Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bolometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A diffraction-limited far-infrared imager for the KAO

We describe both our current instrument and a follow-on instrument expected to be operational at the start of the next flight year on the KAO. The current instrument uses a 20-channel bolometer array arranged in two columns of 10 detectors each. Broadband observations can be made at the true diffraction limit, lambda/2D, at either 50 or 100 microns during a flight. Our forthcoming system will use two arrays of 3 x 10 detectors to enable simultaneous imaging at both 50 and 100 microns at the KAO diffraction limit for each wavelength. Observing modes and typical sensitivities will be discussed.

Harvey, Paul M.↗

Noise Temperature and IF Bandwidth of a 530 GHz Heterodyne Receiver Employing a Diffusion-Cooled Superconducting Hot-Electron Mixer

We report on the first heterodyne measurements with a diffusion-cooled hot-electron bolometer mixer in the submillimeter wave band, using a waveguide mixer cooled to 2.2 K. The best receiver noise temperature at a local oscillator frequency of 533 GHz and an intermediate frequency of 1.4 GHz was 650 K (double sideband). The 3 dB IF roll-off frequency was around 1.7 to 1.9 GHz, with a weak dependence on the device bias conditions.

Skalare, A.↗

Bolometric detector systems for IR and mm-wave space astronomy

Recent developments in bolometric detector systems for millimeter and submillimeter wave space astronomy are described. Current technologies meet all the requirements for the high frequency instrument onboard the cosmic background radiation anisotropy satellite/satellite for the measurement of background anisotropies (COBRAS/SAMBA) platform. It is considered that the technologies that are currently being developed will significantly reduce the effective time constant and/or the cooling requirements of bolometric detectors. These technologies lend themselves to the fabrication of the large format arrays required for the Far Infrared and Submillimeter Space Telescope (FIRST). The scientific goals and detector requirements of the COBRAS/SAMBA platform that will use infrared bolometers are reviewed and the baseline detector system is described, including the feed optics, the infrared filters, the cold amplifiers and the warm readout electronics.

Church, S. E.↗

The South Pole Imaging Fabry Perot Interferometer (SPIFI)

The design and construction of the South Pole imaging Fabry-Perot interferometer (SPIFI) is reported. The SPIFI is a direct detection imaging spectrometer for use in the far infrared and submillimeter bands accessible to the 1.7 m telescope at the South Pole, and in the submillimeter bands accessible to the 15 m James Clerk Maxwell Telescope (JCMT), HI. It employs a 5 x 5 silicon bolometer array and three cryogenic Fabry Perot interferometers in series in order to achieve velocity resolutions of between 300 km/s and 30 km/s over the entire field of view with a resolution of up to 1 km/s at the center pixel. The scientific justification for the instrument is discussed, considering the spectral lines available to SPIFI. The optical path, the cryogenic Fabry-Perot, the adiabatic demagnetization refrigerator and the detector array are described. The instrument's sensitivity is presented and compared with coherent systems.

Stacey, G. J.↗

Development of a High-Resolution, Single-Photon X-Ray Detector

Research on the development of a low-temperature, magnetic bolometer for x-ray detection is reported. The principal accomplishments during the first phase of this research are as follows. (1) We have constructed SQUID magnetometers and detected both 122 keV and 6 keV x-rays in relatively larger metallic samples with high quantum efficiency. (2) The magnetic properties of a metal sample with localized paramagnetic spins have been measured and found to agree with theoretical expectations. (3) The size of the magnetic response of the sample to x-rays is in agreement with predictions based on the properties of the sample and sensitivity of the magnetometer, supporting the prediction that a resolution of 1 eV at 10 keV should be achievable.

