Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Developing energy flexibility in clusters of buildings: A critical analysis of barriers from planning to operation

This paper examines building energy flexibility at an aggregated level and addresses the main barriers and research gaps for the development of this resource across three design and development phases: market and policy, early planning and design, and operation. We review methodologies and tools and discuss barriers, challenges, and opportunities, incorporating policy, economic, technical, professional, and social perspectives. Although various legal and regulatory frameworks exist to foster the development of energy flexibility for small buildings, financing mechanisms are limited with a significant number of perceived risks undermining private investment. For the early planning and design phase, planners and designers lack appropriate tools and face interoperability challenges, which often results in insufficient consideration of demand response programs. The review of the operational phase highlighted the socio-technical challenges related to both the complexity of deployment and communication, as well as privacy and acceptability issues. Finally, the paper proposes a number of targeted research directions to address challenges and promote greater energy flexibility deployments, including capturing building demand side dynamics, improving baseline estimations and developing seamless connectivity between buildings and districts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Physics-informed machine learning for building performance simulation-A review of a nascent field

Building performance simulation (BPS) is critical for understanding building dynamics and behavior, analyzing the performance of the built environment, optimizing energy efficiency, improving demand flexibility, and enhancing building resilience. However, conducting BPS is not trivial. Traditional BPS relies on accurate building energy models, which are primarily physics-based and heavily dependent on detailed building information, expert knowledge, and case-by-case model calibrations, significantly limiting their scalability. With the development of sensing technology and the increased availability of data, there is growing attention and interest in data-driven BPS. However, purely data-driven models often suffer from limited generalization ability and a lack of physical consistency, resulting in poor performance in real-world applications. To address these limitations, recent studies have begun integrating physics priors into data-driven models, a methodology known as physics-informed machine learning (PIML). PIML is an emerging field where its definitions, methodologies, evaluation criteria, application scenarios, and future directions remain open. To bridge those gaps, this study systematically reviews the state-of-the-art PIML for BPS, offering a comprehensive definition of PIML and comparing it to traditional BPS approaches regarding data requirements, modeling effort, performance, and computational cost. We also summarize the commonly used methodologies, validation approaches, application domains, available data sources, open-source packages, and testbeds. In addition, this study provides a general guideline for selecting appropriate PIML models based on BPS applications. Finally, this study identifies key challenges and outlines future research directions, providing a solid foundation and valuable insights to advance R&D of PIML in BPS.

Jiang, Zixin↗

Model predictive control for demand flexibility: Real-world operation of a commercial building with photovoltaic and battery systems

Hundreds of studies have investigated Model Predictive Control (MPC) for the optimal operation of building energy systems in the past two decades. However, MPC field tests are still uncommon, especially for small- and medium-sized commercial buildings and for buildings integrated with onsite renewables. This paper describes the implementation and the long-term performance evaluation of an MPC controller in a small commercial building equipped with behind-the-meter photovoltaics and electrochemical batteries. MPC controls space conditioning, commercial refrigeration, and the battery system. We tested two types of demand flexibility applications in the field: electricity bill minimization under time-of-use tariffs and responses to grid flexibility events. Results show that the proposed controller achieves 12% of annual electricity cost savings and 34% peak demand reduction against the baseline, while respecting thermal comfort and food safety. The field tests also demonstrate the ability of the MPC controller to provide a multitude of grid services including real-time pricing, demand limiting, load shedding, load shifting, and load tracking, using the same optimization framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated Controls Package for High Performance Interior Retrofit [Slides]

For the last few years, networked lighting control (NLCs) have promised significant energy savings beyond what is achieved through a basic light-emitting diode (LED) lighting retrofit. At the same time, NLCs can substantially increase the cost and complexity of the lighting retrofit. And as lighting system wattage declines because of the increasing efficiency of LEDs, advanced controls have less lighting energy to save and the cost-effectiveness of the NLC investment decreases. But NLCs can be leveraged to achieve significant energy savings and value by enhancing control of other building systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid Service Values of Generic Marginal Building Flexibility in Modeled 2030 U.S. Power Systems

