continuity of stratospheric constituents critical for assessing trends in the ozone layer. This presentation shows the validation results of comparing SAGE III/ISS ozone and water vapor vertical profiles from the newly released v5.2 science product with those of balloon launched ozonesonde and frost point hygrometer measurements and satellite data from the Microwave Limb Sounder.

S Kizer↗

THE SuperTIGER Instrument: Measurement of Elemental Abundances of Ultra-Heavy Galactic Cosmic Rays

The SuperTIGER (Super Trans-Iron Galactic Element Recorder) instrument was developed to measure the abundances of galactic cosmic-ray elements from Ne-10 to Zr-40 with individual element resolution and the high statistics needed to test models of cosmic-ray origins. SuperTIGER also makes exploratory measurements of the abundances of elements with 40 < Z < or = 60 and measures the energy spectra of the more abundant elements for Z < or = 30 from about 0.8 to 10 GeV/nucleon. This instrument is an enlarged and higher resolution version of the earlier TIGER instrument. It was designed to provide the largest geometric acceptance possible and to reach as high an altitude as possible, flying on a standard long-duration 1.11 million cu m balloon. SuperTIGER was launched from Williams Field, McMurdo Station, Antarctica, on 2012 December 8, and made about 2.7 revolutions around the South Pole in 55 days of flight, returning data on over 50 x 10(exp 6) cosmic-ray nuclei with Z > or = 10, including approx.1300 with Z > 29 and approx.60 with Z > 49. Here, we describe the instrument, the methods of charge identification employed, the SuperTIGER balloon flight, and the instrument performance.

abundances↗

The Balloon Intercomparison Campaigns - An introduction and overview

The Balloon Intercomparison Campaigns of 1982 and 1983 involved a comparison of measurements by 21 instruments from seven countries, assembled on four gondolas, assigned to collect data on the vertical profiles of HCl, HNO3, NO2, NO, O3, and many other stratospheric constituents. Most of these sensors supplied data on more than two constituents. This paper describes the instruments and the constituents measured by each of the sensor and the parameters of each balloon flight, together with some results.

Watson, R. T.↗

ArcticShark Uncrewed Aerial System

Some studies of atmospheric processes benefit from specialized instrumented observation platforms, including towers, crewed aircraft, tethered balloon systems, and uncrewed aerial systems (UAS). The ArcticShark UAS, managed by the U.S. Department of Energy’s (DOE’s) Atmospheric Radiation Measurement (ARM) User Facility, has emerged as a vital scientific platform, providing comprehensive measurements to expand the horizons of atmospheric research and ARM data. The ArcticShark focuses on small-scale, accurate, and repetitive flight patterns over areas of scientific interest, including ARM’s ground observatories in Alabama and Oklahoma. When used in concert with data from ground-based instruments and other aerial platforms, UAS observations help deliver a complete picture of atmospheric processes, helping scientists evaluate and improve the accuracy of earth system models needed to inform energy infrastructure planning.

47 OTHER INSTRUMENTATION↗

The energy spectrum of cosmic ray electrons between 9 and 300 GeV

The high-energy cosmic-ray electron spectrum between 9 and 300 GeV has been measured using an instrument consisting of a combination of a transition-radiation detector and a shower detector. The instrument has been calibrated at accelerators over the energy range 5-300 GeV and has been exposed in a balloon flight for 9.3 sq m sr hr. The design of the instrument and the data analysis procedures are described. It is found that the electron spectrum is significantly steeper than the proton spectrum. If the spectrum is fitted to a single power law, a spectral index of 3.35 is obtained. This suggests the influence of radiative energy losses on galactic electrons at low energies. The results are interpreted in the context of the homogeneous model for galactic cosmic rays.

Prince, T. A.↗

An Overview of the Meteorological Instrumentation Utilized for the Design and Operations of Space Launch Vehicles

One of the first hurdles a space vehicle must overcome is the ability to successfully traverse Earth’s atmosphere. In order to achieve this goal, there must exist both climatological and real-time atmospheric data from the surface to the Karman line. The Natural Environments Branch at the National Aeronautics and Space Administration’s Marshall Space Flight Center utilizes both traditional and specialized meteorological instrumentation to aide in both the design and operations of launch vehicles. Weather balloons measuring thermodynamic and wind data from 0 - 70 kft are an example of the more traditional instrumentation. While the Tropospheric Doppler Radar Weather Profiler that measures winds from roughly 5 kft – 60 kft every five minutes is an example of a more specialized instrument. Other instruments include: 915 MHz Doppler Radar Wind Profilers, rain gauges, meteorological towers, lightning detection networks, Automated Weather Observing System stations, Mobile Launcher weather stations, and more. This presentation will give a high-level overview of which instruments are utilized, how the data are acquired, and how the data are ultimately used in design and/or operations.