Seidel, George M.↗

Infrared and Reflected Solar Radiation Measurements from the TIROS 2 Meteorological Satellite

TIROS II contains instrumentation for measuring infrared and reflected solar radiation from the earth and its atmosphere. A medium resolution scanning radiometer and a low resolution non-scanning radiometer are employed. The satellite's spin provides the scan line of the medium resolution radiometer which is then advanced by the orbital motion. The spatial resolution is about 40 miles square when the earth directly beneath the satellite is viewed. The five channels employ bolometer detectors and filters to limit the spectral responses to five bands: 6 to 6.5 microns, 8 to 12 microns, 0.2 to 6 microns, 8 to 30 microns, and 0.55 to 0.75 microns. These five bands study, respectively: radiation in the water vapor absorption band; day and nighttime cloud cover; albedo; thermal radiation; and visual maps for comparison with satellite vidicon pictures. The low resolution non-scanning radiometer measures the earth's black-body temperature and albedo. Its field when viewing directly below is a circle of 450 miles diameter, covering part of each frame from the wide-field television camera. This radiometer consists of two thermistors, each in the apex of a reflective cone which provides optical gain. One thermistor is black and responds to both thermal and reflected solar radiation. The second responds to thermal but reflects solar radiation. The design, calibration, performance, and data reduction for both systems are discussed herein.

Bandeen, W. R.↗

A 2 THz Heterodyne Array Receiver for SOFIA

We proposed to perform a comprehensive design study of a 16-element heterodyne array receiver for SOFIA. The array was designed to utilize hot-electron bolometers in an efficient, low-cost waveguide mount to achieve low noise performance between approx. 1500 and 2400 GHz. Due to the prevailing physical conditions in the interstellar medium, this frequency range is one of the richest in the FIR portion of the spectrum. An array designed for this wavelength range will make excellent use of the telescope and the available atmospheric transmission, and will provide a new perspective on stellar, chemical, and galaxy evolution in the present as well as past epochs. A few of the most important molecular and atomic species which the instrument will sample are CII, OI, CO, OH, NII, and CH. The system used the most sensitive detectors available in an efficient optical system. The local oscillator was a compact CO2 pumped far-infrared laser currently under development for SOFIA. The backend spectrometer was an array acousto-optic spectrometer (aAOS). The spectrometer utilizes proven hardware and technologies to provide broadband performance (greater than or equal to 1 GHz per AOS channel) and high spectral resolution (1 MHz) with the maximum sensitivity and minimum complexity and cost. The proposed instrument would be the fastest and most sensitive heterodyne receiver ever to operate in the 1.5 - 2.4 THz band. One of the key technologies developed for the proposed instrument is the laser micromachining of waveguide structures. These structures provide both the optical link between the instrument and the telescope (via an array of efficient feedhorns) and the impedance transformation between the detectors and free space. With the assistance of funds provided from this grant, we were able to fabricate and test the world's first laser micromachined feedhorns. Figure 1 is a photograph of the 2 THz double feedhorn structure designed and constructed under the auspices of this grant. The quality of the waveguide structure is far better than that obtainable using any other fabrication technique. Figure 2 is the beam pattern obtained from it. The beam parameters are an excellent match to what is expected from theory. The success of this experiment demonstrates the viability of using laser micromachined components in the development of high performance, large format array receivers. Figure 3 is an illustration of the focal plane array concept we developed lot- SOFIA base upon this work. Un- fortunately, our instrument proposal was not selected as a first generation SOFIA instrument. However, we have continued our development efforts and will propose to build a 2nd generation instrument based on the same design concepts. Our work under NAG 2-1057 was very rewarding and we appreciate the opportunity provided by NASA to pursue it. The research led directly to publishing 2 papers (listed below) and the award of an NSF grant to our group to construct a laser micromachining system on the University of Arizona campus.