The datasets include the capacity, energy, and ancillary service values of a marginal kilowatt-hour (kWh) of generic, daily, shiftable building flexibility as a presumed market entrant in the 2030 U.S. power systems. The results should be interpreted along with the caveats listed in "Valuation of Building Flexibility: Grid Service Value for Initial Market Entrants in Projected 2030 United States Power Systems", which also documents the methods used for the study. The factors examined in the study include: grid scenario, region, original usage hour in the day (local time), and building flexibility parameters - efficiency, dissipation, and shifting window include max pre-shift and max post-shift. Filenames in the datasets: The filenames contain information on the grid scenario, and the building flexibility efficiency and dissipation. For example: MidCase_2030_efficiency1.25_dissipation0.05_value.csv contains all results under Mid RE 2020, efficiency = 1.25, and dissipation = 0.05. * MidCase = Mid RE Each .csv file contains: region: The location of the building flexibility, aligned with U.S. Energy Information Administration (EIA) National Energy Modeling System (NEMS) Electricity Market Module regions. max_pre_shift: Part of building flexibility shifting window parameter, indicates the max number of hours the building flexibility can shift earlier. max_post_shift: Part of building flexibility shifting window parameter, indicates the max number of hours the building flexibility can shift later. local_datetime: Original datetime of 1kWh of building energy consumption. local_orig_h: Original usage hour (1-24) of building energy consumption, ignores daylight saving. local_shift_to: The datetime to when building energy consumption shifts, if shifting happens. If no shifting occurs, this cell is left blank. energy: Net energy value of energy shifting. capacity: Net capacity value of energy shifting. shifting_value: Net energy plus capacity value of energy shifting. spin: Spin reserve value at the original datetime of consumption. flex: Flexible reserve value at the original datetime of consumption. reg: Regulation reserve value at the original datetime of consumption. total_profit: Assuming the building flexibility is capable of providing energy, capacity, and ancillary services, total profit is the maximum value of energy shifting value, spin reserve value, flexible reserve value, and regulation reserve value - one of the four choices at any given hour - because we do not allow its value to be double-counted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DIVERSE ENERGY STORAGE TECHNOLOGY

Behind the meter electrical energy storage in buildings as a means of peak shaving and time-of-use shifting has been demonstrated to provide utility bill savings in buildings with high electricity demand, while simultaneously relieving strain on the electric grid during peak periods. Batteries have dominated the building energy storage market but are still expensive and have a relatively short lifetime. The Ground Level Integrated Diverse Energy Storage (GLIDES) system is a newly invented electric energy storage technology which can leverage waste heat to improve its round-trip efficiency (RTE) and energy density and lifetime. It has demonstrated an RTE of 51.6% in laboratory testing, and modeled improvements demonstrate the potential for 75% RTE. This paper reports on the development of GLIDES and its potential value in buildings.

Abuheiba, Ahmad↗

Assessment of the Potential to Achieve very Low Energy Use in Public Buildings in China with Advanced Window and Shading Systems

As rapid growth in the construction industry continues to occur in China, the increased demand for a higher standard living is driving significant growth in energy use and demand across the country. Building codes and standards have been implemented to head off this trend, tightening prescriptive requirements for fenestration component measures using methods similar to the U.S. model energy code American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1. The objective of this study is to (a) provide an overview of applicable code requirements and current efforts within China to enable characterization and comparison of window and shading products, and (b) quantify the load reduction and energy savings potential of several key advanced window and shading systems, given the divergent views on how space conditioning requirements will be met in the future. System-level heating and cooling loads and energy use performance were evaluated for a code-compliant large office building using the EnergyPlus building energy simulation program. Commercially-available, highly-insulating, low-emittance windows were found to produce 24%–66% lower perimeter zone HVAC electricity use compared to the mandated energy-efficiency standard in force (GB 50189-2005) in cold climates like Beijing. Low-e windows with operable exterior shading produced up to 30%–80% reductions in perimeter zone HVAC electricity use in Beijing and 18%–38% reductions in Shanghai compared to the standard. The economic context of China is unique since the cost of labor and materials for the building industry is so low. Broad deployment of these commercially available technologies with the proper supporting infrastructure for design, specification, and verification in the field would enable significant reductions in energy use and greenhouse gas emissions in the near term.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MPCPy: An Open-Source Software Platform for Model Predictive Control in Buildings

Within the last decade, needs for building control systems that reduce cost, energy, or peak demand, and that facilitate building-grid integration, district-energy system optimization, and occupant interaction, while maintaining thermal comfort and indoor air quality, have come about. Current PID and schedule-based control systems are not capable of fulfilling these needs, while Model Predictive Control (MPC) could. Despite the critical role MPC-enabled buildings can play in future energy infrastructures, widespread adoption of MPC within the building industry has yet to occur. To address barriers associated with system setup and configuration, this paper introduces an open-source software platform that emphasizes use of self-tuning adaptive models, usability by non-experts of MPC, and a flexible architecture that enables application across projects.