Nathan L. Curtis↗

Vertical Profiles of Cloud Condensation Nuclei, Condensation Nuclei, Optical Aerosol, Aerosol Optical Properties, and Aerosol Volatility Measured from Balloons

Under the support of this grant a balloon-borne gondola containing a variety of aerosol instruments was developed and flown from Laramie, Wyoming, (41 deg N, 105 deg W) and from Lauder, New Zealand (45 deg S, 170 deg E). The gondola includes instruments to measure the concentrations of condensation nuclei (CN), cloud condensation nuclei (CCN), optically detectable aerosol (OA.) (r greater than or equal to 0.15 - 2.0 microns), and optical scattering properties using a nephelometer (lambda = 530 microns). All instruments sampled from a common inlet which was heated to 40 C on ascent and to 160 C on descent. Flights with the CN counter, OA counter, and nephelometer began in July 1994. The CCN counter was added in November 1994, and the engineering problems were solved by June 1995. Since then the flights have included all four instruments, and were completed in January 1998. Altogether there were 20 flights from Laramie, approximately 5 per year, and 2 from Lauder. Of these there were one or more engineering problems on 6 of the flights from Laramie, hence the data are somewhat limited on those 6 flights, while a complete data set was obtained from the other 14 flights. Good CCN data are available from 12 of the Laramie flights. The two flights from Lauder in January 1998 were successful for all measurements. The results from these flights, and the development of the balloon-bome CCN counter have formed the basis for five conference presentations. The heated and unheated CN and OA measurements have been used to estimate the mass fraction of the aerosol volatile, while comparisons of the nephelometer measurements were used to estimate the light scattering, associated with the volatile aerosol. These estimates were calculated for 0.5 km averages of the ascent and descent data between 2.5 km and the tropopause, near 11.5 km.

Deshler, T.↗

Enhancing the ATIC Charge Resolution

The Advanced Thin Ionization Calorimeter (ATIC) experiment measures the energy spectra of elements, from H to Fe, in the energy region from about 100 GeV to tens of TeV. The ATIC instrument was flown twice in long-duration balloon flights around the South Pole; the ATIC-1 test flight during Dec. 2000 - Jan. 2001 and the ATIC-2 science flight during Dec. 2002 - Jan. 2003. Analyses of both datasets have, to date, relied upon the highly segmented Silicon Matrix (SiM) detector to separate the incident cosmic ray from the calorimeter backscatter and to identify the charge. This method has worked well, enabling ATIC to separate protons from helium and to resolve all the major species up through iron. This charge resolution can be significantly improved by restricting the analysis to particle trajectories that pass through two SiM pixels at the cost of using only a fraction of the potential instrument geometry. However, immediately below the SiM is the two layer SI hodoscope (x, y) consisting of Bicron BC-408 plastic scintillator 2 cm wide, 1 cm thick, 88.2 cm long strips viewed by Hamamatsu R5611 photomultiplier tubes on each end of each strip. The primary purpose of the ATIC hodoscopes is to provide a fast trigger, and each hodoscope includes two crossed layers of strips (42 per layer in the case of Sl) providing supplemental particle trajectory information. The hodoscope readout electronics were designed to provide reasonable charge resolution over the dynamic range from protons through iron. This presentation discusses the S 1 hodoscope energy deposit calibrations, examines the charge resolution possible with this detector and investigates combining the S1 and SiM charge measurements to improve the overall ATIC charge resolution while minimizing degradation of the instrument geometry.

Guzik, T. G.↗

The Gamma-Ray Imaging Spectrometer (GRIS): A new balloon-borne experiment for gamma-ray line astronomy

High resolution gamma-ray spectroscopy is a relatively new field that holds great promise for further understanding of high energy astrophysical processes. When the high resolution gamma-ray spectrometer (GRSE) was removed from the GRO payload, a balloon program was initiated to permit continued development and improvement of instrumentation in this field, as well as continued scientific observations. The Gamma-Ray Imaging Spectrometer (GRIS) is one of the experiments selected as part of this program. The instrument contains a number of new and innovative features that are expected to produce a significant improvement in source location accuracy and sensitivity over previous balloon and satellite experiments.

Teegarden, B. J.↗

Cosmic Radiation Dose Measurements from the RaD-X Flight Campaign

The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission obtained measurements for improving the understanding of cosmic radiation transport in the atmosphere and human exposure to this ionizing radiation field in the aircraft environment. The value of dosimetric measurements from the balloon platform is that they can be used to characterize cosmic ray primaries, the ultimate source of aviation radiation exposure. In addition, radiation detectors were flown to assess their potential application to long-term, continuous monitoring of the aircraft radiation environment. The RaD-X balloon was successfully launched from Fort Sumner, New Mexico (34.5 degrees North, 104.2 degrees West) on 25 September 2015. Over 18 hours of flight data were obtained from each of the four different science instruments at altitudes above 20 kilometers. The RaD-X balloon flight was supplemented by contemporaneous aircraft measurements. Flight-averaged dosimetric quantities are reported at seven altitudes to provide benchmark measurements for improving aviation radiation models. The altitude range of the flight data extends from commercial aircraft altitudes to above the Pfotzer maximum where the dosimetric quantities are influenced by cosmic ray primaries. The RaD-X balloon flight observed an absence of the Pfotzer maximum in the measurements of dose equivalent rate.

Mertens, Christopher J.↗