Walker, Christopher K.↗

A 2 THz Heterodyne Array Receiver for SOFIA: Summary of Research

We proposed to perform a comprehensive design study of a 16-element heterodyne array receiver for SOFIA. The array was designed to utilize hot-electron bolometers in an efficient, low-cost waveguide mount to achieve low noise performance between approximately 1500 and 2400 GHz. Due to the prevailing physical conditions in the interstellar medium, this frequency range is one of the richest in the Far-Infra Red (FIR) portion of the spectrum. An array designed for this wavelength range will make excellent use of the telescope and the available atmospheric transmission, and will provide a new perspective on stellar, chemical, and galactic evolution in the present as well as past epochs. A few of the most important molecular and atomic species which the instrument will sample are CII, OI, CO, OH, NII, and CH. The system used the most sensitive detectors available in an efficient optical system. The local oscillator was a compact CO2 pumped far-infrared laser currently under development for SOFIA. The backend spectrometer was an array acousto-optic spectrometer (aAOS). The spectrometer utilizes proven hardware and technologies to provide broadband performance (> 1 GHz per AOS channel) and high spectral resolution (1 MHz) with the maximum sensitivity and minimum complexity and cost. The proposed instrument would be the fastest and most sensitive heterodyne receiver ever to operate in the 1.5 - 2.4 THz band. One of the key technologies developed for the proposed instrument is the laser micromachining of waveguide structures. These structures provide both the optical link between the instrument and the telescope (via an array of efficient feedhorns) and the impedance transformation between the detectors and free space. With the assistance of funds provided from this grant, we were able to fabricate and test the world's first laser micromachined feedhorns. The quality of the waveguide structure is far better than that obtainable using any other fabrication technique. The beam parameters are an excellent match to what is expected from theory. The success of this experiment demonstrates the viability of using laser micromachined components in the development of high performance, large format array receivers. We have continued our development efforts and will propose to build a 2nd generation instrument based on the same design concepts.

Walker, Christopher K.↗

Far-Infrared Heterodyne Spectrometer for SOFIA

This report summarizes work done under NASA Grant NAG2-1062 awarded to the University of Colorado. The project goal was to evaluate the scientific capabilities and technical requirements for a far-infrared heterodyne spectrometer suitable for the SOFIA Airborne Observatory, which is now being developed by NASA under contract to the Universities Space Research Association (USRA). The conclusions detailed below include our specific recommendations for astronomical observations, as well as our intended technical approach for reaching these scientific goals. These conclusions were presented to USRA in the form of a proposal to build this instrument. USRA subsequently awarded the University of Colorado a 3-year grant (USRA 8500-98-010) to develop the proposed Hot-Electron micro-Bolometer (HEB) mixer concept for high frequencies above 3 THz, as well as other semiconductor mixer technologies suitable for high sensitivity receivers in the 2-6 THz frequency band.

Betz, A. L.↗

The Clouds and the Earth's Radiant Energy System (CERES) Sensors and Preflight Calibration Plans

The Clouds and the Earth's Radiant Energy System (CERES) spacecraft sensors are designed to measure broadband earth-reflected solar shortwave (0.3-5 microns) and earth-emitted longwave (5- > 100 microns) radiances at the top of the atmosphere as part of the Mission to Planet Earth program. The scanning thermistor bolometer sensors respond to radiances in the broadband shortwave (0.3-5 microns) and total-wave (0.3- > 100 microns) spectral regions, as well as to radiances in the narrowband water vapor window (8-12 microns) region. 'ne sensors are designed to operate for a minimum of 5 years aboard the NASA Tropical Rainfall Measuring Mission and Earth Observing System AM-1 spacecraft platforms that are scheduled for launches in 1997 and 1998, respectively. The flight sensors and the in-flight calibration systems will be calibrated in a vacuum ground facility using reference radiance sources, tied to the international temperature scale of 1990. The calibrations will be used to derive sensor gains, offsets, spectral responses, and point spread functions within and outside of the field of view. The shortwave, total-wave, and window ground calibration accuracy requirements (1 sigma) are +/-0.8, +/-0.6, and +/-0.3 W /sq m/sr, respectively, while the corresponding measurement precisions are +/-O.5% and +/-1.0% for the broadband longwave and shortwave radiances, respectively. The CERES sensors, in-flight calibration systems, and ground calibration instrumentation are described along with outlines of the preflight and in-flight calibration approaches.