Blum, David↗

MPC solution for optimal load shifting for buildings with ON/OFF staged packaged units: Experimental demonstration, and lessons learned

Small and medium-sized commercial buildings (SMCB) are significant demand response resources, and it is important to develop grid-responsive control algorithms that exploit those resources and create financial benefits for building owners and HVAC service providers. Furthermore, unlike large-sized commercial buildings, there is an opportunity to have universally applicable control solutions for many SMCBs since those buildings have a consistent HVAC system configuration: SMCBs are commonly served by multiple-staged air conditioning units controlled by their own thermostats. Despite the demand response potential and scalability, however, very few control solutions are available for SMCBs. Typical model predictive control (MPC) and heuristic control approaches for cooling load shifting that lower thermostat setpoints before an electric price jump are suitable mainly for large-sized commercial buildings where a continuous capacity modulation is possible, e.g., via dampers in variable air volume terminal units. However, those approaches can cause undesired, high peaks for SMCBs due to the nature of ON/OFF unit staging and narrow thermostat deadbands. This could discourage the use of advanced grid-responsive controls for SMCBs due to the concern of high demand charges, and has to be resolved. This paper presents a MPC solution that overcomes this challenge. It has a hierarchical MPC structure where an upper level MPC is responsible for electrical load shifting in response to an electric price signal while a lower level MPC is responsible for coordinating compressor stages to eliminate unnecessary peaks and follows the setpoints determined by the upper level MPC. In this work, two one-month, comprehensive laboratory tests have been carried out to demonstrate load shifting and cost savings for the algorithm. Interesting trade-offs between energy efficiency and load flexibility were observed and are discussed, and lessons learned for applying MPCs for SMCBs are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Experience with and Potential for Multi-time Scale Grid Transactions from Responsive Commercial Buildings

The need for and concepts behind demand response are evolving. As the electric system changes with more intermittent renewable electric supply systems, there is a need to allow buildings to provide more flexible demand. This paper presents results from field studies and pilots, as well as engineering estimates of the potential capabilities of fast load responsiveness in commercial buildings. We present a sector wide analysis of flexible loads in commercial buildings, which was conducted to improve resource planning and determine which loads to evaluate in future demonstrations. These systems provide important capabilities for future transactional systems. The field analysis is based on results from California, plus projects in the northwest and east coast. End-uses considered include heating, ventilation, air conditioning and lighting. The timescales of control include day-ahead, as well as day-of, 10-minute ahead and even faster response. This technology can provide DR signals on different times scales to interact with responsive building loads. We describe the latency of the control systems in the building and the round trip communications with the wholesale grid operators.

Piette, Mary Ann↗

Field Experience with and Potential for Multi-time Scale Grid Transactions from Responsive Commercial Buildings

The need for and concepts behind demand response are evolving. As the electric system changes with more intermittent renewable electric supply systems, there is a need to allow buildings to provide more flexible demand. This paper presents results from field studies and pilots, as well as engineering estimates of the potential capabilities of fast load responsiveness in commercial buildings. We present a sector wide analysis of flexible loads in commercial buildings, which was conducted to improve resource planning and determine which loads to evaluate in future demonstrations. These systems provide important capabilities for future transactional systems. The field analysis is based on results from California, plus projects in the northwest and east coast. End-uses considered include heating, ventilation, air conditioning and lighting. The timescales of control include day-ahead, as well as day-of, 10-minute ahead and even faster response. This technology can provide DR signals on different times scales to interact with responsive building loads. We describe the latency of the control systems in the building and the round trip communications with the wholesale grid operators.

Piette, Mary Ann↗

Study on Auto-DR and Pre-Cooling of Commercial Buildings with Thermal Mass in California

This paper discusses how to optimize pre-cooling strategies for buildings in a hot California climate zone with the Demand Response Quick Assessment Tool (DRQAT), a building energy simulation tool. This paper outlines the procedure used to develop and calibrate DRQAT simulation models, and applies this procedure to eleven field test buildings. The results of a comparison between the measured demand savings during the peak period and the savings predicted by the simulation model indicate that the predicted demand shed match well with measured data for the corresponding auto-demand response (Auto-DR) days. The study shows that the accuracy of the simulation models is greatly improved after calibrating the initial models with measured data. These improved models can be used to predict load reductions for automated demand response events. The simulation results were compared with field test data to confirm the actual effect of demand response strategies. Results indicate that the optimal demand response strategies worked well for most of the buildings tested in this hot climate zone.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar + Storage Synergies for Managing Commercial-Customer Demand Charges