Lee, Robert B., III↗

Fabrication of Pop-up Detector Arrays on Si Wafers

High sensitivity is a basic requirement for a new generation of thermal detectors. To meet the requirement, close-packed, two-dimensional silicon detector arrays have been developed in NASA Goddard Space Flight Center. The goal of the task is to fabricate detector arrays configured with thermal detectors such as infrared bolometers and x-ray calorimeters to use in space fliGht missions. This paper focuses on the fabrication and the mechanical testing of detector arrays in a 0.2 mm pixel size, the smallest pop-up detectors being developed so far. These array structures, nicknamed "PUDS" for "Pop-Up Detectors", are fabricated on I pm thick, single-crystal, silicon membranes. Their designs have been refined so we can utilize the flexibility of thin silicon films by actually folding the silicon membranes to 90 degrees in order to obtain close-packed two-dimensional arrays. The PUD elements consist of a detector platform and two legs for mechanical support while also serving as electrical and thermal paths. Torsion bars and cantilevers connecting the detector platform to the legs provide additional flexures for strain relief. Using micro-electromechanical structure (MEMS) fabrication techniques, including photolithography, anisotropic chemical etching, reactive-ion etching, and laser dicing, we have fabricated PLTD detector arrays of fourteen designs with a variation of four parameters including cantilever length, torsion bar length and width, and leg length. Folding tests were conducted to test mechanical stress distribution for the array structures. We obtained folding yields and selected optimum design parameters to reach minimal stress levels. Computer simulation was also employed to verify mechanical behaviors of PUDs in the folding process. In addition, scanning electron microscopy was utilized to examine the flatness of detectors and the alignment of detector pixels in arrays. The fabrication of thermistors and heaters on the pop-up detectors is under way, preparing us for the next step of the experiment, the thermal test.

Li, Mary J.↗

Swift: A Widefield Imaging Fabry Perot for Sofia

Contract was to pursue feasibility studies of the SOFIA Widefield Imaging Fabry-Perot (SWIFT). SWIFT was proposed as a two color 18 to 40 microns imaging Fabry-Perot that utilized two Rockwell/Boeing 256 x 256 pixel Si:Sb BIBs as detective devices. The colors were to be split between 26 and 30 microns using a MgO dichroic. The resolution achieving devices were to be a pair of cryogenic fully tunable scanning Fabry-Perot interferometers (FPIs), two in each band. For high resolving powers, a third, fixed FPI is inserted into the beam. The FPI mirrors were to be made of free standing metal mesh. We also proposed to look into a long wavelength (40 to 210 microns) band during the feasibility study period. We produced a proposal to USRA, submitted in July 1997 that substantially refined our ideas. We decided the long wavelength science was compelling, so the baseline wavelength coverage for SWIFT was widened to 17 to 205 microns. Under typical operations, we proposed to simultaneously image in two bands: 22 to 38 microns, and 50 to 205 microns. The bands were to be split by a cold CaF2 dichroic. The short wavelength (SW) band was to employ a 256 x 256 pixel Boeing/Rockwell Si:Sb BIB array, and the long wavelength (LW) band was to employ a Goddard 6 x 32 (upgradable to 32 x 32) element array of monolithic silicon "pop-up" bolometers as detective devices. The two color capability doubled the data taking efficiency, and ensured "perfect" registration between the images obtained in each band. For the SW band, the beam was to be fully sampled (0.7" pixels, 1.4 in. beam) at 17 microns, and over sampled at longer wavelengths. Even so, SWIFT has a very large (3 ft x 3 ft) field of view. To match the SW and LW fields of view (initially in one dimension only, but in 2-dimensions with 32 x 32 upgrade), SWIFT was to under sample at 63 microns (5.6 in pixels, 5.2 in beam) resulting in a 0.56 x 3 in (upgrade to 3 in x 3 in) field of view. Each band has both Lo-Res (R triple bond lambda/Delta(lambda) approx. 30 to 200) and Hi-Res (R approx. 1000 up to 10(exp 5)) modes, that can be changed in less than a minute. Spectral resolution is obtained with four identical cryogenic, fully tunable, scanning FPIS, two in each band, plus a set of fixed order FPI that can be rotated into the beam for good spectral purity at the highest resolving powers. SWIFT was proposed to explore three primary topics of scientific interest: 1. Protostars, Young Stellar Objects, and Protoplanetary Disks. 2. The Galactic Center. 3. External Galaxies.

Stacey, Gordon J.↗

A 2 THz Heterodyne Array Receiver for SOFIA

We proposed to perform a comprehensive design study of a 16-element heterodyne array receiver for SOFIA. The array was designed to utilize hot-electron bolometers in an efficient, low-cost waveguide mount to achieve low noise performance between approx. 1500 and 2400 GHz. Due to the prevailing physical conditions in the interstellar medium, this frequency range is one of the richest in the FIR portion of the spectrum. An array designed for this wavelength range will make excellent use of the telescope and the available atmospheric transmission, and will provide a new perspective on stellar, chemical, and galaxy evolution in the present as well as past epochs. A few of the most important molecular and atomic species which the instrument will sample are CII, OI, CO, OH, NII, and CH. The system used the most sensitive detectors available in an efficient optical system. The local oscillator was a compact CO2 pumped far-infrared laser currently under development for SOFIA. The backend spectrometer was an array acousto-optic spectrometer (aAOS). The spectrometer utilizes proven hardware and technologies to provide broadband performance (greater than or equal to 1 GHz per AOS channel) and high spectral resolution (1 MHz) with the maximum sensitivity and minimum complexity and cost. The proposed instrument would be the fastest and most sensitive heterodyne receiver ever to operate in the 1.5 - 2.4 THz band. One of the key technologies developed for the proposed instrument is the laser micromachining of waveguide structures. These structures provide both the optical link between the instrument and the telescope (via an array of efficient feedhorns) and the impedance transformation between the detectors and free space. With the assistance of funds provided from this grant, we were able to fabricate and test the world's first laser micromachined feedhorns. The quality of the waveguide structure is far better than that obtainable using any other fabrication technique. The beam parameters are an excellent match to what is expected from theory. The success of this experiment demonstrates the viability of using laser micromachined components in the development of high performance, large format array receivers. Unfortunately, our instrument proposal was not selected as a first generation SOFIA instrument. However, we have continued our development efforts and will propose to build a 2nd generation instrument based on the same design concepts.

Walker, Christopher K.↗

Far-Infrared Heterodyne Spectrometer for Sofia

The project goal was to evaluate the scientific capabilities and technical requirements for a far-infrared heterodyne spectrometer suitable for the SOFIA Airborne Observatory, which is now being developed by NASA under contract to the Universities Space Research Association (USRA). The conclusions detailed below include our specific recommendations for astronomical observations, as well as our intended technical approach for reaching these scientific goals. These conclusions were presented to USRA in the form of a proposal to build this instrument. USRA subsequently awarded the University of Colorado a 3-year grant to develop the proposed Hot-Electron micro-Bolometer (HEB) mixer concept for high frequencies above 3 THz, as well as other semiconductor mixer technologies suitable for high sensitivity receivers in the 2-6 THz frequency band.

Betz, A. L.↗

Spectroscopic Capabilities and Possibilities of the Far Infrared and Submillimeter Telescope Mission

The Far Infrared and Submillimeter Telescope (FIRST) mission is the fourth European Space Agency corner stone mission. FIRST will be an observatory with a passively cooled (80 Kelvin) 3.5 meter class telescope and three cryogenic instruments covering the 670 to 80 mm spectral region. The mission is slated for a 4.5 year operational lifetime in an L2 orbit. It will share an Arian 5 launch with PLANCK in early 2007. The three payload instruments include the Spectral and Photometric Imaging Receiver (SPIRE), which is a bolometer array with Martin-Puplett FTS for 200-670 microns, the Photoconductor Array Camera and Spectrometer (PACS), which is a photoconductor array with a grating spectrometer for 80-210 microns and the Heterodyne Instrument for FIRST (HIFI), which is a series of seven heterodyne receivers covering 480-1250 GHz and portions of 1410-1910 GHz and 2400-2700 GHz. FIRST will make many detailed spectral surveys of a wide variety of objects previously obscured by the atmosphere and in regions of the spectrum seldom used for astronomical observations, With all of the spectroscopic capability on FIRST a great deal of laboratory spectroscopic support will be needed for accurate interpretation of the spectral data.