Demand charges, which are based on a customer’s maximum demand in kilowatts (kW), are a common element of electricity rate structures for commercial customers. Customer-sited solar photovoltaic (PV) systems can potentially reduce demand charges, but the level of savings is difficult to predict, given variations in demand charge designs, customer loads, and PV generation profiles. Lawrence Berkeley National Laboratory (Berkeley Lab) and the National Renewable Energy Laboratory (NREL) are collaborating on a series of studies to understand how solar PV can impact demand charges. Prior studies in the series examined demand charge reductions from solar on a stand-alone basis for residential and commercial customers. Those earlier analyses found that solar, alone, has limited ability to reduce demand charges depending on the specific design of the demand charge and on the shape of the customer’s load profile. This latest analysis estimates demand charge savings from solar in commercial buildings when co-deployed with behind-the-meter storage, highlighting the complementary roles of the two technologies. The analysis is based on simulated loads, solar generation, and storage dispatch across a wide variety of building types, locations, system configurations, and demand charge designs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stochastic scheduling for commercial building cooling systems: considering uncertainty in zone temperature prediction

Here, this paper presents the first attempt to address the uncertainty in zone temperature prediction with stochastic optimization. The uncertain zone temperature is a process uncertainty and has not been considered in the existing stochastic optimization for building control. To fill this gap, we proposed a novel formulation of stochastic optimization to handle process uncertainty in building control. Specifically, we first examined the accuracy of a typical linear model for predicting zone temperature. We then formulated the scheduling of the building cooling system as a stochastic optimization problem over a 24-hour look-ahead period to minimize the electricity cost of the studied building cooling system. After that, we applied the proposed stochastic load scheduling (SLS) to a direct expansion (DX) cooling system that serves a medium office building. Through simulation with a detailed building energy simulation software, EnergyPlus, we evaluated the operational cost and the thermal comfort compared with a deterministic load scheduling. The operation cost of scheduling was found to vary with the level of zone temperature prediction uncertainty. The proposed SLS can mitigate the impacts of uncertain zone temperature predictions on both operational cost and thermal comfort. The evaluation results indicate that the proposed SLS works better when the uncertainty level is more significant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Modeling of Standard Commercial Building Re-tuning Measures: Large Office Buildings

Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BAS's capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This report investigates the energy savings potential of several common HVAC system retuning measures on a typical large office building prototype model, using the Department of Energy's building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy as an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated - each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All of these measures and combinations were simulated in 16 cities representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC energy savings for most cities for all measures). Combining many of the retuning measures revealed deep savings potential. Some of the more aggressive combinations revealed 35-75% reductions in annual HVAC energy consumption, depending on climate and building vintage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy savings modelling of re-tuning energy conservation measures in large office buildings

Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BAS’s capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This paper investigates the energy savings potential of several common HVAC system re-tuning measures on a typical large office building, using the Department of Energy’s building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy as an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply-air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated – each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All the individual measures and combinations were simulated in 16 climate locations representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual total HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC energy savings for most cities for all measures). Combining many of the re-tuning measures revealed deep savings potential. Some of the more aggressive combinations revealed 35-75% reductions in annual HVAC energy consumption, depending on climate and building vintage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hardware-in-the-loop Laboratory Performance Verification of Flexible Building Equipment in a Typical Commercial Building

This project aims to develop high-resolution equipment performance and occupant data that quantifies demand flexibility in typical commercial buildings. The dataset documented in this report includes comprehensive time-series measurements from hardware-in-the-loop (HIL) experiments conducted across multiple testbeds designed to simulate realistic operational environments for HVAC systems. Specifically, it captures minute-by-minute high-resolution data on the performance of various typical HVAC systems, including a variable-air-volume (VAV) air handling unit (AHU) system with chillers and an ice tank in the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), a two-stage air-source heat pump (ASHP) at the NIST, and a water-source heat pump (WSHP) at Texas A&M University (TAMU). The data were generated under a range of controlled conditions reflecting different grid scenarios and climatic influences, as well as various control strategies, building types, occupancy patterns, and occupant behaviors. This dataset provides DE-EE0009153 Final Report 5 detailed insights into the demand flexibility of these systems, including their response to grid signals, occupant behaviors, energy consumption patterns, and operational efficiency under different conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