Pearson, J. C.↗

Sub-Micron Long HTS Ho Electron Mixers

The hot-electron bolometer mixer made from a high-T, superconductor (HTS) was introduced recently as an alternative to a Schottky mixer at THz frequencies. The performance of the mixer depends on the total thermal conductance for heat removal from the phonon sub-system due to either length-dependent phonon diffusion or phonon escape to the substrate. We have measured both the length and temperature dependencies of the IF bandwidth of the mixers fabricated from 25-35 mn thick YBCO films on MgO and sapphire substrates. The films were grown by a laser deposition technique and electron-beam lithography was used to define bridge lengths down to 50 nm. Mixer measurements were done using signal frequencies in the range of 1-100 GHz. For 50 nm and 400 nm long devices on MgO, the 3-dB bandwidth was about 100 MHz. At temperatures below 60 K, the hot-electron plateau was clearly seen starting around 2-3 GHz. At temperatures above 70 K, the flux-flow effects begin to dominate and the IF bandwidth increases to 1-8 GHz, while the conversion efficiency drops by several dB. This temperature dependence of the IF bandwidth can account for previously reported unexpectedly high bandwidth of HTS mixers.

Harnack, 0.↗

Relationship Between the Clouds and the Earth's Radiant Energy System (CERES) Measurements and Surface Temperatures of Selected Ocean Regions

Clear sky longwave radiances and fluxes are compared with the sea surface temperatures for three oceanic regions: Atlantic, Indian, and Pacific. The Clouds and the Earth's Radiant Energy System (CERES) measurements were obtained by the three thermistor bolometers: total channel which measures the radiation arising from the earth-atmosphere system between 0.3 - greater than 100 micrometers; the window channel which measures the radiation from 8-12 micrometers; and the shortwave channel which measures the reflected energy from 0.3 - less than 5.0 micrometers. These instruments have demonstrated measurement precisions of approximately 0.3% on the International Temperature Scale of 1990 (ITS-90) between ground and on-orbit sensor calibrations. In this work we have used eight months of clear sky earth-nadir-view radiance data starting from January 1998 through August 1998. We have found a very strong correlation of 0.97 between the CERES window channel's weekly averaged unfiltered spectral radiance values at satellite altitude (350 km) and the corresponding weekly averaged sea surface temperature (SST) data covering all the oceanic regions. Such correlation can be used in predicting the sea surface temperatures using the present CERES Terra's window channel radiances at satellite altitude very easily.

Pandey, Dhirendra, K.↗

Development of Low-Noise High Value Chromium Silicide Resistors for Cryogenic Detector Applications

Extremely high sensitivity detectors, such as silicon bolometers are required in many NASA missions for detection of photons from the x-ray to the far infrared regions. Typically, these detectors are cooled to well below the liquid helium (LHe) temperature (4.2 K) to achieve the maximum detection performance. As photoconductors, they are generally operated with a load resistor and a pre-set bias voltage, which is then coupled to the input gate of a source-follower Field Effect Transistor (FET) circuit. It is imperative that the detector system signal to noise performance be limited by the noise of the detector and not by the noise of the external components. The load resistor value is selected to optimize the detector performance. These two criteria tend to be contradictory in that these detectors require load resistors in the hundreds of megaohms, which leads to a higher Johnson noise. Additionally, the physical size of the resistor must be small for device integration as required by such missions as the NASA High Resolution Airborne Wide-Band Camera (HAWC) instrument and the Submillimeter High Angular Resolution Camera (SHARC) for the Caltech Submillimeter Observatory (CSO). We have designed, fabricated and characterized thin film resistors using a CrSi/TiW/Al metal system on optical quality quartz substrates. The resistor values range from 100 megaohms to over 650 megaohms and are Johnson noise limited at LHe temperatures. The resistor film is sputtered with a sheet resistance ranging from 300 ohms to 1600 ohms and the processing sequence developed for these devices allows for chemically fine tuning the sheet resistance in-situ. The wafer fabrication process was of sufficiently high yield (>80%) providing clusters of good resistors for integrated multiple detector channels, a very important feature in the assembly of these two instruments.

Jhabvala, Murzy↗